Engineering of Data Acquiring Mobile Software and Sustainable End-User Applications

The criteria for which data acquiring software and its supporting infrastructure should be designed should take the following two points into account: the reusability and organization of stored online and remote data and content, and an assessment on whether abandoning a platform optimized design in favor for a multi-platform solution significantly reduces the performance of an end-user application. Furthermore, in-house applications that control or process instrument acquired data for end-users should be designed with a communication and control interface such that the application's modules can be reused as plug-in modular components in greater software systems. The application of the above mentioned is applied using two loosely related projects: a mobile application, and a website containing live and simulated data. For the intelligent devices mobile application AIDM, the end-user interface have a platform and data type optimized design, while the database and back-end applications store this information in an organized manner and manage access to that data to only to authorized user end application(s). Finally, the content for the website was derived from a database such that the content can be included and uniform to all applications accessing the content. With these projects being ongoing, I have concluded from my research that the applicable methods presented are feasible for both projects, and that a multi-platform design for the mobile application only marginally drop the performance of the mobile application.

Smith, Benton T.↗

Multi-Bandwidth Frequency Selective Surfaces for Near Infrared Filtering: Design and Optimization

Frequency selective surfaces are widely used in the microwave and millimeter wave regions of the spectrum for filtering signals. They are used in telecommunication systems for multi-frequency operation or in instrument detectors for spectroscopy. The frequency selective surface operation depends on a periodic array of elements resonating at prescribed wavelengths producing a filter response. The size of the elements is on the order of half the electrical wavelength, and the array period is typically less than a wavelength for efficient operation. When operating in the optical region, diffraction gratings are used for filtering. In this regime the period of the grating may be several wavelengths producing multiple orders of light in reflection or transmission. In regions between these bands (specifically in the infrared band) frequency selective filters consisting of patterned metal layers fabricated using electron beam lithography are beginning to be developed. The operation is completely analogous to surfaces made in the microwave and millimeter wave region except for the choice of materials used and the fabrication process. In addition, the lithography process allows an arbitrary distribution of patterns corresponding to resonances at various wavelengths to be produced. The design of sub-millimeter filters follows the design methods used in the microwave region. Exacting modal matching, integral equation or finite element methods can be used for design. A major difference though is the introduction of material parameters and thicknesses that may not be important in longer wavelength designs. This paper describes the design of multi- bandwidth filters operating in the 1-5 micrometer wavelength range. This work follows on a previous design. In this paper extensions based on further optimization and an examination of the specific shape of the element in the periodic cell will be reported. Results from the design, manufacture and test of linear wedge filters built using microlithographic techniques and used in spectral imaging applications will be presented.

Cwik, Tom↗

Multi-Bandwidth Frequency Selective Surfaces for Near Infrared Filtering: Design and Optimization

Frequency selective surfaces are widely used in the microwave and millimeter wave regions of the spectrum for filtering signals. They are used in telecommunication systems for multi-frequency operation or in instrument detectors for spectroscopy. The frequency selective surface operation depends on a periodic array of elements resonating at prescribed wavelengths producing a filter response. The size of the elements is on the order of half the electrical wavelength, and the array period is typically less than a wavelength for efficient operation. When operating in the optical region, diffraction gratings are used for filtering. In this regime the period of the grating may be several wavelengths producing multiple orders of light in reflection or transmission. In regions between these bands (specifically in the infrared band) frequency selective filters consisting of patterned metal layers fabricated using electron beam lithography are beginning to be developed. The operation is completely analogous to surfaces made in the microwave and millimeter wave region except for the choice of materials used and the fabrication process. In addition, the lithography process allows an arbitrary distribution of patterns corresponding to resonances at various wavelengths to be produced. The design of sub-millimeter filters follows the design methods used in the microwave region. Exacting modal matching, integral equation or finite element methods can be used for design. A major difference though is the introduction of material parameters and thicknesses tha_ may not be important in longer wavelength designs. This paper describes the design of multi-bandwidth filters operating in the I-5 micrometer wavelength range. This work follows on previous design [1,2]. In this paper extensions based on further optimization and an examination of the specific shape of the element in the periodic cell will be reported. Results from the design, manufacture and test of linear wedge filters built using micro-lithographic techniques and used ir spectral imaging applications will be presented.

Cwik, Tom↗

Constrained variational optimization of counting-time allocation in sequential scattering measurements: Application to Bonse–Hart USANS

Sequential scattering measurements are often performed under a fixed experimental-time budget, even though the expected count rate varies strongly across the measured coordinate. When the dwell time at each measurement position can be controlled independently, this variation creates a general resource-allocation problem: how should the available time be distributed to minimize the uncertainty of the reconstructed profile? We formulate this problem as a constrained variational optimization for measurements governed by Poisson counting statistics. When each measurement is treated independently, minimizing the averaged squared relative uncertainty yields an inverse-square-root intensity allocation. The formulation is then generalized to include correlations between neighboring measurements and an instrumental resolution operator, leading to an allocation criterion that equalizes the marginal reduction in posterior uncertainty per unit measurement time. Bonse–Hart ultra-small-angle neutron scattering (USANS), in which reciprocal space is sampled sequentially through analyzer-angle stepping, provides an experimentally grounded application. Computational benchmarking shows that the optimized allocation outperforms uniform-time and constant-relative-error strategies, while application to an experimentally measured graphite USANS profile from the Spallation Neutron Source, using Poisson resampling under alternative schedules, demonstrates how counting time should be redistributed toward weak-intensity regions under an identical total duration. The resulting framework applies to sequential scattering and related scanning measurements whenever local dwell times are adjustable and directly determine the measurement uncertainties, and when the relevant correlation and instrumental-response models are available.

Tung, Chi-Huan [ORNL] (ORCID:0000000221972074)↗

STS-45 Space Shuttle mission report

The STS-45 Space Shuttle Program Mission Report contains a summary of the vehicle subsystem operations during the forty-sixth flight of the Space Shuttle Program and the eleventh flight of the Orbiter Vehicle Atlantis (OV-104). In addition to the Atlantis vehicle, the flight vehicle consisted of the following: an External Tank (ET) designated as ET-44 (LWT-37); three Space Shuttle main engines (SSME's), which were serial numbers 2024, 2012, and 2028 in positions 1, 2, and 3, respectively; and two Solid Rocket Boosters (SRB's) designated as BI-049. The lightweight redesigned Solid Rocket Motors (RSRM's) installed in each of the SRB's were designated as 360L021A for the left SRM and 360W021B for the right SRM. The primary objective of this mission was to successfully perform the planned operations of the Atmospheric Laboratory for Applications and Science-1 (ATLAS-1) and the Shuttle Solar Backscatter Ultraviolet Instrument (SSBUV) payloads. The secondary objectives were to successfully perform all operations necessary to support the requirements of the following: the Space Tissue Loss-01 (STL-01) experiment; the Radiation Monitoring Equipment-3 (RME-3) experiment; the Visual Function Tester-2 (VFT-2) experiment; the Cloud Logic to Optimize use of Defense System (CLOUDS-1A) experiment; the Shuttle Amateur Radio Experiment 2 (SAREX-2) Configuration B; the Investigation into Polymer Membranes Processing experiment; and the Get-Away Special (GAS) payload G-229. The Ultraviolet Plume Instrument (UVPI) was a payload of opportunity that required no special maneuvers. In addition to the primary and secondary objectives, the crew was tasked to perform as many as 10 Development Test Objectives (DTO'S) and 14 Detailed Supplementary Objectives (DSO's).

Fricke, Robert W.↗

Evaluation and optimization of lidar temperature analysis algorithms using simulated data

The middle atmosphere (20 to 90 km altitude) ha received increasing interest from the scientific community during the last decades, especially since such problems as polar ozone depletion and climatic change have become so important. Temperature profiles have been obtained in this region using a variety of satellite-, rocket-, and balloon-borne instruments as well as some ground-based systems. One of the more promising of these instruments, especially for long-term high resolution measurements, is the lidar. Measurements of laser radiation Rayleigh backscattered, or Raman scattered, by atmospheric air molecules can be used to determine the relative air density profile and subsequently the temperature profile if it is assumed that the atmosphere is in hydrostatic equilibrium and follows the ideal gas law. The high vertical and spatial resolution make the lidar a well adapted instrument for the study of many middle atmospheric processes and phenomena as well as for the evaluation and validation of temperature measurements from satellites, such as the Upper Atmosphere Research Satellite (UARS). In the Network for Detection of Stratospheric Change (NDSC) lidar is the core instrument for measuring middle atmosphere temperature profiles. Using the best lidar analysis algorithm possible is therefore of crucial importance. In this work, the JPL and CNRS/SA lidar analysis software were evaluated. The results of this evaluation allowed the programs to be corrected and optimized and new production software versions were produced. First, a brief description of the lidar technique and the method used to simulate lidar raw-data profiles from a given temperature profile is presented. Evaluation and optimization of the JPL and CNRS/SA algorithms are then discussed.

Leblanc, Thierry↗

Adaptive Data Screening for Multi-Angle Polarimetric Aerosol and Ocean Color Remote Sensing Accelerated by Automatic Differentiation

Remote sensing measurements from multi-angle polarimeters (MAPs) contain rich aerosol microphysical property information, and these sensors have been used to perform retrievals in optically complex atmosphere and ocean systems. Previous studies have concluded that, generally, five moderately separated viewing angles in each spectral band provide sufficient accuracy for aerosol property retrievals, with performance gradually saturating as angles are added above that threshold. The Hyper-Angular Rainbow Polarimeter (HARP) instruments provide high angular sampling with a total of 90-120 unique angles across four bands, a capability developed mainly for liquid cloud retrievals. In practice, not all view angles are optimal for aerosol retrievals due to impacts of clouds, sun glint, and other impediments. The many viewing angles of HARP can provide resilience to these effects, if the impacted views are screened from the dataset, as the remaining views may be sufficient for successful analysis. In this study, we discuss how the number of available viewing angles impacts aerosol and ocean color retrieval uncertainties, as applied to two versions of the HARP instrument. AirHARP is an airborne prototype that was deployed in the ACEPOL field campaign, while HARP2 is an instrument in development for the upcoming NASA Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission. Based on synthetic data, we find that a total of 20-30 angles across all bands (i.e. five to eight viewing angles per band) are sufficient to achieve good retrieval performance. Following from this result, we develop an adaptive multi-angle polarimetric data screening (MAPDS) approach to evaluate data quality by comparing measurements with their best-fitted forward model. The FastMAPOL retrieval algorithm is used to retrieve scene geophysical values, by matching an efficient, deep learning-based, radiative transfer emulator to observations. The data screening method effectively identifies and removes viewing angles affected by thin cirrus clouds and other anomalies, improving retrieval performance. This was tested with AirHARP data, and we found agreement with the High Spectral Resolution Lidar-2 (HSRL-2) aerosol data. The data screening approach can be applied to modern satellite remote sensing missions, such as PACE, where a large amount of multi-angle, hyperspectral, polarimetric measurements will be collected.

multi-angle polarimeter↗

Optimized Biasing of Pump Laser Diodes in a Highly Reliable Metrology Source for Long-Duration Space Missions

Optical metrology system reliability during a prolonged space mission is often limited by the reliability of pump laser diodes. We developed a metrology laser pump module architecture that meets NASA SIM Lite instrument optical power and reliability requirements by combining the outputs of multiple single-mode pump diodes in a low-loss, high port count fiber coupler. We describe Monte-Carlo simulations used to calculate the reliability of the laser pump module and introduce a combined laser farm aging parameter that serves as a load-sharing optimization metric. Employing these tools, we select pump module architecture, operating conditions, biasing approach and perform parameter sensitivity studies to investigate the robustness of the obtained solution.

808 mm diode pumps↗

Optical Alignment of the Chromospheric Lyman-Alpha SpectroPolarimeter using Sophisticated Methods to Minimize Activities under Vacuum

The Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) is a sounding-rocket instrument developed at the National Astronomical Observatory of Japan (NAOJ) as a part of an international collaboration. The in- strument main scientific goal is to achieve polarization measurement of the Lyman-alpha line at 121.56 nm emitted from the solar upper-chromosphere and transition region with an unprecedented 0.1% accuracy. For this purpose, the optics are composed of a Cassegrain telescope coated with a "cold mirror" coating optimized for UV reflection and a dual-channel spectrograph allowing for simultaneous observation of the two orthogonal states of polarization. Although the polarization sensitivity is the most important aspect of the instrument, the spatial and spectral resolutions of the instrument are also crucial to observe the chromospheric features and resolve the Ly- pro les. A precise alignment of the optics is required to ensure the resolutions, but experiments under vacuum conditions are needed since Ly-alpha is absorbed by air, making the alignment experiments difficult. To bypass this issue, we developed methods to align the telescope and the spectrograph separately in visible light. We will explain these methods and present the results for the optical alignment of the CLASP telescope and spectrograph. We will then discuss the combined performances of both parts to derive the expected resolutions of the instrument, and compare them with the flight observations performed on September 3rd 2015.

CLASP↗

Implanted Silicon Resistor Layers for Efficient Terahertz Absorption

Broadband absorption structures are an essential component of large format bolometer arrays for imaging GHz and THz radiation. We have measured electrical and optical properties of implanted silicon resistor layers designed to be suitable for these absorbers. Implanted resistors offer a low-film-stress, buried absorber that is robust to longterm aging, temperature, and subsequent metals processing. Such an absorber layer is readily integrated with superconducting integrated circuits and standard micromachining as demonstrated by the SCUBA II array built by ROE/NIST (1). We present a complete characterization of these layers, demonstrating frequency regimes in which different recipes will be suitable for absorbers. Single layer thin film coatings have been demonstrated as effective absorbers at certain wavelengths including semimetal (2,3), thin metal (4), and patterned metal films (5,6). Astronomical instrument examples include the SHARC II instrument is imaging the submillimeter band using passivated Bi semimetal films and the HAWC instrument for SOFIA, which employs ultrathin metal films to span 1-3 THz. Patterned metal films on spiderweb bolometers have also been proposed for broadband detection. In each case, the absorber structure matches the impedance of free space for optimal absorption in the detector configuration (typically 157 Ohms per square for high absorption with a single or 377 Ohms per square in a resonant cavity or quarter wave backshort). Resonant structures with -20% bandwidth coupled to bolometers are also under development; stacks of such structures may take advantage of instruments imaging over a wide band. Each technique may enable effective absorbers in imagers. However, thin films tend to age, degrade or change during further processing, can be difficult to reproduce, and often exhibit an intrinsic granularity that creates complicated frequency dependence at THz frequencies. Thick metal films are more robust but the requirement for patterning can limit their absorption at THz frequencies and their heat capacity can be high. patterned absorber structures that offer low heat capacity, absence of aging, and uniform, predictable behavior at THz frequencies. We have correlated DC electrical and THz optical measurements of a series of implanted layers and studied their frequency dependence of optical absorption from .3 to 10 THz at cryogenic temperatures. We have modeled the optical response to determine the suitability of the implanted silicon resistor as a function of resistance in the range 10 Ohms/sq to 300 Ohms/sq.

Chervenak, J. A.↗

Conceptual Design of the Moderator Test Station at the Spallation Neutron Source

We describe the Moderator Test Station (MTS), under construction at the Spallation Neutron Source. We will leverage the Beam Test Facility (BTF) at the Spallation Neutron Source to provide a moderator neutronics test stand with which we will verify the anticipated performance gains expected and required from the innovative moderator concepts central to the SNS Second Target Station (STS) and the future of the First Target Station (FTS). These concepts include large-volume para-hydrogen moderators and high-brightness tube moderators. The MTS will add to the existing BTF a proton beam chopper similar to that already used in the SNS at the RFQ exit (the so-called MEBT chopper), various proton beam transport components, a neutron-producing target, a cryogenic moderator test stand, a reflector-shielding assembly, and a performance assessment neutron beamline. The MTS will provide the ability to test a wide variety of moderators in a prototypic configuration, simultaneously measuring the neutronic performance of the moderator concept central to the anticipated STS gains and developing the instrumentation necessary to provide that performance in a production environment. The presentation will describe the MTS, its progress, and the way we optimize the prototypic nature of the moderators we will test.

Iverson, Erik B↗

DESI DR1 Lyα 1D power spectrum: the optimal estimator measurement

The one-dimensional power spectrum P 1D of Lyα forest offers rich insights into cosmological and astrophysical parameters, including constraints on the sum of neutrino masses, warm dark matter models, and the thermal state of the intergalactic medium. We present the measurement of P 1D using the optimal quadratic maximum likelihood estimator applied to over 300,000 Lyα quasars from Data Release 1 (DR1) of the Dark Energy Spectroscopic Instrument (DESI) survey. This sample represents the largest to date for P 1D measurements and is larger than the Extended Baryon Oscillation Spectroscopic Survey (eBOSS) by a factor of 1.7. We conduct a meticulous investigation of instrumental and analysis systematics and quantify their impact on P 1D . This includes the development of a cross-exposure estimator that eliminates the need to model the pipeline noise and has strong potential for future P 1D measurements. We also present new insights into metal contamination through the 1D correlation function. Using a fitting function we measure the evolution of the Lyα forest bias with high precision: b F (z) = (-0.218 ± 0.002) × ((1 + z)/4) 2.96±0.06 . In a companion validation paper, we substantially extend our previous suite of CCD image simulations to quantify the pipeline's exquisite performance accurately. In another companion paper, we present DR1 P 1D measurements using the Fast Fourier Transform (FFT) approach to power spectrum estimation. These two measurements produce a forest bias parameter that differs by 2.2 sigma. However, our model is simplistic, so this disagreement will be investigated in future work.

Lyman alpha forest↗

Techniques for the analysis of data from coded-mask X-ray telescopes

Several techniques useful in the analysis of data from coded-mask telescopes are presented. Methods of handling changes in the instrument pointing direction are reviewed and ways of using FFT techniques to do the deconvolution considered. Emphasis is on techniques for optimally-coded systems, but it is shown that the range of systems included in this class can be extended through the new concept of 'partial cycle averaging'.

Skinner, G. K.↗

Hormone purification by isoelectric focusing in space

The objective of the program was the definition and development of optimal methods for electrophoretic separations in microgravity. The approach is based on a triad consisting of ground based experiments, mathematical modeling and experiments in microgravity. Zone electrophoresis is a rate process, where separation is achieved in uniform buffers on the basis of differences in electrophoretic mobilities. Optimization and modeling of continuous flow electrophoresis mainly concern the hydrodynamics of the flow process, including gravity dependent fluid convection due to density gradients and gravity independent electroosmosis. Optimization of focusing requires a more complex model describing the molecular transport processes involved in electrophoresis of interacting systems. Three different focusing instruments were designed, embodying novel principles of fluid stabilization. Fluid stability was achieved by: (1) flow streamlining by means of membrane elements in combination with rapid fluid recycling; (2) apparatus rotation in combination with said membrane elements; and (3) shear stress induced by rapid recycling through a narrow gap channel.

Bier, M.↗

Studies of the Martian Magnetic Field

This report covers two awards: the first NAGW-2573 was awarded to enable participation in the Mars 94 mission that slipped to become the Mars 96 mission. Upon the unfortunate failure of Mars 96 to achieve its intended trajectory, the second grant was awarded to closeout the Mars 96 activities. Our initial efforts concentrated on assisting our colleagues: W. Riedler, K. Schwingenschuh, K. Gringanz, M. Verigin and Ye. Yeroshenko with advice on the development of the magnetic field portion of the investigation and to help them with test activities. We also worked with them to properly analyze the Phobos magnetic field and plasma data in order to optimize the return from the Mars 94/96 mission. This activity resulted in 18 papers on Mars scientific topics, and two on the instrumentation. One of these latter two papers was the last of the papers written, and speaks to the value of the closeout award. These 20 papers are listed in the attached bibliography. Because we had previously studied Venus and Titan and since it was becoming evident that the magnetic field was very weak, we compared the various properties of the Martian interaction with those of the analogous interactions at Venus and Titan while other papers simply analyzed the properties of the interaction as Phobos 2 observed them. One very interesting observation was the identification of ions picked up in the solar wind, originating in Mars neutral atmosphere. These had been predicted by our earlier observation of cyclotron waves at the proton gyrofrequency in the region upstream from Mars in the solar wind. Of course, the key question we addressed was that of the intrinsic or induced nature of the Martian magnetic field. We found little evidence for the former and much for the latter point of view. We also discussed the instrumentation planned for the Mars balloon and the instrumentation on the orbiter. In all these studies were very rewarding despite the short span of the Phobos data. Although they did not affect the eventual analysis of the Mars 96 data, these studies did pave the way for the Mars Global Surveyor and have been fully confirmed by the measurements at much closer distances than Phobos 2 ever reached. No patents or inventions resulted from the work.

Russell, C. T.↗

Overview of NASA Advanced Transportation Technologies Program

A General Overview of NASA Advanced Transportation Technologies Program is presented. The contents include: 1) Center-TRACON Automation System (CTAS) which provides automation tools to assist air traffic controllers in planning and controlling air traffic arriving into major airports; 2) Surface Movement Advisor (SMA) for expediting and optimizing aircraft operations on the airport surface; and 3) Terminal Area Productivity Program (TAP), which is aimed at improving airport throughput in instrument meteorological conditions to match that attainable in clear weather.

Ashford, Rose↗

Solar Flight on Mars and Venus

Solar powered aircraft are of interest for exploring both Mars and Venus. The thin atmosphere of Mars presents a difficult environment for flying. It is clear that a new approach is needed. By making a totally solar airplane, we can eliminate many of the heavy components, and make an airplane that can fly without fuel. Using high efficiency solar cells, we can succeed with an airplane design that can fly for up to 6 hours in near-equatorial regions of Mars (4 hours of level flight, plus two hours of slow descent), and potentially fly for many days in the polar regions. By designing an airplane for a single day flight. In particular, this change means that we no longer have to cope with the weight of the energy storage system that made previous solar powered airplanes for Mars impractical). The new airplane concept is designed to fly only under the optimal conditions: near equatorial flight, at the subsolar point, near noon. We baseline an 8 kg airplane, with 2 kg margin. Science instruments will be selected with the primary criterion of low mass. Solar-powered aircraft are also quite interesting for the exploration of Venus. Venus provides several advantages for flying a solar-powered aircraft. At the top of the cloud level, the solar intensity is comparable to or greater than terrestrial solar intensities. The atmospheric pressure makes flight much easier than on planets such as Mars. The atmospheric pressure on Venus is presented. From an altitude of approximately 45 km (pressure = 2 bar), to approximately 60 km (pressure = 0.2 bar), terrestrial airplane experience can be easily applied to a Venus airplane design. At these flight altitudes, the temperature varies from 80 C at 45 km, decreasing to -35 C at 60 km. Also, the slow rotation of Venus allows an airplane to be designed for flight within continuous sunlight, eliminating the need for energy storage for nighttime flight. These factors make Venus a prime choice for a long-duration solar-powered aircraft. Fleets of solar-powered aircraft could provide an architecture for efficient and low-cost comprehensive coverage for a variety of scientific missions. Exploratory planetary mapping and atmospheric sampling can lead to a greater understanding of the greenhouse effect not only on Venus but on Earth as well.

Landis, Geoffrey A.↗

Least-Squares Self-Calibration of Imaging Array Data

When arrays are used to collect multiple appropriately-dithered images of the same region of sky, the resulting data set can be calibrated using a least-squares minimization procedure that determines the optimal fit between the data and a model of that data. The model parameters include the desired sky intensities as well as instrument parameters such as pixel-to-pixel gains and offsets. The least-squares solution simultaneously provides the formal error estimates for the model parameters. With a suitable observing strategy, the need for separate calibration observations is reduced or eliminated. We show examples of this calibration technique applied to HST NICMOS observations of the Hubble Deep Fields and simulated SIRTF IRAC observations.

Arendt, R. G.↗