Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ideality factor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Directional ballistic transport in the two-dimensional metal PdCoO2

Abstract In an idealized infinite crystal, the material properties are constrained by the symmetries of the unit cell. The point-group symmetry is broken by the sample shape of any finite crystal, but this is commonly unobservable in macroscopic metals. To sense the shape-induced symmetry lowering in such metals, long-lived bulk states originating from an anisotropic Fermi surface are needed. Here we show how a strongly facetted Fermi surface and the long quasiparticle mean free path present in microstructures of PdCoO 2 yield an in-plane resistivity anisotropy that is forbidden by symmetry on an infinite hexagonal lattice. We fabricate bar-shaped transport devices narrower than the mean free path from single crystals using focused ion beam milling, such that the ballistic charge carriers at low temperatures frequently collide with both of the side walls that define the channel. Two symmetry-forbidden transport signatures appear: the in-plane resistivity anisotropy exceeds a factor of 2, and a transverse voltage appears in zero magnetic field. Using ballistic Monte Carlo simulations and a numerical solution of the Boltzmann equation, we identify the orientation of the narrow channel as the source of symmetry breaking.

36 MATERIALS SCIENCE↗

An Analysis of MSFC Public Affairs Television and Target Audiences with Suggestions for Future Growth and Directions

Because of profound changes in government and the space program, this may be an ideal time to evaluate MSFC's Public Affairs television efforts. The changes are continued downsizing of government programs; reduction in research and development; changes in the space program from periodic manned launches to a full-time presence in space with Space Station; and greater emphasis on science and communicating science information. At the same time that NASA is undergoing change, the media and society are also undergoing substantial upheaval. Twenty-five years ago, the three main over-the-air television networks (ABC, CBS and NBC) had a 93 share of the television audience. We now have four popular over-the-air networks (ABC, CBS, NBC and Fox) who maintain a 52 percent share of the television audience. Technological development, competition, and changing consumer tastes have created specialized media and audiences. This media fragmentation is part of a normal maturation cycle of use or adoption. While phases in the cycle vary in length due to many factors, the cycle has been consistent and reflects patterns of adoption. The cycle is: (1) Elite Media usage, (2) Popular or Mass Media usage, and (3) Specialized Media usage. Another factor that affects the media development and adoption cycle is the creation of new and competing mass and personal mediums. While television remains the dominant and most popular mass medium, it is declining and we see (via cable television) specialized networks catering to small audience segments. Because of changing technology and consumer behavior, we may not see a dominant mass media like television again.

Smeyak, Gerald P.↗

Quantitative comparison between sub-millisecond time resolution single-molecule FRET measurements and 10-second molecular simulations of a biosensor protein

Molecular Dynamics (MD) simulations seek to provide atomic-level insights into conformationally dynamic biological systems at experimentally relevant time resolutions, such as those afforded by single-molecule fluorescence measurements. However, limitations in the time scales of MD simulations and the time resolution of single-molecule measurements have challenged efforts to obtain overlapping temporal regimes required for close quantitative comparisons. Achieving such overlap has the potential to provide novel theories, hypotheses, and interpretations that can inform idealized experimental designs that maximize the detection of the desired reaction coordinate. Here, we report MD simulations at time scales overlapping with in vitro single-molecule Förster (fluorescence) resonance energy transfer (smFRET) measurements of the amino acid binding protein LIV-BP SS at sub-millisecond resolution. Computationally efficient all-atom structure-based simulations, calibrated against explicit solvent simulations, were employed for sampling multiple cycles of LIV-BP SS clamshell-like conformational changes on the time scale of seconds, examining the relationship between these events and those observed by smFRET. The MD simulations agree with the smFRET measurements and provide valuable information on local dynamics of fluorophores at their sites of attachment on LIV-BP SS and the correlations between fluorophore motions and large-scale conformational changes between LIV-BP SS domains. We further utilize the MD simulations to inform the interpretation of smFRET data, including Förster radius (R 0 ) and fluorophore orientation factor (κ 2 ) determinations. The approach we describe can be readily extended to distinct biochemical systems, allowing for the interpretation of any FRET system conjugated to protein or ribonucleoprotein complexes, including those with more conformational processes, as well as those implementing multi-color smFRET.

59 BASIC BIOLOGICAL SCIENCES↗

Controlling Ion Uptake in Carboxylated Mixed Conductors

Organic mixed ionic‐electronic conductors (OMIECs) have garnered significant attention due to their capacity to transport both ions and electrons, making them ideal for applications in energy storage, neuromorphics, and bioelectronics. However, charge compensation mechanisms during the polymer redox process remain poorly understood, and are often oversimplified as single‐ion injection with little attention to counterion effects. To advance understanding and design strategies toward next‐generation OMIEC systems, a series of p‐channel carboxylated mixed conductors is investigated. Varying side‐chain functionality, distinctive swelling character is uncovered during electrochemical doping/dedoping with model chao‐/kosmotropic electrolytes. Carboxylic acid functionalized polymers demonstrate strong deswelling and mass reduction during doping, indicating cation expulsion, while ethoxycarbonyl counterparts exhibit prominent mass increase, pointing to an anion‐driven doping mechanism. By employing operando grazing incidence X‐ray fluorescence (GIXRF), it is revealed that the carboxyl functionalized polymer engages in robust cation interaction, whereas ester functionalization shifts the mechanism towards no cation involvement. It is demonstrated that cations are pivotal in mitigating swelling by counterbalancing anions, enabling efficient anion uptake without compromising performance. These findings underscore the transformative influence of functionality‐driven factors and side‐chain chemistry in governing ion dynamics and conduction, providing new frameworks for designing OMIECs with enhanced performance and reduced swelling.

carboxylated polythiophenes↗

Sparsified time-dependent Fourier neural operators for fusion simulations

This paper presents a sparsified Fourier neural operator for coupled time-dependent partial differential equations (ST-FNO) as an efficient machine learning surrogate for fluid and particle-based fusion codes such as NIMROD (Non-Ideal Magnetohydrodynamics with Rotation - Open Discussion) and GTC (Gyrokinetic Toroidal Code). ST-FNO leverages the structures in the governing equations and utilizes neural operators to represent Green's function-like numerical operators in the corresponding numerical solvers. Once trained, ST-FNO can rapidly and accurately predict dynamics in fusion devices compared with first-principle numerical algorithms. In general, ST-FNO represents an efficient and accurate machine learning surrogate for numerical simulators for multi-variable nonlinear time-dependent partial differential equations, with the proposed architectures and loss functions. The efficacy of ST-FNO has been demonstrated using quiescent H-mode simulation data from NIMROD and kink-mode simulation data from GTC. The ST-FNO H-mode results show orders of magnitude reduction in memory and central processing unit usage in comparison with the numerical solvers in NIMROD when computing fields over a selected poloidal plane. The ST-FNO kink-mode results achieve a factor of 2 reduction in the number of parameters compared to baseline FNO models without accuracy loss.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the frequency bifurcations of the MHD startup modes in NSTX

The observed bifurcations of the low frequency (<50 kHz) and low toroidal periodicity (n < 5) magnetohydrodynamic (MHD) activity often present in the initial part of the National Spherical Tokamak Experiment (NSTX) discharges can be explained by the evolution of the radial profile of the safety factor (q=rB φ /RB θ ) crossing multiple rational surfaces in the core. Important performance limiting instability mechanisms in the NSTX spherical tokamak are often linked to low frequency and low-n MHD activity. They are quite common in long-pulse NSTX plasmas. They can be present at the beginning of the plasma current flat-top, at the end of the discharge or during the whole duration, and they have been observed to deleteriously impact performance over a wide range of q 95 . An interesting feature observed in some NSTX discharges is the presence of a bifurcation in the frequency of the low n modes, as low as n = 1, that have frequencies comparable to the plasma core rotation divided by n. Equilibrium reconstructions constrained by magnetic diagnostics data and motional stark effect pitch angle radial profiles suggest that the observed bifurcations are linked to a fast evolving minimum value of q. Finally, 3D non-linear resistive MHD simulations show that these modes are ideal and exist as non-resonant before the correspondent rational surface enters the plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laboratory Study of the Torus Instability Threshold in Solar-relevant, Line-tied Magnetic Flux Ropes

Coronal mass ejections (CMEs) occur when long-lived magnetic flux ropes (MFRs) anchored to the solar surface destabilize and erupt away from the Sun. This destabilization is often described in terms of an ideal magnetohydrodynamic instability called the torus instability. It occurs when the external magnetic field decreases sufficiently fast such that its decay index, ${n}_{}=-z\,\partial (\mathrm{ln}{B}_{})/\partial z$, is larger than a critical value, $n\gt {n}_{\mathrm{cr}}^{}$, where ${n}_{\mathrm{cr}}^{}=1.5$ for a full, large aspect ratio torus. However, when this is applied to solar MFRs, a range of conflicting values for ${n}_{\mathrm{cr}}^{}$ is found in the literature. To investigate this discrepancy, we have conducted laboratory experiments on arched, line-tied flux ropes and applied a theoretical model of the torus instability. Our model describes an MFR as a partial torus with foot points anchored in a conducting surface and numerically calculates various magnetic forces on it. This calculation yields better predictions of ${n}_{\mathrm{cr}}^{}$ that take into account the specific parameters of the MFR. Here, we describe a systematic methodology to properly translate laboratory results to their solar counterparts, provided that the MFRs have a sufficiently small edge safety factor or, equivalently, a large enough twist. After this translation, our model predicts that ${n}_{\mathrm{cr}}^{}$ in solar conditions falls near ${n}_{\mathrm{cr}}^{\mathrm{solar}}\sim 0.9$ and within a larger range of ${n}_{\mathrm{cr}}^{\mathrm{solar}}\sim (0.7,1.2)$, depending on the parameters. The methodology of translating laboratory MFRs to their solar counterparts enables quantitative investigations of CME initiation through laboratory experiments. These experiments allow for new physics insights that are required for better predictions of space weather events but are difficult to obtain otherwise.

79 ASTRONOMY AND ASTROPHYSICS↗

Enhancing Lithium-Ion Battery Aging Simulations: Coupling a High-Resolution, 3D, Grain-Scale Electromechanical Model to a Single-Particle Model

One of the main goals in modeling lithium-ion batteries is to improve/predict longevity and resilience of new chemistries. Unfortunately, this requires simulation of thousands of charge/discharge cycles, which can be rather time consuming depending on the fidelity of the simulation. The purpose of this talk is to discuss a new modeling framework that couples a high-resolution, continuous damage model (CDM) to a single particle model (SPM) resulting in a good combination of speed and fidelity. In previous work, a 3D, continuum-level chemo-mechanical model was developed to investigate cracking within a single cathode particle comprised of hundreds to thousands of randomly oriented grains. The CDM predicted that particle fracture is primarily due to non-ideal grain interactions with slight dependence on high-rate charge demands. Essentially, when neighboring grains were misaligned, they expanded different rates relative to one another leading to high stresses and ultimately the formation of intraparticle cracks. The model predicted that small particles with large grains develop significantly less damage than larger particles with small grains. Finally, the model predicted most of the chemo-mechanical damage accumulates in the first charge after formation. This chemo-mechanical "damage saturation" effect indicated that initial particle fracture occurs within the first few cycles, while long-term cathode degradation is not solely chemo-mechanically induced. This led to a need for simulating fatigue-like mechanism that degrade the battery over longer time scales. In order to reach the time scales, need to resolve fatigue-like degradation, the CDM needs to be complemented by a faster model. Therefore, recent efforts have been focused on using results from the CDM to inform parameters within the SPM. These parameters are homogenization factors that are associated with diffusion, particle radius, and/or exchange current density. By coupling the CDM to the SPM, the aging simulation is broken up into two domains: short-term and long-term degradation. The short-term degradation occurs over a single cycle and is handled by the CDM due of its high fidelity, but relatively expensive computational cost. Such mechanism include break-in crack caused by mismatches in grain orientation. The long-term degradation occurs over tens of cycles and is handled by the SPM due it's computational efficiency. Most of the fatigue-like mechanism fall into this category. The eventual goal of this modeling framework is to upscale to a psudo-2D model allowing for full electrode simulation, which are informed by high-fidelity grain-scale simulations.

electrochemistry↗

3D-printed sheet jet for stable megahertz liquid sample delivery at X-ray free-electron lasers

X-ray free-electron lasers (XFELs) can probe chemical and biological reactions as they unfold with unprecedented spatial and temporal resolution. A principal challenge in this pursuit involves the delivery of samples to the X-ray interaction point in such a way that produces data of the highest possible quality and with maximal efficiency. This is hampered by intrinsic constraints posed by the light source and operation within a beamline environment. For liquid samples, the solution typically involves some form of high-speed liquid jet, capable of keeping up with the rate of X-ray pulses. However, conventional jets are not ideal because of radiation-induced explosions of the jet, as well as their cylindrical geometry combined with the X-ray pointing instability of many beamlines which causes the interaction volume to differ for every pulse. This complicates data analysis and contributes to measurement errors. An alternative geometry is a liquid sheet jet which, with its constant thickness over large areas, eliminates the problems related to X-ray pointing. Since liquid sheets can be made very thin, the radiation-induced explosion is reduced, boosting their stability. These are especially attractive for experiments which benefit from small interaction volumes such as fluctuation X-ray scattering and several types of spectroscopy. Although their use has increased for soft X-ray applications in recent years, there has not yet been wide-scale adoption at XFELs. Here, gas-accelerated liquid sheet jet sample injection is demonstrated at the European XFEL SPB/SFX nano focus beamline. Its performance relative to a conventional liquid jet is evaluated and superior performance across several key factors has been found. This includes a thickness profile ranging from hundreds of nanometres to 60 nm, a fourfold increase in background stability and favorable radiation-induced explosion dynamics at high repetition rates up to 1.13 MHz. Its minute thickness also suggests that ultrafast single-particle solution scattering is a possibility.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The onset of gravothermal oscillations in globular cluster evolution

We have carried out an extensive set of Fokker-Planck simulations of the evolution of globular clusters on very long timescales, up to 600 times the initial core collapse time t(sub cc). We consider an idealized equal mass star cluster, with a wide range of values for the total number of stars, 7000 less than N less than 2 x 10(exp 6). Our models include the heating effect of compact binaries formed in three-body encounters, which halts the initial core collapse and drives a core reexpansion. Postcollapse gravothermal oscillations of the cluster core are found to occur for all N approximately greater than or equal to 8000. For 8000 approximately less than or equal to N approximately less than or equal to 11,000, the oscillation has a simple, regular waveform with a single, well-defined period. For N approximately equals 12,000, the oscillations become nonlinear in a process resembling a period doubling. For N approximately greater than or equal to 14,000, the waveform of the oscillations becomes increasingly more irregular with increasing N, resembling chaotic behavior for N approximately greater than or equal to 15,000. During the oscillations, the core radius and core mass vary dramatically: by more than a factor of 10 for N greater than 15,000, by more than a factor of 100 for N greater than 5 x 10(exp 4), and by more than a factor of 1000 for N greater than 5 x 10(exp 5). However, even during the times of maximum expansion, the core contains only a small fraction of the cluster mass. For most N values, the maximum core mass at any time after core collapse is less than 1% of the cluster mass. The exceptions lie in the range 5 x 10(exp 4) approximately less than or equal to N approximately equal to or less than 2 x 10(exp 5), where the maximum post-collapse core mass reaches approximately 2% of the cluster mass. We discuss the observational implications of these predictions.

Breeden, Joseph L.↗

Effect of Elevated Pressure on the Heat Transfer and Power Requirements During Bridgman Growth of PMN-PT Crystals

Performance of the furnace during Bridgman growth of the lead magnesium niobate-lead titanate crystal (PMN-PT) is analyzed. PMN-PT is electrostrictive ceramic that has near ideal strain-voltage function. Furthermore piezoelectric (2000 to 2300 pC/N) and coupling (92 to 95%) constants are exceptionally good. Due to these properties PMN-PT has wide range of applications - from sonars to transducers in a high precision optical systems. In this research first attempt to crystallize PMN-PT in a Mellen type vertical Bridgman furnace was not successful, as melting temperature of precursor materials was not achieved. At this point choice was between building a new more powerful facility or finding ways to enhance performance of the existing furnace. Besides adjusting power supply to the individual heating elements, redesigning ampoule holding cartridge and improving furnace insulation one more radical improvement was proposed. The entire furnace was placed into the high pressure chamber. Further experiments confirmed that temperature inside the furnace was increased sufficiently to melt precursor materials to obtain PMN-PT. Numerical modeling is undertaken to find limitations of this technique and to predict temperature distribution inside the ampoule. It is of interest also to account for main factors contributing to a higher temperatures achieved in the furnace under the higher pressure (up to 10 atm.). Numerical model of the furnace is based on general purpose finite - element code FIDAP and on previous efforts to model Bridgman type furnace with multiply heaters. In order to account for all heat transfer mechanism involved - conduction, convection and radiation - different parts of the furnace are modeled in accordance with expected dominant mode of heat transfer - conduction in the solid parts, conduction and radiation in the ampoule, gas convection and conduction in the furnace openings complemented with wall-to-wall radiation. Because of these complicating factors, dimensional rather than non-dimensional modeling is performed using steady-state 2-D and 3-D models. Particular attention is paid to the modeling of radiation in a semitransparent material of ampoule 7 sapphire. The radiation model is validated by solving realistic test problem - conduction and radiation heat transfer in the fused quartz. Results are in agreement with both experimental and analytical data.

Bune, Andris↗

Residually Stressed Bimaterial Beam Specimen for Measuring Environmentally Assisted Crack Growth

Background: Subcritical crack growth can occur in a brittle material when the stress intensity factor is smaller than the fracture toughness if an oxidizing agent (such as water) is present at the crack tip. Objective: Here we present a novel bi-material beam specimen which can measure environmentally assisted crack growth rates. The specimen is “self-loaded” by residual stress and requires no external loading. Methods: Two materials with different coefficient of thermal expansion are diffusion bonded at high temperature. After cooling to room temperature a subcritical crack is driven by thermal residual stresses. A finite element model is used to design the specimen geometry in terms of material properties in order to achieve the desired crack tip driving force. Results: The specimen is designed so that the crack driving force decreases as the crack extends, thus enabling the measurement of the crack velocity versus driving force relationship with a single test. The method is demonstrated by measuring slow crack growth data in soda lime silicate glass and validated by comparison to previously published data. Conclusions: The self-loaded nature of the specimen makes it ideal for measuring the very low crack velocities needed to predict brittle failure at long lifetimes.

36 MATERIALS SCIENCE↗

A sample of dust attenuation laws for Dark Energy Survey supernova host galaxies

Type Ia supernovae (SNe Ia) are useful distance indicators in cosmology, provided their luminosity is standardized by applying empirical corrections based on light-curve properties. One factor behind these corrections is dust extinction, which is accounted for in the color–luminosity relation of the standardization. This relation is usually assumed to be universal, which can potentially introduce systematics into the standardization. The “mass step” observed for SN Ia Hubble residuals has been suggested as one such systematic. We seek to obtain a more complete view of dust attenuation properties for a sample of 162 SN Ia host galaxies and to probe their link to the mass step. We inferred attenuation laws toward hosts from both global and local (4 kpc) Dark Energy Survey photometry and composite stellar population model fits. We recovered a relation between the optical depth and the attenuation slope, best explained by differing star-to-dust geometry for different galaxy orientations, which is significantly different from the optical depth and extinction slope relation observed directly for SNe. We obtain a large variation of attenuation slopes and confirm these change with host properties, such as the stellar mass and age, meaning a universal SN Ia correction should ideally not be assumed. Analyzing the cosmological standardization, we find evidence for a mass step and a two-dimensional “dust step”, both more pronounced for red SNe. Although comparable, the two steps are not found to be completely analogous. We conclude that host galaxy dust data cannot fully account for the mass step, using either an alternative SN standardization with extinction proxied by host attenuation or a dust-step approach.

79 ASTRONOMY AND ASTROPHYSICS↗

Preliminary RAM-RODD results for the MUSiC subcritical configurations

The Measurement of Uranium Subcritical and Critical (MUSiC) was performed at the DOE’s National Criticality Experiments Research Center (NCERC) located in the Nevada National Security Site (NNSS). The measurement utilized the Rocky Flats shells to perform benchmark measurements of similar highly enriched uranium (HEU) systems that span a wide range of reactivities. The Rocky Flats (RF) shells are 93.16% U-235 enriched metal hemishells that can be stacked concentrically. Ten configurations were measured with effective multiplication factors spanning between deeply subcritical (~ 0.64) through delayed critical. Details of the measured configurations are listed in Table 1. This unique set of measurements with its large span of reactivies is being used to determine the range over which neutron noise techniques such as Feynman variance-to-mean, Rossi-alpha, and pulsed neutron source techniques can be accurately employed for a bare HEU system. The results of the measurements will be published as a benchmark in The International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The results will support the growing amount of subcritical benchmark data, such as the SCRaP measurements, that is available to the community. The measurements were performed using several different detector systems for the purposes of cross-validation and obtaining detector independent results. Four detector systems were deployed, three by the NCERC team and one from the University of Michigan. The detector systems included a Neutron Multiplicity Array Detector (NoMAD) system (similar to the MC-15), four small volume 0.635 cm (Ø) × 7.59 cm 3 He detectors (ideal for measuring prompt neutron decay constants due to their fast recovery speed), the Rossi Alpha Measurements – Rapid Organic (n, γ) Discrimination Detector (RAM-RODD), and the Organic Scintillator Array (OSCAR). RAM-RODD is an array of eight 5.08 cm (Ø) × 5.08 cm EJ-309 organic scintillator detectors. OSCAR is a University of Michigan system and is an array of twelve 5.08 cm (Ø) × 5.08 cm stilbene detectors. Details of measurements performed with OSCAR will be discussed in a separate talk. The focus of this work is preliminary results obtained by RAM-RODD for the 8 subcritical configurations. Additional details on the measurements and on the setup and deployment of RAM-RODD will be discussed. Preliminary neutron noise analysis results including Rossi-alpha and Feynman-alpha will also be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Black hole scattering and partition functions

When computing the ideal gas thermal canonical partition function for a scalar outside a black hole horizon, one encounters the divergent single-particle density of states (DOS) due to the continuous nature of the normal mode spectrum. Recasting the Lorentzian field equation into an effective 1D scattering problem, we argue that the scattering phases encode non-trivial information about the DOS and can be extracted by “renormalizing” the DOS with respect to a reference. This defines a renormalized free energy up to an arbitrary additive constant. Interestingly, we discover that the 1-loop Euclidean path integral, as computed by the Denef-Hartnoll-Sachdev formula, fixes the reference free energy to be that on a Rindler-like region, and the renormalized DOS captures the quasinormal modes for the scalar. We support these claims with the examples of scalars on static BTZ, Nariai black holes and the de Sitter static patch. For black holes in asymptotically flat space, the renormalized DOS is captured by the phase of the transmission coefficient whose magnitude squared is the greybody factor. We comment on possible connections with recent works from an algebraic point of view.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Study on Effect of Tuning Capacitor in Dynamic Radioisotope Power Systems

This study presents the effect of the tuning capacitor on stability and electrical power output of a gas-bearing based free-piston Stirling convertor (FPSC) when operating on a fixed-frequency type controller. It has been widely accepted that the tuning capacitor is an important circuit component of the FPSC to stabilize piston amplitude and maximize electrical power output by correcting the power factor. Models suggest the stability of the FPSC is strongly coupled to the tuning capacitance, while the coupling to the electrical power output is weak. This applies to cases where the operating frequency of the FPSC is fixed by a fixed-frequency controller and other operating conditions, such as the hot-end and cold-end temperatures, piston amplitude, and pressure are constant. To verify the modeling analysis results, an Advanced Stirling Convertor (ASC) was controlled by an AC power supply and the piston amplitude, hot-end temperature, cold-end temperature, and pressure are actively controlled to 4.3mm, 760˚C, 40˚C and 485psig, respectively, while the tuning capacitor value was changed from 840μF to 1040μF and 1240μF. Furthermore, the vibration test results of the ASC with different tuning capacitor values are also presented to show the effect of the tuning capacitor on stability. The experimental test results verified that the effect of tuning capacitor on electrical power output is negligible while the effect on stability is rather noticeable. Therefore, the ideal tuning capacitor value should be selected based on required stability of the FPSC.

Free-Piston Stirling Convertor Controller↗

Single-Vector Calibration of Wind-Tunnel Force Balances

An improved method of calibrating a wind-tunnel force balance involves the use of a unique load application system integrated with formal experimental design methodology. The Single-Vector Force Balance Calibration System (SVS) overcomes the productivity and accuracy limitations of prior calibration methods. A force balance is a complex structural spring element instrumented with strain gauges for measuring three orthogonal components of aerodynamic force (normal, axial, and side force) and three orthogonal components of aerodynamic torque (rolling, pitching, and yawing moments). Force balances remain as the state-of-the-art instrument that provide these measurements on a scale model of an aircraft during wind tunnel testing. Ideally, each electrical channel of the balance would respond only to its respective component of load, and it would have no response to other components of load. This is not entirely possible even though balance designs are optimized to minimize these undesirable interaction effects. Ultimately, a calibration experiment is performed to obtain the necessary data to generate a mathematical model and determine the force measurement accuracy. In order to set the independent variables of applied load for the calibration 24 NASA Tech Briefs, October 2003 experiment, a high-precision mechanical system is required. Manual deadweight systems have been in use at Langley Research Center (LaRC) since the 1940s. These simple methodologies produce high confidence results, but the process is mechanically complex and labor-intensive, requiring three to four weeks to complete. Over the past decade, automated balance calibration systems have been developed. In general, these systems were designed to automate the tedious manual calibration process resulting in an even more complex system which deteriorates load application quality. The current calibration approach relies on a one-factor-at-a-time (OFAT) methodology, where each independent variable is incremented individually throughout its full-scale range, while all other variables are held at a constant magnitude. This OFAT approach has been widely accepted because of its inherent simplicity and intuitive appeal to the balance engineer. LaRC has been conducting research in a "modern design of experiments" (MDOE) approach to force balance calibration. Formal experimental design techniques provide an integrated view to the entire calibration process covering all three major aspects of an experiment; the design of the experiment, the execution of the experiment, and the statistical analyses of the data. In order to overcome the weaknesses in the available mechanical systems and to apply formal experimental techniques, a new mechanical system was required. The SVS enables the complete calibration of a six-component force balance with a series of single force vectors.

Parker, P. A.↗

Towards modelling AR Sco: generalized particle dynamics and strong radiation-reaction regimes

Numerical simulations of relativistic plasmas have become more feasible, popular, and crucial for various astrophysical sources with the availability of computational resources. The necessity for high-accuracy particle dynamics is especially highlighted in pulsar modelling due to the extreme associated electromagnetic fields and particle Lorentz factors. Including the radiation-reaction force in the particle dynamics adds even more complexity to the problem, but is crucial for such extreme astrophysical sources. We have also realized the need for such modelling concerning magnetic mirroring and particle injection models proposed for AR Sco, the first white dwarf pulsar. This paper demonstrates the benefits of using higher-order explicit numerical integrators with adaptive time-step methods to solve the full particle dynamics with radiation-reaction forces included. We show that for standard test scenarios, namely various combinations of uniform E- and B-fields and a static dipole B-field, the schemes we use are equivalent to and in extreme field cases outperform standard symplectic integrators in accuracy. We show that the higher-order schemes have massive computational time improvements due to the adaptive time-steps we implement, especially in non-uniform field scenarios and included radiation reaction where the particle gyro-radius rapidly changes. When balancing accuracy and computational time, we identified the adaptive Dormand–Prince eighth-order scheme to be ideal for our use cases. The schemes we use maintain accuracy and stability in describing the particle dynamics and we indicate how a charged particle enters radiation-reaction equilibrium and conforms to the analytical Aristotelian Electrodynamics expectations.

79 ASTRONOMY AND ASTROPHYSICS↗