Search NASA⌕ Search

SEARCH · Search NASA

Results for “Data Distribution Service”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Profitability, Scalability and Optimized Siting for Waste-to-Energy Supply Chains: A Case Study on Hydrothermal Liquefaction

Waste-to-Energy (WtE) conversion technologies have the potential to simultaneously reduce waste volumes, treatment-related emissions, and carbon intensity while producing valuable energy services. However, questions remain regarding under which conditions emerging WtE technologies are feasible to deploy. In this project, we develop an optimized siting method for WtE technologies to assess cost-effective WtE processor locations, throughput scales, and profitability. We apply the model using Hydrothermal Liquefaction (HTL) as an example WtE technology. We develop calibrated capital and operating expense cost curves based on literature data to study the techno-economic characteristics of WtE supply chains. Prior to solving the siting optimization, we analyze the model parameters to describe organic waste management system behavior under four different HTL deployment configurations: Co-Processing, where HTL plants send biocrude to existing conventional refineries via assumed pipelines; Co-Location, where biorefineries are co-located with HTL plants; and two alternative Standalone Biorefining cases, where distributed HTL plants transport biocrude intermediate via either assumed pipelines or trucking to centralized biorefineries. We also define and apply several feedstock gate fee calculations, representing different revenue distribution options, to investigate how bioproduct value could impact WtE supply chain economics in terms of waste producer and processor profit or cost reduction.

09 BIOMASS FUELS↗

Controlling distributed energy resources via deep reinforcement learning for load flexibility and energy efficiency

Behind-the-meter distributed energy resources (DERs), including building solar photovoltaic (PV) technology and electric battery storage, are increasingly being considered as solutions to support carbon reduction goals and increase grid reliability and resiliency. However, dynamic control of these resources in concert with traditional building loads, to effect efficiency and demand flexibility, is not yet commonplace in commercial control products. Traditional rule-based control algorithms do not offer integrated closed-loop control to optimize across systems, and most often, PV and battery systems are operated for energy arbitrage and demand charge management, and not for the provision of grid services. More advanced control approaches, such as MPC control have not been widely adopted in industry because they require significant expertise to develop and deploy. Recent advances in deep reinforcement learning (DRL) offer a promising option to optimize the operation of DER systems and building loads with reduced setup effort. However, there are limited studies that evaluate the efficacy of these methods to control multiple building subsystems simultaneously. Additionally, most of the research has been conducted in simulated environments as opposed to real buildings. This paper proposes a DRL approach that uses a deep deterministic policy gradient algorithm for integrated control of HVAC and electric battery storage systems in the presence of on-site PV generation. The DRL algorithm, trained on synthetic data, was deployed in a physical test building and evaluated against a baseline that uses the current best-in-class rule-based control strategies. Performance in delivering energy efficiency, load shift, and load shed was tested using price-based signals. The results showed that the DRL-based controller can produce cost savings of up to 39.6% as compared to the baseline controller, while maintaining similar thermal comfort in the building. The project team has also integrated the simulation components developed during this work as an OpenAIGym environment and made it publicly available so that prospective DRL researchers can leverage this environment to evaluate alternate DRL algorithms.

24 POWER TRANSMISSION AND DISTRIBUTION↗

EAGLE-I County Customer Dataset Fall 2025

This dataset provides a combination of modeled and collected county-level electric customer counts derived from 2023 EIA-861 utility customer data, 2021 HIFLD electric retail service territory boundaries, 2021 LandScan population estimates, and 2025 EAGLE-I customer outages. The dataset details county FIPS code, number of customers, and customer type (modeled, collected, mixed). Outage data in included for all 50 U.S. states, Puerto Rico, and the District of Columbia (excluding other U.S. territories).

24 POWER TRANSMISSION AND DISTRIBUTION↗

NARUC grid data sharing playbook

In 2022, the National Association of Regulatory Utility Commissioners (NARUC) launched an initiative to support its members in addressing issues related to grid data sharing. The Grid Data Sharing Collaborative was funded by the DOE’s Office of Electricity and Office of Cybersecurity, Energy Security, and Emergency Response (CESER). NARUC invited programmatic, policy, technical, and cybersecurity subject matter experts from public utility commissions, utilities, non-governmental organizations, energy service companies, and DOE to join the two-year Grid Data Sharing Collaborative to help develop a flexible framework for states to use as a starting point when navigating complex decision-making inherent in grid data sharing. The framework took shape through a series of intensive workshops during which Collaborative participants explored illustrative use cases to identify data needs, articulate the benefits and risks of sharing such data, and assess the trade-offs. Along the way, participants offered suggestions for how the framework could be used in practice. The purpose of this playbook is to describe the elements of the Grid Data Sharing Framework and to begin supporting its implementation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design and Performance of Solar Decathlon 2011 High-Penetration Microgrid: Preprint

The U.S. Department of Energy Solar Decathlon challenges collegiate teams to design, build, and operate solar-powered houses that are cost-effective, energy-efficient, and attractive. The Solar Decathlon 2011 was held in Washington, D.C., from September 23 to October 2, 2011 . A high-penetration microgrid was designed, installed, and operated for the Solar Decathlon 2011 to grid-connect 19 highlyenergy-efficient, solar-powered competition houses to a single utility connection point. The capacity penetration of this microgrid (defined as maximum PV generation divided by maximum system load over a two-week period) was 74% based on 1-minute averaged data. Temporary, ground-laid conductors and electrical distribution equipment were installed to grid-connect the Solar Decathlon village,which included the houses as well as other electrical loads used by the event organizers. While 16 of the houses were connected to the 60 Hz microgrid, three houses from Belgium, China, and New Zealand were supplied with 50 Hz power. The design of the microgrid, including the connection of the houses powered by 50 Hz and a standby diesel generator, is discussed in this paper. In addition to theutility-supplied net energy meters at each house, a microgrid monitoring system was installed to measure and record energy consumption and PV energy production at 1-second intervals at each house. Bidirectional electronic voltage regulators were installed for groups of competition houses, which held the service voltage at each house to acceptable levels. The design and successful performance ofthis high-penetration microgrid is presented from the house, microgrid operator, and utility perspectives.

14 SOLAR ENERGY↗

State Spotlight on Resilience: The Michigan Public Service Commission and Data Informed Accountability

Resilience activities are an emerging area within regulatory utility policy. As resilience frameworks develop, many Public Utility Commissions (PUCs) are looking to initiate resilience activities and have identified enhancing grid reliability as a practical starting point. Reliability describes the grid’s ability to deliver electricity steadily and without interruptions under normal or “blue sky” conditions. Reliability is measured using industry standard metrics such as outage frequency (SAIFI) and outage duration (SAIDI). Resilience is broader, reflecting the grid’s ability to both withstand and recover from disruptions, particularly those caused by extreme events such as severe storms. A reliable grid minimizes routine disruptions; a resilient grid ensures the system can recover quickly when disruptions occur, preventing them from escalating into widespread or prolonged crises.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Preparing Los Alamos National Laboratory's Waste Management Program for the Future - 12175

The waste management program at Los Alamos National Laboratory (LANL) is undergoing significant transition to establish a lean highly functioning waste management program that will succeed the large environmental cleanup waste management program. In the coming years, the environmental cleanup activities will be mostly completed and the effort will change to long-term stewardship. What will remain in waste management is a smaller program focused on direct off-site shipping to cost-effectively enable the enduring mission of the laboratory in support of the national nuclear weapons program and fundamental science and research. It is essential that LANL implement a highly functioning efficient waste management program in support of the core missions of the national weapons program and fundamental science and research - and LANL is well on the way to that goal. As LANL continues the transition process, the following concepts have been validated: - Business drivers including the loss of onsite disposal access and completion of major environmental cleanup activities will drive large changes in waste management strategies and program. - A well conceived organizational structure; formal management systems; a customer service attitude; and enthusiastic managers are core to a successful waste management program. - During times of organizational transition, a project management approach to managing change in a complex work place with numerous complex deliverables is successful strategy. - Early and effective engagement with waste generators, especially Project Managers, is critical to successful waste planning. - A well-trained flexible waste management work force is vital. Training plans should include continuous training as a strategy. - A shared fate approach to managing institutional waste decisions, such as the LANL Waste Management Recharge Board is effective. - An efficient WM program benefits greatly from modern technology and innovation in managing waste data and reports. - Use of six-sigma tools can help improve the quality and efficiency of waste management processes. - A fair, easy to understand, transparent, and well-overseen process for distributing the cost of waste disposal and waste program oversight is essential. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An Edge-Cloud Integrated Solution for Buildings Demand Response Using Reinforcement Learning

Buildings, as major energy consumers, can provide great untapped demand response (DR) resources for grid services. However, their participation remains low in real-life. One major impediment for popularizing DR in buildings is the lack of cost-effective automation systems that can be widely adopted. Existing optimization-based smart building control algorithms suffer from high costs on both building-specific modeling and on-demand computing resources. To tackle these issues, this paper proposes a cost-effective edge-cloud integrated solution using reinforcement learning (RL). Beside RL’s ability to solve sequential optimal decision-making problems, its adaptability to easy-to-obtain building models and the off-line learning feature are likely to reduce the controller’s implementation cost. Using a surrogate building model learned automatically from building operation data, an RL agent learns an optimal control policy on cloud infrastructure, and the policy is then distributed to edge devices for execution. Simulation results demonstrate the control efficacy and the learning efficiency in buildings of different sizes. A preliminary cost analysis on a 4-zone commercial building shows the annual cost for optimal policy training is only 2.25% of the DR incentive received. Results of this study show a possible approach with higher return on investment for buildings to participate in DR programs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Resilience Analysis of DC Microgrids under Denial of Service Threats

This paper develops a resilience analysis framework to study the fault ride-through capability of direct current (DC) microgrids in unknown denial of service (DoS) cyber incidents. DoS can be a frequent threat to DC microgrids with advanced controllers that hinge on active information exchanges: it can paralyze data communications and cause control ineptness or even system instability. Furthermore, we show that temporal DoS incidents render the DC microgrid cyber-physical topology and parameters time-varying and cause them to jump between faulty conditions. As existing DC microgrid stability analysis results are primarily developed from time-invariant systems, they might not be valid for the DoS interrupted systems. In this paper, we seek to study whether a DC microgrid is resilient against time-varying unknown DoS incidents. The problem is formulated as a stability analysis problem for a system with randomly switching dynamics. Scalable conditions are developed to provide provable resilience guarantees. In addition, we exploit the special structure of the conditions to yield quantified resilience measure by convex optimization techniques. As a result, the measure can be used for the evaluation of the resilience of different DC microgrid design against DoS incidents. We demonstrate the effectiveness of the proposed work using simulation case studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Population Aging and Heat Exposure in the 21st Century: Which U.S. Regions Are at Greatest Risk and Why?

Abstract Background and Objectives The co-occurring trends of population aging and climate change mean that rising numbers of U.S. older adults are at risk of intensifying heat exposure. We estimate county-level variations in older populations’ heat exposure in the early (1995–2014) and mid (2050) 21st century. We identify the extent to which rising exposures are attributable to climate change versus population aging. Research Design and Methods We estimate older adults’ heat exposure in 3,109 counties in the 48 contiguous U.S. states. Analyses use NASA NEX Global Daily Downscaled Product (NEX-GDDP-CMIP6) climate data and county-level projections for the size and distribution of the U.S. age 69+ population. Results Population aging and rising temperatures are documented throughout the United States, with particular “hotspots” in the Deep South, Florida, and parts of the rural Midwest. Increases in heat exposure by 2050 will be especially steep in historically colder regions with large older populations in New England, the upper Midwest, and rural Mountain regions. Rising temperatures are driving exposure in historically colder regions, whereas population aging is driving exposure in historically warm southern regions. Discussion and Implications Interventions to address the impacts of temperature extremes on older adult well-being should consider the geographic distribution and drivers of this exposure. In historically cooler areas where climate change is driving exposures, investments in warning systems may be productive, whereas investments in health care and social services infrastructures are essential in historically hot regions where exposures are driven by population aging.

60 APPLIED LIFE SCIENCES↗

Towards A Theory of Autonomous Reconstitution of Compromised Cyber-Systems

The ability to maintain mission-critical operations in cyber-systems in the face of disruptions is critical. Faults in cyber systems can come from accidental sources (e.g., natural failure of a component) or deliberate sources (e.g., an intelligent adversary). Natural and intentional manipulation of data, computing, or coordination are the most impactful ways that an attacker can prevent an infrastructure from realizing its mission goals. Under these conditions, the ability to reconstitute critical infrastructure becomes important. Specifically, the question is: Given an intelligent adversary, how can cyber systems respond to keep critical infrastructure operational? In cyber systems, the distributed nature of the system poses serious difficulties in maintaining operations, in part due to the fact that a centralized command and control apparatus is unlikely to provide a robust framework for resilience. Resilience in cyber-systems, in general, has several components, and requires the ability to anticipate and withstand attacks or faults, as well as recover from faults and evolve the system to improve future resilience. The recovery effort (and any subsequent evolution) may require significant reconfiguration of the system (at all levels – hardware, software, services, permissions, etc.) if the system is to be made resilient to further attack or faults. This is especially important in the case of ongoing attacks, where reconfiguration decisions must be taken with care to avoid further compromising the system while maintaining continuity of operations. Collectively, we will label this recovery and evolution process as “reconstitution”. Currently, reconstitution is performed manually, generally after-the-fact, and usually consists of either standing up redundant systems, check-points (rolling back the configuration to a “clean” state), or re-creating the system using “gold-standard” copies. For enterprise systems, such reconstitution may be performed either directly on hardware, or using virtual machines. A significant challenge within this context is the ability to verify that the reconstitution is performed in a manner that renders the cyber-system resilient to ongoing and future attacks or faults. Fundamentally, the need is to determine optimal configuration of the cyber system when a fault is determined to be present. While existing theories for fault tolerance (for example, Byzantine fault tolerance) can guarantee resilience under certain conditions, in practice, these theories can break down in the face of an intelligent adversary. Further, it is difficult, in a dynamically evolving environment, to determine whether the necessary conditions for resilience have been met, resulting in difficulties in achieving resilient operation. In addition, existing theories do not sufficiently take into account the cost for attack and defense (the adversary is generally assumed to have infinite resources and time), hierarchy of importance (all network resources are assumed to be equally important), and the dynamic nature of some attacks (i.e., as the attack evolves, can resilience be maintained?). Alternative approaches to resilience based on a centralized command and control structure suffer from a single-point-failure. This paper presents preliminary research towards concepts for effective autonomous reconstitution of compromised cyber systems. We describe a mathematical framework as a first step towards a theoretical basis for autonomous reconstitution in dynamic cyber-system environments. We then propose formulating autonomous reconstitution as an optimization problem and describe some of the challenges associated with this formulation. This is followed by a brief discussion on potential solutions to these challenges.

asymmetric resilience↗

Review of the WECC EDT phase 2 EIM benefits analysis and results report.

A region-wide Energy Imbalance Market (EIM) was recently proposed by the Western Electricity Coordinating Council (WECC). In order for the Western Area Power Administration (Western) to make more informed decisions regarding its involvement in the EIM, Western asked Argonne National Laboratory (Argonne) to review the EIM benefits study (the October 2011 revision) performed by Energy and Environmental Economics, Inc. (E3). Key components of the E3 analysis made use of results from a study conducted by the National Renewable Energy Laboratory (NREL); therefore, we also reviewed the NREL work. This report examines E3 and NREL methods and models used in the EIM study. Estimating EIM benefits is very challenging because of the complex nature of the Western Interconnection (WI), the variability and uncertainty of renewable energy resources, and the complex decisions and potentially strategic bidding of market participants. Furthermore, methodologies used for some of the more challenging aspects of the EIM have not yet matured. This review is complimentary of several components of the EIM study. Analysts and modelers clearly took great care when conducting detailed simulations of the WI using well-established industry tools under stringent time and budget constraints. However, it is our opinion that the following aspects of the study and the interpretation of model results could be improved upon in future analyses. The hurdle rate methodology used to estimate current market inefficiencies does not directly model the underlying causes of sub-optimal dispatch and power flows. It assumes that differences between historical flows and modeled flows can be attributed solely to market inefficiencies. However, flow differences between model results and historical data can be attributed to numerous simplifying assumptions used in the model and in the input data. We suggest that alternative approaches be explored in order to better estimate the benefits of introducing market structures like the EIM. In addition to more efficient energy transactions in the WI, the EIM would reduce the amount of flexibility reserves needed to accommodate forecast errors associated with variable production from wind and solar energy resources. The modeling approach takes full advantage of variable resource diversity over the entire market footprint, but the projected reduction in flexibility reserves may be overly optimistic. While some reduction would undoubtedly occur, the EIM is only an energy market and would therefore not realize the same reduction in reserves as an ancillary services market. In our opinion the methodology does not adequately capture the impact of transmission constraints on the deployment of flexibility reserves. Estimates of flexibility reserves assume that forecast errors follow a normal distribution. Improved estimates could be obtained by using other probability distributions to estimate up and down reserves to capture the underlying uncertainty of these resources under specific operating conditions. Also, the use of a persistence forecast method for solar is questionable, because solar insolation follows a deterministic pattern dictated by the sun's path through the sky. We suggest a more rigorous method for forecasting solar insolation using the sun's relatively predictable daily pattern at specific locations. The EIM study considered only one scenario for hydropower resources. While this scenario is within the normal range over the WI footprint, it represents a severe drought condition in the Colorado River Basin from which Western schedules power. Given hydropower's prominent role in the WI, we recommend simulating a range of hydropower conditions since the relationship between water availability and WI dispatch costs is nonlinear. Also, the representation of specific operational constraints faced by hydropower operators in the WI needs improvements. The model used in the study cannot fully capture all of the EIM impacts and complexities of power system operations. In particular, a primary benefit of the EIM is a shorter dispatch interval; namely, 5 minutes. However, the model simulates the dispatch hourly. Therefore it cannot adequately measure the benefits of a more frequent dispatch. A tool with a finer time resolution would significantly improve simulation accuracy. When the study was conducted, the rules for the EIM were not clearly defined and it was appropriate to estimate societal benefits of the EIM assuming a perfect market without a detailed specification of the market design. However, incorporating a more complete description of market rules will allow for better estimates of EIM benefits. Furthermore, performing analyses using specific market rules can identify potential design flaws that may be difficult and expensive to correct after the market is established. Estimated cost savings from a more efficient dispatch are less than one percent of the total cost of electricity production.

14 SOLAR ENERGY↗

Thermal and electric multidomain dynamic model for integration of power grid distribution with behind-the-meter devices

As renewable energy sources like solar and wind power become more integrated into the grid, coordinated control of behind-the-meter devices is crucial for enhancing grid flexibility and reliability and for meeting cost targets, with standardized models being developed to support this transition. The increasing flexibility and uncertainty of integrated renewable energy grids, along with interactions between various subsystems, make traditional steady-state modeling insufficient to capture transient and dynamic behaviors. Current models (e.g., composite load and battery equivalent models) focus on thermodynamic or electrical characteristics but overlook critical electromechanical interactions. This limits the ability to share performance information for grid services and hampers fast dynamic simulations. In addition, motor stalling is usually triggered by a fault event and attributed to the characteristics of the mechanical torque of the motor, resulting in absorption of a large amount of reactive power during the stalling period. Further, this significant withdrawal of reactive power will deteriorate the dynamic voltage stability of power grids and cause delayed voltage recovery. Therefore, an in-depth modeling of the thermodynamics or mechanical torque is essential to study the impacts of the realistic torque characteristics of those behind-the-meter devices on power system voltage stability. This study developed a dynamic multidomain model for building HVAC systems, such as air-source heat pumps, to simulate their thermal and electrical responses to grid transients. The model can accurately predict power metrics with a mean absolute percentage error of 10%, by validating against with power system computer-aided design performance data. Case studies demonstrate the model capability of capturing the transient response to sudden voltage changes, rapid load fluctuations, and system shutdowns respectively. During a sudden voltage drop (30% for 0.1s), a fully loaded heat pump’s motor speed dropped, continued declining, and shut down after 3.6s, with severe power oscillations and a torque spike. A partially loaded unit experienced temporary oscillations but stabilized. Under higher building loads, compressor speed increased from 64% to 100%, with power and torque rising before stabilizing. In safety-triggered shutdowns, power decreased after minor fluctuations, and torque briefly spiked before dropping to zero.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Value of Demand Response: Quantities from Production Cost Modeling (Presentation)

Demand response (DR) resources present a potentially important source of grid flexibility particularly on future systems with high penetrations of variable wind and solar power generation. However, managed loads in grid models are limited by data availability and modeling complexity. This presentation focuses on the value of co-optimized DR resources to provide energy and ancillary services in a production cost model. There are significant variations in the availabilities of different types of DR resources, which affect both the operational savings as well as the revenue for each DR resource. The results presented include the system-wide avoided fuel and generator start-up costs as well as the composite revenue for each DR resource by energy and operating reserves. In addition, the revenue is characterized by the capacity, energy, and units of DR enabled.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Online Data Handling and Storage at the CMS Experiment

During the LHC Long Shutdown 1, the CMS Data Acquisition (DAQ) system underwent a partial redesign to replace obsolete network equipment, use more homogeneous switching technologies, and support new detector back-end electronics. The software and hardware infrastructure to provide input, execute the High Level Trigger (HLT) algorithms and deal with output data transport and storage has also been redesigned to be completely file- based. All the metadata needed for bookkeeping are stored in files as well, in the form of small documents using the JSON encoding. The Storage and Transfer System (STS) is responsible for aggregating these files produced by the HLT, storing them temporarily and transferring them to the T0 facility at CERN for subsequent offline processing. The STS merger service aggregates the output files from the HLT from ~62 sources produced with an aggregate rate of ~2GB/s. An estimated bandwidth of 7GB/s in concurrent read/write mode is needed. Furthermore, the STS has to be able to store several days of continuous running, so an estimated of 250TB of total usable disk space is required. In this article we present the various technological and implementation choices of the three components of the STS: the distributed file system, the merger service and the transfer system.

Andre, J. M.↗

SU-C-12A-01: Primary Vs. Scatter Contribution to Body CTDI: Experiment Results

Purpose: To quantify experimentally scatter contribution to CTDI in center and peripheral holes of the body (32-cm) phantom. Methods: All experiments were performed in Service Mode of 750CT-Discovery with both tube and table were in stationary position, and with large filter and 40- mm collimation. First, transmission through acrylic was measured using acrylic rods of various lengths (1-cm to 33-cm), at 80, 120, and 140 kVp. These data were utilized to obtain dose from primary beam at different depths of acrylic. Thus, scatter-to-primary ratio (SPR) was determined for center-hole by measuring exposure with a pencil chamber. For peripheral hole SPR, dose was measured at eight different tube angles from 0° to 180°. Change in primary dose with tube angle due to both shape of bowtie filter and distance from tube was measured in air; hence, dose from primary from each of the 8 phantom measurements was determined and SPR was calculated by integrating the fitted models for primary and scatter distributions as a function of distance from tube. Also, scatter contribution from different segments of phantom to center-hole dose was measured using a custom-built acrylic phantom, which had similar SPR at the center-hole to that of standard body phantom. Results: After correcting for stray radiation (off-focus, scatter from collimators, etc.) for primary measurements, preliminary results of SPRs in center-hole dose of the body phantom for 80, 120, and 140 kVp were 6.8, 6.2, and 6.0, respectively, and for peripheral hole were 1.45, 1.44, and 1.39. Forward-scatter and backscatter contributions to center dose, at any point during tube rotation, were respectively, 62% and 38% with 80 kVp, and 60% and 40% with 120 and 140 kVp. Conclusion: SPR in both center and peripheral holes of body CTDI phantom was determined experimentally. Also, distribution of contributing scatter to center hole was estimated.

60 APPLIED LIFE SCIENCES↗

Hamilton: Flexible, Open Source $10 Wireless Sensor System for Energy Efficient Building Operation

Sensors for improving building performance are rapidly populating the market, driven in part by the drive to reduce greenhouse gas emissions resulting from energy production as well as improve the interior environment for healthy and more productive spaces. UC Berkeley has led wireless sensor development over the past 25 years (e.g., Telos mote), with the Hamilton (named after Alexander Hamilton on the US $10 bill) as the most recent. The Hamilton sensor was designed as a low-cost high-performance sensor that is modular and interoperable. The objective of the Hamilton project was to create, evaluate and establish the technological foundations for secure and easy to deploy building energy efficiency applications utilizing pervasive, low-cost wireless sensors integrated with traditional Building Management Systems (BMS), consumer-sector building components, and powerful data analytics. The project included iterative hardware design, incorporating a high-performance database (BTrDb, http://btrdb.io/), creating and iterating the development of secure data middleware (BOSSwave, WAVE/WAVEMQ), working with and pushing the development of an open-source tiny operating system RiotOS, and implementing and improving protocols such as Thread/OpenThread and TCP/IP. The hardware benefited from careful design to drive down the cost; the design included a System-on-a-Chip (SoC), chip antenna, single crystal and five passive components. Careful design of the operating system created a low-power design to enable a long life with small batteries. The hardware included several sensors: temperature, radiant temperature, relative humidity, magnetometer, accelerometer, and light, with an optional occupancy (Passive InfraRed) sensor. The project was the basis of several applications, both internal to the research team and other researchers and professionals at other institutions. Several applications used the sensor hardware as the basis for other complex devices. Other applications used the sensors to improve building performance through interoperating with the building Heating Ventilation and Air-Conditioning (HVAC) system, such as using occupancy and/or distributed temperature sensing to reduce HVAC zone energy while still providing thermal comfort and to reduce peak loads in small commercial buildings. We demonstrated cloud-based energy analytics, implemented a schedule and a Model Predictive Controller in a small commercial building to optimize HVAC energy, occupancy and electricity price. Initial integration of these technological innovations was performed through the creation of execution containers containing the WAVE agent and various driver, proxy, or building system function logic. The research added to the understanding of efficient sensor hardware, secure middleware, time-series data management (high performance database), efficient communication protocols, and interoperating with applications and building systems. The project showed the technical effectiveness and economic feasibility of creating a low-cost, modular, and easy-to-deploy sensor. Through conversations with multiple end users, the research team discovered that many customers wanted data management and services in addition to the sensors. HamiltonIOT developed packages of sensors, border router, and data services to provide a seamless “plug-and-play” sensor deployment. Some customers were willing to pay for higher quality sensors (such as light); some customers wanted a robust enclosure (waterproof).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparing multi-source urban flood indicators: satellite, simulation, and citizen-reported data

Urban flooding arises from complex mechanisms, making it challenging to capture accurately with a single detection method. This study evaluates three complementary approaches to detect flooding across three Chicago neighborhoods: (i) Sentinel-1 synthetic aperture radar (SAR), offering weather-independent, high-resolution (10 m) imagery of surface inundation; (ii) the storm water management model (SWMM), simulating combined sewer overflow and drainage performance; and (iii) citizen-generated 311 service requests, capturing observed flooding impacts. By analyzing six storms ranging from severe to mild, we examine how each source uniquely contributes to identifying urban flood events. SAR imagery effectively identifies standing water but can miss brief flooding due to satellite revisit constraints. SWMM provides detailed insights into system-wide drainage behavior yet may underestimate localized street-level flooding. Meanwhile, 311 calls reflect real-world flooding impacts but are vulnerable to underreporting. Statistical overlap analysis highlights chronic flood hotspots repeatedly identified across multiple detection methods, indicating persistent infrastructure and topographic vulnerabilities. Temporal analysis further reveals that while SWMM flooding aligns closely with rainfall peaks, 311 calls typically precede or persist beyond these peaks. Our findings emphasize the value of using satellite observations, hydrological modeling, and resident-reported data in a complementary manner to better interpret patterns in flood timing, severity, and spatial distribution—providing insights that can inform targeted infrastructure improvements and contribute to urban flood resilience planning.

311↗