Search NASA⌕ Search

SEARCH · Search NASA

Results for “LABORATORY EQUIPMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Design of a free-space image-relay optical time-domain reflectometer to measure fiber-optic time delays at inertial confinement fusion relevant wavelengths

Fiber optics are an integral part of data collection, often used to transport visible and UV light to streaked spectrometers and photodetectors. Precisely measuring fiber-optic time delay (FOTD) is necessary for absolute data timing or fiber replacement. An optical time domain reflectometer (OTDR) can be used to measure the fiber-optic time delay. Commercial OTDR’s measure only the fiber in telecommunications wavelengths in the IR. To measure fibers at relevant wavelengths for inertial confinement fusion experiments, a solution using a free-space image relay was devised at the University of Rochester’s Laboratory for Laser Energetics (LLE), where readily available equipment has been used to measure the FOTD to within 2 ps at 526.5 nm as well as 351 nm, which is an order of magnitude better than the timing jitter between LLE’s Hardware Timing System and second-harmonic (526.5-nm) fiducial laser pulses.

47 OTHER INSTRUMENTATION↗

Fast Pyrolysis Process Development Unit for Validating Bench Scale Data

The purpose of this project was to prepare and operate a fast pyrolysis process development unit (PDU) that can validate experimental data generated at the bench scale. In order to do this, a biomass preparation system, a modular fast pyrolysis fluidized bed reactor, modular gas clean-up systems, and modular bio-oil recovery systems were designed and constructed. Instrumentation for centralized data collection and process control were integrated. The bio-oil analysis laboratory was upgraded with the addition of analytical equipment needed to measure C, H, O, N, S, P, K, and Cl. To provide a consistent material for processing through the fluidized bed fast pyrolysis reactor, the existing biomass preparation capabilities of the ISU facility needed to be upgraded. A stationary grinder was installed to reduce biomass from bale form to 5-10 cm lengths. A 25 kg/hr rotary kiln drier was installed. It has the ability to lower moisture content to the desired level of less than 20% wt. An existing forage chopper was upgraded with new screens. It is used to reduce biomass to the desired particle size of 2-25 mm fiber length. To complete the material handling between these pieces of equipment, a bucket elevator and two belt conveyors must be installed. The bucket elevator has been installed. The conveyors are being procured using other funding sources. Fast pyrolysis bio-oil, char and non-condensable gases were produced from an 8 kg/hr fluidized bed reactor. The bio-oil was collected in a fractionating bio-oil collection system that produced multiple fractions of bio-oil. This bio-oil was fractionated through two separate, but equally important, mechanisms within the collection system. The aerosols and vapors were selectively collected by utilizing laminar flow conditions to prevent aerosol collection and electrostatic precipitators to collect the aerosols. The vapors were successfully collected through a selective condensation process. The combination of these two mechanisms has created the ability to effectively fractionate the bio-oil into distinct fractions with improved characteristics. The fractions of bio-oil each contained different properties. Bio-oil properties that were improved included the energy content, water content, acid content and distribution of certain carbohydrates (levoglucosan and acetic acid). The improved properties that are associated with the fractionated bio-oil could allow bio-oil to be used in new markets, preferably without further upgrading. The decreased water and acid contents in the first four (of five) fractions could allow for easier upgrading of the bio-oil into transportation fuels or other valuable products. Char and solid particulate content of bio-oil must be minimized. Solid particulate can erode surfaces, leading to decreased equipment and component life and increased maintenance. Char can contribute to the instability of bio-oil by acting as a catalyst and causing secondary reactions. To continuously remove char from the pyrolysis reactor product stream, two cyclonic gas separators (cyclones) were designed and constructed. The design of the two gas cyclones was based on gas flow rate, particulate density, desired efficiency and desired pressure drop.

09 BIOMASS FUELS↗

Computer-Based Procedures for Field Workers in Nuclear Power Plants: Development of a Model of Procedure Usage and Identification of Requirements

The nuclear industry is constantly trying to find ways to decrease the human error rate, especially the human errors associated with procedure use. As a step toward the goal of improving procedure use performance, researchers, together with the nuclear industry, have been looking at replacing the current paper-based procedures with computer-based procedure systems. The concept of computer-based procedures is not new by any means; however most research has focused on procedures used in the main control room. Procedures reviewed in these efforts are mainly emergency operating procedures and normal operating procedures. Based on lessons learned for these previous efforts we are now exploring a more unknown application for computer based procedures - field procedures, i.e. procedures used by nuclear equipment operators and maintenance technicians. The Idaho National Laboratory and participants from the U.S. commercial nuclear industry are collaborating in an applied research effort with the objective of developing requirements and specifications for a computer-based procedure system to be used by field workers. The goal is to identify the types of human errors that can be mitigated by using computer-based procedures and how to best design the computer-based procedures to do so. This paper describes the development of a Model of Procedure Use and the qualitative study on which the model is based. The study was conducted in collaboration with four nuclear utilities and five research institutes. During the qualitative study and the model development requirements and for computer-based procedures were identified.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Low-Platinum Group (PGM) Metal Catalysts (Final Report)

High catalyst loadings and relatively high over-potential losses have limited the commercial viability of direct methanol fuel cells (DMFCs). Platinum-based catalysts are used in DMFCs with a loading of 4.5 mg cm-2; the catalyst layer is a significant contributor to the membrane electrode assembly (MEA) cost, which accounts for 60% of the system cost. The large-scale commercial viability of DMFCs is dependent on a significant (~50%) cost reduction. If these cost goals can be reached, the current market can be extended from 100's of units to 10,000's of units. Currently, Oorja is using a platinum-ruthenium catalyst for methanol oxidation, but does not have access to a supplier able to develop low-platinum group (PGM) metal catalysts to reach DMFC cost reduction targets. Oorja has recently developed a small lab scale capability in fabrication and testing of DMFC membrane electrode assemblies (MEAs), but does not have access to synthesis and characterization of advanced electrocatalysts. The materials, equipment, and expertise at the National Renewable Energy Laboratory (NREL) are of significant value to Oorja. NREL recently develop platinum-nickel nanowires as catalysts in hydrogen fuel cells. These materials have also shown promise in DMFC applications as a potential replacement for standard platinum-ruthenium catalysts; in ex-situ testing, these materials have shown one order of magnitude higher mass activity and can avoid ruthenium crossover contamination effects. These combined properties are exceptionally appealing to Oorja, and can result in significantly decreasing the capital costs of DMFCs.

30 DIRECT ENERGY CONVERSION↗

Imaging Intact Filamentous Fungi from Spore to Hyphal Tip on the Nanoscale

Previously, the Pacific Northwest National Laboratory was limited by a 3-order of magnitude gap in resolution for direct 2-D and 3-D imaging of chemical, biological, energy and materials science systems. Our imaging instrumentation could directly visualize 3-D ultrastructure without labeling at resolutions less than 10-nanometers or greater than 10-micrometers. To address this gap, we procured and commissioned a Sigray NanoFast Bio-Lambda laboratory-based x-ray nanotomography system. This equipment provides the capability to image through tens of micrometers of organic materials at down to 35-nanometer resolution to bridge the nanoscale to the mesoscale for biological systems, organic polymers, environmental and particulate samples.

47 OTHER INSTRUMENTATION↗

Sample Testing Basket: Design and Capabilities Report

SFR designs all require integral components that can withstand prolonged submersion in the liquid sodium primary coolant as well as in the gas space of the reactor vessel. Materials are often desired to withstand these conditions for the lifetime of the reactor. The Sample Testing Basket (STB) was designed and fabricated to meet the anticipated need for material exposure testing in prototypic reactor coolant environments; in the liquid sodium primary coolant and the sodium-vapor-laden gas space. Developed at Argonne National Laboratory (ANL), the STB is a piece of equipment designed for use in the Mechanisms Engineering Test Loop (METL) to allow for sodium exposure testing of materials within the METL facility.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Apollo Program Summary Report: Synopsis of the Apollo Program Activities and Technology for Lunar Exploration

Overall program activities and the technology developed to accomplish lunar exploration are discussed. A summary of the flights conducted over an 11-year period is presented along with specific aspects of the overall program, including lunar science, vehicle development and performance, lunar module development program, spacecraft development testing, flight crew summary, mission operations, biomedical data, spacecraft manufacturing and testing, launch site facilities, equipment, and prelaunch operations, and the lunar receiving laboratory. Appendixes provide data on each of the Apollo missions, mission type designations, spacecraft weights, records achieved by Apollo crewmen, vehicle histories, and a listing of anomalous hardware conditions noted during each flight beginning with Apollo 4.

Source record↗

Performance testing of the Galileo attitude control system

Performance testing plans, procedures, and initial results for the Galileo Attitude and Articulation Control Subsystem are described. The objectives of performance testing include test bed comparisons, examining the interactions between spacecraft dynamics and controllers, and verifying the ability to tune control algorithms in flight to meet specific performance requirements. Two primary test beds are described. One, the Integration Test Laboratory, drives actual flight hardware components and support equipment with a real time computer simulation of spacecraft dynamics. The other, the Functional Simulator, is a nonreal time computer simulation with high fidelity spacecraft dynamics, including flexible appendages, fuel slosh, and simulated hardware components. Initial Functional Simulator results are presented which illustrate spacecraft response to open loop spin-up and turn commands. A closed loop sun acquisition turn is also demonstrated. Future tests for verifying performance of attitude determination, spacecraft control, and scan platform pointing functions are outlined.

Bell, C. E.↗

Multiplex gas chromatography for use in space craft

Gas chromatography is a powerful technique for the analysis of gaseous mixtures. Some limitations in this technique still exist which can be alleviated with multiplex gas chromatography (MGC). In MGC, rapid multiple sample injections are made into the column without having to wait for one determination to be finished before taking a new sample. The resulting data must then be reduced using computational methods such as cross correlation. In order to efficiently perform multiplexgas chromatography, experiments in the laboratory and on board future space craft, skills, equipment, and computer software were developed. Three new techniques for modulating, i.e., changing, sample concentrations were demonstrated by using desorption, decomposition, and catalytic modulators. In all of them, the need for a separate gas stream as the carrier was avoided by placing the modulator at the head of the column to directly modulate a sample stream. Finally, the analysis of an environmental sample by multiplex chromatography was accomplished by employing silver oxide to catalytically modulate methane in ambient air.

Valentin, J. R.↗

Two Radiative/Thermochemical Instruments

Measurements of absorption and emission complement thermal measurements. Two laboratory instruments for research in combustion and pyrolysis equipped for radiative as well as thermal measurements. One instrument essentially differential scanning calorimeter (DSC) modified to detect radiation emitted by flames. Provides means to evaluate limits of flammability of materials exhibiting exothermic reactions in DSC's. Other instrument used to determine pyrolysis properties of specimens exposed to various gases by measurement of infrared absorption spectra of pyrolysis products.

Tapphorn, Ralph M.↗

But what will it Cost? The history of NASA cost estimating

Within two years of being chartered in 1958 as an independent agency to conduct civilian pursuits in aeronautics and space, NASA absorbed either wholly or partially the people, facilities, and equipment of several existing organizations. These included the laboratories of the National Advisory Committee of Aeronautics (NACA) at Langley Research Center in Virginia, Ames Research Center in California, and Lewis Research Center in Ohio; the Army Ballistic Missile Agency (ABMA) at Redstone Arsenal Alabama, for which the team of Wernher von Braun worked; and the Department of Defense Advanced Research Projects Agency (ARPA) and their ongoing work on big boosters. These were especially valuable resources to jump start the new agency in light of the shocking success of the Soviet space probe Sputnik in the autumn of the previous year and the corresponding pressure from an impatient American public to produce some response. Along with these inheritances, there came some existing systems engineering and management practices, including project cost estimating methodologies. This paper will briefly trace the origins of those methods and how they evolved within the agency over the past three decades.

Hamaker, Joseph W.↗

Virtual Reality Lab Assistant

Virtual Reality Lab Assistant (VRLA) demonstration model is aligned for engineering and material science experiments to be performed by undergraduate and graduate students in the course as a pre-lab simulation experience. This will help students to get a preview of how to use the lab equipment and run experiments without using the lab hardware/software equipment. The quality of the time available for laboratory experiments can be significantly improved through the use of virtual reality technology.

Saha, Hrishikesh↗

Cluster Inter-Spacecraft Communications

A document describes a radio communication system being developed for exchanging data and sharing data-processing capabilities among spacecraft flying in formation. The system would establish a high-speed, low-latency, deterministic loop communication path connecting all the spacecraft in a cluster. The system would be a wireless version of a ring bus that complies with the Institute of Electrical and Electronics Engineers (IEEE) standard 1393 (which pertains to a spaceborne fiber-optic data bus enhancement to the IEEE standard developed at NASA's Jet Propulsion Laboratory). Every spacecraft in the cluster would be equipped with a ring-bus radio transceiver. The identity of a spacecraft would be established upon connection into the ring bus, and the spacecraft could be at any location in the ring communication sequence. In the event of failure of a spacecraft, the ring bus would reconfigure itself, bypassing a failed spacecraft. Similarly, the ring bus would reconfigure itself to accommodate a spacecraft newly added to the cluster or newly enabled or re-enabled. Thus, the ring bus would be scalable and robust. Reliability could be increased by launching, into the cluster, spare spacecraft to be activated in the event of failure of other spacecraft.

Cox, Brian↗

Measurement Assurance for End-Item Users

The goal of a Quality Management System (QMS) as specified in ISO 9001 and AS9100 is to assure the end product meets specifications and customer requirements. Measuring devices, often called measuring and test equipments (MTE), provide the evidence of product conformity to the prescribed requirements. Therefore the processes which employ MTE can become a weak link to the overall QMS if proper attention is not given to development and execution of these processes. Traditionally, calibration of MTE is given more focus in industry standards and process control efforts than the equally important proper usage of the same equipment. It is a common complaint of calibration laboratory personnel that MTE users are only interested in "a sticker." If the QMS requires the MTE "to demonstrate conformity of the product," then the quality of the measurement process must be adequate for the task. This leads to an ad hoc definition; measurement assurance is a discipline that assures that all processes, activities, environments, standards, and procedures involved in making a measurement produce a result that can be rigorously evaluated for validity and accuracy. To evaluate that the existing measurement processes are providing an adequate level of quality to support the decisions based upon this measurement data, an understanding of measurement assurance basics is essential. This topic is complimentary to the calibration standard, ANSI/NCSL Z540.3-2006, which targets the calibration of MTE at the organizational level. This paper will discuss general measurement assurance when MTE is used to provide evidence of product conformity, therefore the target audience of this paper is end item users of MTE. A central focus of the paper will be the verification of tolerances and the associated risks, so calibration professionals may find the paper useful in communication with their customers, MTE users.

Mimbs, Scott M.↗

ENVIRONMENTAL SAMPLING USING LOCATION SPECIFIC AIR MONITORING IN BULK HANDLING FACILITIES

Since the introduction of safeguards strengthening measures approved by the International Atomic Energy Agency (IAEA) Board of Governors (1992-1997), international nuclear safeguards inspectors have been able to utilize environmental sampling (ES) (e.g. deposited particulates, air, water, vegetation, sediments, soil and biota) in their safeguarding approaches at bulk uranium/plutonium handling facilities. Enhancements of environmental sampling techniques used by the IAEA in drawing conclusions concerning the absence of undeclared nuclear materials or activities will soon be able to take advantage of a recent step change improvement in the gathering and analysis of air samples at these facilities. Location specific air monitoring feasibility tests have been performed with excellent results in determining attribute and isotopic composition of chemical elements present in an actual test-bed sample. Isotopic analysis of collected particles from an Aerosol Contaminant Extractor (ACE) collection, was performed with the standard bulk sampling protocol used throughout the IAEA network of analytical laboratories (NWAL). The results yielded bulk isotopic values expected for the operations. Advanced designs of air monitoring instruments such as the ACE may be used in gas centrifuge enrichment plants (GCEP) to detect the production of highly enriched uranium (HEU) or enrichments not declared by a State. Researchers at Savannah River National Laboratory in collaboration with Oak Ridge National Laboratory are developing the next generation of ES equipment for air grab and constant samples that could become an important addition to the international nuclear safeguards inspector's toolkit. Location specific air monitoring to be used to establish a baseline environmental signature of a particular facility employed for comparison of consistencies in declared operations will be described in this paper. Implementation of air monitoring will be contrasted against the use of smear ES when used during unannounced inspections, design information verification, limited frequency unannounced access, and complementary access visits at bulk handling facilities. Analysis of technical features required for tamper indication and resistance will demonstrate the viability of successful application of the system in taking ES within a bulk handling location. Further exploration of putting this technology into practice is planned to include mapping uranium enrichment facilities for the identification of optimal for installation of air monitoring devices.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗