Search NASA⌕ Search

SEARCH · Search NASA

Results for “IRRADIATION DEVICES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Temperature coefficients and radiation induced DLTS spectra of MOCVD grown n(+)p InP solar cells

The effects of temperature and radiation on n(+)p InP solar cells and mesa diodes grown by metallorganic chemical vapor deposition (MOCVD) were studied. It was shown that MOCVD is capable of consistently producing good quality InP solar cells with Eff greater than 19 percent which display excellent radiation resistance due to minority carrier injection and thermal annealing. It was also shown that universal predictions of InP device performance based on measurements of a small group of test samples can be expected to be quite accurate, and that the degradation of an InP device due to any incident particle spectrum should be predictable from a measurement following a single low energy proton irradiation.

Walters, Robert J.↗

Applications of diamond films and related materials; Proceedings of the 1st International Conference, Auburn, AL, Aug. 17-22, 1991

The present conference discusses the nucleation and growth of diamond from hydrocarbons, the cutting tool performance of CVD thick-film diamond, the characterization of CVD diamond grinding powder, industrial applications of crystalline diamond-coated tools, standardized SEM tribometry of diamond-coated substrates, residual stress in CVD diamond films, the optical properties of CVD diamond films, polycrystalline diamond films for optical applications, and diamond growth on ferrous metals. Also discussed are ion beam-irradiation smoothing of diamond films, electronic circuits on diamond substrates, diamond-laminated surfaces for evaporative spray cooling, electron devices based on the unique properties of diamond, diamond cold cathodes, thin-film diamond microstructure applications, Schottky diodes from flame-grown diamond, diamond films for thermionic applications, methods of diamond nucleation and selective deposition, high-rate/large-area diamond film production, halogen-assisted diamond growth, the economics of diamond technology, and the optical and mechanical properties of diamondlike films.

Tzeng, Yonhua↗

InGaAs/InP solar cells for space application

The effects of irradiation of In(0.53)Ga(0.47)As/InP (InGaAs/InP) solar cells illuminated through a transparent InP substrate with 1 MeV electrons were measured. These solar cells were developed for bottom cells in tandem solar photovoltaic cell structures. Some InGaAs/InP heterostructures with four layers were grown by liquid phase epitaxy. The structure of the solar cells allowed lightly doped materials in n and p photoactive layers to be used. The base dopant levels ranged from 1.10(exp 17) to 5.10(exp 17) cm(exp -3). The open circuit voltage and the short circuit current were moderately degraded after irradiation with 10(exp 16) cm(exp-2) 1 MeV electrons. This behavior is explained in terms of the device structure and the n and p layer thicknesses.

Karlina, L. B.↗

Optically-Switched Resonant Tunneling Diodes for Space-Based Optical Communication Applications

We are developing a new type of digital photo-receiver that has the potential to perform high speed optical-to-electronic conversion with a factor of 10 reduction in component count and power dissipation. In this paper, we describe the room-temperature photo-induced switching of this InP-based device which consists of an InGaAs/AlAs resonant tunneling diode integrated with an InGaAs absorber layer. When illuminated at an irradiance of greater than 5 Wcm(exp -2) using 1.3 micromillimeter radiation, the resonant tunneling diode switches from a high-conductance to a low-conductance electrical state and exhibits a voltage swing of up to 800 mV.

Moise, T. S.↗

High Precision Piezoelectric Linear Motors for Operations at Cryogenic Temperatures and Vacuum

The Jet Propulsion Laboratory evaluated the use of an electromechanical device for optically positioning a mirror system during the pre-project phase of the Pluto-Fast-Flyby (PFF) mission. The device under consideration was a piezoelectric driven linear motor functionally dependent upon a time varying electric field which induces displacements ranging from submicrons to millimeters with positioning accuracy within nanometers. Using a control package, the mirror system provides image motion compensation and mosaicking capabilities. While this device offers unique advantages, there were concerns pertaining to its operational capabilities for the PFF mission. The issues include irradiation effects and thermal concerns. A literature study indicated that irradiation effects will not significantly impact the linear motor's operational characteristics. On the other hand, thermal concerns necessitated an in depth study.

piezoelectric motors↗

Image Distortions on a Plastic Interstitial Computed Tomography/Magnetic Resonance Brachytherapy Applicator at 3 Tesla Magnetic Resonance Imaging and Their Dosimetric Impact

Purpose: To quantify magnetic resonance imaging (MRI) distortions on a plastic intracavitary/interstitial applicator with plastic needles at a field strength of 3 T and to determine the dosimetric impact, using patient data. Methods and Materials: For 11 cervical cancer patients, our clinical MRI protocol was extended with 3 scans. From the first scan, a multi-echo acquisition, a map of the magnetic field (B{sub 0}) was calculated and used to quantify the field inhomogeneity. The expected displacements of the applicator were quantified for the clinical sequence using the measured field inhomogeneity and the clinical sequence's bandwidth. The second and third scan were our routine clinical sequence (duration: <5 minutes each), acquired consecutively using opposing readout directions. The displacement of the applicator between these scans is approximately twice the displacement due to B{sub 0} inhomogeneity. The impact of the displacement on the dose was determined by reconstructing the applicator on both scans. The applicator was then shifted and rotated the same distance as the observed displacement to create a worst-case scenario (ie, twice the actual displacement due to B{sub 0} inhomogeneity). Next, the dose to 98%/90% (D{sub 98}/D{sub 90}) of the clinical target volume at high risk, as well as the dose to the most irradiated 2 cm{sup 3} for bladder and rectum, were calculated for the original plan as well as the shifted plan. Results: For a volume of interest containing the intrauterine device and the ovoids the 95th percentile of the absolute displacement ranged between 0.2 and 0.75 mm, over all patients. For all patients, the difference in D{sub 98}/D{sub 90} in the opposing readout scans with the original plan was at most 4.7%/4.3%. For the dose to the most irradiated 2 cm{sup 3} of bladder/rectum, the difference was at most 6.0%/6.3%. Conclusions: The dosimetric impact of distortions on this plastic applicator with plastic needles is limited. Applicator reconstruction for brachytherapy planning purposes is feasible at 3 T MRI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Conceptual Design and Analysis of In-Vessel Components for the Materials Plasma Exposure eXperiment (MPEX)

The materials plasma exposure experiment (MPEX) is a linear plasma divertor simulator currently undergoing conceptual design. The facility will expose material samples to steady-state plasma fluxes to examine plasma–material interactions (PMIs) that are expected in the next generation of fusion devices. The plasmas will be generated by a helicon source, with electron and ion heating sources of up to 800 kW possible. The peak heat fluxes of the target are expected to be up to 10 MW/m 2 . The facility will be capable of handling low-activation neutron-irradiated samples in order to examine the multivariate effects of neutron damage and plasma fluence. Neutron-irradiated samples are planned to be roughly of 10-mm diameter; however, plasma-facing components up to 60×600 mm can be accommodated. The steady-state nature of the device will require the magnetic confinement of the plasma to be achieved with superconducting magnets, with a maximum on-axis field of 2.5 T. In addition, since MPEX will be a steady-state device, in-vessel components need to be water cooled. The primary in-vessel components will be the target, the dump plate, the limiter, the skimmers, and the microwave absorber. The conceptual design of these components is presented here, including analyses that confirm that the designs are adequate to meet the requirements of MPEX operation.

Lumsdaine, Arnold↗

Modeling diurnal and annual ethylene generation from solar-driven electrochemical CO 2 reduction devices

Integrated solar fuels devices for CO 2 reduction (CO 2 R) are a promising technology class towards reducing carbon emissions. Designing integrated CO 2 R solar fuels devices requires careful co-design of electrochemical and photovoltaic components as well as consideration of the diurnal and seasonal effects of solar irradiance, temperature, and other meteorological factors expected for ‘on-sun’ deployment. Using a photovoltaic-electrochemical (PV-EC) platform, we developed a temperature and potential-dependent diurnal and annual model using experimentally-determined CO 2 R performance of Cu-based electrocatalysts, local meteorological data from the National Solar Radiation Database (NSRD), and modeled performance of commercial c-Si PVs. Here we simulated gaseous diurnal product outputs with and without the effects of ambient temperature. From these outputs, we observed seasonal variation in gaseous product generation, with up to two-fold increases in ethylene productivity between the Winter and Summer, analyzed the consequences of dynamic cloud coverage, and identified periods where device cooling/heating mechanisms could be implemented to maximize ethylene generation. Finally, we modeled the annual ethylene generation for a scaled 1 MW solar farm at three different locations (Beijing, CN; Sydney, AUS; Barstow, CA) to determine the consequences of local meteorological climates on PV-EC CO 2 R product output, recording a maximum ethylene output of 18.5 tonne per year at Barstow. Overall, this model presents a critical tool for streamlining the translation of experimental solar-driven electrochemical research to real-world implementation.

14 SOLAR ENERGY↗

Report on the Second MPEX User Research Forum

The Material Plasma Exposure eXperiment (MPEX) User Research Forum (MURF), a 2 day workshop, was held virtually on September 13–14, 2021, to seek community input for MPEX, a new high-power linear plasma device that is currently being built at Oak Ridge National Laboratory (ORNL). This was the second MURF workshop. The first MURF workshop was held in October 2019 in La Jolla, California, and focused exclusively on the definition of the surface analysis station for MPEX. MPEX is designed to address crucial R&D gaps in plasma material interactions (PMI) for future fusion reactors. The MPEX plasma source and heating systems will allow plasma exposures of plasma-facing materials and components to prototype fusion reactor divertor plasma conditions. The MPEX design accommodates the introduction of previously neutron-irradiated materials for fusion reactor-relevant plasma exposures. This capability will be unique worldwide. The US fusion program has advocated for such a device in numerous community reports in recent years, and now ORNL is building this new device. MPEX is a Major Item of Equipment project executed by the US Department of Energy’s Office of Science Fusion Energy Sciences.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling Diurnal and Annual Ethylene Generation from Solar-Driven Electrochemical CO 2 Reduction Devices

Integrated solar fuels devices for CO 2 reduction (CO 2 R) are a promising technology class towards achieving net-negative carbon emissions. Designing integrated CO 2 R solar fuels devices requires careful co-design of electrochemical and photovoltaic components as well as consideration of the diurnal and seasonal effects of solar irradiance, temperature, and other meteorological factors expected for ‘on-sun’ deployment. Here, using a photovoltaic-electrochemical (PV-EC) platform, we developed a temperature and potential-dependent diurnal and annual model using experimental CO 2 R performance of Cu-based electrocatalysts, local meteorological data from the National Solar Radiation Database (NSRD), and modeled performance of commercial c-Si PVs. We simulated diurnal product outputs with and without the effects of ambient temperature to determine gaseous product temperature sensitivity. From these outputs, we observed seasonal variation in gaseous product generation, with up to two-fold increases in ethylene productivity between the Winter and Summer, analyzed the consequences of dynamic cloud coverage, and identified periods where device cooling/heating mechanisms could be implemented to maximize ethylene generation. Finally, we modeled the annual ethylene generation for a scaled 1 MW solar farm at three different locations (Beijing, CN; Sydney, AUS; Barstow, CA) to determine the consequences of local meteorological climates on PV-EC CO 2 R product output, recording a maximum ethylene output of 18.5 tonne/yr at Barstow. Overall, this model presents a critical tool for streamlining the translation of experimental solar-driven electrochemical research to real-world implementation.

Yap, Kyra M. K.↗

First in-core simultaneous measurements of nuclear heating and thermal neutron flux obtained with the innovative mobile calorimeter CALMOS inside the OSIRIS reactor

Nuclear heating inside a MTR reactor has to be known in order to design and to run irradiation experiments which have to fulfill target temperature constraints. This measurement is usually carried out by calorimetry. The innovative calorimetric system, CALMOS, has been studied and built in 2011 for the 70 MWth OSIRIS reactor operated by CEA. Thanks to a new type of calorimetric probe, associated to a specific displacement system, it provides measurements along the fissile height and above the core. This development required preliminary modelling and irradiation of mock-ups of the calorimetric probe in the ex-core area, where nuclear heating rate does not exceed 2 W.g{sup -1}. The calorimeter working modes, the different measurement procedures allowed with such a new probe, the main modeling and experimental results and expected advantages of this new technique have been already presented. However, these first in-core measurements were not performed beyond 6 W.g{sup -1}, due to an inside temperature limitation imposed by a safety authority requirement. In this paper, we present the first in-core simultaneous measurements of nuclear heating and conventional thermal neutron flux obtained by the CALMOS device at the 70 MW nominal reactor power. For the first time, this experimental system was operated in nominal in-core conditions, with nominal neutron flux up to 2.7 10{sup 14} n.cm{sup -2}.s{sup -1} and nuclear heating up to 12 W.g{sup -1}. A comprehensive measurement campaign carried out from 2013 to 2015 inside all accessible irradiation locations of the core, allowed to qualify definitively this new device, not only in terms of measurement ability but also in terms of reliability. After a brief reminder of the calorimetric cell configuration and displacement system specificities, first nuclear heating distributions at nominal power are presented and discussed. In order to reinforce the heating evaluation, a systematic comparison is made between results obtained by different methods, the probe calibration coefficient and the zero method. Thermal neutron flux evaluation from the SPND signal processing required a specific TRIPOLI-4 Monte Carlo calculation which has been performed with the precise CALMOS cell geometry. In addition, the Finite Element model for temperatures map prediction inside the calorimetric cell has been upgraded with the recent experimental data obtained up to 12 W.g{sup -1}. The Kc coefficient, taking into account nonlinearities with regard to the calibration, has been reevaluated so as to make relevant measurements up to the nominal reactor power. Finally, the experience feedback acquired until now with this first CALMOS version led us to improvement perspectives. A second device is currently under manufacturing and main technical options chosen for this second version are presented. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Postfabrication Phase Error Correction of Silicon Photonic Circuits by Single Femtosecond Laser Pulses

Phase errors caused by fabrication variations in silicon photonic integrated circuits are an important problem, which negatively impacts device yield and performance. This study reports our recent progress in the development of a method for permanent, postfabrication phase error correction of silicon photonic circuits based on femtosecond laser irradiation. Using beam shaping technique, we achieve a 14-fold enhancement in the phase tuning resolution of the method with a Gaussian-shaped beam compared to a top-hat beam. The large improvement in the tuning resolution makes the femtosecond laser method potentially useful for very fine phase trimming of silicon photonic circuits. Finally, we also show that femtosecond laser pulses can directly modify silicon photonic devices through a SiO 2 cladding layer, making it the only permanent post-fabrication method that can tune silicon photonic circuits protected by an oxide cladding.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proton Irradiation of the 16GB Intel Optane SSD

The purpose of this test is to assess the single event effects (SEE) and radiation susceptibility of the Intel Optane Memory device (SSD) containing the 3D Xpoint phase change memory (PCM) technology. This test is supported by the NASA Electronics Parts and Packaging Program (NEPP).

Single-Event Effects (SEE)↗

Femtosecond laser three-dimensional micro- and nanofabrication

The rapid development of the femtosecond laser has revolutionized materials processing due to its unique characteristics of ultrashort pulse width and extremely high peak intensity. The short pulse width suppresses the formation of a heat-affected zone, which is vital for ultrahigh precision fabrication, whereas the high peak intensity allows nonlinear interactions such as multiphoton absorption and tunneling ionization to be induced in transparent materials, which provides versatility in terms of the materials that can be processed. More interestingly, irradiation with tightly focused femtosecond laser pulses inside transparent materials makes three-dimensional (3D) micro- and nanofabrication available due to efficient confinement of the nonlinear interactions within the focal volume. Additive manufacturing (stereolithography) based on multiphoton absorption (two-photon polymerization) enables the fabrication of 3D polymer micro- and nanostructures for photonic devices, micro- and nanomachines, and microfluidic devices, and has applications for biomedical and tissue engineering. Subtractive manufacturing based on internal modification and fabrication can realize the direct fabrication of 3D microfluidics, micromechanics, microelectronics, and photonic microcomponents in glass. These microcomponents can be easily integrated in a single glass microchip by a simple procedure using a femtosecond laser to realize more functional microdevices, such as optofluidics and integrated photonic microdevices. The highly localized multiphoton absorption of a tightly focused femtosecond laser in glass can also induce strong absorption only at the interface of two closely stacked glass substrates. Consequently, glass bonding can be performed based on fusion welding with femtosecond laser irradiation, which provides the potential for applications in electronics, optics, microelectromechanical systems, medical devices, microfluidic devices, and small satellites. This review paper describes the concepts and principles of femtosecond laser 3D micro- and nanofabrication and presents a comprehensive review on the state-of-the-art, applications, and the future prospects of this technology.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Surface chemistry of neutron irradiated tungsten in a high-temperature multi-material environment

Deuterium retention was measured on neutron irradiated tungsten samples where one side of the samples had a visually clean metallic luster and the opposite side appeared to have a reacted surface film. Deuterium plasma exposure and subsequent thermal desorption from the reacted surface side produced spectra with larger total deuterium desorption at lower temperatures than from the clean surface side. For neutron irradiation, these W disk samples were installed in an irradiation capsule in such a way that one side of W sample was in contact with the surface of another W sample, and the opposite side was in contact with a SiC temperature monitor. The composition of the reacted surface was investigated using X-ray photoelectron spectroscopy and showed that SiC had interdiffused into the W samples. Neutron enhanced diffusion likely contributed to this as SiC and W are stable at temperatures exceeding the irradiation temperature. Results highlight the need to consider the surface chemistry of samples in drawing conclusions on hydrogen isotope retention of W materials and also illustrate the complexity of multi-material nuclear environments expected in fusion devices.

36 MATERIALS SCIENCE↗

Scintillator based nuclear photovoltaic batteries for power generation at microwatts level

A nuclear photovoltaic battery uses scintillator to convert radiation into visible light, which is then collected by a photovoltaic (PV) cell to generate electricity. If the radiation is gamma-rays emitted from external sources, the battery may also be referred as gammavoltaic battery. In this study, a polycrystalline CdTe solar cell was optically coupled with a 2.0 cm × 2.0 cm × 1.0 cm Gadolinium Aluminum Gallium Garnet (GAGG) scintillator, and the resulting device was tested using intense gamma radiation fields from a Cs-137 (1.5 kRad/h) and a Co-60 (10 kRad/h) irradiator. Measurements with Cs-137 provided a maximum power output (P max ) of ~288 nW, with a short-circuit current density (J sc ) of ~1.22 μA/cm 2 and an open-circuit voltage (V oc ) of ~0.34 V. In contrast, Co-60 irradiator gave a P max of 1.5 μW, with a J sc of ~4.73 μA/cm 2 and a V oc of ~0.38 V. The CdTe was also paired with a Lutetium-Yttrium Oxyorthosilicate (LYSO) crystal and tested with the Cs-137 source. The experiment presents a scalable option to reach to higher power outputs by harvesting gamma radiation fields in many cases where high radiation field demands heavy shielding and is often regarded as unwanted waste.

25 ENERGY STORAGE↗

FY17 Report for Instrumentation Development for the Transient Testing Program

This report details the technical activities and accomplishment carried out under the in-pile instrumentation work package supporting the transient testing program. These activities were performed in direct support of cross-cutting transient testing experiment objectives. The purpose of this report is to provide a complete summary of all work, which is of particular interest to nuclear irradiation test experimenters and in-pile instrumentation engineers with emphasis on transient testing applications. Development activities are focused on devices to perform online measurement of neutron flux, temperature, and mechanical behaviors in nuclear fuels experiments. A brief summary of activities and accomplishments is first provided for each major activity. Detailed reports are presented in appendices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation damage effects on solid state detectors

Totally depleted silicon diodes are discussed which are used as nuclear particle detectors in investigations of galactic and solar cosmic radiation and trapped radiation. A study of radiation and chemical effects on the diodes was conducted. Work on electron and proton irradiation of surface barrier detectors with thicknesses up to 1 mm was completed, and work on lithium-drifted silicon devices with thicknesses of several millimeters was begun.

Trainor, J. H.↗