Search NASA⌕ Search

SEARCH · Search NASA

Results for “FAILURES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Kinetics of Failure in an Elastic Peridynamic Material

The dynamic behavior of an elastic peridynamic material with a nonconvex bond potential is studied. In spite of the material’s inherently unstable nature, initial value problems can be solved using essentially the same techniques as with conventional materials, both analytically and numerically. In a suitably constructed material model, small perturbations grow exponentially over time until the material fails. Additionally, the time for this growth is computed explicitly for a stretching bar that passes from the stable to the unstable phase of the material model. This time to failure represents an incubation time for the nucleation of a crack. The finiteness of the failure time in effect creates a rate dependence in the failure properties of the material. Thus, the unstable nature of the elastic material leads to a rate effect even though it does not contain any terms that explicitly include a strain rate dependence.

36 MATERIALS SCIENCE↗

An integrated computational materials engineering framework to analyze the failure behaviors of carbon fiber reinforced polymer composites for lightweight vehicle applications

A bottom-up multi-scale modeling approach is used to develop an Integrated Computational Materials Engineering (ICME) framework for carbon fiber reinforced polymer (CFRP) composites, which has the potential to reduce development to deployment lead time for structural applications in lightweight vehicles. In this work, we develop and integrate computational models comprising of four size scales to fully describe and characterize three types of CFRP composites. In detail, the properties of the interphase region are determined by an analytical gradient model and molecular dynamics analysis at the nano-scale, which is then incorporated into micro-scale unidirectional (UD) representative volume element (RVE) models to characterize the failure strengths and envelopes of UD CFRP composites. Then, the results are leveraged to propose an elasto-plastic-damage constitutive law for UD composites to study the fiber tows of woven composites as well as the chips of sheet molding compound (SMC) composites. Subsequently, the failure mechanisms and failure strengths of woven and SMC composites are predicted by the meso-scale RVE models. Finally, building upon the models and results from lower scales, we show that a homogenized macro-scale model can capture the mechanical performance of a hat-section-shaped part under four-point bending. Along with the model integration, we will also demonstrate that the computational results are in good agreement with experiments conducted at different scales. The present work illustrates the potential and significance of integrated multi-scale computational modeling tools that can virtually evaluate the performance of CFRP composites and provide design guidance for CFRP composites used in structural applications.

36 MATERIALS SCIENCE↗

Notch insensitivity in fatigue failure of chopped carbon fiber chip-reinforced composites using experimental and computational analysis

This study focuses on the notch effect on the fatigue failure of chopped carbon fiber chip-reinforced sheet molding compound (SMC) composites by using both experimental and numerical methods. The S-N diagrams of notched specimens are first obtained experimentally, which exhibit large scatter and are shown to depend on the spatial distribution of local fiber orientations. After considering the effect of this spatial distribution by adopting a new fatigue damage parameter to normalize the results, we achieve a much better correlation in the normalized S-N diagram for all the notched specimens with different hole diameters. Next, compared with the fatigue results of smooth specimens without notches, we find that SMC composites under tension-tension fatigue loading exhibit notch-insensitivity, which renders this type of composites a better candidate in joints or similar applications. Meanwhile, the fatigue failure mechanisms of notched SMC composites are explored through a microstructure characterization procedure. On this basis, a computational micromechanics model considering the notch effect and an improved multi-scale progressive damage fatigue law, calibrated by coupon-level fatigue tests of smooth SMC composites under different loading conditions, are employed to predict the fatigue behavior of notched SMC composites. We show that detailed failure processes and fatigue life of notched SMC composites can be efficiently and adequately predicted by this computational framework.

36 MATERIALS SCIENCE↗

A macro-micro approach for identifying crystal plasticity parameters for necking and failure in nickel-based alloy haynes 282

Here, this work develops a two-scales macro-micro approach to address the challenge in calibrating crystal plasticity microstructural models when samples undergo necking prior to fracture. The crystal plasticity models are crucial for predicting the materials’ plastic deformation and failure at the microstructure level, identifying the materials’ intrinsic properties as well as investigating the microstructure-properties relationships. However, after necking occurs, the experimentally measured stress-strain curves fail to reflect the materials ‘true’ stress-strain behavior and cannot be directly fitted into crystal plasticity models. The proposed macro-micro approach employs a top-down strategy to address this challenge, which has been studied with experimental tests on precipitation-strengthened Ni-based superalloy Haynes® 282®. In this approach, a macro rate-dependent anisotropic plasticity model with Voce-type hardening and Rice-Tracey damage law is first utilized to model the deformation and failure of the tensile bar, and calibrated by matching the stress-strain curves, necking strain, and reduction of area. Especially, to match the testing results under different applied strain rates, the rate-sensitivity parameter m and saturation stress in the elasticity model are modified to incorporate dependence on the local strain rate. Then, the ‘true’ stress-strain behaviors are extracted from the necking zone of the macro-model, which are used to calibrate a micro-model with explicit microstructures and governed by an extended crystal plasticity law. The consistency between the micro-model and macro-model are enforced during calibration. The calibration outcomes from the crystal plasticity model elucidate the materials intrinsic properties for slip, hardening, and failure, which is vital for further investigations into the microstructure-properties relationship and for accurate prediction of the material behavior under various test and service conditions.

36 MATERIALS SCIENCE↗

TOUGH-RFPA: Coupled thermal-hydraulic-mechanical Rock Failure Process Analysis with application to deep geothermal wells

This paper presents a coupled thermal-hydraulic-mechanical (THM) model for simulating failure processes in geological media. The coupling between stress/strain and heat transfer describing how thermal expansion affects stress is based on the theory of thermo-elasticity. Additionally, the coupling between stress/strain and fluid flow describing how pore-pressure affects stress is governed by Biot's consolidation theory. Stress/strain-dependent porosity/permeability/capillary-pressure defines the influence of stress on fluid flow and thermal fields. The THM model is implemented in the solver module that links the multiphase, multicomponent fluid flow simulator TOUGH2 with the geomechanical simulator RFPA (Rock Failure Process Analysis), which is based on the concept that heterogeneity leads to non-linearity and progressive failure behavior. Capability of TOUGH-RFPA simulator was verified by two benchmark problems related to hydraulic-mechanical and thermal-mechanical response in a hollow cylinder. Then the applicability of TOUGH-RFPA was demonstrated for modeling cooling-induced damage around a very deep geothermal well with mesoscopic heterogeneous properties, which showed complex damage evolution and fracturing during well cooling and fluid pressurization.

42 ENGINEERING↗

Mechanical failure of fresh nuclear grade iron–chromium–aluminum (FeCrAl) cladding under simulated hot zero power reactivity initiated accident conditions

The reactivity initiated accident (RIA) is a postulated accident in light water reactors initiated by a rapid increase in reactivity which causes an increase in fission rate and fuel temperature. One potential mode of fuel system failure during RIA is pellet cladding mechanical interaction (PCMI) due to the rapid thermal expansion of the fuel pellet. Simulated PCMI experiments were performed by rapidly pressurizing iron-chromium-aluminum (FeCrAl) cladding tube samples using a hydraulic modified burst test system, causing the specimens to burst under a biaxial loading path. Deformation and rupture of the specimens were tracked with a telecentric lens and high-speed camera system. Outer surface strains were calculated using digital image correlation (DIC) on speckle patterns painted on the specimens’ outer surfaces. Experiments were conducted at approximately 275 °C, representative of hot zero power RIA conditions. The failure hoop strain was DIC-calculated between approximately 1.8–3.4%, corresponding to quasi-static energy depositions of approximately 110–260 calories per gram UO 2 assuming initial pellet-cladding contact. These conditions are very similar to the proposed energy deposition limit of 150 calories per gram UO 2 for unirradiated zirconium-based cladding in US Nuclear Regulatory Commission (NRC) Draft Regulatory Guide 1327. A very small strain rate dependence was observed in the data, with the magnitude of the failure hoop strain decreasing slightly with increasing strain rate. This observed dependence may be relevant because the FeCrAl cladding strain rate will be approximately 20% higher than in zirconium-based cladding due to the harder neutron spectrum and resultant shorter neutron generation time.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Failure evaluation of neutron-irradiated SiC/SiC composites by underwater acoustic emission

Here, understanding the statistical properties of mechanical properties of non-irradiated and neutron-irradiated SiC/SiC composites is essential for component design. This study aims to evaluate the detailed damage accumulation behavior of composites focusing on two fracture parameters: proportional limit stress (PLS) and acoustic emission (AE) onset stress. The developmental underwater AE technique, which is benefit in non-contact in-situ failure monitoring method during mechanical testing and in handle of the irradiated material, was first applied to evaluate damage accumulation behavior. Two types of chemical vapor infiltration SiC/SiC composites were used: one reinforced with Hi-Nicalon Type-S SiC fiber and one reinforced with Tyranno-SA3 SiC fiber in the form of satin-woven 2D fabrics with pyrolytic carbon interface. Neutron irradiation in the High Flux Isotope Reactor at Oak Ridge National Laboratory reached a fluence of 30 dpa at a temperature of 620–670°C. Four-point flexural tests were conducted to evaluate post-irradiation strength. Weibull statistics did not suggest marked degradation of composite strength. Detailed failure behavior evaluated by AE demonstrated no irradiation-induced change of the AE onset stress (i.e., crack initiation equivalent stress). Failure probability analysis suggests that increasing the reliability of composites (i.e., the Weibull modulus rather than strength itself) is essential to expanding the design margin and benefiting from a probabilistic design approach.

36 MATERIALS SCIENCE↗

Effect of aging on failure mechanism of Alloy 709 at various temperatures

Alloy 709 is a novel austenitic stainless steel with high temperature creep strength, weldability, and corrosion resistance. These properties make the material suitable for applications in the structure of next-generation nuclear power plants. Enduring high temperatures for an extended period of time in the harsh environments of a nuclear power plant results in thermal aging of the material. Therefore, it is imperative to study the effect of thermal aging on the microstructure and mechanical properties of Alloy 709 before its application in the next generation power plants. In this study, hot-processed (forged + rolled), annealed and quenched ingots of Alloy 709 are aged at 650 °C for 2000 h in air and then tested at various temperatures up to 850 °C in an in-situ heating-loading Scanning Electron Microscope (SEM) equipped with Energy Dispersive Spectroscopy (EDS) and Electron Backscatter Diffraction (EBSD). The effect of testing temperature and aging on microstructural evolutions during tensile testing of as-received and aged samples are studied. Furthermore, both as-received and aged samples displayed serrations and drop in ductility at elevated temperatures, due to the effect of dynamic strain aging (DSA). The occurrence of DSA activity was found within temperatures range of 500 °C–750 °C in as-received and 550 °C - 650 °C in aged samples. The aged samples showed less elongation accompanied by shallower dimples on the fractured surface, indicating less ductile failure mechanism compared to as-received samples. Failure mechanism observations on the fracture surface using SEM fractography are correlated to the observations made on the sample surface using in-situ SEM to achieve a complementary set of information to better understand the failure mechanism of this novel alloy.

36 MATERIALS SCIENCE↗

Crystal plasticity modeling and analysis for the transition from intergranular to transgranular failure in nickel-based alloy Inconel 740H at elevated temperature

The precipitation-strengthened Nickel alloy Inconel® 740H® (IN740H) exhibits increased ductility at higher applied strain rates during quasi-static tensile tests at an elevated temperature of 760°C. The examination of fracture surfaces in this context reveals a noteworthy transition of underlying fracture mechanisms from transgranular to intergranular fracture as the applied strain rate decreases from 1×10 -3 / s to 0.83×10 -4 / s . To thoroughly understand the mechanical response of IN740H under these conditions, this study develops a crystal plasticity finite element (CPFE) model. Further, this model incorporates various deformation mechanisms including dislocation slips, climb, and grain boundary sliding, which are relevant to the test conditions. The model is calibrated using data from both tensile tests at different strain rates and creep tests across a broad stress range at 760°C, enabling the accurate determination of model parameters for each mechanism. Simulation results well captured the experimental observations of different failure modes. At higher strain rates, the model shows a dominance of dislocation slip leading to heterogeneous plastic deformation and formation of transgranular shear bands causing the failure, while at lower strain rates, an increased activity of grain boundary sliding causes grain boundaries crack leading to intergranular failure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Failure investigation of nuclear grade POCO graphite target in high energy neutrino physics through numerical simulation

In many high energy physics neutrino beamlines, targets are made up of isotropic POCO graphite grade for production of neutrinos for high energy particle physics research and are bombarded with highly energetic pulsed proton beam. The pulsed proton beam with a small beam size creates thermal stress waves as well as radiation damage such as displacement damage, void formation, swelling, and gas formation amongst others. As a result, after a few years of operation one of the longest operated targets appears to have undergone bulk swelling and fractured along the beam centerline. A complex interaction of dynamic loading due to beam, material degradation due to irradiation are thought to have caused such a failure. Here, we present a numerical simulation to capture the combined effects of swelling and the dynamic effect of thermal stress waves due to beam heating, to explain the failure of target. An empirical formula has been developed to take into account swelling as a function of temperature and proton fluence and has been implemented in a commercial finite element code. Extensive X-ray diffraction (XRD) were performed on graphite samples from the failed target to understand the lattice parameter changes due to irradiation and build a valid empirical model. Simulation results show that swelling plays a major role in elevating the stress state in the material exceeding the failure strength while the pulsed beam heating also introduces fatigue loading that would explain brittle fracture emanating from inside of the material and propagating outward. Such empirical formulations will help in identifying the threshold values of critical parameters to extend the service life of future multi-megawatt neutrino targets and targets in other accelerator environments.

43 PARTICLE ACCELERATORS↗

Material Failure Mechanisms of Alkaline Zn Rechargeable Conversion Electrodes

Zinc (Zn) alkaline electrodes hold great importance and promise in the battery technology community, yet their behavior in real-world applications is still poorly understood. Here, we report a study of failure mechanisms and material evolution during cycling of 27 zinc–manganese dioxide (Zn–MnO 2 ) cells wherein the percent utilization of the Zn electroactive material is systematically varied between 1 and 16%. Cell fabrication is kept typical of the prevailing industrial cell design. The cycle life ranges from 2800 to 60, depending inversely on the Zn utilization. In all cases, the Zn material microstructure sheds the polytetrafluoroethylene (PTFE) binder and forms zinc oxide (ZnO) rods, with longer rods formed by lower current per Zn mass. Irreversible side reactions such as the hydrogen evolution reaction (HER), short circuits, or gas crossover cause the Zn anode’s charging efficiency to average 92% (as low as 86%), which in turn causes the baseload of metallic Zn to gradually disappear. Cell failure occurs after the baseload of metallic Zn is exhausted. The total lifetime discharge capacity remains constant near 12 ± 5 Ah/g Zn invariant of Zn utilization, which suggests that the aforementioned processes of Zn microstructural evolution and side-reaction destruction of baseload metallic zinc both progress linearly with cell capacity throughput. Manual reproduction of individual Zn failure mechanisms is performed in 22 fresh cells. Tight packing of the microstructure can lead to poor mass transfer, which causes supersaturation of soluble Zn and finally produces a high overvoltage during discharge. Here, the low charging current density yields poor coulombic efficiency due either to the competitive HER or soft short circuits.

25 ENERGY STORAGE↗

Hydromechanical Modeling of Fault Rupture in Geologic CO 2 Sequestration: A Comparison of Two Failure Criteria

Abstract The large‐scale implementation of geological carbon sequestration has raised concerns about potential fault activation and induced seismicity, which could compromise storage integrity and pose seismic risks. We theoretically compared two failure criteria, Mohr‐Coulomb (MC) and Modified Cam‐Clay criteria (MCC), to assess fault rupture during CO 2 storage. Both criteria characterize fault behavior in a specific stress regime but differ in reducing the complexity of fault rupture to a few key mechanisms. Using a coupled hydromechanical model, we demonstrate that the choice of a failure criterion and the physics of fault weakening associated with these criteria strongly condition fault response to a given fluid injection. MC mainly relates rupture to friction, while MCC relates rupture to fault poro‐plasticity. Our findings highlight that the selection of a failure criterion, being inherently subjective, can significantly alter the predicted fault behavior during CO 2 storage, thereby impacting the reliability of geomechanical risk assessments.

Cao, M. [Energy Geosciences Division Lawrence Berk↗

Failure modes of protection layers produced by atomic layer deposition of amorphous TiO 2 on GaAs anodes

Amorphous titanium dioxide (a-TiO 2 ) films formed by atomic layer deposition can serve as protective coatings for semiconducting photoanodes in water-splitting cells using strongly alkaline aqueous electrolytes. Herein, we experimentally examine the mechanisms of failure for p + -GaAs anodes coated with a-TiO 2 films (GaAs/a-TiO 2 ). Galvanic displacement of exposed GaAs by Au allowed imaging of pinholes in the a-TiO 2 coatings, and enabled collection of quantitative and statistical data associated with pinhole defects. A combination of imaging, electrochemical measurements, and quantitative analyses of corrosion products indicated that extrinsic pinholes were present in the a-TiO 2 films before electrochemical operation. During electrochemical operation these pinholes led to pitting corrosion of the underlying GaAs substrate. The dominant source of pinholes was the presence of atmospheric particulate matter on the GaAs surface during deposition of the a-TiO 2 layer. The pinhole density decreased substantially when the thickness of the a-TiO 2 coating increased beyond 45 nm, and approached zero when the thickness of the film exceeded 112 nm. The density of pinholes in films thinner than 45 nm decreased when the a-TiO 2 coating was deposited in an environmentally controlled cleanroom. Pinhole-free GaAs/a-TiO 2 devices were also tested via chronoamperometry to quantify the rate of pinhole formation during electrochemistry. The time-to-failure increased with thickness, suggesting that the failure mechanism may involve diffusion or migration through the film. However, other mechanisms may also contribute to the degradation of thicker films (>112 nm). Nevertheless, as previously hypothesized, extrinsic pinhole defects formed during deposition and testing control the short-term protective performance of the a-TiO 2 film for GaAs anodes evolving O 2 from water.

25 ENERGY STORAGE↗

Identification of Important Phenomena for Light Water Reactors During Heat Transport System Failure Events in Integrated Energy Systems

This work adapts historical literature and existing phenomena identification and ranking tables (PIRT) to be applicable to a novel nuclear power plant (NPP) and chemical or thermal process integrated energy system (IES), particularly focusing on the process heat and heat transport system failure events that are not a concern during normal NPP operation but become vital when an IES is considered. Nuclear energy has been suggested to go beyond base-load applications and be used for hydrogen co-generation systems, amongst other IESs. Prior to the implementation of nuclear IESs, sufficient analysis must be performed on accident events to ensure public safety. The events considered were deemed important because of their potential to damage systems, structures, and components (SSCs). Process thermal events of concern include loss of heat load and temperature transient events. Loss of heat load events were characterized as having high importance and being well understood. Temperature transient events may be further categorized by the cyclic loading and harmonics phenomena. Cyclic loading issues were classified as medium to high importance with knowledge gaps existing regarding fatigue and low power operation, while harmonics phenomena were classified as low importance and are well understood. Heat transport system failure events of concern include intermediate and process heat exchanger failures, mass addition to reactor coolant, ingress of material from thermal manifold/energy storage, and loss of intermediate fluid. Furthermore, these events tended to be of high or medium importance, with some knowledge gaps needing to be filled for individual reactor systems due to unique designs.

Integrated Energy System (IES)↗

Failure Analysis of a New Polyamide-Based Fluoropolymer-Free Backsheet After Combined-Accelerated Stress Testing

The viability of novel coextruded, fluoropolymer-free backsheets for photovoltaic (PV) modules has been questioned as a result of a large number of early-life backsheet failures in PV installations containing one of the earliest co-extruded polyamide (PA)-based backsheet to reach the market, “AAA.” New PV reliability testing protocols have been recently developed and applied to backsheets to reproduce failures observed in the field and evaluate the durability of novel backsheet materials and designs prior to commercialization. A new co-extruded PA-based backsheet was tested using combined-accelerated stress testing (C-AST) and demonstrated a greater lifetime than AAA, and some other fluoropolymer-based backsheets such as polyvinylidene fluoride. The improved PA-based backsheet also eventually failed by through-thickness cracking. Using surface and bulk material characterization techniques, we performed a comprehensive study of material properties before and after the stress testing. Aging of the backsheet resulted in an increase of surface roughness by erosion of the outer PA layer. However the failure is more likely related to an increase in crystallinity of the polyolefin core layer reducing the backsheet tearing energy. The analysis can ultimately inform on the specific weaknesses of the materials so that the manufacturer can improve the backsheet design to extend its lifetime.

14 SOLAR ENERGY↗

Failure Mode and Effects Analysis (FMEA) for Photovoltaic Inverter

Photovoltaic (PV) inverters are critical yet vulnerable components in modern energy systems, often acting as reliability bottlenecks that increase the levelized cost of energy (LCOE). To address this, this paper presents a comprehensive Failure Mode and Effects Analysis (FMEA) tailored for PV inverters. Leveraging field data and literature, we identify failure-prone components, such as capacitors,, and relays, and prioritize their risks based on quantitative Risk Priority Numbers (RPNs). The analysis reveals that surge-induced MOV short circuits, capacitor degradation, and environmental cooling fan failures dominate the risk profile. These findings provide a targeted framework for reliability improvement, guiding future efforts in predictive diagnostics, design optimization, and accelerated life testing strategies.

14 SOLAR ENERGY↗

Correlation of Advanced Accelerated Stress Testing with Polyamide-Based Photovoltaic Backsheet Field-Failures

Cracking of polyamide (PA)-based photovoltaic (PV) backsheet materials has been widely reported for field-aged modules. Failure was not detected by conventional accelerated stress tests (ASTs), which lacked the necessary combination of stress factors and/or factor sequences. PA-based AAA backsheet cracking has since been reproduced through combined and sequential stress testing. Planar- and cross-sectional-optical microscopy as well as Fourier-transform Infrared Spectroscopy (FTIR), have been used to elucidate the mechanical and chemical changes which lead to failure of the backsheet. Field-aged backsheet samples demonstrating failure in various climates (including locations in China and Italy) are also analyzed. Through the analysis, a comparison is made between the different stress testing protocols and the field-aged samples to validate relevance of the advanced stress tests. It is shown that the changes induced through combined-accelerated stress testing (C-AST) were most representative of changes induced by the field, supporting the relevance of C-AST and providing validity for the test protocol.

14 SOLAR ENERGY↗

Reliability Analysis of Power Grids Considering Component Failures of Variable Energy Resources

This paper proposes an improved model for the reliability assessment of power systems considering component failures of variable energy resources (VER). The inherent intermittency of VER such as solar photovoltaic (PV) and wind farms, along with their susceptibility to component failures, present significant challenges to reliable system operation. These issues, combined with power grid operation and network constraints, complicate the reliable operation of VER-integrated power systems. Here, to address these concerns, this paper introduces a reliability assessment framework that considers VER input variability, its impact on component availability, and their resulting impact on overall system reliability. Stochastic models based on discrete Markov processes are developed to incorporate variable irradiance, wind speeds, and their effects on PV and wind component failure rates. A next-event and state transition-based approach is then developed to integrate the stochastic models into a mixed-timing sequential Monte Carlo simulation framework for composite reliability assessment. Case studies on the RTS-GMLC system demonstrate the effectiveness of the proposed model in evaluating the reliability of VER-integrated systems.

Pandit, Dilip [Sandia National Laboratories (SNL-N↗