Search NASA⌕ Search

SEARCH · Search NASA

Results for “Elemental analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Thermal Analysis of a 100 kW Polyphase Wireless Power Transfer System

Charging Electric Vehicles (EVs) fast and safely has a crucial role in the future of the EV technology. High-power Wireless Power Transfer (WPT) helps to significantly decrease the charging time. However, when the power transfer levels increase, thermal management becomes a significant challenge. The thermal design of the WPT systems needs more consideration in the design and implementation steps. This paper presents a thermal analysis of a 100 kW high-power WPT system. The thermal performance of the proposed design was evaluated at different power levels by considering the magnetic design and loss analysis. Finite Element Analysis (FEA) of the proposed design was performed and the thermal images of the implemented system were taken to prove the simulation results. The results show that, a liquid cooling design is needed for a high-power WPT systems for the long-time continuous operations of the charging pads.

Aydin, Emrullah↗

Oxidation Behavior of Zirconium Diboride Nanoparticles

The products of oxidation of ZrB{sub 2} powders with average particle sizes of ~100 and ~30 nm by atmospheric oxygen under isothermal conditions and during heating have been characterized by thermal analysis, X-ray diffraction, scanning electron microscopy, IR frustrated total internal reflection spectroscopy, energy dispersive X-ray analysis, and elemental analysis. The oxidation onset has been observed at 594 and 396°C, respectively. Oxidation at temperatures of ≥800°C leads to the formation of boron oxide and monoclinic ZrO{sub 2}, independent of the particle size of ZrB{sub 2}. The reaction rate constants for the oxidation of ZrB{sub 2} nanoparticles ~100 and ~30 nm in size have been determined to be 0.03, 0.15, and 0.31 h{sup –1} at 600, 650, and 700°C and 0.11, 0.35, and 0.81 h{sup –1} at 500, 600, and 700°C, respectively. The apparent activation energies for the oxidation of the ZrB{sub 2} nanoparticles ~100 and ~30 nm in size are 161 ± 4 and 62 ± 3 kJ/mol, respectively, as evaluated from the temperature dependence of the rate constants at the above temperatures.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Omega3P: A Parallel Finite-Element Eigenmode Analysis Code for Accelerator Cavities

Omega3P is a parallel eigenmode calculation code for accelerator cavities in frequency domain analysis using finite-element methods. In this report, we will present detailed finite-element formulations and resulting eigenvalue problems for lossless cavities, cavities with lossy materials, cavities with imperfectly conducting surfaces, and cavities with waveguide coupling. We will discuss the parallel algorithms for solving those eigenvalue problems and demonstrate modeling of accelerator cavities through different examples.

43 PARTICLE ACCELERATORS↗

Study on prestressed concrete reactor vessel structures. II-5: Crack analysis by three dimensional finite elements method of 1/20 multicavity type PCRV subjected to internal pressure

A three-dimensional finite elements analysis is reported of the nonlinear behavior of PCRV subjected to internal pressure by comparing calculated results with test results. As the first stage, an analysis considering the nonlinearity of cracking in concrete was attempted. As a result, it is found possible to make an analysis up to three times the design pressure (50 kg/sqcm), and calculated results agree well with test results.

Source record↗

Simulation of Complex Cracking in Plain Weave C/SiC Composite under Biaxial Loading

Finite element analysis is performed on a mesh, based on computed geometry of a plain weave C/SiC composite with assumed internal stacking, to reveal the pattern of internal damage due to biaxial normal cyclic loading. The simulation encompasses intertow matrix cracking, matrix cracking inside the tows, and separation at the tow-intertow matrix and tow-tow interfaces. All these dissipative behaviors are represented by traction-separation cohesive laws. Not aimed at quantitatively predicting the overall stress-strain relation, the simulation, however, does not take the actual process of fiber debonding into account. The fiber tows are represented by a simple rule-of-mixture model where the reinforcing phase is a hypothetical one-dimensional material. Numerical results indicate that for the plain weave C/SiC composite, 1) matrix-crack initiation sites are primarily determined by large intertow matrix voids and interlayer tow-tow contacts, 2) the pattern of internal damage strongly depends on the loading path and initial stress, 3) compressive loading inflicts virtually no damage evolution. KEY WORDS: ceramic matrix composite, plain weave, cohesive model, brittle failure, smeared crack model, progressive damage, meso-mechanical analysis, finite element.

Cheng, Ron-Bin↗

Process Improvement Through Tool Integration in Aero-Mechanical Design

Emerging capabilities in commercial design tools promise to significantly improve the multi-disciplinary and inter-disciplinary design and analysis coverage for aerospace mechanical engineers. This paper explores the analysis process for two example problems of a wing and flap mechanical drive system and an aircraft landing gear door panel. The examples begin with the design solid models and include various analysis disciplines such as structural stress and aerodynamic loads. Analytical methods include CFD, multi-body dynamics with flexible bodies and structural analysis. Elements of analysis data management, data visualization and collaboration are also included.

Integrated design and analysis↗

Predicting Ductility and Failure Modes of TRIP Steels under Different Loading Conditions

We study the ultimate ductility and failure modes of a TRIP (TRansformation-Induced Plasticity) 800 steel under different loading conditions with an advanced micromechanics-based finite element analysis. The representative volume element (RVE) for the TRIP800 under examination is developed based on an actual microstructure obtained from scanning electron microscopy (SEM). The evolution of retained austenite during deformation process and the mechanical properties of the constituent phases of the TRIP800 steel are obtained from the synchrotron-based in-situ high-energy X-ray diffraction (HEXRD) experiments and a self-consistent (SC) model. The ductile failure of the TRIP800 under different loading conditions is predicted in the form of plastic strain localization without any prescribed failure criteria for the individual phases. Comparisons of the computational results with experimental measurements suggest that the microstructure-based finite element analysis can well capture the overall macroscopic behavior of the TRIP800 steel under different loading conditions. The methodology described in this study may be extended for studying the ultimate ductile failure mechanisms of TRIP steels as well as the effects of the various processing parameters on the macroscopic behaviors of TRIP steels.

36 MATERIALS SCIENCE↗

Radiolytic Damage and Hydrogen Generation at Carbide – Water Interfaces

To understand the performance of carbides under irradiation, the behavior of SiC and ZrC as well as water slurries of these carbides have been systematically studied using gamma-rays and 5.5 MeV He ions. Radiolytic damage to the carbides was determined using a range of analytical techniques including thermogravimetric analysis (TGA), elemental analysis, inductively-coupled plasma optical emission spectroscopy (ICP-OES) and scanning electron microscopy-energy dispersive X-ray spectroscopy (SEM-EDS).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SU-F-207-05: Excess Heat Corrections in a Prototype Calorimeter for Direct Realization of CT Absorbed Dose to Phantom

Purpose: To reconcile air kerma and calorimetry measurements in a prototype calorimeter for obtaining absorbed dose in diagnostic CT beams. While corrections for thermal artifacts are routine and generally small in calorimetry of radiotherapy beams, large differences in relative stopping powers of calorimeter materials at the lower energies typical of CT beams greatly magnify their effects. Work-to-date on the problem attempts to reconcile laboratory measurements with modeling output from Monte Carlo and finite-element analysis of heat transfer. Methods: Small thermistor beads were embedded in a polystyrene (PS) core element of 1 cm diameter, which was inserted into a cylindrical HDPE phantom of 30 cm diameter and subjected to radiation in a diagnostic CT x-ray imaging system. Resistance changes in the thermistors due to radiation heating were monitored via lock-in amplifier. Multiple 3-second exposures were recorded at 8 different dose-rates from the CT system, and least-squares fits to experimental data were compared to an expected thermal response obtained by finite-element analysis incorporating source terms based on semi-empirical modeling and Monte Carlo simulation. Results: Experimental waveforms exhibited large thermal artifacts with fast time constants, associated with excess heat in wires and glass, and smaller steps attributable to radiation heating of the core material. Preliminary finite-element analysis follows the transient component of the signal qualitatively, but predicts a slower decay of temperature spikes. This was supplemented by non-linear least-squares fits incorporating semi-empirical formulae for heat transfer, which were used to obtain dose-to-PS in reasonable agreement with the output of Monte Carlo calculations that converts air kerma to absorbed dose. Conclusion: Discrepancies between the finite-element analysis and our experimental data testify to the very significant heat transfer correction required for absorbed dose calorimetry of diagnostic CT beams. The results obtained here are being used to refine both simulations and design of calorimeter core components.

60 APPLIED LIFE SCIENCES↗

Calculation of skin-stiffener interface stresses in stiffened composite panels

A method for computing the skin-stiffener interface stresses in stiffened composite panels is developed. Both geometrically linear and nonlinear analyses are considered. Particular attention is given to the flange termination region where stresses are expected to exhibit unbounded characteristics. The method is based on a finite-element analysis and an elasticity solution. The finite-element analysis is standard, while the elasticity solution is based on an eigenvalue expansion of the stress functions. The eigenvalue expansion is assumed to be valid in the local flange termination region and is coupled with the finite-element analysis using collocation of stresses on the local region boundaries. Accuracy and convergence of the local elasticity solution are assessed using a geometrically linear analysis. Using this analysis procedure, the influence of geometric nonlinearities and stiffener parameters on the skin-stiffener interface stresses is evaluated.

Cohen, David↗

Characteristics of Three-Node Smoothing Element under Penalty Constraints

The project is based upon research of Tessler et al. (1994) on an improved variational formulation for post-processing stress predictions in Finite Element Analysis. The methodology, called Smoothing Element Analysis (SEA), employs a three-node smoothing finite element. The present effort focused on verifying the basic constant strain criterion for the three-node smoothing element subject to a set of internal penalty constraints. The convergence characteristics of the element are assessed by first deriving the constrained form of the assumed element stress and stress gradient fields, and then by verifying the validity of the constant strain criterion once the element penalty constraints are explicitly imposed. The analytical investigation is carried out with the use of the symbolic manipulation code 'Mathematica'.

Sobel, Seth S.↗

Finite-Element Composite-Analysis Program

Finite Element Composite Analysis Program, FECAP, special-purpose finite-element program for analyzing behavior of composite material with microcomputer. Procedure leads to set of linear simultaneous equations relating unknown nodal displacement to applied loads. Written in HP BASIC 3.0.

Bowles, David E.↗

A Six-Node Curved Triangular Element and a Four-Node Quadrilateral Element for Analysis of Laminated Composite Aerospace Structures

Mathematical development and some computed results are presented for Mindlin plate and shell elements, suitable for analysis of laminated composite and sandwich structures. These elements use the conventional 3 (plate) or 5 (shell) nodal degrees of freedom, have no communicable mechanisms, have no spurious shear energy (no shear locking), have no spurious membrane energy (no membrane locking) and do not require arbitrary reduction of out-of-plane shear moduli or under-integration. Artificial out-of-plane rotational stiffnesses are added at the element level to avoid convergence problems or singularity due to flat spots in shells. This report discusses a 6-node curved triangular element and a 4-node quadrilateral element. Findings show that in regular rectangular meshes, the Martin-Breiner 6-node triangular curved shell (MB6) is approximately equivalent to the conventional 8-node quadrilateral with integration. The 4-node quadrilateral (MB4) has very good accuracy for a 4-node element, and may be preferred in vibration analysis because of narrower bandwidth. The mathematical developments used in these elements, those discussed in the seven appendices, have been applied to elements with 3, 4, 6, and 10 nodes and can be applied to other nodal configurations.

Martin, C. Wayne↗

CFD Methods and Tools for Multi-Element Airfoil Analysis

This lecture will discuss the computational tools currently available for high-lift multi-element airfoil analysis. It will present an overview of a number of different numerical approaches, their current capabilities, short-comings, and computational costs. The lecture will be limited to viscous methods, including inviscid/boundary layer coupling methods, and incompressible and compressible Reynolds-averaged Navier-Stokes methods. Both structured and unstructured grid generation approaches will be presented. Two different structured grid procedures are outlined, one which uses multi-block patched grids, the other uses overset chimera grids. Turbulence and transition modeling will be discussed.

Rogers, Stuart E.↗

Bolt clampup relaxation in a graphite/epoxy laminate

A simple bolted joint was analyzed to calculate bolt clampup relaxation for a graphite/epoxy (T300/5208) laminate. A viscoelastic finite element analysis of a double-lap joint with a steel bolt was conducted. Clampup forces were calculated for various steady-state temperature-moisture conditions using a 20-year exposure duration. The finite element analysis predicted that clampup forces relax even for the room-temperature-dry condition. The relaxations were 8, 13, 20, and 30 percent for exposure durations of 1 day, 1 month, 1 year, and 20 years, respectively. As expected, higher temperatures and moisture levels each increased the relaxation rate. The combined viscoelastic effects of steady-state temperature and moisture appeared to be additive. From the finite-element analysis, a simple equation was used to calculate clampup forces for the same temperature-moisture conditions as used in the finite-element analysis. The two sets of calculated results agreed well. Previously announced in STAR as N82-19320

Shivakumar, K. N.↗

Bolt clampup relaxation in a graphite/epoxy laminate

A simple bolted joint was analyzed to calculate bolt clampup relaxation for a graphite/epoxy (T300/5208) laminate. A viscoelastic finite element analysis of a double-lap joint with a steel bolt was conducted. Clampup forces were calculated for various steady-state temperature-moisture conditions using a 20-year exposure duration. The finite element analysis predicted that clampup forces relax even for the room-temperature-dry condition. The relaxations were 8, 13, 20, and 30 percent for exposure durations of 1 day, 1 month, 1 year, and 20 years, respectively. As expected, higher temperatures and moisture levels each increased the relaxation rate. The combined viscoelastic effects of steady-state temperature and moisture appeared to be additive. From the finite-element analysis, a simple equation was developed for clampup force relaxation. This generalized equation was used to calculate clampup forces for the same temperature-moisture conditions as used in the finite-element analysis. The two sets of calculated results agreed well.

Shivakumar, K. N.↗

Elemental and isotopic analysis of inorganic salts by laser desorption ionization mass spectrometry

Laser desorption ionization mass spectrometry is applied for the analysis of elements as well as their isotopic composition in different inorganic salts. At very low laser energies the inorganic ions are desorbed and ionized from the thin layer of the sample surface. The naturally occurring isotopes of alkali and silver ions are resolved using time of flight mass spectrometer. Further increase in laser energy shows the appearance of Al, Cr, and Fe ions in the mass spectra. This indicates the penetration laser beam beyond the sample surface leading to the ablation of sample target at higher energies. The simultaneous appearance of atomic ions from the sample target at relatively higher laser energies hampers the unambiguous identification of amino acid residues from the biomolecular ions in MALDI-MS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗