Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Resolutions Optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

NASA Tech Briefs, July 2007

Topics covered include: Miniature Intelligent Sensor Module; "Smart" Sensor Module; Portable Apparatus for Electrochemical Sensing of Ethylene; Increasing Linear Dynamic Range of a CMOS Image Sensor; Flight Qualified Micro Sun Sensor; Norbornene-Based Polymer Electrolytes for Lithium Cells; Making Single-Source Precursors of Ternary Semiconductors; Water-Free Proton-Conducting Membranes for Fuel Cells; Mo/Ti Diffusion Bonding for Making Thermoelectric Devices; Photodetectors on Coronagraph Mask for Pointing Control; High-Energy-Density, Low-Temperature Li/CFx Primary Cells; G4-FETs as Universal and Programmable Logic Gates; Fabrication of Buried Nanochannels From Nanowire Patterns; Diamond Smoothing Tools; Infrared Imaging System for Studying Brain Function; Rarefying Spectra of Whispering-Gallery-Mode Resonators; Large-Area Permanent-Magnet ECR Plasma Source; Slot-Antenna/Permanent-Magnet Device for Generating Plasma; Fiber-Optic Strain Gauge With High Resolution And Update Rate; Broadband Achromatic Telecentric Lens; Temperature-Corrected Model of Turbulence in Hot Jet Flows; Enhanced Elliptic Grid Generation; Automated Knowledge Discovery From Simulators; Electro-Optical Modulator Bias Control Using Bipolar Pulses; Generative Representations for Automated Design of Robots; Mars-Approach Navigation Using In Situ Orbiters; Efficient Optimization of Low-Thrust Spacecraft Trajectories; Cylindrical Asymmetrical Capacitors for Use in Outer Space; Protecting Against Faults in JPL Spacecraft; Algorithm Optimally Allocates Actuation of a Spacecraft; and Radar Interferometer for Topographic Mapping of Glaciers and Ice Sheets.

Source record↗

A high-resolution two-dimensional imaging velocimeter

Velocity interferometers are typically used to measure velocities of surfaces at a single point or along an imaged line as a function of time. We describe an optical arrangement that enables high-resolution measurements of the two-dimensional velocity field across a shock front or shocked interface. The technique is employed to measure microscopic fluctuations in shock fronts that have passed through materials being considered as ablators for indirect-drive inertial confinement fusion. With picosecond time resolution the instrument captures velocity modes with wavelengths as short as 2.5 {mu}m at a resolution of {approx}10 m/s rms on velocity fields averaging many km/s over an 800 {mu}m field of view.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Airborne Multiwavelength High Spectral Resolution Lidar (HSRL-2) observations during TCAP 2012: vertical profiles of optical and microphysical properties of a smoke/urban haze plume over the northeastern coast of the US

Here, we present measurements acquired by the world's first airborne 3 backscatter (β) + 2 extinction (α) High Spectral Resolution Lidar (HSRL-2). HSRL-2 measures particle backscatter coefficients at 355, 532, and 1064 nm, and particle extinction coefficients at 355 and 532 nm. The instrument has been developed by the NASA Langley Research Center. The instrument was operated during Phase 1 of the Department of Energy (DOE) Two-Column Aerosol Project (TCAP) in July 2012. We observed pollution outflow from the northeastern coast of the US out over the western Atlantic Ocean. Lidar ratios were 50–60 sr at 355 nm and 60–70 sr at 532 nm. Extinction-related Ångström exponents were on average 1.2–1.7, indicating comparably small particles. Our novel automated, unsupervised data inversion algorithm retrieved particle effective radii of approximately 0.2 μm, which is in agreement with the large Angstrom exponents. We find good agreement with particle size parameters obtained from coincident in situ measurements carried out with the DOE Gulfstream-1 aircraft.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

ADAPTIVE OPTICS IMAGES OF KEPLER OBJECTS OF INTEREST

All transiting planets are at risk of contamination by blends with nearby, unresolved stars. Blends dilute the transit signal, causing the planet to appear smaller than it really is, or produce a false-positive detection when the target star is blended with eclipsing binary stars. This paper reports on high spatial-resolution adaptive optics images of 90 Kepler planetary candidates. Companion stars are detected as close as 0.''1 from the target star. Images were taken in the near-infrared (J and Ks bands) with ARIES on the MMT and PHARO on the Palomar Hale 200 inch telescope. Most objects (60%) have at least one star within 6'' separation and a magnitude difference of 9. Eighteen objects (20%) have at least one companion within 2'' of the target star; six companions (7%) are closer than 0.''5. Most of these companions were previously unknown, and the associated planetary candidates should receive additional scrutiny. Limits are placed on the presence of additional companions for every system observed, which can be used to validate planets statistically using the BLENDER method. Validation is particularly critical for low-mass, potentially Earth-like worlds, which are not detectable with current-generation radial velocity techniques. High-resolution images are thus a crucial component of any transit follow-up program.

79 ASTRONOMY AND ASTROPHYSICS↗

Optical Investigation of a Partial Fuel Stratification Strategy to Stabilize Overall Lean Operation of a DISI Engine Fueled with Gasoline and E30

This paper offers new insights into a partial fuel stratification (PFS) combustion strategy that has proven to be effective at stabilizing overall lean combustion in direct injection spark ignition engines. To this aim, high spatial and temporal resolution optical diagnostics were applied in an optically accessible engine working in PFS mode for two fuels and two different durations of pilot injection at the time of spark: 210 µs and 330 µs for E30 (gasoline blended with ethanol by 30% volume fraction) and gasoline, respectively. In both conditions, early injections during the intake stroke were used to generate a well-mixed lean background. The results were compared to rich, stoichiometric and lean well-mixed combustion with different spark timings. In the PFS combustion process, it was possible to detect a non-spherical and highly wrinkled blue flame, coupled with yellow diffusive flames due to the combustion of rich zones near the spark plug. The initial flame spread for both PFS cases was faster compared to any of the well-mixed cases (lean, stoichiometric and rich), suggesting that the flame propagation for PFS is enhanced by both enrichment and enhanced local turbulence caused by the pilot injection. Different spray evolutions for the two pilot injection durations were found to strongly influence the flame kernel inception and propagation. PFS with pilot durations of 210 µs and 330 µs showed some differences in terms of shapes of the flame front and in terms of extension of diffusive flames. Yet, both cases were highly repeatable.

33 ADVANCED PROPULSION SYSTEMS↗

Phase Length Optical Phase-Locked-Loop Sensor

The invention is a device that provides a high resolution measurement of the change in optical phase length from the device optical system source to an optical reflector. The invention consists of a optical phase locked loop that uses a laser beam as a carrier of an intensity modulated energy source. The novelty of the invention appears to lie in the overall combination of elements which provide high resolution without loss of wide dynamic range. The invention does not depend on coherent reflection from a target, and thus can measure targets that do not have special preparation or corner reflectors. The use of carrier modulation achieves high resolution without the problems of high speed pulse duration systems. Thus the invention has the advantages of simplicity, low cost, and small size without sacrificing resolution.

Heyman, Joseph S.↗

High-resolution multi-band imaging for validation and characterization of small Kepler planets

High-resolution ground-based optical speckle and near-infrared adaptive optics images are taken to search for stars in close angular proximity to host stars of candidate planets identified by the NASA Kepler Mission. Neighboring stars are a potential source of false positive signals. These stars also blend into Kepler light curves, affecting estimated planet properties, and are important for an understanding of planets in multiple star systems. Deep images with high angular resolution help to validate candidate planets by excluding potential background eclipsing binaries as the source of the transit signals. A study of 18 Kepler Object of Interest stars hosting a total of 28 candidate and validated planets is presented. Validation levels are determined for 18 planets against the likelihood of a false positive from a background eclipsing binary. Most of these are validated at the 99% level or higher, including five newly validated planets in two systems: Kepler-430 and Kepler-431. The stellar properties of the candidate host stars are determined by supplementing existing literature values with new spectroscopic characterizations. Close neighbors of seven of these stars are examined using multi-wavelength photometry to determine their nature and influence on the candidate planet properties. Most of the close neighbors appear to be gravitationally bound secondaries, while a few are best explained as closely co-aligned field stars. Revised planet properties are derived for each candidate and validated planet, including cases where the close neighbors are the potential host stars.

79 ASTRONOMY AND ASTROPHYSICS↗

Optical-system design for next-generation pushbroom sensors

Next-generation pushbroom sensors for earth observation require high-performance optics that provide high spatial resolution over wide fields of view. Specifically, blur diameters on the order of 10 to 15 microns are needed over 5 to 15 deg fields. In addition to this fundamental level of optical performance, other characteristics, such as spatial coregistration of spectral bands, flat focal plane, telecentricity, and workable pupil location are significant instrument design considerations. The detector-assembly design, optical line-of-sight pointing method and sensor packaging all hinge on these secondary attributes. Moreover, the need for broad spectral coverage, ranging from 0.4 to 12.5 microns, places an additional constraint on optical design. This paper presents alternative design forms that are candidates for wide-field pushbroom sensors, and discusses the instrument-design tradeoffs that are linked to the selection of these alternate optical approaches.

Mika, A. M.↗

High-resolution x-ray guided three-dimensional diffuse optical tomography of joint tissues in hand osteoarthritis: Morphological and functional assessments

Purpose: The aim of this study was to investigate the potential use of multimodality functional imaging techniques to identify the quantitative optical findings that can be used to distinguish between osteoarthritic and normal finger joints. Methods: Between 2006 and 2009, the distal interphalangeal finger joints from 40 female subjects including 22 patients and 18 healthy controls were examined clinically and scanned by a hybrid imaging system. This system integrated x-ray tomosynthetic setup with a diffuse optical imaging system. Optical absorption and scattering images were recovered based on a regularization-based hybrid reconstruction algorithm. A receiver operating characteristic curve was used to calculate the statistical significance of specific optical features obtained from osteoarthritic and healthy joints groups. Results: The three-dimensional optical and x-ray images captured made it possible to quantify optical properties and joint space width of finger joints. Based on the recovered optical absorption and scattering parameters, the authors observed statistically significant differences between healthy and osteoarthritis finger joints. Conclusions: The statistical results revealed that sensitivity and specificity values up to 92% and 100%, respectively, can be achieved when optical properties of joint tissues were used as classifiers. This suggests that these optical imaging parameters are possible indicators for diagnosing osteoarthritis and monitoring its progression.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Zodiacal exoplanets in time (Zeit). I. A Neptune-sized planet orbiting an M4.5 dwarf in the Hyades star cluster

Studying the properties of young planetary systems can shed light on how the dynamics and structure of planets evolve during their most formative years. Recent K2 observations of nearby young clusters (10–800 Myr) have facilitated the discovery of such planetary systems. Here we report the discovery of a Neptune-sized planet transiting an M4.5 dwarf (K2-25) in the Hyades cluster (650–800 Myr). The light curve shows a strong periodic signal at 1.88 days, which we attribute to spot coverage and rotation. We confirm that the planet host is a member of the Hyades by measuring the radial velocity of the system with the high-resolution near-infrared spectrograph Immersion Grating Infrared Spectrometer. This enables us to calculate a distance based on K2-25's kinematics and membership to the Hyades, which in turn provides a stellar radius and mass to ≃5%–10%, better than what is currently possible for most Kepler M dwarfs (12%–20%). We use the derived stellar density as a prior on fitting the K2 transit photometry, which provides weak constraints on eccentricity. Utilizing a combination of adaptive optics imaging and high-resolution spectra, we rule out the possibility that the signal is due to a bound or background eclipsing binary, confirming the transits’ planetary origin. K2-25b has a radius (3.43{sub −0.31}{sup +0.95} R{sub ⊕}) much larger than older Kepler planets with similar orbital periods (3.485 days) and host-star masses (0.29 M{sub ⊙}). This suggests that close-in planets lose some of their atmospheres past the first few hundred million years. Additional transiting planets around the Hyades, Pleiades, and Praesepe clusters from K2 will help confirm whether this planet is atypical or representative of other close-in planets of similar age.

79 ASTRONOMY AND ASTROPHYSICS↗

Ocean Subsurface Study from ICESat-2 Mission

NASA has launched the ICESat-2 mission in September 2018 with the primary purpose of monitoring changes in the cryosphere. Fortunately, the measured photons over ocean region provide great opportunity for the ocean subsurface study. We have proposed a novel algorithm to determine ocean subsurface optical properties, such as, diffuse attenuated coefficient, kd (/m), total backscattering coefficients bb (/m), attenuated backscatter coefficient and particulate backscattering coefficients b(sub bp) (/m) from ICESat-2/ATLAS lidar measurements. Our ICESat-2 ocean subsurface results reveal high vertical resolution of these optical properties through the water column that are hidden from the passive ocean color record. Moreover, we can estimate the particulate organic carbon (POC) and phytoplankton carbon biomass based on the ICESat-2 retrieved particulate backscattering coefficients b( sub bp) results. We will present and discuss the first ICESat-2 ocean subsurface profile results, especially in polar region where passive ocean color measurements are difficult to make. We will also present the multiple scattering effects on the ocean subsurface optical properties retrieval.

Xiaomei Lu↗

Design of NEID, an Extreme Precision Doppler Spectrograph for WIYN

We have developed an optical design for a high resolution spectrograph in response to NASA's call for an extreme precision Doppler spectrometer (EPDS) for the WIYN telescope. Our instrument covers a wavelength range of 380 to 930 nm using a single detector and with a resolution of 100,000. To deliver the most stable spectrum, we avoid the use of an image slicer, in favor of a large (195 mm diameter) beam footprint on a 1x2 mosaic R4 Echelle grating. The optical design is based on a classic white pupil layout, with a single parabolic mirror that is used as the main and transfer collimator. Cross dispersion is provided by a single large PBM2Y glass prism. The refractive camera consists of only four rotationally symmetric lenses made from i-Line glasses, yet delivers very high image quality over the full spectral bandpass. We present the optical design of the main spectrograph bench and discuss the design trade-offs and expected performance.

Optics↗

Modeling Methods for 3D Lightning Mapping from Space

Global lightning detection has advanced greatly over the past few decades both on ground and from orbit. Ground-based systems like the Lightning Mapping Array (LMA) excel at high-precision 3D reconstruction of local flashes, while spaceborne lightning sensors have much larger potential coverage but have been limited by coarser resolution and often rely on data from other instruments to determine flash location. The primary focus of this study is to examine the level of flash detail that can be expected from one or more low-Earth orbiting small satellites that combine VHF and optical measurements of lightning, which is a new mission concept called CubeSpark. The goal of CubeSpark is to map the 3D charge structure of thunderstorms at 1-2 km spatial resolution on a global scale, enabling a host of new atmospheric and space electricity studies. In order to maximize the potential data quality and minimize potential cost, flashes were simulated beneath single- and multi-satellite configurations. In the multi-satellite approach, RF detectors on each of the six satellites would measure the arrival times of impulsive VHF sources to collectively pinpoint their locations in 3D and reconstruct flashes with higher resolution than has been achieved from space. A single-station approach for 3D observation of lightning would follow the method of determining altitudes of strong VHF sources that produce trans-ionospheric pulse pairs (TIPPs) while relying on an on-board high-resolution optical day/night lightning mapper for approximate horizontal flash locations. Here we present preliminary results comparing the expected data fidelity and accuracy between these methods to inform potential satellite missions like CubeSpark.

lightning↗

JPL activities on development of acousto-optic tunable filter imaging spectrometer

Recent activities of JPL in the development of a new type of imaging spectrometers for earth observation and planetary exploration are reported. This instrument uses the acousto-optic tunable filter (AOTF) as high resolution and fast programmable bandpass filter. AOTF operates in the principle of acousto-optic interaction in an anisotropic medium. This filter can be tuned in sequential, random, and multiwavelength access modes, providing observational flexibility. The diffraction process in the filter generates two diffracted monochromatic beams with polarization orthogonal to each other, creating a unique capability to measure both polarimetric and spectral properties of the incoming light simultaneously with a single instrument. The device gives wide wavelength operations with reasonably large throughput. In addition, it is in a compact solid-state structure without moving parts, providing system reliability. These attractive features give promising opportunities to develop a new generation of airborne/spaceborne and ground, real-time, imaging spectrometer systems for remote sensing applications.

Cheng, Li-Jen↗

Study of Luminescence Characteristics of Trivalent Terbium in Silicate Glass

An important use of silicate glasses doped with terbium oxide (Tb2O3) is their use as fiber optic sensors for high-resolution imaging applications requiring the detection of x-rays (e.g. tomography and radiography). The x-ray radiation is absorbed by the glass, producing electron-hole pairs (excitons). The excitons migrate through the glass matrix and then recombine, emitting characteristic Tb(3+) luminescence in the optical wavelength region. This emission is due to forbidden transitions of 4f electrons and therefore has a long decay time. Long decay time is undesirable when imaging transient events since it results in blurring in time of the images. It has been reported elsewhere that in crystals Tb(3+) ions can act both as luminescence centers and as fluorescence traps. These traps can capture excitons and delay their recombination. This delayed fluorescence is seen as a long lived, secondary component to the luminescence decay curve, or afterglow. Such a secondary decay component to the luminescence decay of Tb(3+) has been observed before in soda glass following pulsed optical excitation. In order to determine the conditions under which afterglow occurs, an understanding of the material's luminescent properties is required.

West, Mike S.↗

Empirical electro-optical and x-ray performance evaluation of CMOS active pixels sensor for low dose, high resolution x-ray medical imaging

Monolithic complementary metal oxide semiconductor (CMOS) active pixel sensors with high performance have gained attention in the last few years in many scientific and space applications. In order to evaluate the increasing capabilities of this technology, in particular where low dose high resolution x-ray medical imaging is required, critical electro-optical and physical x-ray performance evaluation was determined. The electro-optical performance includes read noise, full well capacity, interacting quantum efficiency, and pixels cross talk. The x-ray performance, including x-ray sensitivity, modulation transfer function, noise power spectrum, and detection quantum efficiency, has been evaluated in the mammographic energy range. The sensor is a 525x525 standard three transistor CMOS active pixel sensor array with more than 75% fill factor and 25x25 {mu}m pixel pitch. Reading at 10 f/s, it is found that the sensor has 114 electrons total additive noise, 10{sup 5} electrons full well capacity with shot noise limited operation, and 34% interacting quantum efficiency at 530 nm. Two different structured CsI:Tl phosphors with thickness 95 and 115 {mu}m, respectively, have been optically coupled via a fiber optic plate to the array resulting in two different system configurations. The sensitivity of the two different system configurations was 43 and 47 electrons per x-ray incident on the sensor. The MTF at 10% of the two different system configurations was 9.5 and 9 cycles/mm with detective quantum efficiency of 0.45 and 0.48, respectively, close to zero frequency at {approx}0.44 {mu}C/kg (1.72 mR) detector entrance exposure. The detector was quantum limited at low spatial frequencies and its performance was comparable with high resolution a:Si and charge coupled device based x-ray imagers. The detector also demonstrates almost an order of magnitude lower noise than active matrix flat panel imagers. The results suggest that CMOS active pixel sensors when coupled to structured CsI:Tl can be used for conventional and advanced digital mammography due to their low noise, high resolution performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Voltage-gated optics and plasmonics enabled by solid-state proton pumping

Devices with locally-addressable and dynamically tunable optical properties underpin emerging technologies such as high-resolution reflective displays and dynamic holography. The optical properties of metals such as Y and Mg can be reversibly switched by hydrogen loading, and hydrogen-switched mirrors and plasmonic devices have been realized, but challenges remain to achieve electrical, localized and reversible control. Here we report a nanoscale solid-state proton switch that allows for electrical control of optical properties through electrochemical hydrogen gating. We demonstrate the generality and versatility of this approach by realizing tunability of a range of device characteristics including transmittance, interference color, and plasmonic resonance. We further discover and exploit a giant modulation of the effective refractive index of the gate dielectric. The simple gate structure permits device thickness down to ~20 nanometers, which can enable device scaling into the deep subwavelength regime, and has potential applications in addressable plasmonic devices and reconfigurable metamaterials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-resolution CCD imagers using area-array CCD's for sensing spectral components of an optical line image

CCD imagers with a novel replicated-line-imager architecture are abutted to form an extended line sensor. The sensor is preceded by optics having a slit aperture and having an optical beam splitter or astigmatic lens for projecting multiple line images through an optical color-discriminating stripe filter to the CCD imagers. A very high resolution camera suitable for use in a satellite, for example, is thus provided. The replicated-line architecture of the imager comprises an area-array CCD, successive rows of which are illuminated by replications of the same line segment, as transmitted by respective color filter stripes. The charge packets formed by accumulation of photoresponsive charge in the area-array CCD are read out row by row. Each successive row of charge packets is then converted from parallel to serial format in a CCD line register and its amplitude sensed to generate a line of output signal.

Elabd, Hammam↗