At least 631 records · Page 35

Planar Rotary Motor Using Ultrasonic Horns

One of the first piezoelectric motor designs with significant rotational speeds was outlined by Barth. This device used extensional piezoelectric elements to produce a time varying force at a distance r from the center of a centrally supported disk. These extensional actuators produced micro-steps at a high frequency with the end result being macroscopic rotation of the disk and high torque. The rotation direction is controlled by the choice of the actuators and the direction of the extension about the rotor center. A recent advancement in producing pre-stressed power ultrasonic horns using flexures allows for the development of high torque ultrasonic motors based on the Barth's idea that can be fabricated in a 2D plate or in more complicated 3D structures. In addition to the pre-stress flexures the design also allows for the use of flexures to produce the rotor/horn normal force. The torque can be controlled by the number of actuators in the plane and the amplitude of the normal force. This paper will present analytical and experimental results obtained from testing prototype planar motors.

ultrasonic impacts.↗

Threshold angle and valid fracture of the sectored flexural specimen

Here, the sectored flexural specimen was developed over a decade ago to measure the strength of ceramic and glass tubes and cylinders in which flaws on a tube's or cylinder's outer surface are limiters of axial tensile failure stress. Using the specimen's geometry, the associated axial tensile failure stress can be analytically calculated from the failure force measured from simple uniaxial bending, and multiple specimens (and test data) can be harvested from a single tube or cylinder. The sector angles of specimens in previous studies were somewhat arbitrarily chosen and usually produced validly occurring fractures and data; however, if the angle used was too small (relative to the tube's or cylinder's geometry), then undesirable application–irrelevant edge–located failures resulted. To avoid such failures in specimen design, a threshold sector angle was identified to guide the selection of a minimum sector angle (and consequential cross section) for any arbitrary sector flexural specimen harvested from a tube or cylinder. If the sector angle of the specimen is larger than the threshold value, then fracture will not occur at a specimen's edge and the measured axial failure stress will be limited by surface–located flaws on the tube's or cylinder's outer surface.

36 MATERIALS SCIENCE↗

Polymer composites based on gypsum matrix

The role of polymers as retarder additives is to prolong the workability connected with setting time of gypsum. Various cellulose derivatives, soluble in water in concentration up to 1,5% by weight were applied taking different water/binder ratio. The hydration process of calcium sulfate hemihydrate (gypsum binder) into dihydrate (gypsum plaster) was observed by setting and calorimetric techniques. Scanning electron microscopy confirmed that the gypsum microstructure was varied when polymers are used. The mechanical properties of gypsum plasters were studied by bending strength test and they are correlated with sample microstructure.

36 MATERIALS SCIENCE↗

Bending testing and characterization of surrogate nuclear fuel rods made of Zircaloy-4 cladding and aluminum oxide pellets

We studied behavior of surrogate nuclear fuel rods made of Zircaloy-4 (Zry-4) cladding with alumina pellets under reversed cyclic bending. Tests were performed under load or moment control at 5 Hz, and an empirical correlation was established between rod fatigue life and amplitude of the applied moment. Fatigue response of Zry-4 cladding was further characterized by using flexural rigidity. Degradation of flexural rigidity was shown to depend on the moment applied and the prefatigue condition of specimens. Pellet-to-pellet interface (PPI), pellet-to-cladding interface (PCI), and pellet condition all affect surrogate rod failure. Bonding/debonding of PPI/PCI and pellet fracturing contribute to surrogate rod bending fatigue. Also, the effect of sensor spacing on curvature measurement using three-point deflections was studied; the method based on effective specimen gauge length is effective in sensor spacing correction. Finally, we developed the database and gained understanding in this study such that it will serve as input to analysis of SNF vibration integrity.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SU-G-TeP3-07: On the Development of Mechano-Biological Assessment of Leukemia Cells Using Optical Tweezers

Purpose: Patients with BCR-ABL (Ph +ve) acute lymphoblastic leukemia are at very high risk of relapse and mortality. In line with the NIH mission to understand the physical and biological processes, we seek to report mechano-biological method to assessment and distinguish treated/untreated leukemia cells. Methods: BCR-ABL leukemia cell populations and silica microspheres were trapped in a 100x magnification optical trapping system (λ=660 nm, 70 mW). Light refracted through the trapped sample was collected in the back focal plane by a quadrant detector to measure the positions of individual cells. The sample was driven at a known frequency and amplitude with a flexure translation stage, and the target’s response was recorded. The measured response was calibrated using the known driving parameters, and information about cell movements due to mechano-biological effects was extracted. Two leukemia cell populations were tested: a control group and a group treated with 2 Gy. Results: The mechano-biological movements of 10 microspheres, control cells, and treated cells were tracked over a ∼30 minute window at 1 minute intervals. The microsphere population did not see significant change in mechano-biological movements over the testing interval and remained constant. The control cell population saw a two-fold rise in activity that peaked around 1200 seconds, then dropped off sharply. The treated cell population saw a two-fold rise in activity that peaked at 400 seconds, and dropped off slowly. Conclusion: The investigated technique allows for direct measurement the movements of a trapped object due to mechano-biological effects such as thermal and extracellular motion. When testing microspheres, the mechano-biological activity remained constant over time due to the lack of biological factors. In both the control and treated cell populations, the mechano-biological activity was increased, possibly due to mitochondrial activation. This extra activity decreased over time, possibly due to cellular damage from trapping radiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of thermal and environmental exposure on the mechanical properties of graphite/polyimide composites

Composites were exposed in circulating and static air environments up to 589 K for a maximum of 1000 hours. Composites of HT-S, HM-S, Thornel 50S, and Fortafil 5-Y fiber and a new addition type polyimide resin were laminated in a matched-die mold. Flexural strengths, flexural modulus, and interlaminar shear strengths were determined at 297, 533, and 598 K after various durations of exposure. Composite and fiber weight loss characteristics were determined by isothermal gravimetric analysis in air. Properties of composites exposed and tested at the environment temperatures were compared with those determined under short-term exposure. A new short beam interlaminar shear fixture is described. Environmental effects of long-term ambient temperature exposure on the elevated temperature mechanical properties of graphite/polyimide composites are presented.

Hanson, M. P.↗

Effects of thermal and environmental exposure on the mechanical properties of graphite/polyimide composites.

Composites were exposed in circulating and static air environments up to 600 F for a maximum of 1000 hours. Composites of HT-S, HM-S, Thornel 50S, and Fortafil 5-Y fiber and a new addition type polyimide resin were laminated in a matched-die mold. Flexural strength, flexural modulus, and interlaminar shear strengths were determined at 75, 500 and 600 F after various durations of exposure. Composite and fiber weight loss characteristics were determined by isothermal gravimetric analysis in air. Properties of composites exposed and tested at the environment temperatures are compared with those determined under short-term exposure. A new short beam interlaminar shear fixture is described. Environmental effects of long-term (up to one year) ambient temperature exposure on the elevated temperature mechanical properties of graphite/polyimide composites are presented.

Hanson, M. P.↗

A Low Power Cryogenic Shutter Mechanism for Use in Infrared Imagers

This paper discusses the requirements, design, operation, and testing of the shutter mechanism for the Infrared Array Camera (IRAC). The shutter moves a mirror panel into or out of the incoming light path transitioning IRAC between data acquisition and calibration modes. The mechanism features a torsion flexure suspension system, two low-power rotary actuators, a balanced shaft, and a variable reluctance position sensor. Each of these items is discussed along with problems encountered during development and the implemented solutions.

Schwinger, D. Scott↗

A Low Power Cryogenic Shutter Mechanism for use in Infrared Images

This paper discusses the requirements, design, operation, and testing of the shutter mechanism for the Infrared Array Camera (IRAC). The shutter moves a mirror panel into or out of the incoming light path transitioning IRAC between data acquisition and calibration modes. The mechanism features a torsion flexure suspension system, two low-power rotary actuators, a balanced shaft, and a variable reluctance position sensor. Each of these items is discussed along with problems encountered during development and the implemented solutions.

Schwinger, D. Scott↗

Assessment of impact damage of composite rocket motor cases

This contract reviewed the available literature on mechanisms of low velocity impact damage in filament wound rocket motor cases, MDE methods to quantify damage, critical coupon level test methods, manufacturing and material process variables and empirical and analytical modeling off impact damage. The critical design properties for rocket motor cases are biaxial hoop and axial tensile strength. Low velocity impact damage is insidious because it can create serious nonvisible damage at very low impact velocities. In thick rocket motor cases the prevalent low velocity impact damage is fiber fracture and matrix cracking adjacent to the front face. In contrast, low velocity loading of thin wall cylinders induces flexure, depending on span length and the flexure induces delamination and tensile cracking on the back face wall opposed to impact occurs due to flexural stresses imposed by impact loading. Important NDE methods for rocket motor cases are non-contacting methods that allow inspection from one side. Among these are vibrothermography, and pulse-echo methods based on acoustic-ultrasonic methods. High resolution techniques such as x-ray computed tomography appear to have merit for accurate geometrical characterization of local damage to support development of analytical models of micromechanics. The challenge of coupon level testing is to reproduce the biaxial stress state that the full scale article experiences, and to determine how to scale the composite structure to model full sized behavior. Biaxial tensile testing has been performed by uniaxially tensile loading internally pressurized cylinders. This is experimentally difficult due to gripping problems and pressure containment. Much prior work focused on uniaxial tensile testing of model filament wound cylinders. Interpretation of the results of some studies is complicated by the fact that the fabrication process did not duplicate full scale manufacturing. It is difficult to scale results from testing subscale cylinders since there are significant differences in out time of the resins relative to full scale cylinder fabrication, differences in hoop fiber tensioning and unsatisfactory coupon configurations. It appears that development of a new test method for subscale cylinders is merited. Damage tolerance may be improved by material optimization that uses fiber treatments and matrix modifications to control the fiber matrix interface bonding. It is difficult to develop process optimization in subscale cylinders without also modeling the longer out times resins experience in full scale testing. A major breakthrough in characterizing the effect of impact damage on residual strength, and understanding how to scale results of subscale evaluations, will be a sound micromechanical model that described progressive failure of the composite. Such models will utilize a three dimensional stress analysis due to the complex nature of low velocity impact stresses in thick composites. When these models are coupled with non-contact NDE methods that geometrically characterize the damage and acoustic methods that characterize the effective local elastic properties, accurate assessment of residual strength from impact damage may be possible. Directions for further development are suggested.

Paris, Henry G.↗

Study on shear strengthening of RC continuous T-beams using different layers of CFRP strips

Carbon fiber reinforced polymer (CFRP) laminates are externally bonded to reinforced concrete (RC) members to provide additional strength such as flexural, shear, etc. However, this paper presents the results of an experimental investigation for enhancing the shear capacity of reinforced concrete (RC) continuous T- beams using different layers of CFRP wrapping schemes. A total of three concrete beams were tested and various sheet configurations and layouts were studied to determine their effects on ultimate shear strength and shear capacity of the beams. One beam was kept as control beams, while other beams were strengthened with externally bonded CFRP strips with three side bonding and one or two layers of CFRP strips. From the test results, it was found that all schemes were found to be effective in enhancing the shear strength of RC beams. It was observed that the strength increases with the number of sheet layers provided the most effective strengthening for RC continuous T- beam. Beam strengthened using this scheme showed 23.21% increase in shear capacity as compared to the control beam. Two prediction models available in literature were used for computing the contribution of CFRP strips and compared with the experimental results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Compression behavior of unidirectional fibrous composite

The longitudinal compression behavior of unidirectional fiber composites is investigated using a modified Celanese test method with thick and thin test specimens. The test data obtained are interpreted using the stress/strain curves from back-to-back strain gages, examination of fracture surfaces by scanning electron microscope, and predictive equations for distinct failure modes including fiber compression failure, Euler buckling, delamination, and flexure. The results show that the longitudinal compression fracture is induced by a combination of delamination, flexure, and fiber tier breaks. No distinct fracture surface characteristics can be associated with unique failure modes. An equation is described which can be used to extract the longitudinal compression strength knowing the longitudinal tensile and flexural strengths of the same composite system.

Sinclair, J. H.↗

Piezoelectrically Actuated Shutter for High Vacuum

A piezoelectrically actuated shutter is undergoing development for use in experiments on laser cooling of atoms. The shutter is required to be compatible with ultrahigh vacuum [pressure of 10(exp -9) torr (.1.3 x 10(exp -7) Pa) or less] and to be capable of performing reliably in the vacuum for at least one year. In operation, the shutter would enable the collection and launch of successive samples of cold atoms and would enable the interrogation of the immediately preceding sample while preventing disturbance of the atoms of that sample by light from the collection region. A major constraint is imposed on the design and operation of the shutter by a requirement that it not generate a magnetic field large enough to perturb an atomic clock. An electromagnetically actuated shutter could satisfy all requirements except this one. Hence, it was decided to use piezoelectric instead of electromagnetic actuation. The shutter (see figure) includes two commercial piezoelectrically driven flexure stages that produce a travel of 0.5 mm. Levers mechanically amplify the travel to the required level of 1 cm. Problems that remained to be addressed at the time of reporting the information for this article included lifetime testing and correction of a tendency for shutter blades to bounce open.

Thompson, Robert↗

POTENTIAL IMPACT OF INTERFACIAL BONDING EFFICIENCY ON USED NUCLEAR FUEL VIBRATION INTEGRITY DURING NORMAL TRANSPORTATION

Finite element analysis (FEA) was used to investigate the impacts of interfacial bonding efficiency at pellet pellet and pellet clad interfaces on surrogate of used nuclear fuel (UNF) vibration integrity. The FEA simulation results were also validated and benchmarked with reversible bending fatigue test results on surrogate rods consisting of stainless steel (SS) tubes with alumina-pellet inserts. Bending moments (M) are applied to the FEA models to evaluate the system responses of the surrogate rods. From the induced curvature, , the flexural rigidity EI can be estimated as EI=M/ . The impacts of interfacial bonding efficiency include the moment carrying capacity distribution between pellets and clad and cohesion influence on the flexural rigidity of the surrogate rod system. The result also indicates that the immediate consequences of interfacial de-bonding are a load carrying capacity shift from the fuel pellets to the clad and a reduction of the composite rod flexural rigidity. Therefore, the flexural rigidity of the surrogate rod and the bending moment bearing capacity between the clad and fuel pellets are strongly dependent on the efficiency of interfacial bonding at the pellet pellet and pellet clad interfaces. FEA models will be further used to study UNF vibration integrity.

finite element method↗

Sister Rod Destructive Examinations (FY23): Appendix H: Instron Uncertainty Calculations

This document discusses the uncertainty of measurements associated with the Instron system and the resulting uncertainty in the acquired measurements and calculated information. The primary parameters measured during the Instron test include the applied load and specimen deflection. The associated primary calculated parameters are the maximum beam deflection at the rod’s axial center and modulus of elasticity. Secondary calculated parameters include specimen stress and strain amplitudes, as well as flexural rigidity. The uncertainty associated with the primary and secondary calculated parameters was investigated based on the known uncertainty in the measured parameters.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Compressive behavior of unidirectional fibrous composites

The longitudinal compressive behavior of unidirectional fiber composites was investigated by using the Illinois Institute of Technology Research Institute (IITRI) test method with thick and thin test specimens. The test data obtained are interpreted by means of stress/strain curves from back-to-back strain gages, examination of fracture surfaces by scanning electron microscope, and predictive equations for distinct failure modes including fiber compression failure. Euler buckling, delamination, and flexure. The results show that longitudinal compressive fracture is induced by a combination of delamination, flexure, and fiber tier breaks. No distinct fracture surface characteristics can be associated with unique failure modes. An equation is described that can be used to extract the longitudinal compressive strength from the longitudinal tensile and flexural strengths of the same composite system.

Sinclair, J. H.↗

Design, Fabrication and Testing of 30-cm Dia. Dished Carbon-Carbon Ion Engine Grids

Two sets of 30-cm dia. dished carbon-carbon ion engine grid sets were fabricated, assembled and tested. The carbon-carbon grid blanks were fabricated from unidirectional prepreg tape, having a very high fiber volume fraction of 57 percent and resulting in the strongest quasi-isotropic carbon-carbon material known to the authors. The flexural modulus of the panel material was measured at 275 MPa, corresponding to 80 percent of the value of molybdenum.

ion↗

Using Finite Model Analysis and Out of Hot Cell Surrogate Rod Testing to Analyze High Burnup Used Nuclear Fuel Mechanical Properties

Based on a series of FEA simulations, the discussions and the conclusions concerning the impact of the interface bonding efficiency to SNF vibration integrity are provided in this report; this includes the moment carrying capacity distribution between pellets and clad, and the impact of cohesion bonding on the flexural rigidity of the surrogate rod system. As progressive de-bonding occurs at the pellet-pellet interfaces and at the pellet-clad interface, the load ratio of the bending moment carrying capacity gradually shifts from the pellets to the clad; the clad starts to carry a significant portion of the bending moment resistance until reaching the full de-bonding state at the pellet-pellet interface regions. This results in localized plastic deformation of the clad at the pellet-pellet-clad interface region; the associated plastic deformations of SS clad leads to a significant degradation in the stiffness of the surrogate rod. For instance, the flexural rigidity was reduced by 39% from the perfect bond state to the de-bonded state at the pellet-pellet interfaces.

fuel-pellet interface↗