Search NASA⌕ Search

SEARCH · Search NASA

Results for “Counting statistics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Complementary Probes of Dark Energy using Galaxy Clusters

Here, we have built a framework to constrain Dark Energy (DE) using the spatial distributions, number counts, and escape velocities of galaxy clusters in the context of next generation spectroscopic surveys. In the ΛCDM paradigm, galaxy clusters trace the expansion of the Universe in three different ways. (1.) Spatial distribution:The baryon acoustic oscillations (BAO) formed during recombination are imprinted into the spatial distribution of clusters. The locations of the BAO are standard-rulers which map the length-scale of the sound horizon. Statistical measures like the two-point correlation function and the power spectrum can be used to trace the scale of the BAO and thus the expansion history of the Universe.(2.) Number counts: Galaxy clusters are identified as peaks above a threshold in the underlying matter density field. Galaxies attract onto these peaks over time until gravity loses the battle against the accelerating expansion of space. The number and mass of galaxy clusters over time is sensitive to the strength of the DE and the amount of matter in the Universe.(3.) Escape velocity:The radius-velocity phase-space of galaxies within clusters has a sharp edge which traces the escape velocity of galaxies. This escape velocity is a combination of the local Newtonian gravitational potential and the acceleration of the expansion of the Universe. Weak lensing mass profiles of clusters can be used to predict the escape velocity profile from just the gravitational Newtonian component. In an expanding or contracting Universe, the observed phase-space escape velocity surface would be modified from this prediction.We built the large-scale structure covariances from mock catalogs which we can now use in the likelihood analyses to constrain Dark Energy models. We have developed the analytical framework to conduct the joint likelihood analysis of the bias function and the abundance function in order to constrain DE through their redshift evolution.We have investigated a new Dark Energy test that uses the weak lensing prediction of the grav-itational potential compared to the observed escape velocity profile from galaxy clusters. We have made predictions on the improvement in the Dark Energy figure-of-merit from this new test. We have also investigated the predicted enhancements of the cluster escape velocity profiles from modifi-cations to gravity. This effort can help rule out model classes of modified gravity as alternatives to Dark Energy.

79 ASTRONOMY AND ASTROPHYSICS↗

Investigating Student Understanding for a Statistical Analysis of Two Thermally Interacting Solids

As part of an ongoing research and curriculum development project for upper-division courses in thermal physics, we have developed a sequence of tutorials in which students apply statistical methods to examine the behavior of two interacting Einstein solids. In the sequence, students begin with simple results from probability and develop a means for counting the states in a single Einstein solid. The students then consider the thermal interaction of two solids, and observe that the classical equilibrium state corresponds to the most probable distribution of energy between the two solids. As part of the development of the tutorial sequence, we have developed several assessment questions to probe student understanding of various aspects of this system. In this paper, we describe the strengths and weaknesses of student reasoning, both qualitative and quantitative, to assess the readiness of students for one tutorial in the sequence.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Performance of a GM tube based environmental dose rate monitor operating in the Time-To-Count mode

The events at the Fukushima Daiichi power plant in the aftermath of a natural disaster underline the importance of a large array of networked environmental monitors to cover areas around nuclear power plants. These monitors should meet a few basic criteria: have a uniform response over a wide range of gamma energies, have a uniform response over a wide range of incident angles, and have a large dynamic range. Many of these criteria are met if the probe is qualified to the international standard IEC 60532 (Radiation protection instrumentation - Installed dose rate meters, warning assemblies and monitors - X and gamma radiation of energy between 50 keV and 7 MeV), which specifically deals with energy response, angle of incidence, dynamic range, response time, and a number of environmental characteristics. EcoGamma is a dual GM tube environmental gamma radiation monitor designed specifically to meet the requirements of IEC 60532 and operate in the most extreme conditions. EcoGamma utilizes two energy compensated GM tubes operating with a Time-To-Count (TTC) collection algorithm. The TTC algorithm extends the lifetime and range of a GM tube significantly and allows the dual GM tube probe to achieve linearity over approximately 10 decades of gamma dose rate (from the Sv/hr range to 100 Sv/hr). In the TTC mode of operation, the GM tube is not maintained in a biased condition continuously. This is different from a traditional counting system where the GM tube is held at a constant bias continuously and the total number of strikes that the tube registers are counted. The traditional approach allows for good sensitivity, but does not lend itself to a long lifetime of the tube and is susceptible to linearity issues at high count rates. TTC on the other hand only biases the tube for short periods of time and in effect measures the time between events, which is statistically representative of the total strike rate. Since the tube is not continually biased, the life of the tube is extended and the linearity is greatly improved. Testing has been performed at Pacific Northwest National Laboratory (PNNL) in the USA and confirms compliance to IEC 60532 as well as linearity (± 10%) up to 100 Sv/hr. Furthermore, a network of EcoGamma probes may be linked through available supervisory software to provide a dose rate map of an area. This allows for real time monitoring of dose rates from one (or multiple) remote locations. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Discovery of Activities via Statistical Clustering of Fixation Patterns

Human behavior often consists of a series of distinct activities, each characterized by a unique pattern of interaction with the visual environment. This is true even in a restricted domain, such as a pilot flying an airplane; in this case, activities with distinct visual signatures might be things like communicating, navigating, monitoring, etc. We propose a novel analysis method for gaze-tracking data, to perform blind discovery of these hypothetical activities. We compare, not individual fixations, but groups of fixations aggregated over a fixed time interval (Tau). We assume that the environment has been divided into a finite set of discrete areas-of-interest (AOIs). For a given time interval, we compute the proportion of time spent fixating each AOI, resulting in an N-dimensional vector, where N is the number of AOIs. These proportions can be converted to integer counts by multiplying by Tau divided by the average fixation duration, a parameter that we fix at 283 milliseconds. We compare different intervals by computing the chi-squared statistic. The p-value associated with the statistic is the likelihood of observing the data under the hypothesis that the data in the two intervals were generated by a single process with a single set of probabilities governing the fixation of each AOI. We cluster the intervals, first by merging adjacent intervals that are sufficiently similar, optionally shifting the boundary between non-merged intervals to maximize the difference. Then we compare and cluster non-adjacent intervals. The method is evaluated using synthetic data generated by a hand-crafted set of activities. While the method generally finds more activities than put into the simulation, we have obtained agreement as high as 80 percent between the inferred activity labels and ground truth.

Eye Movements↗

Measurement of neutron and gamma-ray noise in large subcritical condition for criticality safety - 14485

Various experimental methods have been proposed for subcriticality measurement and neutron noise analysis method is one of important experimental techniques for this purpose. The variance to mean value method, called Feynman-alpha method, is one of well-known noise analysis methods. In this method, variation of neutron count rate distribution from the Poisson distribution caused by fission chain reactions, which is called Y-value, is measured, however, it is difficult to measure the Y-value in large subcritical state such as nuclear fuel facility, because number of emitted neutrons by fission chain reaction is small, which causes large statistical error. We developed new experimental technique based on Feynman-alpha method combined with pulsed neutron source, called Delayed Neutron Noise Analysis (DNNA) method, to monitor the change of subcriticality. In this new method, neutron and gamma-ray counts measured only appeared in the delayed neutron region after injection of pulsed neutron are analyzed, and the prompt neutron region is completely ignored. The advantage of DNNA compared with conventional method is that spatial dependency of detector positions on measured results can be greatly decreased, which result in increase of accuracy of measured subcriticality. The validity of the DNNA method was experimentally investigated in the Kyoto University Critical Assembly (KUCA) at Kyoto University Research Reactor Institute. In the experiments, pulsed neutrons by D-T reactions are injected into the core and we used {sup 3}He detectors to measure neutron noise signals and BGO scintillation detectors to measure gamma-ray noise signals, and all data in the delayed neutron region were analyzed based on Feynman-alpha method. From the experimental results, it was found that the Y-values are clearly larger than zero in the case of existence of fuel assemblies and this method can be applied to detection of hidden special nuclear materials for example in a cargo container. (authors)

42 ENGINEERING↗

CLASH: A census of magnified star-forming galaxies at z ∼ 6-8

We utilize 16 band Hubble Space Telescope (HST) observations of 18 lensing clusters obtained as part of the Cluster Lensing And Supernova survey with Hubble (CLASH) Multi-Cycle Treasury program to search for z ∼ 6-8 galaxies. We report the discovery of 204, 45, and 13 Lyman-break galaxy candidates at z ∼ 6, z ∼ 7, and z ∼ 8, respectively, identified from purely photometric redshift selections. This large sample, representing nearly an order of magnitude increase in the number of magnified star-forming galaxies at z ∼ 6-8 presented to date, is unique in that we have observations in four WFC3/UVIS UV, seven ACS/WFC optical, and all five WFC3/IR broadband filters, which enable very accurate photometric redshift selections. We construct detailed lensing models for 17 of the 18 clusters to estimate object magnifications and to identify two new multiply lensed z ≳ 6 candidates. The median magnifications over the 17 clusters are 4, 4, and 5 for the z ∼ 6, z ∼ 7, and z ∼ 8 samples, respectively, over an average area of 4.5 arcmin{sup 2} per cluster. We compare our observed number counts with expectations based on convolving 'blank' field UV luminosity functions through our cluster lens models and find rough agreement down to ∼27 mag, where we begin to suffer significant incompleteness. In all three redshift bins, we find a higher number density at brighter observed magnitudes than the field predictions, empirically demonstrating for the first time the enhanced efficiency of lensing clusters over field surveys. Our number counts also are in general agreement with the lensed expectations from the cluster models, especially at z ∼ 6, where we have the best statistics.

79 ASTRONOMY AND ASTROPHYSICS↗

The X-Ray Variable Sky

A novel approach to search for rapid time variability of every source, whether persistent or transient, within the entire ROSAT detector field has been developed. Semi-automated software statistically tests the photon arrival time event list for source variability and reports significant (greater than 5 sigma) variable enhancement in the photon count rate on time scales ranging from 5-500 seconds. The computational algorithms have been thoroughly tested, and are able to discriminate between false detections induced by instrumental effects, and real X-ray variable sources (XRVs); when carefully scrutinized by the PI. The analysis has proven to be successful, with both periodic and transient XRVs having been found. Some of these are entirely new discoveries, while others have been detected in previous X-ray missions, yet their nature remained elusive since source identification and analysis had yet to be performed. On average, one new (unidentified) XRV is found per ROSAT PSPC field analyzed. In some cases the XRVs show only a transient signature (a burst type event) with no persistent X-ray or other known (optical) counterpart. The ambitious goal of this project was to process as much of the ROSAT PSPC archive data as feasibly possible to discover XRVs and analyze this data.

Stringfellow, Guy↗

Metrological characterization of X-ray diffraction methods at different acquisition geometries for determination of crystallite size in nano-scale materials

Crystallite size values were determined by X-ray diffraction methods for 183 powder samples. The tested size range was from a few to about several hundred nanometers. Crystallite size was calculated with direct use of the Scherrer equation, the Williamson–Hall method and the Rietveld procedure via the application of a series of commercial and free software. The results were statistically treated to estimate the significance of the difference in size resulting from these methods. We also estimated effect of acquisition conditions (Bragg–Brentano, parallel-beam geometry, step size, counting time) and data processing on the calculated crystallite size values. On the basis of the obtained results it is possible to conclude that direct use of the Scherrer equation, Williamson–Hall method and the Rietveld refinement employed by a series of software (EVA, PCW and TOPAS respectively) yield very close results for crystallite sizes less than 60 nm for parallel beam geometry and less than 100 nm for Bragg–Brentano geometry. However, we found that despite the fact that the differences between the crystallite sizes, which were calculated by various methods, are small by absolute values, they are statistically significant in some cases. The values of crystallite size determined from XRD were compared with those obtained by imaging in a transmission (TEM) and scanning electron microscopes (SEM). It was found that there was a good correlation in size only for crystallites smaller than 50 – 60 nm. Highlights: • The crystallite sizes for 183 nanopowders were calculated using different XRD methods • Obtained results were subject to statistical treatment • Results obtained with Bragg-Brentano and parallel beam geometries were compared • Influence of conditions of XRD pattern acquisition on results was estimated • Calculated by XRD crystallite sizes were compared with same obtained by TEM and SEM.

36 MATERIALS SCIENCE↗

Discovery of Activities via Statistical Clustering of Fixation Patterns

Human behavior often consists of a series of distinct activities, each characterized by a unique signature of visual behavior. This is true even in a restricted domain, such as piloting an aircraft, where patterns of visual signatures might represent activities like communicating, navigating, and monitoring. We propose a novel analysis method for gaze-tracking data, to perform blind discovery of these activities based on their behavioral signatures. The method is in some respects similar to recurrence analysis, but here we compare not individual fixations, but groups of fixations aggregated over a fixed time interval. The duration of this interval is a parameter that we will refer to as τ. We assume that the environment has been divided into a set of N different areas-of-interest (AOIs). For a given interval of time of duration τ, we compute the proportion of time spent fixating each AOI, resulting in an N-dimensional vector. These proportions can be converted to counts by multiplying by τ divided by the average fixation duration (another parameter that we fix at 280 milliseconds). We compare different intervals by computing the chi-square statistic. The p-value associated with the statistic is the likelihood of observing the data under the hypothesis that the data in the two intervals were generated by a single process with a single set of probabilities governing the fixation of each AOI. We have investigated the method using a set of 10 synthetic "activities," that sample 4 AOIs. Four of these activities visit 3 of the 4 AOIs, with equal probability; as there are four different ways to leave-one- out, there are four such activities. Similarly, there are six different activities that leave-two-out. Sequences of simulated behavior were generated by running each activity for 40 seconds, in sequence, for a total of 6.7 minutes. The figure to the right shows the matrix of chi-square statistics, using a value of 2.8 seconds for τ, corresponding to 10 fixations. Low values (dark) indicate poor evidence for activity differences, while high values (bright) indicate strong evidence. The dark squares along the main diagonal each correspond to the forty second intervals in which the activity was held constant; the 4x4 block at the lower left corresponds to the four leave-one-out activities, while the 6x6 block in the upper right corresponds to the leave-two-out activities. (The anti-diagonal pattern of white squares indicates those activity pairs that share no AOIs.) The chi-square values can be binarized by choosing a particular significance level; we are interested in grouping bins that represent the same activity, effectively accepting the null hypothesis. Therefore, we may adopt a relatively lax criterion; for example, choosing a p-value of 0.2 means that two behaviors that have only a 1-in-5 chance of being produced by a single activity might nevertheless be clustered together. We have explored several methods to perform clustering on the data and solving for the activity probabilities. Greedy methods begin by selecting the time bin that is similar to the most (or least) other bins, and then forming a cluster from it and all other non-discriminable bins. These methods show mediocre performance, as they do not take into account temporal contiguity. Preliminary results indicate that methods that "grow" clusters in time from seed points perform better.

activity analysis↗

Discovery of Activities via Statistical Clustering of Fixation Patterns

Human behavior often consists of a series of distinct activities, each characterized by a unique pattern of interaction with the visual environment. This is true even in a restricted domain, such as a piloting an aircraft, where activities with distinct visual signatures might be things like communicating, navigating, and monitoring. We propose a novel analysis method for gaze-tracking data, to perform blind discovery of these hypothetical activities. The method is in some respects similar to recurrence analysis, but here we compare not individual fixations, but groups of fixations aggregated over a fixed time interval. The duration of this interval is a parameter that we will refer to as delta. We assume that the environment has been divided into a set of N different areas-of-interest (AOIs). For a given interval of time of duration delta, we compute the proportion of time spent fixating each AOI, resulting in an N-dimensional vector. These proportions can be converted to integer counts by multiplying by delta divided by the average fixation duration (another parameter that we fix at 280 milliseconds). We compare different intervals by computing the chi-square statistic. The p-value associated with the statistic is the likelihood of observing the data under the hypothesis that the data in the two intervals were generated by a single process with a single set of probabilities governing the fixation of each AOI. The method has been applied to approximately 100 hours of eye movement data collected from pilots in a high-fidelity B747 flight simulator, and the results have been compared to synthetic data in which the each activity is represented as first-order Markov process with random probabilities assigned to the AOIs. Randomly-generated synthetic activities can require thousands of fixations to be discriminated with statistical significance, while the human data can be clustered using averaging windows of some 10's of seconds, suggesting that the actual activities are much more narrowly focused than random Markov models.

activity analysis↗

Detection of Spatiotemporal Prescription Opioid Hot Spots With Network Scan Statistics: Multistate Analysis

Background: Overuse and misuse of prescription opioids have become significant public health burdens in the United States. About 11.5 million people are estimated to have misused prescription opioids for nonmedical purposes in 2016. This has led to a significant number of drug overdose deaths in the United States. Previous studies have examined spatiotemporal clusters of opioid misuse, but they have been restricted to circular shaped regions. Objective: The goal of this study was to identify spatiotemporal hot spots of opioid users and opioid prescription claims using Medicare data. Methods: We examined spatiotemporal clusters with significantly higher number of beneficiaries and rate of prescriptions for opioids using Medicare payment data from the Centers for Medicare & Medicaid Services. We used network scan statistics to detect significant clusters with arbitrary shapes, the Kulldorff scan statistic to examine the significant clusters for each year (2013, 2014, and 2015) and an expectation-based version to examine the significant clusters relative to past years. Regression analysis was used to characterize the demographics of the counties that are a part of any significant cluster, and data mining techniques were used to discover the specialties of the anomalous providers. Results: We examined anomalous spatial clusters with respect to opioid prescription claims and beneficiary counts and found some common patterns across states: the counties in the most anomalous clusters were fairly stable in 2014 and 2015, but they have shrunk from 2013. In Virginia, a higher percentage of African Americans in a county lower the odds of the county being anomalous in terms of opioid beneficiary counts to about 0.96 in 2015. For opioid prescription claim counts, the odds were 0.92. This pattern was consistent across the 3 states and across the 3 years. A higher number of people in the county with access to Medicaid increased the odds of the county being in the anomalous cluster to 1.16 in both types of counts in Virginia. A higher number of people with access to direct purchase of insurance plans decreased the odds of a county being in an anomalous cluster to 0.85. The expectation-based scan statistic, which captures change over time, revealed different clusters than the Kulldorff statistic. Providers with an unusually high number of opioid beneficiaries and opioid claims include specialties such as physician’s assistant, nurse practitioner, and family practice. Conclusions: Our analysis of the Medicare claims data provides characteristics of the counties and provider specialties that have higher odds of being anomalous. The empirical analysis identifies highly refined spatial hot spots that are likely to encounter prescription opioid misuse and overdose. The methodology is generic and can be applied to monitor providers and their prescription behaviors in regions that are at a high risk of abuse.

60 APPLIED LIFE SCIENCES↗

Support of selected X-ray studies to be performed using data from the Uhuru (SAS-A) satellite

A new measurement of the diffuse X-ray emission sets more stringent upper limits on the fluctuations of the background and on the number counts of X-ray sources with absolute value of b 20 deg than previous measurements. A random sample of background data from the Uhuru satellite gives a relative fluctuation in excess of statistics of 2.0% between 2.4 and 6.9 keV. The hypothesis that the relative fluctuation exceeds 2.9% can be rejected at the 90% confidence level. No discernable energy dependence is evident in the fluctuations in the pulse height data, when separated into three energy channels of nearly equal width from 1.8 to 10.0 keV. The probability distribution of fluctuations was convolved with the photon noise and cosmic ray background deviation (obtained from the earth-viewing data) to yield the differential source count distribution for high latitude sources. Results imply that a maximum of 160 sources could be between 1.7 and 5.1 x 10 to the -11 power ergs/sq cm/sec (1-3 Uhuru counts).

Garmire, G. P.↗

Latent class analysis to model multiple chemical exposures among children

Highlights: • Latent class analysis identified subgroups of children with unique chemical exposure profiles. • Three subgroups were identified. • One subgroup comprised children with high multiple co-exposures. • Latent classes were sometimes associated with lymphocyte and neutrophil counts. Children are exposed to multiple potentially harmful chemicals simultaneously. Efforts to understand the patterns and consequences of these exposures have been hampered by statistical limitations in estimations of higher order interactions.

54 ENVIRONMENTAL SCIENCES↗

Impact of phenolic substrate and growth temperature on the arthrobacter chlorophenolicus proteome

We compared the Arthrobacter chlorophenolicus proteome during growth on 4-chlorophenol, 4-nitrophenol or phenol at 5 C and 28 C; both for the wild type and a mutant strain with mass spectrometry based proteomics. A label free workflow employing spectral counting identified 3749 proteins across all growth conditions, representing over 70% of the predicted genome and 739 of these proteins form the core proteome. Statistically significant differences were found in the proteomes of cells grown under different conditions including differentiation of hundreds of unknown proteins. The 4-chlorophenol-degradation pathway was confirmed, but not that for phenol.

54 ENVIRONMENTAL SCIENCES↗

Removal of radon progeny from delicate surfaces

210 Po α-decay-driven neutron background is a concern for many rare event search experiments. It is a difficult to control background because its radiogenic component depends on the air exposure history of parts. In this study, we demonstrate that about half of the radon progeny 210 Po can be removed from copper and silicon surfaces relatively easily by wiping a copper sample with acetone-wetted tissue and a silicon detector with acetone soaked cotton balls. For a copper sample, we demonstrate that long-lived 210 Pb is removed with similar effectiveness. For copper, allocated the longest counting time, additional wiping was found to be largely ineffective. For silicon, the removal effectiveness has large uncertainties. Additional cleaning showed a small but statistically significant effect. Here, capitalizing on this trivial cleaning step will allow experiments to relax their requirements on the allowable air exposure time during construction, leading to cost and time savings.

Radioactivity↗

False Indications of Dose-Response Nonlinearity in Large Epidemiologic Cancer Radiation Cohort Studies; A Simulation Exercise

This study explores the likely prevalence of false indications of dose-response nonlinearity in large epidemiologic cancer radiation cohort studies (A-bomb survivors, INWORKS, Techa River). Reasons: Increasing numbers of tests of nonlinearity are being made in studies. Hypothesized nonlinear dose-response models have been justified to policy makers by analyses that rely in part on isolated findings that could be statistical fluctuations. After removing dose nonlinearity (linearization) by adjusting person-years of observation at each dose category, indications of nonlinearity, necessarily false, were counted in 5,000 randomized replications of six datasets. The average frequency of any false positive for five indicators of nonlinearity tested against a linear null was roughly 25% in Monte Carlo simulations per study, consistent with binomial calculations, increasing to ~50% within 6 studies assessed. Comparable frequencies were found using Akaike's information criterion (AIC) for model selection or multi-model averaging. False above-zero threshold doses were found more than 50% of the time, averaging to 0.05 Gy, consistent with findings in the 6 studies. Such bias, uncorrected, could distort meta-analyses of multiple studies, because meta-analyses can incorporate high P value findings. AIC-based correction for the extra threshold parameter lowered these false occurrences to 8 to 19%. Given the simulation rates, the possibility of false positives might be noted when isolated findings of nonlinearity are discussed in a regulatory context. When reporting a threshold dose with a P value > 0.05, it would be informative to note the expected high false prevalence rate due to bias.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Unsteady Pressure-Sensitive-Paint Shot Noise Reduction

In the study of unsteady Pressure-Sensitive Paint (uPSP) image data sets, pixel intensity values collected by Phantom cameras from multiple perspectives are used to calculate the surface pressure of an experimental model. This paper focuses on mitigation of shot noise which is introduced into the image data set by the cameras. Shot noise impacts the quality of data collected, increasing the system error in its pressure value calculations. This paper characterises statistical methods to reduce shot noise within experimental data by taking an average or weighted average across an area of pixels of their respective counts. Each combined-pixel has a higher total effective intensity value and therefore exhibits reduced noise throughout its time history. This is demonstrated by calculating the standard deviations of the combined pixel values through time, which decrease as the combined pixel area increases. Finally, these methods are compared across experimental wind tunnel conditions to examine their effectiveness at different Mach numbers. Ultimately, the results are used to recommend a blur filter type and size which will be applied to the raw image data prior to processing, as well as a minimum camera resolution for future experiments. Downstream of the filter application, the software to convert the 2D image data sets into surface pressure readings on a 3D grid use a ratio of decimation that assigns multiple pixels to each 3D grid node. This decimation ratio will also be aligned with the size of the blur filter, resulting in a more manageable data set size and compromised spatial resolution. Combined with the effect of the blur filter, the resulting pixel intensity readings will exhibit significantly reduced shot noise, reducing the magnitude of uncertainty and error in the final calculated pressure. For future tests, the camera spatial resolution must be sufficient to capture small flow and model features even after the recommended blur filter is applied. The image data set is taken from a uPSP experiment of the Space Launch System Block 1 cargo vehicle model in September 2019.

Lucy Tang↗

Unsteady Pressure-Sensitive Paint (UPSP) Shot Noise Reduction

In the study of unsteady Pressure-Sensitive Paint (uPSP) image data sets, pixel intensity values collected by Phantom cameras from multiple perspectives are used to calculate the surface pressure of an experimental model. This paper focuses on mitigation of shot noise which is introduced into the image data set by the cameras. Shot noise impacts the quality of data collected, increasing the system error in its pressure value calculations. This paper characterises statistical methods to reduce shot noise within experimental data by taking an average or weighted average across an area of pixels of their respective counts. Each combined-pixel has a higher total effective intensity value and therefore exhibits reduced noise throughout its time history. This is demonstrated by calculating the standard deviations of the combined pixel values through time, which decrease as the combined pixel area increases. Finally, these methods are compared across experimental wind tunnel conditions to examine their effectiveness at different Mach numbers. Ultimately, the results are used to recommend a blur filter type and size which will be applied to the raw image data prior to processing, as well as a minimum camera resolution for future experiments. Downstream of the filter application, the software to convert the 2D image data sets into surface pressure readings on a 3D grid use a ratio of decimation that assigns multiple pixels to each 3D grid node. This decimation ratio will also be aligned with the size of the blur filter, resulting in a more manageable data set size and compromised spatial resolution. Combined with the effect of the blur filter, the resulting pixel intensity readings will exhibit significantly reduced shot noise, reducing the magnitude of uncertainty and error in the final calculated pressure. For future tests, the camera spatial resolution must be sufficient to capture small flow and model features even after the recommended blur filter is applied. The image data set is taken from a uPSP experiment of the Space Launch System Block 1 cargo vehicle model in September 2019.

Lucy Tang↗