Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Fukushima Daiichi—A Case Study for BWR Instrumentation and Control Systems Performance During a Severe Accident, Rev 1

This report provides an assessment of the performance of various instrumentation and control (I&C) and monitoring systems, with a focus on the first few days of the Fukushima Daiichi accident starting on March 11, 2011. Similar to what occurred at the Three Mile Island Unit 2 (TMI-2) accident in 1979, operator responses were challenged when information on key parameters was lost, erroneous, or misleading. While numerous improvements in instrumentation capabilities have been made since the TMI-2 event, the accident at Fukushima Daiichi suggests the potential for further improvement. The objective of this research is to review the performance of the Fukushima Daiichi Units 1–3 instrumentation systems that could have helped ensure that plant operators and emergency responders had relevant, accurate, and timely knowledge of plant conditions as they managed the accident response. As was the case with TMI-2, forensic analyses of plant instrumentation failures will be a long-term effort. As an introduction to this long-term research, this report focuses on the information available in the control room during the accident and illustrates the challenges to operators in their understanding of plant conditions during the progression of the accident. I&C systems monitor the success or failure of achievement of light water reactor safety principles in which the protection of the reactor fuel, reactor coolant system, and reactor containment is accomplished. This report (1) provides an overview of the safety principles; (2) notes parameters associated with the boiling water reactor (BWR)/3 and BWR/4 protection, actuation, and monitoring systems as they relate to the achievement of these principles; (3) presents data from past research on predicted instrumentation performance during severe accidents, and (4) assesses performance of the key I&C and monitoring systems associated with BWR/3 and BWR/4 reactors like those at Fukushima Daiichi. Lessons learned or potential improvements associated with the performance of these systems in the context of severe accidents are delineated. As background information, an overview of key BWR/3- and BWR/4-Mark I reactor designs (BWR/3 and BWR/4 with a Mark I containment) reactor protection, engineered safety features actuation, and accident monitoring systems is provided. A brief description of plant safety systems used to prevent or mitigate reactor accidents is also provided. This background information provides context for the brief discussion of previous research that has been conducted on BWR severe accidents and for the discussion of the accident sequences, which led to core damage at Fukushima Daiichi Units 1–3. The progression of the accident sequences at Fukushima Daiichi Units 1–3 occurred very much as predicted in prior severe accident research conducted in the United States and internationally, given the complete station blackout that occurred when the tsunami generated by one of the most powerful earthquakes ever recorded rolled onshore.

Accident Tolerant Equipment↗

Spill-to-spill and daily proton energy consistency with a new accelerator control system

The Loma Linda University proton accelerator has had several upgrades installed including synchrotron dipole power supplies and a system for monitoring the beam energy. The consistency of the energy from spill-to-spill has been tested by measuring the depth ionization at the distal edge as a function of time. These measurements were made with a minimally equipped beamline to reduce interference from confounding factors. The consistency of the energy over several months was measured in a treatment room beamline using an ionization chamber based daily quality assurance device. The results showed that the energy of protons delivered from the accelerator (in terms of water equivalent range) was consistent from spill-to-spill to better than {+-}0.03 mm at 70, 155, and 250 MeV and that the energy check performed each day in the treatment room over a several month period was within {+-}0.11 mm ({+-}0.06 MeV) at 149 MeV. These results are within the tolerances required for the energy stacking technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Advanced Instrumentation, Information, and Control System Technologies: Nondestructive Examination Technologies - FY11 Report

Licensees of commercial nuclear power plants in the US are expected to submit license renewal applications for the period of operation of 60 to 80 years which has also been referred to as long term operation (LTO). The greatest challenges to LTO are associated with degradation of passive components as active components are routinely maintained and repaired or placed through maintenance programs. Some passive component degradation concerns include stress corrosion cracking (SCC) of metal components, radiation induced embrittlement of the reactor pressure vessel (RPV), degradation of buried piping, degradation of concrete containment structures, and degradation of cables. Proactive management of passive component aging employs three important elements including online monitoring of degradation, early detection of degradation at precursor stages, and application of prognostics for the prediction of remaining useful life (RUL). This document assesses several nondestructive examination (NDE) measurement technologies for integration into proactive aging management programs. The assessment is performed by discussing the three elements of proactive aging management identified above, considering the current state of the industry with respect to adopting these key elements, and analyzing measurement technologies for monitoring large cracks in metal components, monitoring early degradation at precursor stages, monitoring the degradation of concrete containment structures, and monitoring the degradation of cables. Specific and general needs have been identified through this assessment. General needs identified include the need for environmentally rugged sensors are needed that can operate reliably in an operating reactor environment, the need to identify parameters from precursor monitoring technologies that are unambiguously correlated with the level of pre-macro defect damage, and a methodology for identifying regions where precursor damage is most likely to initiate.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Achieving Verifiable and High Integrity Instrumentation and Control Systems through Complexity Awareness and Constrained Design. Final Report

While most process control industries have been able to embrace digital Instrumentation and Control (I&C) technology to improve performance, reliability, maintainability, and efficiency of production, the nuclear industry has been relatively slow to adopt digital I&C for safety critical plant functions. There are a variety of reasons for this, but in general the nuclear industry takes a conservative stance that new technologies must mature before adoption. A deeper underlying reason for not fully realizing digital I&C and automation in nuclear power is associated with the complexity that can manifest in software-based systems that is different in nature from the complexity of their analog predecessors. Accordingly, this research pursued the development of innovative architectures and methods to “constrain complexity” to enhance verifiability of digital I&C devices. These constraints can positively impact the reduction of Software Common Cause Failures (SCCF) and other systematic errors. The architectural concept developed in this research effort is called SymPLe. SymPLe is specifically aimed at safety critical functions within Nuclear Power Plants and other critical infrastructure where constraining device complexity to support verifiability and safety case arguments is important. The SymPLe architecture is designed to promote “accessible verification” between OEM/utility engineers and the regulatory agencies who review and license nuclear power plant I&C systems. The major contributions of this work to the nuclear industry are: Demonstration of SymPLe as a viable approach to “complexity aware” I&C systems and Embedded Digital Devices.Comprehensive use of model-based design and engineering to produce verifiable I&C systems for the nuclear industry with clear findings on the usability of model-based engineering. Employ comprehensive use of model-based engineering, testing, and verification in an IEC 61508 workflow in support of design assurance. Gathered evidence of “difficult to find” design flaws found using model-based design and testing methods. Detailed the nature of these SCCFs including where they were introduced, the triggers, and how they were found. Gathered evidence on the synergistic use of practical formal methods and testing and how these methods can be used to significantly increase assurance of reduction and avoidance of design flaws.

Testing↗

Assessing the Control Systems Capacity for Demand Response in California Industries

California's electricity markets are moving toward dynamic pricing models, such as real-time pricing, within the next few years, which could have a significant impact on an industrial facility's cost of energy use during the times of peak use. Adequate controls and automated systems that provide industrial facility managers real-time energy use and cost information are necessary for successful implementation of a comprehensive electricity strategy; however, little is known about the current control capacity of California industries. To address this gap, Lawrence Berkeley National Laboratory, in close collaboration with California industrial trade associations, conducted a survey to determine the current state of controls technologies in California industries. This study identifies sectors that have the technical capability to implement Demand Response (DR) and Automated Demand Response (Auto-DR). In an effort to assist policy makers and industry in meeting the challenges of real-time pricing, facility operational and organizational factors were taken into consideration to generate recommendations on which sectors Demand Response efforts should be focused.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The P0 feedback control system blurs the line between IOC and FPGA.

The P0 Feedback system is a new design at the Advanced Photon Source (APS) primarily intended to stabilize a single bunch in order to operate at a higher accumulated charge. The algorithm for this project required a high-speed DSP solution for a single channel that would make adjustments on a turn-by-turn basis. A field programmable gate array (FPGA) solution was selected that not only met the requirements of the project but far exceeded them. By using a single FPGA, we were able to adjust up to 324 bunches on two separate channels with a total computational time of {approx} 6 x 10{sup 9} multiply- accumulate operations per second. The IOC is a Coldfire CPU tightly coupled to the FPGA, providing dedicated control and monitoring of the system through EPICS [1] process variables. One of the benefits of this configuration is having a four-channel scope in the FPGA that can be monitored on a continuous basis.

43 PARTICLE ACCELERATORS↗

Hardware-in-the-Loop Co-Simulation Based Validation of Power System Control Applications

Renewables are key enablers for the realization of a sustainable energy supply but grid operators and energy utilities have to mange their intermittent behavior and limited storage capabilities by ensuring the security of supply and power quality. Advanced control approaches, automation concepts, and communication technologies have the potential to address these challenges by providing new intelligent solutions and products. However, the validation of certain aspects of such smart grid systems, especially advanced control and automation concepts is still a challenge. The main aim of this work therefore is to introduce a hardware-in-the-loop co-simulation-based validation framework which allows the simulation of large-scale power networks and control solutions together with real-world components. The application of this concept to a selected voltage control example shows its applicability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Microreactor Automated Control System Test Bed Digital Architecture for Real-Time, Hardware-in-the-Loop Simulation

This work describes progress made towards the development of a real-time hardware-in-the-loop (HIL) test bed for non-nuclear testing of microreactor control schemes and failure modes. Non-nuclear testing is a crucial step in developing robust control algorithms for managing microreactor dynamics. The creation of an HIL simulation harnesses the realistic dynamics of physical analogue systems while additionally considering the challenges of variable communication delay. This collaborative effort between Oak Ridge National Laboratory and Idaho National Laboratory has resulted in a LabVIEW-based gRPC communication protocol which couples a TRANSFORM Modelica simulation of nuclear components to the ViBRANT physical hardware for realistic feedback and visual representation of control action in real time. A modular python client structure is developed to manage FMU-based Modelica simulation and real-time gRPC communication. HIL testing suggests that the modeled reactor with natural convection molten salt loop coolant configuration responds well to PID control of drum positioning for modulation of reactor core power, however, future efforts will be made to explore the added thermal inertial delay of system level control and downstream demand changes. Development of this platform with a generalized methodology provides a foundation for exploring a variety of reactor configurations and failure modes in rapid order to provide insight into the most effective avenues of study for further research and development.

McConnell, Jono [ORNL] (ORCID:0000000238984741)↗

Upgrade of the gas flow control system of the resistive current leads of the LHC inner triplet magnets: Simulation and experimental validation

The 600 A and 120 A circuits of the inner triplet magnets of the Large Hadron Collider are powered by resistive gas cooled current leads. The current solution for controlling the gas flow of these leads has shown severe operability limitations. In order to allow a more precise and more reliable control of the cooling gas flow, new flowmeters will be installed during the first long shutdown of the LHC. Because of the high level of radiation in the area next to the current leads, the flowmeters will be installed in shielded areas located up to 50 m away from the current leads. The control valves being located next to the current leads, this configuration leads to long piping between the valves and the flowmeters. In order to determine its dynamic behaviour, the proposed system was simulated with a numerical model and validated with experimental measurements performed on a dedicated test bench.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Business Case Analysis for Digital Safety-Related Instrumentation & Control System Modernizations

The commercial nuclear sector faces unprecedented financial challenges driven by low natural gas prices and subsidized renewables in a marketplace that does not reward carbon-free baseload capacity. These circumstances, along with increasingly antiquated labor-centric operating models and analog technology, have forced the premature closure of multiple nuclear facilities and placed a much larger population of nuclear power stations at risk. Nuclear plant economic survival in current and forecasted market conditions requires an efficient and technology-centric operating model that harvests the native efficiencies of advanced technology. This is analogous to transformations in nearly every other industry. In light of previous industry experience in modernizing safety Instrumentation and Controls (I&C) systems, nuclear utilities are reluctant to pursue these upgrades due to uncertainty in licensing and cost.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

RF Matching Feedback Control Systems on the JET ITER-Like Antenna

Ion Cyclotron Resonance Frequency (ICRF) antennas achieve maximum power transfer from RF generator to plasma load by establishing an impedance match. The JET ITER-Like Antenna (ILA) consists of 4 mutually coupled resonators that need to be matched simultaneously and whose resonant states need to be accurately controlled by several available actuators to couple maximum power and to achieve optimal ELM resilience. The operation of the matching system is described. Experimental operation revealed some phenomena and sensitivities that did not surface from simulation alone and that should be taken into account for the design of future ICRF antennae systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Application of LES-CFD for predicting pulverized-coal working conditions after installation of NOx control system

The upcoming environmental requirements outlined at the 2017 European Commission Integrated Pollution Prevention and Control (IPPC) are becoming more and more strict in comparison to the existing standards – IED 2010/75/EU. Questions arise about changes in boiler operating conditions after the adoption of the regulations to fulfill specified emission limits. Of initial concern is the question of which technology to pursue in order to reach the specified level of NOx emissions at 150 mg/Nm 3 @6%O 2 . By introducing an air staging technique the NOx limit can be partially achieved; however these changes affect the boiler operation in a detrimental way. In order to investigate impact of de-NOx installation on the temperature and heat flux distribution, numerical techniques can be used. In order to determine the impact of the changes in the boiler operation, here this paper presents the application of an advanced, multiphase open-source code Arches, developed at the University of Utah for modeling pulverized-coal combustion using Large-Eddy Simulation (LES). Numerical simulations showed the effect on the boiler's working parameters e.g., heat-transfer rate, temperature distribution, species concentration, and NOx emission before and after proposed modifications.

54 ENVIRONMENTAL SCIENCES↗

Web Based Beamline Control System (Bluesky Web) v0.1.0

Bluesky Web is a web based interface that provides beam line controls to the end user. It allows users to issue commands to various physical devices at a beam line end station like motors and cameras. It utilizes an open source Python library (Bluesky) as the controller. It uses Bluesky to also allow for running "plans" or a sequence of device operations that can be used when running an experiment. This program is different from other controls technologies because it is intended to be open source and can be accessed from a web browser, as opposed to other paid software that is run as a stand-alone application on a computer.

De Leon, Seij↗

Control System for RF OPM

SAND2025-01910O This software built in LabVIEW FPGA provides experimental control of the RF OPM prototype via a reconfigurable NI I/O card. It samples the analog input, processes it on the FPGA in real time, and generates control and feedback outputs to control and optimize the operation of the device. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Bainbridge, Jonathan↗

Packetized energy management control systems and methods of using the same

Aspects of the present disclosure include anonymous, asynchronous, and randomized control schemes for distributed energy resources (DERs). Such control schemes may include packetized energy management (PEM) control schemes for managing DERs that may provide near-optimal tracking performance under imperfect information and consumer quality of service (QoS) constraints.

Frolik, Jeffrey↗

Experimental Studies for CPF and SCR Model, Control System, and OBD Development for Engines Using Diesel and Biodiesel Fuels

The research carried out on this project developed experimentally validated Diesel Oxidation Catalyst (DOC), Diesel Particulate Filter (DPF), and Selective Catalytic Reduction (SCR) high-fidelity models that served as the basis for the reduced order models used for internal state estimation. The high-fidelity and reduced order/estimator codes were evaluated by the industrial partners with feedback to MTU that improved the codes. Ammonia, particulate matter (PM) mass retained, PM concentration, and NOX sensors were evaluated and used in conjunction with the estimator codes. The data collected from PM experiments were used to develop the PM kinetics using the high-fidelity DPF code for both NO2 assisted oxidation and thermal oxidation for Ultra Low Sulfur Fuel (ULSF), and B10 and B20 biodiesel fuels. Nine SAE papers were presented and this technology transfer process should provide the basis for industry to improve the OBD and control of urea injection and fuel injection for active regeneration of the PM in the DPF using the computational techniques developed. This knowledge will provide industry the ability to reduce the emissions and fuel consumption from vehicles in the field. Four MS and three PhD Mechanical Engineering students were supported on this project and their thesis research provided them with expertise in experimental, modeling, and controls in aftertreatment systems.

33 ADVANCED PROPULSION SYSTEMS↗

Advanced Thermo-Adsorptive Battery: Advanced Thermo-Adsorptive Battery Climate Control System

HEATS Project: MIT is developing a low-cost, compact, high-capacity, advanced thermoadsorptive battery (ATB) for effective climate control of EVs. The ATB provides both heating and cooling by taking advantage of the materials’ ability to adsorb a significant amount of water. This efficient battery system design could offer up as much as a 30% increase in driving range compared to current EV climate control technology. The ATB provides high-capacity thermal storage with little-to-no electrical power consumption. The ATB is also looking to explore the possibility of shifting peak electricity loads for cooling and heating in a variety of other applications, including commercial and residential buildings, data centers, and telecom facilities.

ARPA-E↗

Developing a Hybrid Electric Vehicle Eco-Cooperative Adaptive Cruise Control System at Signalized Intersections.

This study develops an eco-driving strategy for hybrid electric vehicles (HEVs) in the vicinity of signalized intersections, entitled HEV Eco-Cooperative Adaptive Cruise Control at Intersections (Eco-CACC-I). The proposed system computes real-time, energy-optimized vehicle trajectories using HEV vehicle dynamics and energy consumption models. In the proposed system, a simple HEV energy model is used to compute the instantaneous fuel consumption. This HEV energy model is selected since it is general, transferable, and can be easily used to compute instantaneous energy consumption levels for HEVs without the additional input of vehicle engine data or complicated power control strategies. In addition, a vehicle dynamics model is used to capture the relationship between speed, acceleration level, and tractive/resistance forces on vehicles. The energy-optimum problem is formulated as an optimization problem with constraints, which is solved using a moving-horizon dynamic programming approach. The proposed HEV Eco-CACC-I system was tested to evaluate its performance for various speed limits, roadway grades, and signal timings. Lastly, the proposed HEV controller was implemented in a microscopic traffic simulation software to test its network-wide performance. The test results from an arterial corridor with three signalized intersections demonstrate that the proposed system can effectively reduce stop-and-go traffic in the vicinity of signalized intersections producing savings of 7.4% in energy consumption, 5.8% in traffic delay and 23% vehicle stops, respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗