Search NASA⌕ Search

SEARCH · Search NASA

Results for “Equivalent”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Technical Equivalency Evaluation of Electrically Cooled Detectors for the In Vivo Measurement of Low Energy Photon Emitters in Human Lungs

LLNL maintains equipment, capability, and operations to measure low energy photon emitting radionuclides potentially deposited inside of workers. Ongoing quality improvement includes the maintenance of detection systems capable of measuring radionuclides o f interest to the LLNL Health and Safety program. This document describes the technical equivalency evaluation of upgraded detectors for LLNL’s routine lung measurement program.

61 RADIATION PROTECTION AND DOSIMETRY↗

The use of atmospheric prediction models to invert infrasound for linear-equivalent time domain moment tensors: Source Physics Experiment, Phase 1

We invert far field infrasound data for the equivalent seismo-acoustic time domain moment tensor to assess the effects of variable atmospheric models as well as to quantify the relative contributions of two presumed source phenomena. The infrasound data was produced by a series of underground chemical explosions that were conducted during the Source Physics Experiment, (SPE) which was originally designed to study explosion-generated seismo-acoustic signal phenomena. The goal of the work presented herein is two-fold: the first goal is to investigate the sensitivity of the estimated time domain moment tensors to variability of the estimated atmospheric model. The second goal is to determine the relative contribution of two possible source mechanisms to the observed infrasonic wave field. Rather than using actual atmospheric observations to estimate the necessary atmospheric Green's functions, we build a series of atmospheric models that rely on publicly available, regional atmospheric observations and the assumption that the acoustic energy results from a linear combination of an underground isotropic explosion and surface spall. The atmospheric observations are summarized and interpolated onto a 3D grid to produce a model of sound speed at the time of the experiment. For each of four SPE acoustic datasets that we invert, we produced a suite of three atmospheric models, based on ten years of regional meteorological observations: an average model, which averages the atmospheric conditions for ten years prior to each SPE event, as well as two extrema models. We find that the inversion yields relatively repeatable results for the estimated spall source. Conversely, the estimated isotropic explosion source is highly variable. This suggests that the majority of the observed acoustic energy is produced by the spall source and/or our modeling of the elastic energy propagation, and it's subsequent conversion to acoustic energy via linear elastic-to-acoustic coupling at the free surface, is too simplistic.

58 GEOSCIENCES↗

Evaluating Equivalent Monte Carlo Calculations

We address several basic issues, primarily whether two sets of MCNP tallies are stochastically equivalent (i.e., that the sets of particle history scores follow the same statistical distribution) and, if di erent, quantify the signi cance level of the di erence. The underlying topics here are of longstanding interest to the statistical community, and no \new" theoretical work needs to be carried out to address them. Related comparisons are useful to code developers in assessing code modi cations and to code users in assessing other simulations and related physical measurements. However, these statistical methods must be applied with care to avoid obtaining misleading results, as we show in several examples. The text is written for MCNP practitioners.

97 MATHEMATICS AND COMPUTING↗

Default Radioactive and Hazardous Waste Management (RHWM) Dose Conversion Factors (DCFs) and Weighting Factors and plutonium-239 equivalent Curie (PE-Ci) methodology for acceptance into the Waste Storage Facilities

DOE-STD-5506-2007 (Ref. 1) is the standard that provides the methodology for preparing hazard analysis and accident analysis for transuranic (TRU) waste facilities. The Waste Storage Facilities hazard and accident analysis for the DSA is developed in accordance with DOE-STD- 5506-2007. Two related issues need to be addressed when implementing DOE-STD-5506-2007 regarding the calculation of consequences from TRU waste releases in accident analysis: Consequences determined in accident analysis must be modeled using inhalation Dose Conversion Factors (DCFs) that are consistent with those from the International Commission on Radiological Protection Publication 72 (ICRP-72, Ref. 2).; The use of a statistical Material at Risk (MAR) representing the distribution of radiological loading of TRU waste containers based on the use of a plutonium-239 equivalent Curie (PE-Ci) methodology. The PE-Ci methodology simplifies accident analysis by allowing one to model releases based on the Curie value of one standard nuclide (e.g., Pu-239) instead of needing to model releases for every potential nuclide of interest. This is accomplished by normalizing the Curie value of all nuclides to a single Curie value of a standard nuclide by using a Weighting Factor that is a ratio of the DCFs associated with the nuclides and that of the standard nuclide. By using the ICRP-72 DCFs to calculate PE-Ci values used in the statistical MAR, the accident analysis that uses that statistical MAR will be consistent with the consequence methodology identified in DOE-STD- 5506-2007.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Steel Equivalency Workbook: An X-Ray Transmission Calculator

The Steel Equivalency Spreadsheet was created as a robust, user-friendly method for the following: 1. Determining if it is possible to image an object. 2. Reducing time needed when selecting equipment and preparing for field imaging activities. 3. Reducing the amount of equipment taken for field imaging activities. 4. Determining a starting point for exposure settings prior to imaging an object. 5. Reducing the amount of dose deposited to complete an imaging operation (in the spirit of As Low As Reasonably Achievable, ALARA). The spreadsheet was developed using various physical models to account for different phenomena. Future implementations aim to expand beyond the Digital Radiography and Computed Tomography Single Munition Scanner (DRCT SMS) in standard configuration to include high energy XRGs (Betatrons) and sub-MeV pulsed XRGs (XRS4). Alternative computational methods that compensate for incoherent scattering when calculating relative transmission are also being pursued. Ultimately the spreadsheet exceeded the developmental goal of having less than 10% average error when comparing calculations to real-world images.

36 MATERIALS SCIENCE↗

Report on the Integration of Experimental and Modeling Data for Initial Equivalence Study of Mechanical Performance in Irradiated LPBF 316 Stainless Steel

To ensure the rapid development, deployment, and use of advanced nuclear technologies, faster qualification approaches are needed. Typically, the primary pathway uses traditional data packages consistent with the American Society of Mechanical Engineers Boiler and Pressure Vessel Code, which does not consider the environmental effects the material will experience such as corrosion and radiation damage. Examining radiation effects requires a significant amount of space in US facilities at the Advanced Test Reactor and the High Flux Isotope Reactor (HFIR) and suffers from natural gradients in temperature and neutron flux profiles. Ion irradiation may enable rapid assessment of radiation-induced damage to a material and is proposed as part of an accelerated materials qualification framework through the Advanced Materials and Manufacturing Technologies program. To enhance the utility of ion irradiation as an examination tool, this report provides the initial assessment of engineering-relevant properties of microstructures produced from ion irradiation in the near-surface volume. Nanoindentation, Vickers hardness, and known tensile properties were brought together with simple mathematical models and experimental data for an initial equivalence study of the mechanical performance of irradiated laser powder bed fusion (LPBF) 316 stainless steels across length scales. Direct observation of the calculated ion irradiation yield stress and measured neutron irradiation yield stress at 2 dpa showed that both datasets exhibit the same trend with irradiation temperature and overlap within an acceptable band of stress values. Ion irradiations at 10 dpa serve as a prediction of properties to compare to postirradiation examination of HFIR-irradiated LPBF 316H further in the program. This work is a significant demonstration of the Licensing Approach with Ions and Neutrons, which uses ion irradiations to generate mechanical property information more rapidly than through neutron irradiations.

36 MATERIALS SCIENCE↗

Equivalent equilibrium ion distributions in ion sources and beams

Ion sources and ion beams often contain ions of more than one charge-to-mass ratio, due to the presence of multiple ionization states and/or multiple atomic and molecular ion species in the source. We show that, under certain conditions, analysis of these systems can be simplified using the notion of “equivalent equilibrium ion distributions” (EEIDs). These distributions have identical ion trajectories, space-charge distributions, and electric-field distributions, but can be composed of ion species with arbitrary charge-to-mass ratios. We use this result to obtain multi-species generalizations for the perveance of an ion diode, which relates the diode voltage to the extracted beam current, and for the perveance of a drifting ion beam, which determines the axial length-scale for beam expansion due to the self-electric field. Applied to a quasi-neutral plasma ion source containing cold ions and hot electrons, we find that the location of the beam-plasma interface (meniscus), where ions are extracted from the plasma, depends on the electron density and ion energy per unit charge at the interface, independent of the ion composition. For certain types of numerical simulations, EEIDs allow one to calculate the beam optics of an intense multi-species ion source by doing a simulation for a single ion species with an artificial charge-to-mass ratio chosen to minimize computation time. We illustrate these results using the 3D particle-in-cell, finite-element code Aleph. The simulations show how ions in a plasma source self-consistently accelerate to the supersonic speed needed for steady, radially expanding flow. Multi-species equilibria are subject to streaming instabilities because, while the different species have the same kinetic energy per unit charge, their velocities scale with the square root of the charge-to-mass ratio. The simulations show that a strong ion streaming instability can occur in a multi-species plasma ion source.

74 ATOMIC AND MOLECULAR PHYSICS↗

The equivalence of inverse Compton scattering and the undulator concept

Inverse Compton scattering is a method to produce very high frequency photon beam. However, the production mechanism can also be viewed as a undulator emission. This is because the electron sees electric and magnetic fields of the incident laser beam and is driven into transverse oscillatory motion in exactly the same way when the electron passes through a undulator consisting of alternating magnetic field. This note gives a detailed examination of the similarity about the two views. Equivalent undulator parameters are derived for the incident laser beam, as well as the differential cross section of photon emission.

43 PARTICLE ACCELERATORS↗

Developing Equivalent Surface Heat Transfer Input Parameters for Updated Standard 140/BESTEST Thermal Fabric Test Cases

ANSI/ASHRAE Standard 140, Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs, is widely cited for evaluating software for use with performance-path energy efficiency analysis in conjunction with well-known energy-efficiency standards, including: ASHRAE Standard 90.1, the International Energy Conservation Code, and other international standards. This paper summarizes recent work to develop improved equivalent surface heat transfer input parameters for the building thermal fabric comparative test cases that comprise a portion of Standard 140. The software-to-software comparative test method allows comparison of simulation results from a wide variety of building energy simulation programs to each other. In this type of test method, it is of great importance to specify inputs that are as well-equivalenced as possible to accommodate a wide variety of input schemes for the tested programs, and thereby reduce the potential for disagreements among them in the tests. Results include new alternative constant surface coefficients that are appropriate to the test cases and demonstrate their ability to approximate the more detailed surface heat transfer models from which they are derived.

BESTEST↗

Validating the C i 5052.17 Å/Mg ii 4481 Å Equivalent Width Ratio as a Diagnostic for F-type Lambda Boo Stars

The Lambda Boo-type stars are chemically peculiar stars with deficiencies of iron-peak elements but near-solar C, N, O, and S abundances. Since the prototype Lambda Boötis was first reported as peculiar, this group has been expanded from a small group of early A-type stars to a larger group of late B to early F-type dwarfs. Although a detailed abundance analysis that supports the Lambda Boo-like abundance pattern is the definitive confirmation of this Lambda Boo characteristic, the rapid rotation of many Lambda Boo stars generally limits how much detail can be derived from an abundance analysis. Traditionally, Lambda Boo candidates have been classified by visually examining the difference between their spectra and spectra of standard stars. Therefore, some ambiguity remains especially for mild or borderline Lambda Boo stars. This is the third paper in a series that establishes a straightforward yet reliable way to identify Lambda Boo-type stars. In previous papers, we identified line equivalent width (EW) ratios in the ultraviolet and visible regions that can distinguish Lambda Boo stars from other metal-weak stars. In this paper, we apply the visible line EW ratio diagnostic to 25 Lambda Boo candidates and carry out a detailed abundance analysis of HD 81290, an F2 star with a C i/Mg ii EW ratio in the range expected for Lambda Boo-type stars. Our elemental abundance analysis results confirm HD 81290's Lambda Boo membership and demonstrate the utility of our EW ratio as a diagnostic for cooler F-type Lambda Boo stars.

79 ASTRONOMY AND ASTROPHYSICS↗

Equivalent Breakeven Installed Cost: A Tradeoff-Informed Measure for Technoeconomic Analysis of Candidate Heliostat Improvements

Technoeconomic analysis (TEA) is commonly used to determine economic viability of power-generating technologies, including concentrating solar power (CSP) and thermal (CST) production plants. Levelized cost of electricity (LCOE) and analogous measures provide an estimate of long-term costs for operating power plants over their designed lifetimes by accounting for revenues and costs in a time-discounted manner. While these measures are effective when assessing a technology’s total lifecycle costs and productivity under various designs, TEA of candidate incremental technology improvements from the lens of LCOE can be limited when required investment and LCOE impacts are small. In this work, we propose a novel metric for TEA of a plant component technology that recasts relative changes in levelized system costs into component-specific capital cost budgets. This measure, which we refer to as the equivalent breakeven installed cost, is the maximum budget for the technology component that leads to improved levelized costs. We illustrate the usefulness of this metric using the example of candidate heliostat improvements for a CSP tower plant. Here, the results suggest that a reduction in mirror washing costs yield a total plant O&M cost of $37/kWe-yr, which is a breakeven proposition if the average reflectance is reduced from 0.90 to 0.85 as a result of the cost savings.

Zolan, Alexander (ORCID:0000000326017604)↗