Search NASA⌕ Search

SEARCH · Search NASA

Results for “Interface reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Electronic band alignment and electron transport in Cr/BaTiO{sub 3}/Pt ferroelectric tunnel junctions

Electroresistance in ferroelectric tunnel junctions is controlled by changes in the electrostatic potential profile across the junction upon polarization reversal of the ultrathin ferroelectric barrier layer. Here, hard X-ray photoemission spectroscopy is used to reconstruct the electric potential barrier profile in as-grown Cr/BaTiO{sub 3}(001)/Pt(001) heterostructures. Transport properties of Cr/BaTiO{sub 3}/Pt junctions with a sub-{mu}m Cr top electrode are interpreted in terms of tunneling electroresistance with resistance changes of a factor of {approx}30 upon polarization reversal. By fitting the I-V characteristics with the model employing an experimentally determined electric potential barrier we derive the step height changes at the BaTiO{sub 3}/Pt (Cr/BaTiO{sub 3}) interface +0.42(-0.03) eV following downward to upward polarization reversal.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Macro-Scale Findings of the DebriSat Debris Field Obtained from X-Rays of the Catch Panels

The DebriSat project analyzes the debris from a hypervelocity impact test conducted on a 56 kg-simulated satellite target in 2014. Its purpose is to generate a comprehensive database of the size, mass, material, shape, and the radar and optical properties of fragments generated from orbital collisions of modern-built spacecraft. Three hundred ninety-one foam catch panels from the DebriSat test have been X-rayed to locate the particles within them for subsequent extraction and assessment. The data from the tens of thousands of extracted particles has heretofore been the focus of the debris assessment. The work presented here connects the X-ray sample location images to reconstruct the 3D distribution of the entire fragment cloud. Although some errors are inherent to the process, this 3D database is valuable for qualitative studies of size and energy distributions. Further, the 3D database can indicate the extent of bending or breaking of the fragments as they decelerated to full capture. By virtue of its full sphere perspective, the 3D database allows graphical insight to the physics of the collision and breakup. This 3D representation has been developed as a “point and click” graphical interface to retrieve the full data set on individual recovered and assessed fragments within the growing database. Overall, this macro-level screening technique has added enormous insight to the experiment in unexpected ways.

Allen, Anthony↗

High resolution stationary digital breast tomosynthesis using distributed carbon nanotube x-ray source array

Purpose: The purpose of this study is to investigate the feasibility of increasing the system spatial resolution and scanning speed of Hologic Selenia Dimensions digital breast tomosynthesis (DBT) scanner by replacing the rotating mammography x-ray tube with a specially designed carbon nanotube (CNT) x-ray source array, which generates all the projection images needed for tomosynthesis reconstruction by electronically activating individual x-ray sources without any mechanical motion. The stationary digital breast tomosynthesis (s-DBT) design aims to (i) increase the system spatial resolution by eliminating image blurring due to x-ray tube motion and (ii) reduce the scanning time. Low spatial resolution and long scanning time are the two main technical limitations of current DBT technology. Methods: A CNT x-ray source array was designed and evaluated against a set of targeted system performance parameters. Simulations were performed to determine the maximum anode heat load at the desired focal spot size and to design the electron focusing optics. Field emission current from CNT cathode was measured for an extended period of time to determine the stable life time of CNT cathode for an expected clinical operation scenario. The source array was manufactured, tested, and integrated with a Selenia scanner. An electronic control unit was developed to interface the source array with the detection system and to scan and regulate x-ray beams. The performance of the s-DBT system was evaluated using physical phantoms. Results: The spatially distributed CNT x-ray source array comprised 31 individually addressable x-ray sources covering a 30 angular span with 1 pitch and an isotropic focal spot size of 0.6 mm at full width at half-maximum. Stable operation at 28 kV(peak) anode voltage and 38 mA tube current was demonstrated with extended lifetime and good source-to-source consistency. For the standard imaging protocol of 15 views over 14, 100 mAs dose, and 2 x 2 detector binning, the projection resolution along the scanning direction increased from 4.0 cycles/mm [at 10% modulation-transfer-function (MTF)] in DBT to 5.1 cycles/mm in s-DBT at magnification factor of 1.08. The improvement is more pronounced for faster scanning speeds, wider angular coverage, and smaller detector pixel sizes. The scanning speed depends on the detector, the number of views, and the imaging dose. With 240 ms detector readout time, the s-DBT system scanning time is 6.3 s for a 15-view, 100 mAs scan regardless of the angular coverage. The scanning speed can be reduced to less than 4 s when detectors become faster. Initial phantom studies showed good quality reconstructed images. Conclusions: A prototype s-DBT scanner has been developed and evaluated by retrofitting the Selenia rotating gantry DBT scanner with a spatially distributed CNT x-ray source array. Preliminary results show that it improves system spatial resolution substantially by eliminating image blur due to x-ray focal spot motion. The scanner speed of s-DBT system is independent of angular coverage and can be increased with faster detector without image degration. The accelerated lifetime measurement demonstrated the long term stability of CNT x-ray source array with typical clinical operation lifetime over 3 years.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

H 2 Pc and pentacene on Cu(110)-(2×1)O: A combined STM and nc-AFM study

Scanning tunneling microscopy (STM) and non-contact atomic force microscopy (nc-AFM) with a CuO tip is used to investigate adsorption of metal-free phthalocyanine (H 2 Pc) and pentacene on the Cu(110)-(2×1)O striped-phase reconstructed surface. We show that the combination of STM and nc-AFM is necessary to reveal the detailed adsorption geometry, necessary for interpreting the observed STM contrast. Comparison of the nc-AFM images with simulations shows that some of the H 2 Pc molecules are deformed out-of-plane on this surface, while pentacene retains its molecular geometry regardless of adsorption site. Our research highlights how the stiffness of CuO tips makes it possible to probe the structure of organic semiconductor / metal interfaces.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Atomic-Scale Structure and Stress Release Mechanism in Core–Shell Nanoparticles

According to the article, core–shell nanoparticles find applications in catalysts, sensors, and theranostics. The full internal 3D atomic structure, however, cannot be resolved by current imaging and diffraction techniques. We analyzed the atomic positions and stress-release mechanism in a cubic Au–Pd core–shell nanoparticle in approximately 1000 times higher resolution than current experimental techniques using large-scale molecular dynamics simulation to overcome these limitations. The core–shell nanocube of 73 nm size was modeled similarly to solution synthesis by random epitaxial deposition of a 4 nm thick shell of Pd atoms onto a Au core of 65 nm side length using reliable interatomic potentials. The internal structure reveals specific deformations and stress relaxation mechanisms that are caused by the +4.8% lattice mismatch of gold relative to palladium and differential confinement of extended particle facets, edges, and corners by one, two, or three Au–Pd interfaces, respectively. The three-dimensional lattice strain causes long-range, arc-like bending of atomic rows along the faces and edges of the particle, especially near the Au–Pd interface, a bulging deformation of the Pd shell, and stacking faults in the Pd shell at the corners of the particle. The strain pattern and mechanism of stress release were further characterized by profiles of the atomic layer spacing in the principal crystallographic directions. Accordingly, strain in the Pd shell is several times larger in the extended facets than near the edges and corners of the nanoparticle, which likely affects adsorption, optical, and electrochemical properties. The findings are consistent with available experimental data, including 3D reconstructions of the same cubic nanoparticle by coherent diffractive imaging (CDI) and may be verified by more powerful experimental techniques in the future. The stress release mechanisms are representative for cubic core–shell nanoparticles with fcc structure and can be explored for different shapes by the same methods.

Chemistry↗

Cascading phase transformations in high carbon steel resulting in the formation of inverse bainite: An atomic scale investigation

Atom probe tomography (APT) has been implemented to understand the redistribution of solutes during the isothermal cascading phase transformations from supersaturated austenite resulting in the formation of inverse bainite. Different cascading reactions resulting in the formation of inverse bainite, namely the cementite midrib formation, ferrite formation, secondary cementite formation, and the degenerated microstructure of inverse bainite have been studied in detail. Solute profiles across the different transformation interfaces indicate Negligible Partitioning Local Equilibrium (NPLE) type growth kinetics for cementite midrib, whereas a transition in growth kinetics from Para Equilibrium (PE) to Negligible Partitioning Local Equilibrium (NPLE) is observed for secondary cementite and ferrite transformation. The results demonstrate a strong indication that the inverse bainitic transformation occurs as a consequence of individual cascading phase transformations starting from parent austenite, and the transformation of inverse bainite occurs in a similar manner to Widmanstatten ferrite/bainitic ferrite with carbon diffusion-controlled growth, and without any reconstructive or long-range diffusion of substitutional solutes.

36 MATERIALS SCIENCE↗

Real-time 3D analysis during electron tomography using tomviz

The demand for high-throughput electron tomography is rapidly increasing in biological and material sciences. However, this 3D imaging technique is computationally bottlenecked by alignment and reconstruction which runs from hours to days. We demonstrate real-time tomography with dynamic 3D tomographic visualization to enable rapid interpretation of specimen structure immediately as data is collected on an electron microscope. Using geometrically complex chiral nanoparticles, we show volumetric interpretation can begin in less than 10 minutes and a high-quality tomogram is available within 30 minutes. Real-time tomography is integrated into tomviz, an open-source and cross-platform 3D data analysis tool that contains intuitive graphical user interfaces (GUI), to enable any scientist to characterize biological and material structure in 3D.

36 MATERIALS SCIENCE↗

Transmission history of SARS-CoV-2 in humans and white-tailed deer

The emergence of a novel pathogen in a susceptible population can cause rapid spread of infection. High prevalence of SARS-CoV-2 infection in white-tailed deer ( Odocoileus virginianus ) has been reported in multiple locations, likely resulting from several human-to-deer spillover events followed by deer-to-deer transmission. Knowledge of the risk and direction of SARS-CoV-2 transmission between humans and potential reservoir hosts is essential for effective disease control and prioritisation of interventions. Using genomic data, we reconstruct the transmission history of SARS-CoV-2 in humans and deer, estimate the case finding rate and attempt to infer relative rates of transmission between species. We found no evidence of direct or indirect transmission from deer to human. However, with an estimated case finding rate of only 4.2%, spillback to humans cannot be ruled out. The extensive transmission of SARS-CoV-2 within deer populations and the large number of unsampled cases highlights the need for active surveillance at the human–animal interface.

60 APPLIED LIFE SCIENCES↗

Oxidation of GaSb(100) and its control studied by scanning tunneling microscopy and spectroscopy

Atomic-scale knowledge and control of oxidation of GaSb(100), which is a potential interface for energy-efficient transistors, are still incomplete, largely due to an amorphous structure of GaSb(100) oxides. We elucidate these issues with scanning-tunneling microscopy and spectroscopy. The unveiled oxidation-induced building blocks cause defect states above Fermi level around the conduction-band edge. By interconnecting the results to previous photoemission findings, we suggest that the oxidation starts with substituting second-layer Sb sites by oxygen. Adding small amount of indium on GaSb(100), resulting in a (4 × 2)-In reconstruction, before oxidation produces a previously unreported, crystalline oxidized layer of (1 × 3)-O free of gap states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Air-coupled acoustic radiation force for non-contact generation of broadband mechanical waves in soft media

A non-contact method for efficient, non-invasive excitation of mechanical waves in soft media is proposed, in which we focus an ultrasound (US) signal through air onto the surface of a medium under study. The US wave reflected from the air/medium interface provides radiation force to the medium surface that launches a transient mechanical wave in the transverse (lateral) direction. The type of mechanical wave is determined by boundary conditions. To prove this concept, a home-made 1 MHz piezo-ceramic transducer with a matching layer to air sends a chirped US signal centered at 1 MHz to a 1.6 mm thick gelatin phantom mimicking soft biological tissue. A phase-sensitive (PhS)-optical coherence tomography system is used to track/image the mechanical wave. The reconstructed transient displacement of the mechanical wave in space and time demonstrates highly efficient generation, thus offering great promise for non-contact, non-invasive characterization of soft media, in general, and for elasticity measurements in delicate soft tissues and organs in bio-medicine, in particular.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Real-Time Data Acquisition and Processing System for MHz Repetition Rate Image Sensors

An electro-optic detector is one of the diagnostic setups used in particle accelerators. It employs an electro-optic crystal to encode the longitudinal beam charge profile in the spectrum of a light pulse. The charge distribution is then reconstructed using data captured by a fast spectrometer. The measurement repetition rate should match or exceed the machine bunching frequency, which is often in the range of several MHz. A high-speed optical line detector (HOLD) is a linear camera designed for easy integration with scientific experiments. The use of modern FPGA circuits helps in the efficient collection and processing of data. The solution is based on Xilinx 7-Series FPGA circuits and implements a custom latency-optimized architecture utilizing the AXI4 family of interfaces. HOLD is one of the fastest line cameras in the world. Thanks to its hardware architecture and a powerful KALYPSO sensor from KIT, it outperforms the fastest comparable commercial devices.

MicroTCA↗

Effect of electrolyte composition on rock salt surface degradation in NMC cathodes during high-voltage potentiostatic holds

Surface degradation of lithium-ion cathodes at high voltages represents a significant barrier to increasing the useable energy of conventional cathodes. Though much work has been focused on mitigating the detrimental effects of such phenomena, the complex and correlated mechanisms involved have made progress difficult. Herein, the effect of electrolyte identity on surface degradation is examined. LiNi0.5Mn0.3Co0.2O2 (NMC532)/Li4Ti5O12 (LTO) full cells were constructed using three different electrolytes: a baseline organic carbonate electrolyte, a baseline organic carbonate electrolyte with an oxidizable additive, and a fluorinated carbonate electrolyte. Each system was subjected to a 60 h potentiostatic hold at 3.05 V (4.6 V vs. Li+/Li) and subsequently deconstructed for characterization via transmission electron microscopy (TEM) and electron energy loss spectroscopy (EELS). Molecular simulations were carried out on each distinct component of the three electrolytes in contact with crystal surfaces of an NMC532 particle. Results indicate an affinity for the additive-containing electrolyte to extract atomic oxygen from the cathode surface, whereas the fluorinated electrolyte components have negligible interactions. Hydrogen abstraction from the baseline electrolyte is facilitated by the NMC532 surface. TEM analysis of cathode surfaces, after the potentiostatic holds, revealed that the NMC532 particles cycled with the additive-containing electrolyte underwent significant surface degradation, including changes to local crystal structure in a region penetrating 20-40 nm from the surface; consistent with oxygen and lithium loss from the cathode material. However, the NMC532 in contact with the fluorinated electrolyte showed a disordered layer of just a few nm in thickness, similar to the depth of crystal disorder observed in pristine NMC532 primary particles. EELS data of the oxygen K-edge also indicated transition metal (TM) reduction, consistent with oxygen loss and changes in crystal structure extending into the cathode surface for each of the electrolytes surveyed. These surface reactions, including oxygen loss, are shown to correlate well with elevated oxidation currents and surface reconstructions of cathode particles.

cathode/electrolyte interface↗

Orion EFT-1 Catalytic Tile Experiment Overview and Flight Measurements

This paper describes the design and results of a surface catalysis flight experiment flown on the Orion Multipurpose Crew Vehicle during Exploration Flight Test 1 (EFT1). Similar to previous Space Shuttle catalytic tile experiments, the present test consisted of a highly catalytic coating applied to an instrumented TPS tile. However, the present catalytic tile experiment contained significantly more instrumentation in order to better resolve the heating overshoot caused by the change in surface catalytic efficiency at the interface between two distinct materials. In addition to collecting data with unprecedented spatial resolution of the "overshoot" phenomenon, the experiment was also designed to prove if such a catalytic overshoot would be seen in turbulent flow in high enthalpy regimes. A detailed discussion of the results obtained during EFT1 is presented, as well as the challenges associated with data interpretation of this experiment. Results of material testing carried out in support of this flight experiment are also shown. Finally, an inverse heat conduction technique is employed to reconstruct the flight environments at locations upstream and along the catalytic coating. The data and analysis presented in this work will greatly contribute to our understanding of the catalytic "overshoot" phenomenon, and have a significant impact on the design of future spacecraft.

Salazar, Giovanni↗

Facile hermetic TEM grid preparation for molecular imaging of hydrated biological samples at room temperature

Abstract Although structures of vitrified supramolecular complexes have been determined at near-atomic resolution, elucidating in situ molecular structure in living cells remains a challenge. Here, we report a straightforward liquid cell technique, originally developed for real-time visualization of dynamics at a liquid-gas interface using transmission electron microscopy, to image wet biological samples. Due to the scattering effects from the liquid phase, the micrographs display an amplitude contrast comparable to that observed in negatively stained samples. We succeed in resolving subunits within the protein complex GroEL imaged in a buffer solution at room temperature. Additionally, we capture various stages of virus cell entry, a process for which only sparse structural data exists due to their transient nature. To scrutinize the morphological details further, we used individual particle electron tomography for 3D reconstruction of each virus. These findings showcase this approach potential as an efficient, cost-effective complement to other microscopy technique in addressing biological questions at the molecular level.

59 BASIC BIOLOGICAL SCIENCES↗

Atomic layer deposition of crystalline SrHfO{sub 3} directly on Ge (001) for high-k dielectric applications

The current work explores the crystalline perovskite oxide, strontium hafnate, as a potential high-k gate dielectric for Ge-based transistors. SrHfO{sub 3} (SHO) is grown directly on Ge by atomic layer deposition and becomes crystalline with epitaxial registry after post-deposition vacuum annealing at ∼700 °C for 5 min. The 2 × 1 reconstructed, clean Ge (001) surface is a necessary template to achieve crystalline films upon annealing. The SHO films exhibit excellent crystallinity, as shown by x-ray diffraction and transmission electron microscopy. The SHO films have favorable electronic properties for consideration as a high-k gate dielectric on Ge, with satisfactory band offsets (>2 eV), low leakage current (<10{sup −5} A/cm{sup 2} at an applied field of 1 MV/cm) at an equivalent oxide thickness of 1 nm, and a reasonable dielectric constant (k ∼ 18). The interface trap density (D{sub it}) is estimated to be as low as ∼2 × 10{sup 12 }cm{sup −2 }eV{sup −1} under the current growth and anneal conditions. Some interfacial reaction is observed between SHO and Ge at temperatures above ∼650 °C, which may contribute to increased D{sub it} value. This study confirms the potential for crystalline oxides grown directly on Ge by atomic layer deposition for advanced electronic applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Monte Carlo-based treatment planning system calculation engine for microbeam radiation therapy

Purpose: Microbeam radiation therapy (MRT) is a synchrotron radiotherapy technique that explores the limits of the dose-volume effect. Preclinical studies have shown that MRT irradiations (arrays of 25-75-{mu}m-wide microbeams spaced by 200-400 {mu}m) are able to eradicate highly aggressive animal tumor models while healthy tissue is preserved. These promising results have provided the basis for the forthcoming clinical trials at the ID17 Biomedical Beamline of the European Synchrotron Radiation Facility (ESRF). The first step includes irradiation of pets (cats and dogs) as a milestone before treatment of human patients. Within this context, accurate dose calculations are required. The distinct features of both beam generation and irradiation geometry in MRT with respect to conventional techniques require the development of a specific MRT treatment planning system (TPS). In particular, a Monte Carlo (MC)-based calculation engine for the MRT TPS has been developed in this work. Experimental verification in heterogeneous phantoms and optimization of the computation time have also been performed. Methods: The penelope/penEasy MC code was used to compute dose distributions from a realistic beam source model. Experimental verification was carried out by means of radiochromic films placed within heterogeneous slab-phantoms. Once validation was completed, dose computations in a virtual model of a patient, reconstructed from computed tomography (CT) images, were performed. To this end, decoupling of the CT image voxel grid (a few cubic millimeter volume) to the dose bin grid, which has micrometer dimensions in the transversal direction of the microbeams, was performed. Optimization of the simulation parameters, the use of variance-reduction (VR) techniques, and other methods, such as the parallelization of the simulations, were applied in order to speed up the dose computation. Results: Good agreement between MC simulations and experimental results was achieved, even at the interfaces between two different media. Optimization of the simulation parameters and the use of VR techniques saved a significant amount of computation time. Finally, parallelization of the simulations improved even further the calculation time, which reached 1 day for a typical irradiation case envisaged in the forthcoming clinical trials in MRT. An example of MRT treatment in a dog's head is presented, showing the performance of the calculation engine. Conclusions: The development of the first MC-based calculation engine for the future TPS devoted to MRT has been accomplished. This will constitute an essential tool for the future clinical trials on pets at the ESRF. The MC engine is able to calculate dose distributions in micrometer-sized bins in complex voxelized CT structures in a reasonable amount of time. Minimization of the computation time by using several approaches has led to timings that are adequate for pet radiotherapy at synchrotron facilities. The next step will consist in its integration into a user-friendly graphical front-end.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three-Dimensional Reconstruction and Analysis of All-Solid Li-Ion Battery Electrode Using Synchrotron Transmission X-ray Microscopy Tomography

A synchrotron transmission X-ray microscopy tomography system with a spatial resolution of 58.2 nm at the Advanced Photon Source was employed to obtain three-dimensional morphological data of all-solid Li-ion battery electrodes. The three-phase electrode was fabricated from a 47:47:6 (wt %) mixture of Li(Ni 1/3 Mn 1/3 Co 1/3 )O 2 as active material, Li 1.3 Ti 1.7 Al 0.3 (PO 4 ) 3 as Li-ion conductor, and Super-P carbon as electron conductor. Furthermore, the geometric analysis show that particle-based all-solid Li-ion battery has serious contact interface problem which significantly impact the Li-ion transport and intercalation reaction in the electrode, leading to low capacity, poor rate capability and cycle life.

25 ENERGY STORAGE↗

Measurement of interfacial thermal resistance in high-energy-density matter

Heat transport across interfaces is a ubiquitous phenomenon with many unresolved aspects. In particular, it is unknown if an interfacial thermal resistance (ITR) occurs in matter with high-energy-density where free electrons dominate the heat conduction. Here, we report on the first experimental evidence that a significant heat barrier is present between two different regions of high-energy-density matter: a strongly heated tungsten wire and a surrounding plastic layer that stays relatively cold. We use diffraction-enhanced imaging to track the time evolution of density discontinuities and reconstruct the temperature evolution in the quasi-stationary stage. The clear signatures of a temperature jump demonstrate the importance of the ITR for strongly heated systems with far-reaching implications for interpreting experiments and applications like inertial confinement fusion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗