Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detector Readout”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

First experimental feasibility study of VIPIC: a custom-made detector for X-ray speckle measurements

The Vertically Integrated Photon Imaging Chip (VIPIC) was custom-designed for X-ray photon correlation spectroscopy, an application in which occupancy per pixel is low but high time resolution is needed. VIPIC operates in a sparsified streaming mode in which each detected photon is immediately read out as a time- and position-stamped event. This event stream can be fed directly to an autocorrelation engine or accumulated to form a conventional image. The detector only delivers non-zero data (sparsified readout), greatly reducing the communications overhead typical of conventional frame-oriented detectors such as charge-coupled devices or conventional hybrid pixel detectors. This feature allows continuous acquisition of data with timescales from microseconds to hours. In this work VIPIC has been used to measure X-ray photon correlation spectroscopy data on polystyrene latex nano-colliodal suspensions in glycerol and on colloidal suspensions of silica spheres in water. Relaxation times of the nano-colloids have been measured for different temperatures. These results demonstrate that VIPIC can operate continuously in the microsecond time frame, while at the same time probing longer timescales.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reducing the Read Noise of HAWAII-2RG Detector Systems with Improved Reference Sampling and Subtraction (IRS2)

IRS2 is a Wiener-optimal approach to using all of the reference information that Teledyne's HAWAII-2RG detector arrays provide. Using a new readout pattern, IRS2 regularly interleaves reference pixels with the normal pixels during readout. This differs from conventional clocking, in which the reference pixels are read out infrequently, and only in a few rows and columns around the outside edges of the detector array. During calibration, the data are processed in Fourier space, which is <;:lose to the noise's eigenspace. Using IRS2, we have reduced the read noise of the James Webb Space Telescope Near Infrared Spectrograph by 15% compared to conventional readout. We are attempting to achieve further gains by calibrating out recently recognized non-stationary noise that appears at the frame rate.

Rauscher, Bernard J.↗

Development of Readout Interconnections for the Si-W Calorimeter of SiD

The SiD collaboration is developing a Si-W sampling electromagnetic calorimeter, with anticipated application for the International Linear Collider. Assembling the modules for such a detector will involve special bonding technologies for the interconnections, especially for attaching a silicon detector wafer to a flex cable readout bus. We review the interconnect technologies involved, including oxidation removal processes, pad surface preparation, solder ball selection and placement, and bond quality assurance. Our results show that solder ball bonding is a promising technique for the Si-W ECAL, and unresolved issues are being addressed.

43 PARTICLE ACCELERATORS↗

Cryogenic electronics for noble liquid neutrino detectors

In this paper we present the general features of cryogenic (or “cold”) electronics for noble liquid time projection chambers, with design principles and details for neutrino physics, a brief history of the technology and details of recent research and development that is driving the design of the detectors under construction. Finally, some comments on future R&D envisioned and the impact of this work on other fields is described. “Cold” in the context of this work applies to CMOS devices operated at 77 K and above, at liquids temperatures of LAr (89 K), LKr (125 K) and LXe (165 K), with most of the tests performed in, or at LN 2 (77 K). Additionally, the paper is concentrated on the design of cold electronics for large liquid argon TPCs, those that have been successfully operated, MicroBooNE and ProtoDUNE, and those designed or under construction, such as SBND and DUNE first and second 10 kton modules. The high performance achieved with MicroBooNE and ProtoDUNE – a high signal-to-noise ratio combined with high stability of response – is mainly due to the integral approach to design and construction of sensing electrodes with cold readout electronics in a modular approach with the cryostat signal feed-throughs incorporating warm interface electronics into a Faraday cage with the cryostat. The integral concept is described in some detail in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of ASIC-based signal readout electronics for LEGEND-1000

LEGEND, the Large Enriched Germanium Experiment for Neutrinoless ββ Decay, is a ton-scale experimental program to search for neutrinoless double beta (0νββ) decay in the isotope 76 Ge with an unprecedented sensitivity. Building on the success of the low-background 76 Ge-based GERDA and Majorana Demonstrator experiments, the LEGEND collaboration is targeting a signal discovery sensitivity beyond 10 28 yr on the decay half-life with approximately 10 t∙yr of exposure. Signal readout electronics in close proximity to the detectors plays a major role in maximizing the experiment's discovery sensitivity by reducing electronic noise and improving pulse shape analysis capabilities for the rejection of backgrounds. However, the proximity also poses unique challenges for the radiopurity of the electronics. Application-specific integrated circuit (ASIC) technology allows the implementation of the entire charge sensitive amplifier (CSA) into a single low-mass chip while improving the electronic noise and reducing the power consumption. In this work, we investigated the properties and electronic performance of a commercially available ASIC CSA, the XGLab CUBE preamplifier, together with a p-type point contact high-purity germanium detector. We show that low noise levels and excellent energy resolutions can be obtained with this readout. Moreover, we demonstrate the viability of pulse shape discrimination techniques for reducing background events.

47 OTHER INSTRUMENTATION↗

Large-Angle Rocking Beam Electron Diffraction of Large Unit Cell Crystals Using Direct Electron Detector

We report a large-angle rocking beam electron diffraction (LARBED) technique for electron diffraction analysis. Diffraction patterns are recorded in a scanning transmission electron microscope (STEM) using a direct electron detector with large dynamical range and fast readout. We use a nanobeam for diffraction and perform the beam double rocking by synchronizing the detector with the STEM scan coils for the recording. Using this approach, large-angle convergent beam electron diffraction (LACBED) patterns of different reflections are obtained simultaneously. By using a nanobeam, instead of a focused beam, the LARBED technique can be applied to beam-sensitive crystals as well as crystals with large unit cells. Here, this paper describes the implementation of LARBED and evaluates the performance using silicon and gadolinium gallium garnet crystals as test samples. We demonstrate that our method provides an effective and robust way for recording LARBED patterns and paves the way for quantitative electron diffraction of large unit cell and beam-sensitive crystals.

4DSTEM↗

Results from the DUNE ND-LAr 2x2 Demonstrator Run 2

The Deep Underground Neutrino Experiment (DUNE) is a cutting-edge, long-baseline experiment under construction in the United States, based on large liquid-argon time projection chambers (LArTPCs). The DUNE Near Detector LArTPC (ND-LAr) will employ a novel modular architecture using a pixelated LArPix charge readout. To validate this design and characterize detector response, the 2×2 demonstrator—an array of eight optically isolated LArTPC modules—was deployed at Fermilab in 2024. During winter 2025, the 2x2 demonstrator was operated for a second data-taking campaign (Run 2) with the aim of studying the low-energy response of the detector. Run 2 focused on calibration and response studies using a suite of deployed radioactive sources. Gamma sources (²²Na, ⁶⁰Co, and ⁸⁸Y) were used to probe module-to-module performance variations, energy resolution, and calibrations. Neutron sources (AmBe and a pulsed neutron generator) enabled studies of neutron interactions in liquid argon, including inelastic scatters and neutron capture signals, relevant for low-energy backgrounds and detector modeling. In addition, the detector was doped with ²²⁰Rn, providing Bi–Po coincidence signals that allow precise calibration of the charge and scintillation response. This poster will present results from these calibration campaigns. These studies provide critical validation of the ND-LAr modular LArTPC concept and inform calibration and reconstruction strategies for the full DUNE near detector.

Mora-Lepin, Luis [Florida State U.] (ORCID:0000000↗

AR-NE3A, a New Macromolecular Crystallography Beamline for Pharmaceutical Applications at the Photon Factory

Recent advances in high-throughput techniques for macromolecular crystallography have highlighted the importance of structure-based drug design (SBDD), and the demand for synchrotron use by pharmaceutical researchers has increased. Thus, in collaboration with Astellas Pharma Inc., we have constructed a new high-throughput macromolecular crystallography beamline, AR-NE3A, which is dedicated to SBDD. At AR-NE3A, a photon flux up to three times higher than those at existing high-throughput beams at the Photon Factory, AR-NW12A and BL-5A, can be realized at the same sample positions. Installed in the experimental hutch are a high-precision diffractometer, fast-readout, high-gain CCD detector, and sample exchange robot capable of handling more than two hundred cryo-cooled samples stored in a Dewar. To facilitate high-throughput data collection required for pharmaceutical research, fully automated data collection and processing systems have been developed. Thus, sample exchange, centering, data collection, and data processing are automatically carried out based on the user's pre-defined schedule. Although Astellas Pharma Inc. has a priority access to AR-NE3A, the remaining beam time is allocated to general academic and other industrial users.

43 PARTICLE ACCELERATORS↗

Time projection chamber for GADGET II

The established Gaseous Detector with Germanium Tagging (GADGET) detection system is used to measure weak, low-energy 𝛽-delayed proton decays. It consists of the Gaseous Proton Detector equipped with a MICROMEGAS (MM) readout to detect protons and other charged particles calorimetrically, surrounded by the Segmented Germanium Array (SeGA) for high-resolution detection of prompt 𝛾 rays. To upgrade GADGET's Proton Detector to operate as a compact time projection chamber (TPC) for the detection, three-dimensional imaging and identification of low-energy 𝛽-delayed single- and multiparticle emissions mainly of interest to astrophysical studies. A new high granularity MM board with 1024 pads has been designed, fabricated, installed, and tested. A high-density data acquisition system based on generic electronics for TPCs (GET) has been installed and optimized to record and process the gas avalanche signals collected on the readout pads. The TPC's performance has been tested using a 220 Rn 𝛼-particle source and cosmic-ray muons. In addition, decay events in the TPC have been simulated by adapting the attpcroot data analysis framework. Furthermore, a novel application of two-dimensional convolutional neural networks for GADGET II event classification is introduced. The optimization of data throughput is also addressed. The GADGET II TPC is capable of detecting and identifying 𝛼 particles as well as measuring their track direction, range, and energy. The extracted energy resolution of the GADGET II TPC using P10 gas is about 5.4% at 6.288 MeV ( 220 Rn 𝛼 events), computed using charge integration. Based on a systematic simulation study, we estimated the detection efficiency of the GADGET II TPC for protons and 𝛼 particles, respectively. It has also been demonstrated that the GADGET II TPC is capable of tracking minimum-ionizing particles (i.e., cosmic-ray muons). From these measurements, the electron drift velocity was measured under typical operating conditions. In addition to being one of the first generation of micropattern gaseous detectors (MPGDs) to utilize a resistive anode applied to low-energy nuclear physics, the GADGET II TPC will also be the first TPC surrounded by a high-efficiency array of high-purity germanium 𝛾-ray detectors. As a result, the TPC of GADGET II has been designed, fabricated, and tested and is ready for operation at the Facility for Rare Isotope Beams for radioactive-beam-line experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design of Low Power CMOS Read-Out with TDI Function for Infrared Linear Photodiode Array Detectors

A new low voltage CMOS infrared readout circuit using the buffer-direct injection method is presented. It uses a single supply voltage of 1.8 volts and a bias current of 1uA. The time-delay integration technique is used to increase the signal to noise ratio. A current memory circuit with faulty diode detection is used to remove dark current for background compensation and to disable a photodiode in a cell if detected as faulty. Simulations are shown that verify the circuit that is currently in fabrication in 0.5ym CMOS technology.

Vizcaino, Paul↗

Gamma ray spectroscopy employing divalent europium-doped alkaline earth halides and digital readout for accurate histogramming

A scintillator radiation detector system according to one embodiment includes a scintillator; and a processing device for processing pulse traces corresponding to light pulses from the scintillator, wherein pulse digitization is used to improve energy resolution of the system. A scintillator radiation detector system according to another embodiment includes a processing device for fitting digitized scintillation waveforms to an algorithm based on identifying rise and decay times and performing a direct integration of fit parameters. A method according to yet another embodiment includes processing pulse traces corresponding to light pulses from a scintillator, wherein pulse digitization is used to improve energy resolution of the system. A method in a further embodiment includes fitting digitized scintillation waveforms to an algorithm based on identifying rise and decay times; and performing a direct integration of fit parameters. Additional systems and methods are also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high frequency resonance gravity gradiometer

A new setup OGRAN—the large scale opto-acoustical gravitational detector is described. As distinguished from known gravitational bar detectors it uses the optical interferometrical readout for registering weak variations of gravity gradient at the kilohetz frequency region. At room temperature, its sensitivity is limited only by the bar Brownian noise at the bandwidth close to 100 Hz. It is destined for a search for rare events—gravitational pulses coincident with signals of neutrino scintillator (BUST) in the deep underground of Baksan Neutrino Observatory of INR RAS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the CMS Endcap Timing Layer readout chip prototype with charge injection

We present the characterization of a readout Application-Specific Integrated Circuit (ASIC) for the CMS Endcap Timing Layer (ETL) of the High-Luminosity LHC upgrade with charge injection. The ASIC, named ETROC and developed in a 65 nm CMOS technology, reads out a 16× 16 pixel matrix of the Low-Gain Avalanche Detector (LGAD). The jitter contribution from ETROC is required to be below 40 ps to achieve the 50 ps overall time resolution per hit. The analog readout circuits in ETROC consist of the preamplifier and the discriminator. The preamplifier handles the LGAD charge signal with the most probable value of around 15 fC. The discriminator generates the digital pulse, which provides the Time-Of-Arrival (TOA, leading edge) and Time-Over-Threshold (TOT, pulse width) information. The prototype of ETROC (ETROC0) that implements a single channel of analog readout circuits has been evaluated with charge injection. The jitter of the analog readout circuits, measured from the discriminator's leading edge, is better than 16 ps for a charge larger than 15 fC with the sensor capacitance. The time walk resulting from different pulse heights can be corrected using the TOT measurement. The time resolution distribution has a standard deviation of 29 ps after the time-walk correction from the charge injection. At room temperature, the preamplifier's power consumption is measured to be 0.74 mW and 1.53 mW per pixel in the low- and high-power mode, respectively. Finally, the measured power consumption of the discriminator is 0.84 mW per pixel. With the ASIC alone or the LGAD sensor, The characterization performances fulfill the ETL's challenging requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The SciBooNE Data Acquisition System

SciBooNE started in June 2007 primarily to study neutrino and anti-neutrino interactions in the energy region below 1 GeV. The SciBooNE detector is located in Booster Neutrino Beamline at Fermi National Accelerator Laboratory. The SciBooNE data aquisition system consists of the readout software and an event builder, which collects data from each detector component (SciBar detector, an electromagnetic calorimeter, Muon Range Detector and GPS). The typical DAQ readout time per trigger is 20 ms, which is fast enough to take every beam spill. The system is also very stable and the probability of missing a beam spill due to the readout time is less than 0.002 %.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CHANDRA DETECTION OF EXTENDED X-RAY EMISSION FROM THE RECURRENT NOVA RS OPHIUCHI

Radio, infrared, and optical observations of the 2006 eruption of the symbiotic recurrent nova RS Ophiuchi showed that the explosion produced non-spherical ejecta. Some of this ejected material was in the form of bipolar jets to the east and west of the central source. Here we describe X-ray observations taken with the Chandra X-ray Observatory one and a half years after the beginning of the outburst that reveal narrow, extended structure with a position angle of approximately 300 deg. (east of north). Although the orientation of the extended feature in the X-ray image is consistent with the readout direction of the CCD detector, extensive testing suggests that the feature is not an artifact. Assuming it is not an instrumental effect, the extended X-ray structure shows hot plasma stretching more than 1900 AU from the central binary (taking a distance of 1.6 kpc). The X-ray emission is elongated in the northwest direction-in line with the extended infrared emission and some minor features in the published radio image. It is less consistent with the orientation of the radio jets and the main bipolar optical structure. Most of the photons in the extended X-ray structure have energies of less than 0.8 keV. If the extended X-ray feature was produced when the nova explosion occurred, then its 1.''2 length as of 2007 August implies that it expanded at an average rate of more than 2 mas day{sup -1}, which corresponds to a flow speed of greater than 6000 km s{sup -1} (days/1.6 kpc) in the plane of the sky. This expansion rate is similar to the earliest measured expansion rates for the radio jets.

79 ASTRONOMY AND ASTROPHYSICS↗

A new technique to characterize CT scanner bow-tie filter attenuation and applications in human cadaver dosimetry simulations

Purpose: To present a noninvasive technique for directly measuring the CT bow-tie filter attenuation with a linear array x-ray detector. Methods: A scintillator based x-ray detector of 384 pixels, 307 mm active length, and fast data acquisition (model X-Scan 0.8c4-307, Detection Technology, FI-91100 Ii, Finland) was used to simultaneously detect radiation levels across a scan field-of-view. The sampling time was as short as 0.24 ms. To measure the body bow-tie attenuation on a GE Lightspeed Pro 16 CT scanner, the x-ray tube was parked at the 12 o’clock position, and the detector was centered in the scan field at the isocenter height. Two radiation exposures were made with and without the bow-tie in the beam path. Each readout signal was corrected for the detector background offset and signal-level related nonlinear gain, and the ratio of the two exposures gave the bow-tie attenuation. The results were used in the GEANT4 based simulations of the point doses measured using six thimble chambers placed in a human cadaver with abdomen/pelvis CT scans at 100 or 120 kV, helical pitch at 1.375, constant or variable tube current, and distinct x-ray tube starting angles. Results: Absolute attenuation was measured with the body bow-tie scanned at 80–140 kV. For 24 doses measured in six organs of the cadaver, the median or maximum difference between the simulation results and the measurements on the CT scanner was 8.9% or 25.9%, respectively. Conclusions: The described method allows fast and accurate bow-tie filter characterization.

60 APPLIED LIFE SCIENCES↗