Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMPLANTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

High-Dose-Rate Brachytherapy of a Single Implant With Two Fractions Combined With External Beam Radiotherapy for Hormone-Naive Prostate Cancer

Purpose: To evaluate the preliminary outcomes of high-dose-rate (HDR) brachytherapy of a single implant with two fractions and external beam radiotherapy (EBRT) for hormone-naive prostate cancer. Methods and Materials: Between March 2000 and Sept 2003, a total of 53 patients with tumor Stage T1c-T3b N0 M0 prostate cancer were treated with HDR brachytherapy boost doses (7.5 Gy/fraction) and 50-Gy EBRT during a 5.5-week period. Median follow-up was 61 months. Patients were divided into groups with localized (T1c-T2b) and advanced disease (T3a-T3b). We used the American Society for Therapeutic Radiology and Oncology (ASTRO) definition for biochemical failure. According to recommendations of the Radiation Therapy Oncology Group-ASTRO Phoenix Consensus Conference, biochemical failure-free control rates (BF-FCRs) at 3 years were investigated as 2 years short of the median follow-up. Results: Between April 2000 and Sept 2007, Common Terminology Criteria for Adverse Events Version 2.0 late Grade 2 genitourinary and gastrointestinal toxicity rates were 0% and 3.8%, respectively. Erectile preservation was 25% at 5 years. Overall survival was 88.1% and cause-specific survival was 100%. At 3 years, ASTRO BF-FCRs of the localized and advanced groups were 100% and 42%, respectively (p = 0.001). Conclusions: The HDR brachytherapy of a single implant with two fractions plus EBRT is effective in treating patients with localized hormone-naive prostate cancer, with the least genitourinary and gastrointestinal toxicities; however, longer median BF-FCR follow-up is required to assess these findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Dosimetric and Biologic Effective Dose Parameters for Prostate and Urethra Using {sup 131}Cs and {sup 125}I for Prostate Permanent Implant Brachytherapy

Purpose: To compare the urethral and prostate absolute and biologic effective doses (BEDs) for {sup 131}Cs and {sup 125}I prostate permanent implant brachytherapy (PPI). Methods and Materials: Eight previously implanted manually planned {sup 125}I PPI patients were replanned manually with {sup 131}Cs, and re-planned using Inverse Planning Simulated Annealing. {sup 131}Cs activity and the prescribed dose (115 Gy) were determined from that recommended by IsoRay. The BED was calculated for the prostate and urethra using an {alpha}/{beta} ratio of 2 and was also calculated for the prostate using an {alpha}/{beta} ratio of 6 and a urethral {alpha}/{beta} ratio of 2. The primary endpoints of this study were the prostate D{sub 90} BED (pD{sub 90}BED) and urethral D{sub 30} BED normalized to the maximal potential prostate D{sub 90} BED (nuD{sub 30}BED). Results: The manual plan comparison ({alpha}/{beta} = 2) yielded no significant difference in the prostate D{sub 90} BED (median, 192 Gy{sub 2} for both isotopes). No significant difference was observed for the nuD{sub 30}BED (median, 199 Gy{sub 2} and 202 Gy{sub 2} for {sup 125}I and {sup 131}Cs, respectively). For the inverse planning simulated annealing plan comparisons ({alpha}/{beta} 2), the prostate D{sub 90} BED was significantly lower with {sup 131}Cs than with {sup 125}I (median, 177 Gy{sub 2} vs. 187 Gy{sub 2}, respectively; p = 0.01). However, the nuD{sub 30}BED was significantly greater with {sup 131}Cs than with {sup 125}I (median, 192 Gy{sub 2} vs. 189 Gy{sub 2}, respectively; p = 0.01). Both the manual and the inverse planning simulated annealing plans resulted in a significantly lower prostate D{sub 90} BED (p = 0.01) and significantly greater nuD{sub 30}BED for {sup 131}Cs (p = 0.01), compared with {sup 125}I, when the prostate {alpha}/{beta} ratio was 6 and the urethral {alpha}/{beta} ratio was 2. Conclusion: This report highlights the controversy in comparing the dose to both the prostate and the organs at risk with different radionuclides.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tolerance and Acceptance Results of a Palladium-103 Permanent Breast Seed Implant Phase I/II Study

Purpose: To test, in a prospective Phase I/II trial, a partial breast irradiation technique using a {sup 103}Pd permanent breast seed implant (PBSI) realized in a single 1-h procedure under sedation and local freezing. Methods and Materials: Eligible patients had infiltrating ductal carcinoma {<=}3 cm in diameter, surgical margin {>=}2 mm, no extensive intraductal component, no lymphovascular invasion, and negative lymph nodes. Patients received a permanent seed implant, and a minimal peripheral dose of 90 Gy was prescribed to the clinical target volume, with a margin of 1.5 cm. Results: From May 2004 to April 2007, 67 patients received the PBSI treatment. The procedure was well tolerated, with 17% of patients having significant pain after the procedure. Only 1 patient (1.5%) had an acute skin reaction (Grade 3 according to the National Cancer Institute Common Toxicity Criteria). The rates of acute moist desquamation, erythema, and indurations were 10.4%, 42%, and 27%, respectively. At 1 year the rate of Grade 1 telangiectasia was 14%. The rate of skin reaction decreased from 65% to 28% when skin received less than the 85% isodose. According to a Radiation Therapy Oncology Group questionnaire, 80-90% of patients were very satisfied with their treatment, and the remainder were satisfied. One patient (1.5%) developed an abscess, which resolved after the use of antibiotics. There was no recurrence after a median follow-up of 32 months (range, 11-49 months). Conclusions: The feasibility, safety, and tolerability of PBSI compares favorably with that of external beam and other partial breast irradiation techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Day-to-Day Reproducibility of Prostate Intrafraction Motion Assessed by Multiple kV and MV Imaging of Implanted Markers During Treatment

Purpose: When one is performing online setup correction for prostate positioning displacements prior to daily dose delivery, intrafraction motion can become a limiting factor to prostate targeting accuracy. The aim of this study was to quantify and characterize prostate intrafraction motion assessed by multiple kilovoltage (kV) and megavoltage (MV) imaging of implanted markers during treatment in a large patient group. Methods and Materials: Intrafraction motion in the sagittal plane was studied by retrospective analysis of displacements of implanted gold markers on (nearly) lateral kV and MV images obtained at various time points during the treatment fractions (mean, 27 per patient) in 108 consecutive patients. The effective prostate motion in a fraction was defined as the time-weighted mean displacement. Results: Prostate displacements in the sagittal plane increased during the fraction (mean, 0.2 {+-} 0.2 mm/min). Forty percent of patients had a systematic (i.e., appearing in all fractions) effective displacement in the sagittal plane greater than 2 mm. Observed effective population mean-of-means ({mu}eff) +/- systematic ({Sigma}eff) intrafraction motion ({mu}{sub eff} {+-} {Sigma}{sub eff}) was 0.9 {+-} 1.1 mm and 0.6 {+-} 1.0 mm for the anterior-posterior and superior inferior directions, respectively. Corresponding random motion ({sigma}{sub eff}) was 1.2 mm and 1.1 mm. Mean effective prostate motion in the first 5 fractions was predictive for mean effective displacement in the remaining fractions (p < 0.001). Conclusion: For a large subgroup of patients, the systematic component of intrafraction prostate motion was substantial. Intrafraction motion correction prior to each beam delivery or offline corrections could likely be beneficial for the subgroup of patients with significant motion. The systematic component is well predicted by measurements in the initial fractions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Report on the Clinical Outcomes of Permanent Breast Seed Implant for Early-Stage Breast Cancers

Purpose: Permanent breast seed implant is an accelerated partial breast irradiation technique realizing the insertion of {sup 103}Pd seeds in the seroma after lumpectomy. We report the 5-year efficacy and tolerance for a cohort, pooling patients from 3 clinical trials. Methods and Materials: The trials accrued postmenopausal patients with infiltrating ductal carcinoma or ductal carcinoma in situ ≤3 cm and clear surgical margins, who were node negative, and had a planning target volume <120 cm{sup 3}. The outcomes included overall and disease-free survival and local and contralateral recurrence at 5 years. The true local recurrence rate was compared using 2-tailed paired t tests for estimates calculated using the Tufts University ipsilateral breast tumor recurrence and Memorial Sloan Kettering ductal carcinoma in situ nomograms. Results: The cohort included 134 patients, and the observed local recurrence rate at a median follow-up period of 63 months was 1.2% ± 1.2%, similar to the estimate for whole breast irradiation (P=.23), significantly better than for surgery alone (relative risk 0.27; P<.001), and significantly lower than contralateral recurrence (relative risk 0.33; P<.001). The 5-year overall survival rate was 97.4% ± 1.9%, and the disease-free survival rate was 96.4% ± 2.1%. At 2 months, 42% of the patients had erythema, 20% induration, and 16% moist desquamation. The rate of mainly grade 1 telangiectasia was 22.4% at 2 years and 24% at 5 years. The rate of asymptomatic induration was 23% at 2 years and 40% at 5 years. Conclusions: The 5-year data suggest that permanent breast seed implantation is a safe accelerated partial breast irradiation option after lumpectomy for early-stage breast cancer with a tolerance profile similar to that of whole breast irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation induced hardening of beryllium during low temperature He implantation

The effect of ion irradiation on evolution of microstructure and hardening of beryllium with different impurity levels was investigated using TEM and nanoindentation. High purity S-65 grade and less-pure S-200-F grade were implanted by helium ions at temperatures of 50°C and 200°C. 11 different energies were used, so as to create a quasi-homogeneous 3 µm irradiated layer with average radiation damage of 0.1 dpa and average He content of 2000 appm.Nanoindentation experiments demonstrated that before irradiation, the S-200-F and S-65 grades have an average hardness of 3.7$\pm$0.8 GPa and 3.4$\pm$0.8 GPa correspondently. After implantation the hardness of both grades increased by about 60% for the 200°C irradiation and 100% for the 50°C irradiation. The crystallographic analysis of indented grains demonstrated that in the as-received materials the hardness is about 2.5 times higher when the indentation direction is close to the [0001] c-axis of beryllium compared to indentation perpendicular to [0001]. Hardness anisotropy significantly decreased after irradiation: the “soft orientation” was most sensitive to irradiation-induced hardening, with hardness increasing by about 140% after irradiation at 50°C and 100% after irradiation at 200°C, compared to about 15 - 20% for the “hard” orientation at both irradiation temperatures. The higher purity grade had smaller increase of the “soft orientation” hardness: 2.5$\pm$0.3 GPa for the S-65 and 2.9$\pm$0.2 GPa for the S-200-F.At both temperatures in both grades, under TEM investigation the radiation damage appears as “black dots” which are likely to be small dislocation loops with the number density of ~ 10 22 m -3 . No bubbles were observed by TEM inside grains and at grain boundaries. Analysis of the possible hardening contribution demonstrated that the observed “black dots” could be responsible for up to half of the measured hardening, while the rest of the hardening should originate from helium bubbles with the size below the TEM resolution (at or below 1.5 nm).

36 MATERIALS SCIENCE↗

Helium-implantation-induced lattice strains and defects in tungsten probed by X-ray micro-diffraction

Tungsten is the main candidate material for plasma-facing armour components in future fusion reactors. Bombardment with energetic fusion neutrons causes collision cascade damage and defect formation. Interaction of defects with helium, produced by transmutation and injected from the plasma, modifies defect retention and behaviour. Here we investigate the residual lattice strains caused by different doses of helium-ion-implantation into tungsten and tungsten-rhenium alloys. Energy and depth-resolved synchrotron X-ray micro-diffraction uniquely permits the measurement of lattice strain with sub-micron 3D spatial resolution and ~10 -4 strain sensitivity. Increase of helium dose from 300 appm to 3000 appm increases volumetric strain by only ~2.4 times, indicating that defect retention per injected helium is ~3 times higher at low helium doses. This suggests defect retention is not a simple function of implanted helium dose, but strongly depends on material composition and presence of impurities. Conversely, analysis of W-1 wt% Re alloy samples and of different crystal orientations shows that both the presence of rhenium, and crystal orientation, have a comparatively small effect on defect retention. These insights are key for the design of armour components in future reactors where it will be essential to account for irradiation-induced dimensional change when predicting component lifetime and performance.

36 MATERIALS SCIENCE↗

Effect of brachytherapy technique and patient characteristics on cervical cancer implant dosimetry

Our purpose was to evaluate the relationship between brachytherapy technique and patient characteristics on dose to organs-at-risk (OARs) in patients undergoing high dose rate (HDR) brachytherapy for cervical cancer. From 1998 to 2008, 31 patients with cervical cancer with full dosimetric data were identified who received definitive external-beam radiation and HDR brachytherapy with tandem and ovoid applicators. Doses were recorded at point A, the International Commission on Radiation Units and Measurements (ICRU)-38 rectal point, the ICRU-38 bladder point, the vaginal surface, and the pelvic sidewall. Generalized estimating equations were used to determine the significance of changes in OAR to point A dose ratios with differences in brachytherapy technique or patient characteristics. Patients underwent a median of 5 brachytherapy procedures (range, 3 to 5), with a total of 179 procedures for 31 patients. For all brachytherapy treatments, the average ratios between the doses for the rectal, bladder, vaginal surface, and pelvic sidewall reference points to those at point A were 0.49, 0.59, 1.15, and 0.17, respectively. In general, decreased OAR dose was associated with a lower stage, younger age, increased ovoid size, increased tandem length, and earlier implant number. Increased tandem curvature significantly increased bladder dose and decreased rectal dose. Intravenous anesthesia usage was not correlated with improved dosimetry. This study allowed identification of patient and procedure characteristics influencing OAR dosing. Although the advent of 3-dimensional (3D) image-guided brachytherapy will bring new advances in treatment optimization, the actual technique involved at the time of the brachytherapy implant procedure will remain important.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric and radiobiological comparison of volumetric modulated arc therapy, high-dose rate brachytherapy, and low-dose rate permanent seeds implant for localized prostate cancer

To investigate the dosimetric and radiobiological differences among volumetric modulated arc therapy (VMAT), high-dose rate (HDR) brachytherapy, and low-dose rate (LDR) permanent seeds implant for localized prostate cancer. A total of 10 patients with localized prostate cancer were selected for this study. VMAT, HDR brachytherapy, and LDR permanent seeds implant plans were created for each patient. For VMAT, planning target volume (PTV) was defined as the clinical target volume plus a margin of 5 mm. Rectum, bladder, urethra, and femoral heads were considered as organs at risk. A 78 Gy in 39 fractions were prescribed for PTV. For HDR and LDR plans, the dose prescription was D{sub 90} of 34 Gy in 8.5 Gy per fraction, and 145 Gy to clinical target volume, respectively. The dose and dose volume parameters were evaluated for target, organs at risk, and normal tissue. Physical dose was converted to dose based on 2-Gy fractions (equivalent dose in 2 Gy per fraction, EQD{sub 2}) for comparison of 3 techniques. HDR and LDR significantly reduced the dose to rectum and bladder compared with VMAT. The D{sub mean} (EQD{sub 2}) of rectum decreased 22.36 Gy in HDR and 17.01 Gy in LDR from 30.24 Gy in VMAT, respectively. The D{sub mean} (EQD{sub 2}) of bladder decreased 6.91 Gy in HDR and 2.53 Gy in LDR from 13.46 Gy in VMAT. For the femoral heads and normal tissue, the mean doses were also significantly reduced in both HDR and LDR compared with VMAT. For the urethra, the mean dose (EQD{sub 2}) was 80.26, 70.23, and 104.91 Gy in VMAT, HDR, and LDR brachytherapy, respectively. For localized prostate cancer, both HDR and LDR brachytherapy were clearly superior in the sparing of rectum, bladder, femoral heads, and normal tissue compared with VMAT. HDR provided the advantage in sparing of urethra compared with VMAT and LDR.

61 RADIATION PROTECTION AND DOSIMETRY↗

Segmented YSO scintillation detectors as a new β -implant detection tool for decay spectroscopy in fragmentation facilities

A newly developed segmented YSO scintillator detector was implemented for the first time at the RI-beam Factory at RIKEN Nishina Center as an implantation-decay counter. The results from the experiment demonstrate that the detector is a viable alternative to conventional silicon-strip detectors with its good timing resolution and high detection efficiency for β particles. A Position-Sensitive Photo-Multiplier Tube (PSPMT) is coupled with a 48 × 48 segmented YSO crystal. To demonstrate its capabilities, a known short-lived isomer in 76 Ni and the β decay of 74 Co were measured by implanting those ions into the YSO detector. The half-lives and γ-rays observed in this work are consistent with the known values. The β -ray detection efficiency is more than 80 % for the decay of 74 Co.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A fitting algorithm for optimizing ion implantation energies and fluences

In this work we describe a method to automatically generate an ion implantation recipe, a set of energies and fluences, to produce a desired defect density profile in a solid using the fewest required energies. We simulate defect density profiles for a range of ion energies, fit them with an appropriate function, and interpolate to yield defect density profiles at arbitrary ion energies. Given Ν energies, we then optimize a set of Ν energy-fluence pairs to match a given target defect density profile. Finally, we find the minimum Ν such that the error between the target defect density profile and the defect density profile generated by the Ν energy-fluence pairs is less than a given threshold. Inspired by quantum sensing applications with nitrogen-vacancy centers in diamond, we apply our technique to calculate optimal ion implantation recipes to create uniform-density 1 μm surface layers of 15 N or vacancies (using 4 He).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Controllable Formation of Threefold-Coordinated Oxygen in Graphene by Low-Energy Ion Implantation

The atomically precise engineering of impurities in graphene and the understanding of their structural and carrier-dependent electronic properties at the nanoscale are crucial for advancing graphene-based nanoelectronics, catalysis, and energy technologies. Here, we demonstrate controllable incorporation of the elusive 3-fold-coordinated O substitutions into graphene using low-energy O + ion implantation under ultrahigh-vacuum conditions. By combining high-resolution scanning tunneling microscopy and spectroscopy (STM/S), bond-resolved noncontact atomic force microscopy techniques, and density functional theory (DFT) calculations, we resolve both the structural and electronic properties of the O-related defects. The STM/S measurements, corroborated by DFT calculations, uncover a characteristic impurity state that is energetically pinned to the Dirac point across different charge-carrier doping regimes. Molecular dynamics simulations further reveal the distribution of implantation-induced configurations and identify the formation of 3-fold-coordinated O dopants. Furthermore, this work provides a viable route to incorporate 3-fold-coordinated O dopants and opens new opportunities for controlled defect engineering in graphene.

3-fold-coordinated oxygen↗

Ion sources for energy extremes of ion implantation (invited)

For the past four years a joint research and development effort designed to develop steady state, intense ion sources has been in progress with the ultimate goal to develop ion sources and techniques that meet the two energy extreme range needs of meV and hundreads of eV ion implanters. This endeavor has already resulted in record steady state output currents of high charge state of antimony and phosphorus ions: P{sup 2+} [8.6 pmA (particle milliampere)], P{sup 3+} (1.9 pmA), and P{sup 4+} (0.12 pmA) and 16.2, 7.6, 3.3, and 2.2 pmA of Sb{sup 3+}Sb{sup 4+}, Sb{sup 5+}, and Sb{sup 6+} respectively. For low energy ion implantation, our efforts involve molecular ions and a novel plasmaless/gasless deceleration method. To date, 1 emA (electrical milliampere) of positive decaborane ions was extracted at 10 keV and smaller currents of negative decaborane ions were also extracted. Additionally, boron current fraction of over 70% was extracted from a Bernas-Calutron ion source, which represents a factor of 3.5 improvement over currently employed ion sources.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hydrophilic property by contact angle change of ion implanted polycarbonate

In this study, ion implantation was performed onto a polymer, polycarbonate (PC), in order to investigate surface hydrophilic property through contact angle measurement. PC was irradiated with N, Ar, and Xe ions at the irradiation energy of 20-50 keV and the dose range of 5x10{sup 15}, 1x10{sup 16}, 7x10{sup 16} ions/cm{sup 2}. The contact angle of water was estimated by means of the sessile drop method and was reduced with increasing fluence and ion mass but increased with increasing implanted energy. The changes of chemical and structural properties are discussed in view of Furier transform infrared and x-ray photoelectron spectroscopy, which shows increasing C-O bonding and C-C bonding. The surface roughness examined by atomic force microscopy measurement changed smoothly from 3.59 to 2.22 A as the fluence increased. It is concluded that the change in wettability may be caused by surface carbonization and oxidation as well as surface roughness.

36 MATERIALS SCIENCE↗

Strain effects and microstructural evolution in Ge-Si system materials prepared by ion implantation and by ultrahigh vacuum chemical vapor deposition

Appropriately utilizing some microstructures may be very helpful to acquire desirable Ge-Si system materials. In this work, the Ge-Si system materials have been prepared either by ion implantation or ultrahigh vacuum chemical vapor deposition (UHVCVD). The interesting microstructures including half-loop dislocations, SiGe nanoclusters, and dislocation dipoles have been found in these two kinds of Ge-Si system materials. It is demonstrated that the evident surface strain state and adequate surface layer quality have been realized by employing these microstructures. Compared with the dipole dislocations in the Ge-Si systems deposited by UHVCVD on the compliant silicon on insulator, the half-loop dislocations and the SiGe nanoclusters induced by Ge ion implantation and subsequent annealing can relax the SiGe layer more effectively and lead to relatively large strain in the surface silicon. It may provide some new approaches to the control of misfit strains for fabricating desirable Ge-Si system materials.

36 MATERIALS SCIENCE↗

Evolution mechanism of nanocrystalline tungsten-carbon and effects on tungsten implanted amorphous hydrogenated carbon

Tungsten doped amorphous carbon films are prepared on silicon (100) by postimplantation of tungsten ions into pure amorphous hydrogenated carbon using the plasma immersion ion implantation technique. The peak concentration of tungsten reaches 27 at. % and W-C nanocrystallites with largest diameters of {approx}5 nm are formed in the near surface region. Both the quantity and size of these nanocrystallites are observed to undergo unique transformation with increasing depths, enabling gradual release of the compressive stress and subsequently leading to better adhesion between the film and substrate. The film structures are evaluated by x-ray photoelectron spectroscopy and glancing angle x-ray diffraction, and high-resolution transmission microscopy is employed to investigate the structural transformation. The mechanical properties of the films including adhesion strength and hardness are determined by nanoindentation and nanoscratch tests. The formation of the nanocrystalline structures can be explained by ion implantation induced damage, chemical effects, and thermodynamics.

36 MATERIALS SCIENCE↗

Fourth-generation plasma immersion ion implantation and deposition facility for hybrid surface modification layer fabrication

The fourth-generation plasma immersion ion implantation and deposition (PIIID) facility for hybrid and batch treatment was built in our laboratory recently. Comparing with our previous PIIID facilities, several novel designs are utilized. Two multicathode pulsed cathodic arc plasma sources are fixed on the chamber wall symmetrically, which can increase the steady working time from 6 h (the single cathode source in our previous facilities) to about 18 h. Meanwhile, the inner diameter of the pulsed cathodic arc plasma source is increased from the previous 80 to 209 mm, thus, large area metal plasma can be obtained by the source. Instead of the simple sample holder in our previous facility, a complex revolution-rotation sample holder composed of 24 shafts, which can rotate around its axis and adjust its position through revolving around the center axis of the vacuum chamber, is fixed in the center of the vacuum chamber. In addition, one magnetron sputtering source is set on the chamber wall instead of the top cover in the previous facility. Because of the above characteristic, the PIIID hybrid process involving ion implantation, vacuum arc, and magnetron sputtering deposition can be acquired without breaking vacuum. In addition, the PIIID batch treatment of cylinderlike components can be finished by installing these components on the rotating shafts on the sample holder.

36 MATERIALS SCIENCE↗

Electron-phonon coupling in ion implanted cobalt silicide below 1 K

Cobalt silicide is a popular compound in semiconductor technology for fabricating resistive microcomponents and metallization. In advanced silicon-based cryogenic devices, such as radiation detectors and coolers, the electronic energy distribution is fundamentally determined by the thermal state of the mesoscopic system. In this work, electron-phonon heat transport at cryogenic temperatures was studied in a silicide formed by high fluence ion implantation of Co into Si. A heat flow between electrons and phonons was found to be proportional to (T{sub el}{sup p}-T{sub ph}{sup p}) with p=3.3. The electron-phonon coupling constant that characterizes the thermal resistance between electrons and phonons was derived from the power dependence of the electron temperature measured well bellow 1 K. The constant was found to be temperature dependent in the implanted cobalt silicide.

36 MATERIALS SCIENCE↗