Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gamma Scan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Effects of refractive index mismatch in optical CT imaging of polymer gel dosimeters

Purpose: Proposing an image reconstruction technique, algebraic reconstruction technique-refraction correction (ART-rc). The proposed method takes care of refractive index mismatches present in gel dosimeter scanner at the boundary, and also corrects for the interior ray refraction. Polymer gel dosimeters with high dose regions have higher refractive index and optical density compared to the background medium, these changes in refractive index at high dose results in interior ray bending. Methods: The inclusion of the effects of refraction is an important step in reconstruction of optical density in gel dosimeters. The proposed ray tracing algorithm models the interior multiple refraction at the inhomogeneities. Jacob’s ray tracing algorithm has been modified to calculate the pathlengths of the ray that traverses through the higher dose regions. The algorithm computes the length of the ray in each pixel along its path and is used as the weight matrix. Algebraic reconstruction technique and pixel based reconstruction algorithms are used for solving the reconstruction problem. The proposed method is tested with numerical phantoms for various noise levels. The experimental dosimetric results are also presented. Results: The results show that the proposed scheme ART-rc is able to reconstruct optical density inside the dosimeter better than the results obtained using filtered backprojection and conventional algebraic reconstruction approaches. The quantitative improvement using ART-rc is evaluated using gamma-index. The refraction errors due to regions of different refractive indices are discussed. The effects of modeling of interior refraction in the dose region are presented. Conclusions: The errors propagated due to multiple refraction effects have been modeled and the improvements in reconstruction using proposed model is presented. The refractive index of the dosimeter has a mismatch with the surrounding medium (for dry air or water scanning). The algorithm reconstructs the dose profiles by estimating refractive indices of multiple inhomogeneities having different refractive indices and optical densities embedded in the dosimeter. This is achieved by tracking the path of the ray that traverses through the dosimeter. Extensive simulation studies have been carried out and results are found to be matching that of experimental results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monitoring of inventory in enclosed turbulent liquid tanks using floating gamma-ray sources

An accurate and simple technique utilizing a low-intensity gamma-ray source floating in a vertical tube, whose configuration is tank geometry and size dependent, is shown to eliminate the disturbing effects of turbulent fluid on enclosed tank liquid inventory measurement. The vertical tube aligns the source with detectors positioned outside of the tank, and collapses the turbulent liquid surface to a true average level. The exit attenuation of the information carrying high energy gamma rays is insensitive to liquid surface tubulence, and sensing probe penetrations are not necessary. It is found that for a half-full tank, 1.0 percent statistical error, and 1-s measuring times, that a 220 C Ce-137 source is required for an 8-ft high tank. Consistent experimental results are found for the dual detector method, and results indicate that the accuracy of the scanning side detector method is dependent on the quality of the collimator and degree of lower level energy discrimination.

Klein, R. M.↗

Gamma Knife Radiosurgery for the Treatment of Cystic Cerebral Metastases

Purpose: To assess the role of Gamma Knife radiosurgery (GKRS) in the treatment of nonsurgical cystic brain metastasis, and to determine predictors of response to GKRS. Methods: We reviewed a prospectively maintained database of brain metastases patients treated at our institution between 2006 and 2010. All lesions with a cystic component were identified, and volumetric analysis was done to measure percentage of cystic volume on day of treatment and consecutive follow-up MRI scans. Clinical, radiologic, and dosimetry parameters were reviewed to establish the overall response of cystic metastases to GKRS as well as identify potential predictive factors of response. Results: A total of 111 lesions in 73 patients were analyzed; 57% of lesions received prior whole-brain radiation therapy (WBRT). Lung carcinoma was the primary cancer in 51% of patients, 10% breast, 10% colorectal, 4% melanoma, and 26% other. Fifty-seven percent of the patients were recursive partitioning analysis class 1, the remainder class 2. Mean target volume was 3.3 mL (range, 0.1-23 mL). Median prescription dose was 21 Gy (range, 15-24 Gy). Local control rates were 91%, 63%, and 37% at 6, 12, and 18 months, respectively. Local control was improved in lung primary and worse in patients with prior WBRT (univariate). Only lung primary predicted local control in multivariate analysis, whereas age and tumor volume did not. Lesions with a large cystic component did not show a poorer response compared with those with a small cystic component. Conclusions: This study supports the use of GKRS in the management of nonsurgical cystic metastases, despite a traditionally perceived poorer response. Our local control rates are comparable to a matched cohort of noncystic brain metastases, and therefore the presence of a large cystic component should not deter the use of GKRS. Predictors of response included tumor subtype. Prior WBRT decreased effectiveness of SRS for local control rates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Markovian Statistical Model of Cloud Optical Thickness. Part I: Theory and Examples

We present a generalization of the binary-value Markovian model previously used for statistical characterization of cloud masks to a continuous-value model describing 1D fields of cloud optical thickness (COT). This model has simple functional expressions and is specified by four parameters: the cloud fraction, the autocorrelation (scale) length, and the two parameters of the normalized probability density function of (non-zero) COT values (this PDF is assumed to have gamma-distribution form). Cloud masks derived from this model by separation between the values above and below some threshold in COT appear to have the same statistical properties as in binary-value model described in our previous publications. We demonstrate the ability of our model to generate examples of various cloud-field types by using it to statistically imitate actual cloud observations made by the Research Scanning Polarimeter (RSP) during two field experiments.

binary-value Markovian model↗

SU-E-T-344: Validation and Clinical Experience of Eclipse Electron Monte Carlo Algorithm (EMC)

Purpose: The purpose of this study is to validate Eclipse Electron Monte Carlo (Algorithm for routine clinical uses. Methods: The PTW inhomogeneity phantom (T40037) with different combination of heterogeneous slabs has been CT-scanned with Philips Brilliance 16 slice scanner. The phantom contains blocks of Rando Alderson materials mimicking lung, Polystyrene (Tissue), PTFE (Bone) and PMAA. The phantom has 30×30×2.5 cm base plate with 2cm recesses to insert inhomogeneity. The detector systems used in this study are diode, tlds and Gafchromic EBT2 films. The diode and tlds were included in CT scans. The CT sets are transferred to Eclipse treatment planning system. Several plans have been created with Eclipse Monte Carlo (EMC) algorithm 11.0.21. Measurements have been carried out in Varian TrueBeam machine for energy from 6–22mev. Results: The measured and calculated doses agreed very well for tissue like media. The agreement was reasonably okay for the presence of lung inhomogeneity. The point dose agreement was within 3.5% and Gamma passing rate at 3%/3mm was greater than 93% except for 6Mev(85%). The disagreement can reach as high as 10% in the presence of bone inhomogeneity. This is due to eclipse reporting dose to the medium as opposed to the dose to the water as in conventional calculation engines. Conclusion: Care must be taken when using Varian Eclipse EMC algorithm for dose calculation for routine clinical uses. The algorithm dose not report dose to water in which most of the clinical experiences are based on rather it just reports dose to medium directly. In the presence of inhomogeneity such as bone, the dose discrepancy can be as high as 10% or even more depending on the location of normalization point or volume. As Radiation oncology as an empirical science, care must be taken before using EMC reported monitor units for clinical uses.

60 APPLIED LIFE SCIENCES↗

Multiple error data analysis for RHIC low-energy operations

In FY10, RHIC operated with gold beams at three different energies below its regular injection energy, namely at {radical}s = 5 GeV; 7.7 GeV; and 11.5 GeV: While beam lifetimes of about 10 minutes were achieved at 11.5 GeV and 7.7 GeV; leading to stable collider operation, beam lifetimes during tests at {radical}s = 5 GeV were only of the order of several seconds. Though space charge effects are a major concern in low energy operations due to the 1/{gamma}{sup 2} scaling of the space charge force, these can effectively be ruled out as the main cause of this abysmal performance because of the tiny bunch intensities of approximately 10{sub 8} Au/bunch, compared to 10{sup 9} Au/bunch at the two higher energies. During these 5 GeV tests, large betatron tune spreads were observed, but the extremely short beam lifetime prevented chromaticity measurements. Instead, chromaticities were scanned over a range of 40 units, but to no effect. It was therefore suspected at that time that the large tune spread was caused by higherorder multipole errors in the RHIC magnets.

43 PARTICLE ACCELERATORS↗

Fermi surface of the flat-band intermetallics A P d 3 ( A = Pb , Sn )

The intermetallic phases APd 3 (A = Pb, Sn) were recently predicted to host an unconventional combination of unique electronic structure features, namely, flat bands near the Fermi energy coexisting with topologically protected surface states at the Gamma point. These features each could independently produce alternative electronic states, including electronically or magnetically ordered states coexisting with unconventional edge dominated transport and a significantly large thermopower coexisting with topological characteristics. To explore these expectations, we report the synthesis, structural/chemical characterization, electrical and thermal transport properties, magnetic torque (up to 45 T), and Fermi surface mapping for single crystals produced using the Czochralski technique. X-ray diffraction and scanning transmission electron microscope measurements establish the absence of defects, while small measured values of the thermopower indicate that the Fermi level is located away from the flat-band region. The electronic properties are further clarified by the topography of the Fermi surfaces, measured through the de Haas–van Alphen effect. We find that the Fermi levels are placed at higher energy values than the original ones resulting from the density functional theory calculations, 54 meV higher for PbPd 3 and 68 meV higher for SnPd 3 . Furthermore, the molten flux method was used to synthesize PbPd 3 , yielding nearly identical Fermi surfaces between the specimens grown using different synthesis techniques, indicating the robustness of the Fermi level position. According to the density functional theory calculations, the flat band is mainly formed by the 4d bands of Pd. Thus, we propose monovalent doping on the Pb/Sn site as a viable approach to accessing the flat band while maintaining the unique band structure features of these compounds.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-E-T-32: An Application of GafChromic RTQA2 Film to the Patient Specified Quality Assurance

Purpose: GafChromic RTQA2 film is known as a quality assurance (QA) tool for light field and radiation field verification. This study is attempted to apply the RTQA2 film to the patient specified quality assurance. Methods: Pre-irradiated and post-irradiated RTQA2 films were scanned in a reflection mode using a flatbed scanner. A plan-based dose calibration method utilized the mapping information of calculated dose image and measured film image to create a dose vs. pixel value calibration model. This model was used to calibrate the measured film image from the pixel value (gray value) image to the dose image. The dose agreement between calculated and measured dose images were analyzed using the gamma analysis. To evaluate the feasibility of this method, three clinical approved RapidArc cases (one abdomen cancer and two head-and-neck cancer patients) were tested. The tolerance of 3% dose difference and 3 mm distance to agreement (DTA) and gamma index ≤ 1 were set for the analysis. Results: The calibrated film dose image from measurement was successfully compared to the predicted dose image from the commercial treatment planning. The gamma analysis results showed good consistency. Gamma passing rates were 99.02%, 94.84%, and 98.33% for the three patients, respectively. Conclusion: The plan based calibration method has the feasibility for dose verification without shortages of film batch and development time variation.

60 APPLIED LIFE SCIENCES↗

SU-F-P-34: Commission of Enhanced Dynamic Wedge of Varian Truebeam Linac System with Feature Study

Purpose: To evaluate an Enhanced Dynamic Wedge (EDW) as part of machine commission process with feature study. Methods: The EDW system in this study was from a Truebeam, which is the Linear accelerator manufactured by Varian Medical Systems. The EDW feature vectors includes selected elements. These elements were dosimetric output spots check, field size, wedge angles, dose rate, collimator orientation, and different energy settings. Point dose measurement was done by a PTW farmer chamber, and profiles were measured by Gafchromic EBT2 films positing at different depths of the Solidwater based on the study elements. The output spot measurements were done with PTW farmer chamber with Solidwater setting for all orientation and wedge angles in the EDW system. The profiles comparisons were done by IMRT measurement function in RIT software at version 6.3. And the films were scanned by Vidar scanner. Dosimetry calculation were done by using the same Solidwater scanned by GE LightSpeed CT in Eclipse Treatment Planning System (TPS). Then measurements were compared to simulation results in TPS. Results: The energy average percentage difference between chamber measurement and TPS was 0.16% with standard deviation (SD) at 0.93%. For selected features, the average percentage difference between film measurement and computation was 0.93% with SD at 1.55% in horizontal profiles, and 1.18% with SD at 0.98% at vertical profiles. The average gamma difference for film measurement and TPS computing results was at 0.924 with SD at 0.314. Conclusion: A feature vector was developed to describe the commission of EDW, and developing a complete set of features for sufficiency of commission of a LINAC function could provide optimal commission instance with acceptable confident level of clinical application of the machine. Given the institution specific vector pattern and big data process, it could provide wide range clinical outcome comparison information in application of EDW.

60 APPLIED LIFE SCIENCES↗

Experimental studies of plasma-antenna coupling with the JET Alfven Eigenmode Active Diagnostic

This paper presents a dedicated study of plasma-antenna (PA) coupling with the Alfven Eigenmode Active Diagnostic (AEAD) in JET. Stable AEs and their resonant frequencies f, damping rates gamma < 0, and toroidal mode numbers n are measured for various PA separations and limiter versus X-point magnetic configurations. Two stable AEs are observed to be resonantly excited at distinct low and high frequencies in limiter plasmas. The values of f and n do not vary with PA separation. However, |gamma| increases with PA separation for the low-f, but not high-f, mode, yet this may be due to slightly different edge conditions. The high-f AE is detected throughout the transition from limiter to X-point configuration, though its damping rate increases; the low-f mode, on the other hand, becomes unidentifiable. The linear resistive MHD code CASTOR is used to simulate the frequency scan of an AEAD-like external antenna. For the limiter pulses, the high-f mode is determined to be an n = 0 GAE, while the low-f mode is likely an n = 2 TAE. During the transition from limiter to X-point configuration, CASTOR indicates that n = 1 and 2 EAEs are excited in the edge gap. These results extend previous experimental studies in JET and Alcator C-Mod; validate the computational work performed by Dvornova et al 2020 Phys. Plasmas 27 012507; and provide guidance for the optimization of PA coupling in upcoming JET energetic particle experiments, for which the AEAD will aim to identify the contribution of alpha particles to AE drive during the DT campaign.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ADVANCED X-BAND TEST ACCELERATOR FOR HIGH BRIGHTNESS ELECTRON AND GAMMA RAY BEAMS

In support of Compton scattering gamma-ray source efforts at LLNL, a multi-bunch test stand is being developed to investigate accelerator optimization for future upgrades. This test stand will enable work to explore the science and technology paths required to boost the current 10 Hz monoenergetic gamma-ray (MEGa-Ray) technology to an effective repetition rate exceeding 1 kHz, potentially increasing the average gamma-ray brightness by two orders of magnitude. Multiple bunches must be of exceedingly high quality to produce narrow-bandwidth gamma-rays. Modeling efforts will be presented, along with plans for a multi-bunch test stand at LLNL. The test stand will consist of a 5.5 cell X-band rf photoinjector, single accelerator section, and beam diagnostics. The photoinjector will be a high gradient standing wave structure, featuring a dual feed racetrack coupler. The accelerator will increase the electron energy so that the emittance can be measured using quadrupole scanning techniques. Multi-bunch diagnostics will be developed so that the beam quality can be measured and compared with theory. Design will be presented with modeling simulations, and layout plans.

42 ENGINEERING↗

Advanced X-Band Test Accelerator for High Brightness Electron and Gamma Ray Beams

In support of Compton scattering gamma-ray source efforts at LLNL, a multi-bunch test stand is being developed to investigate accelerator optimization for future upgrades. This test stand will enable work to explore the science and technology paths required to boost the current 10 Hz monoenergetic gamma-ray (MEGa-Ray) technology to an effective repetition rate exceeding 1 kHz, potentially increasing the average gamma-ray brightness by two orders of magnitude. Multiple bunches must be of exceedingly high quality to produce narrow-bandwidth gamma-rays. Modeling efforts will be presented, along with plans for a multi-bunch test stand at LLNL. The test stand will consist of a 5.5 cell X-band rf photoinjector, single accelerator section, and beam diagnostics. The photoinjector will be a high gradient standing wave structure, featuring a dual feed racetrack coupler. The accelerator will increase the electron energy so that the emittance can be measured using quadrupole scanning techniques. Multi-bunch diagnostics will be developed so that the beam quality can be measured and compared with theory. Design will be presented with modeling simulations, and layout plans.

43 PARTICLE ACCELERATORS↗

Shape-controlled synthesis and properties of dandelion-like manganese sulfide hollow spheres

Graphical abstract: Dandelion-like MnS hollow spheres assembled with nanorods could be successfully synthesized in large quantities through a simple and convenient hydrothermal synthetic method under mild conditions using soluble hydrated manganese chloride as Mn source, L-cysteine as both a precipitator and complexing reagent. The dandelion-like MnS hollow spheres might have potential applications in microdevices and magnetic cells. Highlights: ► MnS hollow spheres assembled with nanorods could be synthesized. ► The morphologies and sizes of final products could be controlled. ► Possible formation mechanism of MnS hollow spheres is proposed. -- Abstract: Dandelion-like gamma-manganese (II) sulfide (MnS) hollow spheres assembled with nanorods have been prepared via a hydrothermal process in the presence of L-cysteine and polyvinylpyrrolidone (PVP). L-cysteine was employed as not only sulfur source, but also coordinating reagent for the synthesis of dandelion-like MnS hollow spheres. The morphology, structure and properties of as-prepared products have been investigated in detail by X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM), energy dispersive X-ray spectroscopy (EDS), selected area electron diffraction (SAED), high-resolution transmission electron microscopy (HRTEM) and photoluminescence spectra (PL). The probable formation mechanism of as-prepared MnS hollow spheres was discussed on the basis of the experimental results. This strategy may provide an effective method for the fabrication of other metal sulfides hollow spheres.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The evaluation of a 2D diode array in “magic phantom” for use in high dose rate brachytherapy pretreatment quality assurance

Purpose: High dose rate (HDR) brachytherapy is a treatment method that is used increasingly worldwide. The development of a sound quality assurance program for the verification of treatment deliveries can be challenging due to the high source activity utilized and the need for precise measurements of dwell positions and times. This paper describes the application of a novel phantom, based on a 2D 11 × 11 diode array detection system, named “magic phantom” (MPh), to accurately measure plan dwell positions and times, compare them directly to the treatment plan, determine errors in treatment delivery, and calculate absorbed dose. Methods: The magic phantom system was CT scanned and a 20 catheter plan was generated to simulate a nonspecific treatment scenario. This plan was delivered to the MPh and, using a custom developed software suite, the dwell positions and times were measured and compared to the plan. The original plan was also modified, with changes not disclosed to the primary authors, and measured again using the device and software to determine the modifications. A new metric, the “position–time gamma index,” was developed to quantify the quality of a treatment delivery when compared to the treatment plan. The MPh was evaluated to determine the minimum measurable dwell time and step size. The incorporation of the TG-43U1 formalism directly into the software allows for dose calculations to be made based on the measured plan. The estimated dose distributions calculated by the software were compared to the treatment plan and to calibrated EBT3 film, using the 2D gamma analysis method. Results: For the original plan, the magic phantom system was capable of measuring all dwell points and dwell times and the majority were found to be within 0.93 mm and 0.25 s, respectively, from the plan. By measuring the altered plan and comparing it to the unmodified treatment plan, the use of the position–time gamma index showed that all modifications made could be readily detected. The MPh was able to measure dwell times down to 0.067 ± 0.001 s and planned dwell positions separated by 1 mm. The dose calculation carried out by the MPh software was found to be in agreement with values calculated by the treatment planning system within 0.75%. Using the 2D gamma index, the dose map of the MPh plane and measured EBT3 were found to have a pass rate of over 95% when compared to the original plan. Conclusions: The application of this magic phantom quality assurance system to HDR brachytherapy has demonstrated promising ability to perform the verification of treatment plans, based upon the measured dwell positions and times. The introduction of the quantitative position–time gamma index allows for direct comparison of measured parameters against the plan and could be used prior to patient treatment to ensure accurate delivery.

60 APPLIED LIFE SCIENCES↗

Optical interstellar lines toward 18 stars of low reddening. III

Photoelectric scans of the interstellar D-line of Na I and the K-line of Ca II are compared with those of H I and H sub 2. Three general conclusions are drawn from the observations: (1) normal Na I/H ratios are found in 14 of the 18 cases studied, most likely due to absorption in cool, dense clouds; (2) low Na I/H ratios are observed in the direction of Gamma-Pegasus and Mu-Scorpio, implying that absorption occurs in clouds of warm (over 100 K) gas, or through extended paths of cool gas with low ionization; and (3) the absence of Na I, H I, and H sub 2 lines toward Nu-Scorpio and Sigma-Sagittarius indicates that little neutral gas is present along these light paths.

Hobbs, L. M.↗

Polarized View of Supercooled Liquid Water Clouds

Supercooled liquid water (SLW) clouds, where liquid droplets exist at temperatures below 0 C present a well known aviation hazard through aircraft icing, in which SLW accretes on the airframe. SLW clouds are common over the Southern Ocean, and climate-induced changes in their occurrence is thought to constitute a strong cloud feedback on global climate. The two recent NASA field campaigns POlarimeter Definition EXperiment (PODEX, based in Palmdale, California, January-February 2013) and Studies of Emissions and Atmospheric Composition, Clouds and Climate Coupling by Regional Surveys (SEAC4RS, based in Houston, Texas in August- September 2013) provided a unique opportunity to observe SLW clouds from the high-altitude airborne platform of NASA's ER-2 aircraft. We present an analysis of measurements made by the Research Scanning Polarimeter (RSP) during these experiments accompanied by correlative retrievals from other sensors. The RSP measures both polarized and total reflectance in 9 spectral channels with wavelengths ranging from 410 to 2250 nm. It is a scanning sensor taking samples at 0.8deg intervals within 60deg from nadir in both forward and backward directions. This unique angular resolution allows for characterization of liquid water droplet size using the rainbow structure observed in the polarized reflectances in the scattering angle range between 135deg and 165deg. Simple parametric fitting algorithms applied to the polarized reflectance provide retrievals of the droplet effective radius and variance assuming a prescribed size distribution shape (gamma distribution). In addition to this, we use a non-parametric method, Rainbow Fourier Transform (RFT),which allows retrieval of the droplet size distribution without assuming a size distribution shape. We present an overview of the RSP campaign datasets available from the NASA GISS website, as well as two detailed examples of the retrievals. In these case studies we focus on cloud fields with spatial features varying between glaciated and liquid phases at altitudes as high as 10 km, which correspond to temperatures close to the homogeneous freezing temperature of pure water drops (about -35 C or colder). The multimodal droplet size distributions retrieved from RSP data in these cases are consistent with the multi-layer cloud structure observed by correlative Cloud Physics Lidar (CPL) measurements.

Clouds↗

Protective Effect of Pyruvate Against Radiation-Induced Damage in Collagenized Tissues

Exposure to high doses of ionizing radiation produces both acute and late effects on the collagenized tissues and have profound effects on wound healing. Because of the crucial practical importance for new radioprotective agents, our study has been focused on evaluation of the efficacy of non-toxic naturally occurring compounds to protect tissue integrity against high-dose gamma radiation. Here, we demonstrate that molecular integrity of collagen may serve as a sensitive biological marker for quantitative evaluation of molecular damage to collagenized tissue and efficacy of radioprotective agents. Increasing doses of gamma radiation (0-50kGy) result in progressive destruction of the native collagen fibrils, which provide a structural framework, strength, and proper milieu for the regenerating tissue. The strategy used in this study involved the thermodynamic specification of all structural changes in collagenized matrix of skin, aortic heart valve, and bone tissue induced by different doses and conditions of g-irradiation. This study describes a simple biophysical approach utilizing the Differential Scanning Calorimetry (DSC) to characterize the structural resistance of the aortic valve matrix exposed to different doses of g-irradiation. It allows us to identify the specific response of each constituent as well as to determine the influence of the different treatments on the characteristic parameters of protein structure. We found that pyruvate, a substance that naturally occurs in the body, provide significant protection (up to 80%) from biochemical and biomechanical damage to the collagenized tissue through the effective targeting of reactive oxygen species. The recently discovered role of pyruvate in the cell antioxidant defense to O2 oxidation, and its essential constituency in the daily human diet, indicate that the administration of pyruvate-based radioprotective formulations may provide safe and effective protection from deleterious effects of ionizing radiation.

Differential Scanning Calorimetry↗

SU-E-E-12: Validation of the Implementation of Different CT Scanners in Proton Treatment Planning

Purpose: To quantify the impact of the relationship of CT number and Relative Stopping Power (RSP) among different CT-scanners in the evaluation of dose distribution, for different tumor sites and proton therapy modalities like Pencil Beam and Uniform Scanning. Methods: The same tissue characterization phantom was used to analyze the difference in the X-rays energy spectra of 2 CT scanners of the same vendor. One CT is for planning and the other for treatment verification. The Hounsfield unit (HU) variations and associated dosimetric uncertainty were investigated in uniform scanning and pencil beam treatment plans of different sites. At the same time comparisons of the CT calibration curve were done using the same acquisition protocols. The phantom was imaged on a 16 multi-row CT scanner, with energies of 120 and 140 kVp,currents of 263 and 245 mA and slice thickness of 2 and 3mm respectively. The dosimetric uncertainty of the plans was evaluated in a homogeneus phantom comparing DVHs, gamma index criteria 3% 3mm, and range between them. Results: The variation of HU was within the standard deviation of the average for each tissue substitute. The curves fitted with a bilinear interpolation show a maximum deviation in high density materials like cortical bone and solid water, where the HU values deviated more than 0,6% for the 120kVp protocol. For the others curves the deviation was more than 2% for low densities materials. The gamma index uncertainty criteria passed in all the cases. Conclusion: The HU variations for the different scanners were ≤3%. Lower than the 3,5% uncertainties considered in our treatment planning system. The dosimetric analysis shows that the X-ray spectrum has a small effect on the HU-RSP curve, allowing the use of a single tissue characterization curve in our proton treatment planning system for plans verifications.

60 APPLIED LIFE SCIENCES↗