Search NASA⌕ Search

SEARCH · Search NASA

Results for “GAMMA RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Development of In-Situation Radioactivity Inspection System for Food Materials

The impacts on the ocean of releases of radionuclides from the Fukushima nuclear power plants remain unclear. Korean people worry about radioactive contamination of Japanese and Korean sea products. Radioactive contamination of processed foodstuffs, livestock, sea products, farm products imported from Japan and fishes caught in coastal oceans of Korea has become an important social issue. Recently, there are also needs of inspection system for monitoring of public meals such like school feedings of kindergarten, elementary/middle/high school and university. Radioactivity inspections of food materials have been executed manually with portable measuring instruments or at labs using their samples. But, it's very important the radioactivity inspection should be performed at the field of feeding facilities. To protect the health of people from radioactivity contained in Japanese marine products imported to Korea, a system to inspect radioactivity in real time has been developed. The system is to measure the radioactivity level of farm and marine products and public meals continuously and automatically at inspection sites of an agency checking radiation of imported foodstuffs or school. The performance test of NaI(Tl) detector was examined using the quantified Cs-137 source 10 Bq/kg, 30 Bq/kg, 50 Bq/kg, 300 Bq/kg and 900 Bq/kg at Korea Research Institute of Standards and Science(KRISS). Source was put in a box and radioactivity was measured in the middle of the box. First of all, Background was measured and calibration was performed using the Cs-137 300 Bq and Ba-133 3700 Bq for 60 minutes. After setting the background and calibration data, tests of the Cs-137 10, 30, 50, 300, 900 Bq/kg were executed for 10 minutes. A peak-shaped graph is shown at the location of 662 KeV (80∼100 channel). This is due to the gamma radiation energy with 662 KeV emitted by the Cs-137. Because through KRISS examination, the MDA (minimum detectable activity) is about 23 Bq/kg, it is reasonable Cs-137 10 Bq/kg cannot be measured. And in cases of Cs-137 300 Bq/kg and 900 Bq/kg, there are some peak movement on the graph. It can be adjusted by controlling gain or high voltage. The examination was identified through the performance test (Cs-137 10, 30, 50, 300, 900 Bq/kg) at KRISS. In order to increase the measurement efficiency of Cs-137 and the system performance, database will be built up based on radioactivity measurement results from 10 to 300 Bq/kg with the unit 10. Thus, Cs-137 concentration of food materials can be identified below the maximum permissible concentration of 100 Bq/kg on a basis of the spectrum characteristic of Cs-137. Also, anxiety about radioactive contamination of foods after the Fukushima nuclear accident will be eased and trust of the radioactive inspection is expected definitely. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Growth and properties of Lithium Salicylate single crystals

An attractive feature of {sup 6}Li containing fluorescence materials that determines their potential application in radiation detection is the capture reaction with slow ({approx}< 100 keV) neutrons: {sup 6}Li + n = {sup 4}He + {sup 3}H + 4.8MeV. The use of {sup 6}Li-salicylate (LiSal, LiC{sub 6}H{sub 5}O{sub 3}) for thermal neutron detection was previously studied in liquid and polycrystalline scintillators. The studies showed that both liquid and polycrystalline LiSal scintillators could be utilized in pulse shape discrimination (PSD) techniques that enable separation of neutrons from the background gamma radiation. However, it was found that the efficiency of neutron detection using LiSal in liquid solutions was severely limited by its low solubility in commonly used organic solvents like, for example, toluene or xylene. Better results were obtained with neutron detectors containing the compound in its crystalline form, such as pressed pellets, or microscopic-scale (7-14 micron) crystals dispersed in various media. The expectation drown from these studies was that further improvement of pulse height, PSD, and efficiency characteristics could be reached with larger and more transparent LiSal crystals, growth of which has not been reported so far. In this paper, we present the first results on growth and characterization of relatively large, a cm-scale size, single crystals of LiSal with good optical quality. The crystals were grown both from aqueous and anhydrous (methanol) media, mainly for neutron detection studies. However, the results on growth and structural characterization may be interesting for other fields where LiSal, together with other alkali metal salicylates, is used for biological, medical, and chemical (as catalyst) applications.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

CHARACTERIZATION OF SECONDARY PHASES AND OTHER DEFECTS IN CDZNTE

Semiconducting CdZnTe or 'CZT' crystals are very suitable for use as a room temperature-based gamma radiation spectrometer. During the last decade, modifications in growth methods for CZT have significantly improved the quality of the produced crystals however there are material features that can influence the performance of these materials as radiation detectors. For example, various structural heterogeneities within the CZT crystals, such as, pipes, voids, polycrystallinity, and secondary phases (SP) can have a negative impact on the detector performance. In this study, a CZT material was grown by the modified vertical Bridgman growth (MVB) method with zone leveled growth in the absence of excess Te in the melt. Numerous SP were imaged using transmission IR at a volume % of 0.002. Samples from this material were analyzed using various analytical techniques to evaluate its electrical properties, purity and detector performance as radiation spectrometers and to determine the morphology, dimension and elemental /structural composition of one of the SP in this material. This material was found to have a high resistivity and good radiation spectrometer performance. It had SPs that were rich in calcium (Ca), carbon (C) and oxygen (O) (possibly CaCO{sub 3}) or only C and O that were 5 {micro}m or less in diameter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of Plastic Scintillator Properties for Radioactive Sources Dosimetry - Paper 108

Plastic scintillator is a simple material which has the density close to that of human soft tissue (1.06 g/cm{sup 3}). Its energy response is close to that of human soft tissue and it is relatively energy independent. This prospect provide a desired characteristics in measuring dose by plastic scintillator either for radiation monitoring or personal dosimeter. Generally the energy calibration of organic scintillator will be done by using gamma ray sources. The positions of Compton edge in pulse height spectra, which have known energy values will be identified. However the Compton edge normally is very broad and difficult to determine the point corresponding to that particular Compton electron energies. Many researchers used several fitting functions and Monte Carlo simulations to determine the position of Compton edge. For example, Proctor and Wellman (2012) used a straight line fit to the linear part of Compton edge and extrapolated to zero count. While L. Swiderski et al. used a method based on a back-scattered coincidence measurement to measure in a wide energy range the position of Compton edge in organic scintillators. For a simple and quick approach of calibration, we used a Gauss-error function to fit the Compton edge region of interest by assumed that the location of maximum energy of Compton electrons is half-height of the Compton maximum (CM). The reasons is because the CM position could be determined easily from the spectra throughout wide energy range. Interpreting gamma dose rates from accumulated plastic scintillation detector spectra is often a complex task because the probability of a full energy deposition event in the detector is often negligible. Despite no full energy peaks in plastic scintillator spectra, several attempts have been made by the other researchers to obtain the dose from the energy distribution spectra of gamma radiation. For example, Proctor and Wellman used the modified spectrum dose index (SDI) to calculate the exposure rates by multiplying the energy corresponding to its channel and all products are summed before multiply by a calibration constant to yield an exposure rate. While Lobdell and Hertel calculated dose using a response matrix based on spectral unfolding technique. From these points of view, we have made an attempt to correlate the counts obtained in scintillator with absorbed dose or ambient dose equivalent. We aimed to calibrate the plastic scintillator energy deposition for dose, by correlate the counts obtained with a particular value of dose. By designed the scintillator to measure at 1 cm tissue depth might be helpful to be used as radiation monitoring or personal dosimeter since the energy response of plastic scintillator is relatively energy independent compared to that of inorganic scintillators. The energy calibration proposed from simple fitting approach had been verified with calculated spectra. This might be considered as a practical approach for technician or radiation workers with sufficient accuracy. The linear behavior of counts per absorbed dose give promising to calibrate scintillator energy deposition to read dose (equivalent dose or absorbed dose) for photons. Thus the scintillator could provide both the energy and dose response simultaneously, which may important in some radiation field of measurements. Currently the scintillator is able to give dose rate value for gamma sources of Cs-137 and Mn-54. The number of counts per unit absorbed dose would likely to vary somewhat with photon energy, although the plastic scintillator should have a tissue dose response that is relatively energy independent. Further analysis will be done on conversion factor parameters so that it could be used in such situations where the radiation field is complex or unknown. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron-Gamma flux and Dose calculations in a Pressurized Water Reactor (PWR)

The Institute of Radiological Protection and Nuclear Safety (IRSN) acts as technical support to the French nuclear safety authorities. In this context, one of its missions is to improve nuclear safety through the enhancement of knowledge regarding operating nuclear power reactors. The issues concerning the aging and the characterisation of the reactor vessel require knowledge of the neutron and gamma radiation environment on the vessel and beyond. Since few years, ENEA (Energia Nucleare e Energie Alternative, i.e. Nuclear Energy and Alternative Energy agency) and IRSN collaborate on Monte-Carlo simulations and Variance Reduction Techniques (VRT), which are used to determine neutron and gamma spectra in and out of the core. Additionally, IRSN participates in the DISCOMS project, which stands for 'Distributed Sensing for Corium Monitoring and Safety', aiming at examining the status of the third barrier of confinement, in order to define possible mitigation strategies in case of a severe accident, namely: i) reactor pressure vessel breakthrough and corium relocation outside the vessel, ii) reactor pit concrete erosion and iii) corium cooling. One of the IRSN tasks in the frame of the DISCOMS project is to provide the radiation level in terms of neutron and gamma doses and flux energy spectra at various locations. This paper summarizes the study performed on the radiation transport in the Tihange-I Belgian nuclear reactor and contributes to several issues requiring the knowledge of the radiation environment in and outside the reactor vessel. This paper gives an overview of the work presented at the ICRS-13 and RPSD-2016 conference (for more details see the proceedings paper)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

STABILITY OF DOW CORNING Q2-3183A ANTIFOAM IN IRRADIATED HYDROXIDE SOLUTION

Researchers at the Savannah River National Laboratory (SRNL) examined the stability of Dow Corning Q2-3183A antifoam to radiation and aqueous hydroxide solutions. Initial foam control studies with Hanford tank waste showed the antifoam reduced foaming. The antifoam was further tested using simulated Hanford tank waste spiked with antifoam that was heated and irradiated (2.1 x 10{sup 4} rad/h) at conditions (90 C, 3 M NaOH, 8 h) expected in the processing of radioactive waste through the Waste Treatment and Immobilization Plant (WTP) at Hanford. After irradiation, the concentration of the major polymer components polydimethylsiloxane (PDMS) and polypropylene glycol (PPG) in the antifoam was determined by gel permeation chromatography (GPC). No loss of the major polymer components was observed after 24 h and only 15 wt% loss of PDMS was reported after 48 h. The presence of degradation products were not observed by gas chromatography (GC), gas chromatography mass spectrometry (GCMS) or high performance liquid chromatography mass spectrometry (HPLC-MS). G values were calculated from the GPC analysis and tabulated. The findings indicate the antifoam is stable for 24 h after exposure to gamma radiation, heat, and alkaline simulated waste.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermoluminescence and glow curves analysis of γ-exposed Eu{sup 3+} doped K{sub 3}Y(PO{sub 4}){sub 2} nanophosphors

Highlights: • First time, a detailed comparative study of the glow curves and kinetic parameters was made on K{sub 3}Y(PO{sub 4}){sub 2} nanophosphor. • Combustion method was employed to synthesize the Eu{sup 3+} doped K{sub 3}Y(PO{sub 4}){sub 2} nanophosphor. • The nanophosphor exhibited sublinear response suggesting that it is suitable for TL dosimetry. - Abstract: Eu{sup 3+} doped K{sub 3}Y(PO{sub 4}){sub 2} nanophosphor was synthesized by combustion synthesis using urea as a fuel. The crystal structure and particle morphology of the nanophosphor were investigated by using X-ray diffraction and transmission electron microscopy, respectively. A Thermoluminescence (TL) study was carried out after exposing the samples to gamma radiation. The TL glow curves exhibited a prominent peak at 407 K and a small hump at 478 K. The intensity of the peaks increased with the increase in the dose of the gamma rays (0.01–5 kGy). The K{sub 3}Y(PO{sub 4}){sub 2}: Eu{sup 3+} (2.5 mol%) nanophosphor exhibited sublinear TL response to γ-radiation over a wide range of gamma doses (0.01–5 kGy). The TLanal program was used to analyze the glow curves of the K{sub 3}Y(PO{sub 4}){sub 2} nanophosphor at different doses (0.2–5 kGy) and different heating rates (3–10 K/s). A comparative study was done for kinetic trapping parameters that were determined by the peak shape methods of Chen, Grossweiner and Lushchik. The frequency factors (s) for each glow peak were also calculated. The values of the activation energy (E) obtained by the TLanal program were in good agreement with those obtained by the peak shape methods. The effect of different amount of doses and different heating rates are discussed.

36 MATERIALS SCIENCE↗

Final LDRD report : advanced plastic scintillators for neutron detection.

This report summarizes the results of a one-year, feasibility-scale LDRD project that was conducted with the goal of developing new plastic scintillators capable of pulse shape discrimination (PSD) for neutron detection. Copolymers composed of matrix materials such as poly(methyl methacrylate) (PMMA) and blocks containing trans-stilbene (tSB) as the scintillator component were prepared and tested for gamma/neutron response. Block copolymer synthesis utilizing tSBMA proved unsuccessful so random copolymers containing up to 30% tSB were prepared. These copolymers were found to function as scintillators upon exposure to gamma radiation; however, they did not exhibit PSD when exposed to a neutron source. This project, while falling short of its ultimate goal, demonstrated the possible utility of single-component, undoped plastics as scintillators for applications that do not require PSD.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal neutron filter design for the neutron radiography facility at the LVR-15 reactor

In 2011 a decision was made to build a neutron radiography facility at one of the unused horizontal channels of the LVR-15 research reactor in Rez, Czech Republic. One of the key conditions for operating an effective radiography facility is the delivery of a high intensity, homogeneous and collimated thermal neutron beam at the sample location. Additionally the intensity of fast neutrons has to be kept as low as possible as the fast neutrons may damage the detectors used for neutron imaging. As the spectrum in the empty horizontal channel roughly copies the spectrum in the reactor core, which has a high ratio of fast neutrons, neutron filter components have to be installed inside the channel in order to achieve desired beam parameters. As the channel design does not allow the instalment of complex filters and collimators, an optimal solution represent neutron filters made of large single-crystal ingots of proper material composition. Single-crystal silicon was chosen as a favorable filter material for its wide availability in sufficient dimensions. Besides its ability to reasonably lower the ratio of fast neutrons while still keeping high intensities of thermal neutrons, due to its large dimensions, it suits as a shielding against gamma radiation from the reactor core. For designing the necessary filter dimensions the Monte-Carlo MCNP transport code was used. As the code does not provide neutron cross-section libraries for thermal neutron transport through single-crystalline silicon, these had to be created by approximating the theory of thermal neutron scattering and modifying the original cross-section data which are provided with the code. Carrying out a series of calculations the filter thickness of 1 m proved good for gaining a beam with desired parameters and a low gamma background. After mounting the filter inside the channel several measurements of the neutron field were realized at the beam exit. The results have justified the expected calculated values. After the successful filter installing and a series of measurements, first test neutron radiography attempts with test samples could been carried out. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Gamma irradiation effects in W films

Using the van Der Pauw methodology, the surface resistivity of irradiated tungsten films deposited on Silicon substrate was measured. The films were exposed to {gamma} radiation using a isotopic {sup 60}Co source in three irradiation stages attaining 40.35 kGy in total dose. The obtained results for superficial resistivity display a time annealing features and their values are proportional to the total dose.

36 MATERIALS SCIENCE↗

Ultrahigh energy neutrinos from superconducting cosmic strings

Superconducting cosmic strings naturally emit highly boosted charge carriers from cusps. This occurs when a cosmic string or a loop moves through a magnetic field and develops an electric current. The charge carriers and the products of their decay, including protons, photons, and neutrinos, are emitted as narrow jets with opening angle {theta}{approx}1/{gamma}{sub c}, where {gamma}{sub c} is the Lorentz factor of the cusp. The excitation of electric currents in strings occurs mostly in clusters of galaxies, which are characterized by magnetic fields B{approx}10{sup -6} G and a filling factor f{sub B}{approx}10{sup -3}. Two string parameters determine the emission of the particles: the symmetry breaking scale {eta}, which for successful applications should be of order 10{sup 9}-10{sup 12} GeV, and the dimensionless parameter i{sub c}, which determines the maximum induced current as J{sub max}=i{sub c}e{eta} and the energy of emitted charge carriers as {epsilon}{sub X}{approx}i{sub c}{gamma}{sub c}{eta}, where e is the electric charge of a particle. For the parameters {eta} and B mentioned above, the Lorentz factor reaches {gamma}{sub c}{approx}10{sup 12} and the maximum particle energy can be as high as {gamma}{sub c}{eta}{approx}10{sup 22} GeV. The diffuse fluxes of ultrahigh energy neutrinos are close to the cascade upper limit, and can be detected by future neutrino observatories. The signatures of this model are: very high energies of neutrinos, in excess of 10{sup 20} eV; correlation of neutrinos with clusters of galaxies; simultaneous appearance of several neutrino-produced showers in the field of view of very large detectors, such as JEM-EUSO; and 10 TeV gamma radiation from the Virgo cluster. The flux of ultrahigh energy protons from cusps may account for a large fraction of the observed events at the highest energies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of HPGe gamma spectrometric detectors systems for Instrumental Neutron Activation Analysis (INAA) at the Colombian Geological Survey

This paper presents the progress made by the Neutron Activation Analysis (NAA) laboratory at the Colombian Geological Survey (SGC in its Spanish acronym), towards the characterization of its gamma spectrometric systems for Instrumental Neutron Activation Analysis (INAA), with the aim of introducing corrections to the measurements by variations in sample geometry. Characterization includes the empirical determination of the interaction point of gamma radiation inside the Germanium crystal, through the application of a linear model and the use of a fast Monte Carlo N-Particle (MCNP) software to estimate correction factors for differences in counting efficiency that arise from variations in sample density between samples and standards.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and Expansion of Research Facilities to Address the Challenges of the Nuclear Industry - 16055

With the wide variety of challenges that surround nuclear decommissioning, bespoke facilities are required to undertake experiments which can inform decision making. Here we describe research carried out at The University of Manchester's Dalton Cumbrian Facility, a custom built research environment which incorporates a 5 MV ion accelerator as well as a self-shielded {sup 60}Co irradiator. The ion accelerator allows the investigation in to the radiolytic consequences of various charged particles, including protons, alpha particles and a variety of heavier (metal and nonmetal) ions, while the {sup 60}Co irradiator allows the effects of gamma radiation to be studied. We provide specific research examples that demonstrate how this equipment can improve our mechanistic understanding of various aspects of the deleterious effects of radiation in the nuclear industry. These examples include applications in waste encapsulation as well as geological disposal and novel surveying techniques. The outlook for future research and expansion of the facility is also presented. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impact of radon gas concentration in the aerosoles profile

Radon gases relased from building materials and from earth surface are the major responsibility of air ionization. Radon nuclear decay can produce an alpha particle with high energy and Radon progeny. This particle and gamma rays can deliver particles in the air and produce ions with different polarities. This ions, because of induced electric charge, can attach with air aerosols and charge them with their electric charge. The charged aerosols can interact with the other aerosols and ions. Because of this exchange, the air conductivity and the aerosol profiles will change dependently by Radon gas concentration and gamma radiation. Observations show an increase in concentration of Radon during the night, and a decrease during the daylight time. The Radon gas concentration changed hour by hour can induce aerosol profile to change. This dependency between the aerosol profiles and the Radon gas concentrations is discussed.

54 ENVIRONMENTAL SCIENCES↗

Department of Energy Office of Legacy Management Progress on Defense-Related Uranium Mines Program - 18119

The Defense-Related Uranium Mines (DRUM) Program provides the structure and basis for the US Department of Energy Office of Legacy Management (LM) to manage the verification and validation (V and V) of defense-related uranium mines (mines) that provided ore to the Atomic Energy Commission from 1947 to 1970. V and V activities are conducted to fully understand the scope of potential problems posed by these mines by determining their location, reclamation or remediation status, and potential impacts to public safety, human health, and the environment. Land management agencies have limited resources and have generally not conducted comprehensive inventories of abandoned uranium mines, thus adding to the need to undertake this program. LM has entered into memoranda of understanding (MOUs) with the US Bureau of Land Management (BLM) and US Forest Service (USFS) to facilitate a better understanding of the scope of the problem posed by these mines. Currently, LM has executed MOUs with the BLM state offices in Colorado, New Mexico, Utah, and Wyoming and the USFS Rocky Mountain Region, which includes the national forests in Colorado, Wyoming, and South Dakota. This collaborative effort with partner agencies has led LM to develop a V and V Work Plan that describes the numerous activities and types of data to be collected at the mines. V and V activities verify actual mine location, collect coordinates of mining-related features, collect radiological data and soil samples, identify potential physical safety hazards, prioritize mines using a risk-based screening approach, and report the information to partner agencies. The partner agencies may use the reports to assess priorities and determine if any further action is warranted. The DRUM Program goals are to: - Improve data quality and content in the LM national inventory of abandoned uranium mines; - Conduct site-specific reconnaissance at mines for data verification and validation; - Exchange mine information with other federal agencies and state governments to help address mines presenting the greatest risks; - Develop reports for each mine that will contain a risk scoring assessment to help each agency develop priorities. The preliminary risk screening methodology was based on a joint effort between LM and BLM to develop factors that would be based on field observations, field data, and laboratory data using a multiple-lines-of-evidence approach. The multiple-lines-of-evidence assessment allows land managers the opportunity and flexibility to query specific criteria and make rankings based on specific priorities. The risk screening for each mine is based on evaluating the primary hazards of physical safety and risks to human health and several modifying factors that include accessibility and ecological/environmental risks. Gamma radiation scans are performed across the disturbed area of the mine, and soil samples are taken from waste rock piles and drainages, when applicable. This paper presents the results of performing inventory, environmental sampling, and risk ranking along with other accomplishments and lessons learned during the initial year of V and V activities and reporting. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effect of the Electric Mode and γ Irradiation on Surface-Defect Formation at the Si–SiO{sub 2} Interface in a MOS Transistor

The results of experimental investigation into surface-defect formation under the effect of gamma-radiation with a dose rate P = 0.1 rad(Si)/s on MOS (metal-oxide-semiconductor) transistors with the n-type channel in the passive and active modes are presented. Two stages of surface-defect formation are observed. A qualitative model is proposed to explain the effect of the the drain transistor voltage on the defect formation process.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spectral Performance of a Composite Single-Crystal Filtered Thermal Neutron Beam for BNCT Research at the University of Missouri

Parameter studies, design calculations and initial neutronic performance measurements have been completed for a new thermal neutron beamline to be used for neutron capture therapy cell and small-animal radiobiology studies at the University of Missouri Research Reactor. The beamline features the use of single-crystal silicon and bismuth sections for neutron filtering and for reduction of incident gamma radiation. The calculated and measured thermal neutron fluxes produced at the irradiation location are 9.6x108 and 8.8x108 neutrons/cm2-s, respectively. Calculated and measured cadmium ratios (Au foils) are 217 and 132. These results indicate a well-thermalized neutron spectrum with sufficient thermal neutron flux for a variety of small animal BNCT studies.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Characterization of secondary phases in modified vertical bridgman growth czt

CdZnTe or 'CZT' crystals are highly suitable for use as a room temperature based spectrometer for the detection and characterization of gamma radiation. Over the last decade, the methods for growing high quality CZT have improved the quality of the produced crystals however there are material features that can influence the performance of these materials as radiation detectors. For example, various structural heterogeneities within the CZT crystals, such as twinning, pipes, grain boundaries (polycrystallinity), and secondary phases (SP) can have a negative impact on the detector performance. In this study, a CZT material was grown by the modified vertical Bridgman growth (MVB) method with zone leveled growth without excess Te in the melt. Visual observations of material from the growth of this material revealed significant voids and SP. Three samples from this material was analyzed using various analytical techniques to evaluate its electrical properties, purity and detector performance as radiation spectrometers and to determine the morphology, dimension and elemental/structural composition of one of the SP in this material. This material was found to have a high resistivity but poor radiation spectrometer performance. It had SP that were rich in polycrystalline aluminum oxide (Al{sub 2}O{sub 3}), metallic Te and polycrystalline CdZnTe and 15 to 50 {micro}m in diameter. Bulk elemental analyses of sister material from elsewhere in the boule did not contain high levels of Al so there is considerable elemental impurity heterogeneity within the boule from this growth.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗