Search NASA⌕ Search

SEARCH · Search NASA

Results for “LOCATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

A Novel Method to Incorporate the Spatial Location of the Lung Dose Distribution into Predictive Radiation Pneumonitis Modeling

Purpose: Studies have proposed that patients who receive radiation therapy to the base of the lung are more susceptible to radiation pneumonitis than patients who receive therapy to the apex of the lung. The primary purpose of the present study was to develop a novel method to incorporate the lung dose spatial information into a predictive radiation pneumonitis model. A secondary goal was to apply the method to a 547 lung cancer patient database to determine whether including the spatial information could improve the fit of our model. Methods and Materials: The three-dimensional dose distribution of each patient was mapped onto one common coordinate system. The boundaries of the coordinate system were defined by the extreme points of each individual patient lung. Once all dose distributions were mapped onto the common coordinate system, the spatial information was incorporated into a Lyman-Kutcher-Burman predictive radiation pneumonitis model. Specifically, the lung dose voxels were weighted using a user-defined spatial weighting matrix. We investigated spatial weighting matrices that linearly scaled each dose voxel according to the following orientations: superior-inferior, anterior-posterior, medial-lateral, left-right, and radial. The model parameters were fit to our patient cohort with the endpoint of severe radiation pneumonitis. The spatial dose model was compared against a conventional dose-volume model to determine whether adding a spatial component improved the fit of the model. Results: Of the 547 patients analyzed, 111 (20.3%) experienced severe radiation pneumonitis. Adding in a spatial parameter did not significantly increase the accuracy of the model for any of the weighting schemes. Conclusions: A novel method was developed to investigate the relationship between the location of the deposited lung dose and pneumonitis rate. The method was applied to a patient database, and we found that for our patient cohort, the spatial location does not influence the risk of pneumonitis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Impact of Extent and Location of Mediastinal Lymph Node Involvement on Survival in Stage III Non-Small Cell Lung Cancer Patients Treated With Definitive Radiotherapy

Purpose: Several surgical series have identified subcarinal, contralateral, and multilevel nodal involvement as predictors of poor overall survival in patients with Stage III non-small-cell lung cancer (NSCLC) treated with definitive resection. This retrospective study evaluates the impact of extent and location of mediastinal lymph node (LN) involvement on survival in patients with Stage III NSCLC treated with definitive radiotherapy. Methods and Materials: We analyzed 106 consecutive patients with T1-4 N2-3 Stage III NSCLC treated with definitive radiotherapy at University of Pennsylvania between January 2003 and February 2009. For this analysis, mediastinal LN stations were divided into four mutually exclusive groups: supraclavicular, ipsilateral mediastinum, contralateral mediastinum, and subcarinal. Patients' conditions were then analyzed according to the extent of involvement and location of mediastinal LN stations. Results: The majority (88%) of patients received sequential or concurrent chemotherapy. The median follow-up time for survivors was 32.6 months. By multivariable Cox modeling, chemotherapy use (hazard ratio [HR]: 0.21 [95% confidence interval (CI): 0.07-0.63]) was associated with improved overall survival. Increasing primary tumor [18F]-fluoro-2-deoxy-glucose avidity (HR: 1.11 [CI: 1.06-1.19]), and subcarinal involvement (HR: 2.29 [CI: 1.11-4.73]) were significant negative predictors of overall survival. On univariate analysis, contralateral nodal involvement (HR: 0.70 [CI: 0.33-1.47]), supraclavicular nodal involvement (HR: 0.78 [CI: 0.38-1.67]), multilevel nodal involvement (HR: 0.97 [CI: 0.58-1.61]), and tumor size (HR: 1.04 [CI: 0.94-1.14]) did not predict for overall survival. Patients with subcarinal involvement also had lower rates of 2-year nodal control (51.2% vs. 74.9%, p = 0.047) and 2-year distant control (28.4% vs. 61.2%, p = 0.043). Conclusions: These data suggest that the factors that determine oncologic outcome in Stage III NSCLC patients treated with definitive radiotherapy are distinct from those observed in patients who undergo surgical resection. The ultimate efficacy of radiation in locally advanced NSCLC is dependent on the intrinsic biology of the tumor.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

4π Noncoplanar Stereotactic Body Radiation Therapy for Centrally Located or Larger Lung Tumors

Purpose: To investigate the dosimetric improvements in stereotactic body radiation therapy for patients with larger or central lung tumors using a highly noncoplanar 4π planning system. Methods and Materials: This study involved 12 patients with centrally located or larger lung tumors previously treated with 7- to 9-field static beam intensity modulated radiation therapy to 50 Gy. They were replanned using volumetric modulated arc therapy and 4π plans, in which a column generation method was used to optimize the beam orientation and the fluence map. Maximum doses to the heart, esophagus, trachea/bronchus, and spinal cord, as well as the 50% isodose volume, the lung volumes receiving 20, 10, and 5 Gy were minimized and compared against the clinical plans. A dose escalation study was performed to determine whether a higher prescription dose to the tumor would be achievable using 4π without violating dose limits set by the clinical plans. The deliverability of 4π plans was preliminarily tested. Results: Using 4π plans, the maximum heart, esophagus, trachea, bronchus and spinal cord doses were reduced by 32%, 72%, 37%, 44%, and 53% (P≤.001), respectively, and R{sub 50} was reduced by more than 50%. Lung V{sub 20}, V{sub 10}, and V{sub 5} were reduced by 64%, 53%, and 32% (P≤.001), respectively. The improved sparing of organs at risk was achieved while also improving planning target volume (PTV) coverage. The minimal PTV doses were increased by the 4π plans by 12% (P=.002). Consequently, escalated PTV doses of 68 to 70 Gy were achieved in all patients. Conclusions: We have shown that there is a large potential for plan quality improvement and dose escalation for patients with larger or centrally located lung tumors using noncoplanar beams with sufficient quality and quantity. Compared against the clinical volumetric modulated arc therapy and static intensity modulated radiation therapy plans, the 4π plans yielded significantly and consistently improved tumor coverage and critical organ sparing. Given the known challenges in central structure dose constraints in stereotactic body radiation therapy to the lung, 4π planning may increase efficacy and reduce toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stereotactic Ablative Radiation Therapy for Centrally Located Early Stage or Isolated Parenchymal Recurrences of Non-Small Cell Lung Cancer: How to Fly in a “No Fly Zone”

Purpose: We extended our previous experience with stereotactic ablative radiation therapy (SABR; 50 Gy in 4 fractions) for centrally located non-small cell lung cancer (NSCLC); explored the use of 70 Gy in 10 fractions for cases in which dose-volume constraints could not be met with the previous regimen; and suggested modified dose-volume constraints. Methods and Materials: Four-dimensional computed tomography (4DCT)-based volumetric image-guided SABR was used for 100 patients with biopsy-proven, central T1-T2N0M0 (n=81) or isolated parenchymal recurrence of NSCLC (n=19). All disease was staged with positron emission tomography/CT; all tumors were within 2 cm of the bronchial tree, trachea, major vessels, esophagus, heart, pericardium, brachial plexus, or vertebral body. Endpoints were toxicity, overall survival (OS), local and regional control, and distant metastasis. Results: At a median follow-up time of 30.6 months, median OS time was 55.6 months, and the 3-year OS rate was 70.5%. Three-year cumulative actuarial local, regional, and distant control rates were 96.5%, 87.9%, and 77.2%, respectively. The most common toxicities were chest-wall pain (18% grade 1, 13% grade 2) and radiation pneumonitis (11% grade 2 and 1% grade 3). No patient experienced grade 4 or 5 toxicity. Among the 82 patients receiving 50 Gy in 4 fractions, multivariate analyses showed mean total lung dose >6 Gy, V{sub 20} >12%, or ipsilateral lung V{sub 30} >15% to independently predict radiation pneumonitis; and 3 of 9 patients with brachial plexus D{sub max} >35 Gy experienced brachial neuropathy versus none of 73 patients with brachial D{sub max} <35 Gy (P=.001). Other toxicities were analyzed and new dose-volume constraints are proposed. Conclusions: SABR for centrally located lesions produces clinical outcomes similar to those for peripheral lesions when normal tissue constraints are respected.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Influence of Fractionation Scheme and Tumor Location on Toxicities After Stereotactic Body Radiation Therapy for Large (≥5 cm) Non-Small Cell Lung Cancer: A Multi-institutional Analysis

Purpose: To describe the impact of fractionation scheme and tumor location on toxicities in stereotactic body radiation therapy (SBRT) for ≥5-cm non-small cell lung cancer (NSCLC), as part of a multi-institutional analysis. Methods: Patients with primary ≥5-cm N0 M0 NSCLC who underwent ≤5-fraction SBRT were examined across multiple high-volume SBRT centers. Collected data included clinical/treatment parameters; toxicities were prospectively assessed at each institution according to the Common Terminology Criteria for Adverse Events. Patients treated daily were compared with those treated every other day (QOD)/other nondaily regimens. Stratification between central and peripheral tumors was also performed. Results: Ninety-two patients from 12 institutions were evaluated (2004-2016), with median follow-up of 12 months. In total there were 23 (25%) and 6 (7%) grade ≥2 and grade ≥3 toxicities, respectively. Grades 2 and 3 pulmonary toxicities occurred in 9% and 4%, respectively; 1 patient treated daily experienced grade 5 radiation pneumonitis. Of the entire cohort, 46 patients underwent daily SBRT, and 46 received QOD (n=40)/other nondaily (n=6) regimens. Clinical/treatment parameters were similar between groups; the QOD/other group was more likely to receive 3-/4-fraction schemas. Patients treated QOD/other experienced significantly fewer grade ≥2 toxicities as compared with daily treatment (7% vs 43%, P<.001). Patients treated daily also had higher rates of grade ≥2 pulmonary toxicities (P=.014). Patients with peripheral tumors (n=66) were more likely to receive 3-/4-fraction regimens than those with central tumors (n=26). No significant differences in grade ≥2 toxicities were identified according to tumor location (P>.05). Conclusions: From this multi-institutional study, toxicity of SBRT for ≥5-cm lesions is acceptable, and daily treatment was associated with a higher rate of toxicities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Centroidal Voronoi tessellation based methods for optimal rain gauge location prediction

With more satellite and model precipitation data becoming available, new analytical methods are needed that can take advantage of emerging data patterns to make well informed predictions in many hydrological applications. Herein we propose a new strategy where we extract precipitation variability patterns and use correlation map to build the resulting density map that serves as an input to centroidal Voronoi tessellation construction that optimizes placement of precipitation gauges. We provide results of numerical experiments based on the data from the Alto-Adige region in Northern Italy and Oklahoma and compare them against actual gauge locations. This method provides an automated way for choosing new gauge locations and can be generalized to include physical constraints and to tackle other types of resource allocation problems.

54 ENVIRONMENTAL SCIENCES↗

Location of MTBE and toluene in the channel system of the zeolite mordenite: Adsorption and host-guest interactions

This paper reports a study of the location of Methyl Tertiary Butyl Ether (MTBE) and toluene molecules adsorbed in the pores of the organophylic zeolite mordenite from an aqueous solution. The presence of these organic molecules in the zeolite channels was revealed by structure refinement performed by the Rietveld method. About 3 molecules of MTBE and 3.6 molecules of toluene per unit cell were incorporated into the cavities of mordenite, representing 75% and 80% of the total absorption capacity of this zeolite. In both cases a water molecule was localized inside the side pocket of mordenite. The saturation capacity determined by the adsorption isotherms, obtained by batch experiments, and the weight loss given by thermogravimetric (TG) analyses were in very good agreement with these values. The interatomic distances obtained after the structural refinements suggest MTBE could be connected to the framework through a water molecule, while toluene could be bonded to framework oxygen atoms. The rapid and high adsorption of these hydrocarbons into the organophylic mordenite zeolite makes this cheap and environmental friendly material a suitable candidate for the removal of these pollutants from water. - graphical abstract: Location of MTBE (a) and toluene (b) in mordenite channels (projection along the [001] direction). Highlights: Black-Right-Pointing-Pointer We investigated the MTBE and toluene adsorption process into an organophilic zeolite mordenite. Black-Right-Pointing-Pointer The presence of MTBE and toluene in mordenite was determined by X-ray diffraction studies. Black-Right-Pointing-Pointer About 3 molecules of MTBE and 3.6 molecules of toluene per unit cell were incorporated into the zeolite cavities. Black-Right-Pointing-Pointer MTBE is connected to the framework through a water molecule. Black-Right-Pointing-Pointer Toluene is directly bonded to framework oxygen atoms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dosimetric errors during treatment of centrally located lung tumors with stereotactic body radiation therapy: Monte Carlo evaluation of tissue inhomogeneity corrections

Early experience with stereotactic body radiation therapy (SBRT) of centrally located lung tumors indicated increased rate of high-grade toxicity in the lungs. These clinical results were based on treatment plans that were computed using pencil beam–like algorithms and without tissue inhomogeneity corrections. In this study, we evaluated the dosimetric errors in plans with and without inhomogeneity corrections and with planning target volumes (PTVs) that were within the zone of the proximal bronchial tree (BT). For 10 patients, the PTV, lungs, and sections of the BT either inside or within 2 cm of the PTV were delineated. Two treatment plans were generated for each patient using the following dose-calculation methods: (1) pencil beam (PB) algorithm without inhomogeneity correction (IC) (PB − IC) and (2) PB with inhomogeneity correction (PB + IC). Both plans had identical beam geometry but different beam segment shapes and monitor units (MU) to achieve similar conformal dose coverage of PTV. To obtain the baseline dose distributions, each plan was recalculated using a Monte Carlo (MC) algorithm by keeping MUs the same in the respective plans. The median maximum dose to the proximal BT and PTV dose coverage in the PB + IC plans were overestimated by 8% and 11%, respectively. However, the median maximum dose to the proximal BT and PTV dose coverage in PB − IC plans were underestimated by 15% and 9%. Similar trends were observed in low-dose regions of the lung within the irradiated volume. Our study indicates that dosimetric bias introduced by unit tissue density plans cannot be characterized as underestimation or overestimation of dose without taking the tumor location into account. This issue should be considered when analyzing clinical toxicity data from early lung SBRT trials that utilized unit tissue density for dose calculations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Influence of tumor location on the intensity-modulated radiation therapy plan of helical tomotherapy

Given the design of the Helical TomoTherapy device, the patient's central axis is routinely aligned with the machine's rotational axis to prevent the patient's body from colliding with the machine walls. However, for treatment of tumors located away from the patient's central axis, this position may not be optimal as the adequate radiation dose may not reach the affected site. Our study aimed to investigate the influence of tumor location on dose quality and delivery efficiency of tomotherapy plans. A phantom and 15 patients were selected for this study. Two plans, A and B, were implemented for each case. In plan A, the patient's central axis was aligned with the machine's rotational axis, whereas in plan B, the center of the planning target volume (PTV) was aligned with the machine's rotational axis. Both plans were optimized with the same planning parameters, and the dose quality of the plans was evaluated using dosimetrics. The delivery efficiency was determined from delivery time and monitor units (MUs). A paired t-test or nonparametric Wilcoxon signed-rank test was performed for statistical comparison. In the phantom study, the median delivery times were 358 and 336 seconds for plans A and B, respectively, and this difference was significant (p = 0.005). In the patient study, the median delivery times were 348 and 317 seconds for plans A and B, respectively, and this difference was also significant (p = 0.001). The dose qualities of both plans for each patient were nearly identical. No significant differences were found in the conformal index, heterogeneity index, and mean dose delivered to normal tissue between the plans. Both phantom and patient studies showed that for normal-sized patients, the delivery time reduced as the distance between the PTV and the patient's central axis increased when the PTV center was aligned with the machine axis. In conclusion, aligning the PTV center with the machine's rotational axis by shifting the patient during tomotherapy reduces the delivery time without compromising the dose quality of intensity-modulated radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of a Thermo Scientific D711 D-T neutron generator located in a low-scatter facility

A dosimetry experiment used to measure the neutron flux and spectrum of a D-T neutron generator is presented. The D-T generator at Pacific Northwest National Laboratory is installed in the middle of a large room to minimize scatter of neutrons back to the sample. The efficacy of maintaining a pure fast neutron field for the sample is investigated. Twenty-one positions within 13 cm of the neutron source contained foils or wires of Fe, Ni, Al with additional Au, and In monitors at some locations. Spectral adjustment of the neutron flux at each position based on measured reaction rates and theoretical Monte Carlo calculations show that at least 99.1% of the spectrum lies above 110 keV for all measured positions, and neutrons above 14 MeV can account for as much as 91% at locations along the axis of the generator and close to the source. The 14 MeV component drops to 77% in radial positions far from the source. The largest total flux observed was 8.29E+08 n/cm2-s (±1.4%) in the center of the cooling cap, although additional experiments have shown this value could be as high as 1.20E+09 n/cm2-s.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of potato virus X replicase and TGBp3 subcellular locations

Potato virus X (PVX) infection leads to certain cytopathological modifications of the host endomembrane system. The subcellular location of the PVX replicase was previously unknown while the PVX TGBp3 protein was previously reported to reside in the ER. Using PVX infectious clones expressing the green fluorescent protein reporter, and antisera detecting the PVX replicase and host membrane markers, we examined the subcellular distribution of the PVX replicase in relation to the TGBp3. Confocal and electron microscopic observations revealed that the replicase localizes in membrane bound structures that derive from the ER. A subset of TGBp3 resides in the ER at the same location as the replicase. Sucrose gradient fractionation showed that the PVX replicase and TGBp3 proteins co-fractionate with ER marker proteins. This localization represents a region where both proteins may be synthesized and/or function. There is no evidence to indicate that either PVX protein moves into the Golgi apparatus. Cerulenin, a drug that inhibits de novo membrane synthesis, also inhibited PVX replication. These combined data indicate that PVX replication relies on ER-derived membrane recruitment and membrane proliferation.

60 APPLIED LIFE SCIENCES↗

Decision support system for the optimal location of electrical and electronic waste treatment plants: A case study in Greece

Environmentally sound end-of-life management of Electrical and Electronic Equipment has been realised as a top priority issue internationally, both due to the waste stream's continuously increasing quantities, as well as its content in valuable and also hazardous materials. In an effort to manage Waste Electrical and Electronic Equipment (WEEE), adequate infrastructure in treatment and recycling facilities is considered a prerequisite. A critical number of such plants are mandatory to be installed in order: (i) to accommodate legislative needs, (ii) decrease transportation cost, and (iii) expand reverse logistics network and cover more areas. However, WEEE recycling infrastructures require high expenditures and therefore the decision maker need to be most precautious. In this context, special care should be given on the viability of infrastructure which is heavily dependent on facilities' location. To this end, a methodology aiming towards optimal location of Units of Treatment and Recycling is developed, taking into consideration economical together with social criteria, in an effort to interlace local acceptance and financial viability. For the decision support system's needs, ELECTRE III is adopted as a multicriteria analysis technique. The methodology's applicability is demonstrated with a real-world case study in Greece.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Resonant X-ray Diffraction Reveals the Location of Counterions in Doped Organic Mixed Ionic Conductors

Organic mixed ionic–electronic conductors (OMIECs) have the potential to enable diverse new technologies, ranging from novel in situ biosensors to flexible energy storage devices and neuromorphic computing platforms. However, their complex behavior in functional films involving electrolyte-induced swelling, ion ingress, and electrochemical doping inhibits rational material design. Of critical importance is an understanding of the specific location of the ions in the volumetrically doped material, yet this information is not readily available. Here, in this report, we present the use of grazing- incidence resonant X-ray diffraction (RXRD, also known as anomalous diffraction) at S and Cl K-edges to determine the structure of a doped, prototypical, semicrystalline polymer OMIEC based on oligo(ethylene glycol) substitution of regioregular polythiophene. The RXRD measurement provides two key insights. Quantitative analysis of the RXRD allows the determination of the position of the ion relative to the polymer backbone in the crystalline regions. We find that the anion is relatively distant from the backbone, nearer to the lamella mid-plane naively in conflict with expected Coulombic attraction between the ion and the doped polymer polaron. Comparison of RXRD to Cl – fluorescence (total Cl – ) allows determination of the relative order of doping between the crystalline and amorphous regions. We find preferential doping of the crystalline regions. Both insights, the preferential doping of crystals at low potential and the specific location of the counterion with respect to the polymer backbone, are critical to developing a microscopic understanding of transport in OMIECs.

36 MATERIALS SCIENCE↗

Spectroscopic Signature of Proton Location in Proton Bound HSO4-•H+•X- (X = F, Cl, Br, and I) Clusters

Proton transfer plays a vital role in a variety of chemical and biological processes. The proton location in proton bound clusters, specifically, in the anions of HSO4?•H+•X? (X = F, Cl, Br, and I), has been studied by negative ion photoelectron spectroscopy and ab initio theoretical calculations. The measured photoelectron spectra of HSO4?•H+•X? (X = Cl, Br, and I) closely resemble those of X? by simply shifting to higher electron binding energies, suggesting that X? is the chromophore of the electron photodetachment, a fact clearly violating gas-phase acidity predictions. However, in the X = F case, the spectrum of HSO4?•H+•F? is more similar to that of HSO4?, indicating that H+ stays with F? and the HSO4? moiety carries the extra electron. Accompanying theoretical analyses are in excellent agreement with the experimental measurements and observations. This work provides direct spectroscopic evidence of the proton locations, clearly showing cases in which proton affinities of the constituent bases cannot correctly predict the right chemistry involving proton transfer processes.

Hou, Gao-Lei↗

Discovery of native metal ion sites located on the ferredoxin docking side of photosystem I.

Photosystem I (PSI) is a large membrane protein that catalyzes light-driven electron transfer across the thylakoid membrane from plastocyanin located in the lumen to ferredoxin in the stroma. Metal analysis reveals that PSI isolated from the cyanobacterial membranes of Synechococcus leopoliensis has a near-stoichiometric 1 molar equiv of Zn2+ per PSI monomer and two additional surface metal ion sites that favor Cu2+ binding. Two-dimensional hyperfine sublevel correlation (HYSCORE) spectroscopy reveals coupling to the so-called remote nitrogen of a single histidine coordinated to one of the Cu2+ centers. EPR and X-ray absorption fine structure (XAFS) studies of 2Cu?PSI complexes reveal the direct interaction of ferredoxin with the Cu2+ centers on PSI, establishing the location of native metal sites on the ferredoxin docking side of PSI. On the basis of these spectroscopic results and previously reported site-directed mutagenesis studies, inspection of the PSI crystal structure reveals a cluster of three highly conserved residues, His(D95), Glu(D103), and Asp(C23), as a likely Cu2+ binding site. The discovery of surface metal sites on the acceptor side of PSI provides a unique opportunity to probe the stromal region of PSI and the interactions of PSI with its reaction partner, the soluble electron carrier protein ferredoxin.

36 MATERIALS SCIENCE↗

Tocopherol Activity Correlates with its Location in a Membrane: A New Perspective on the Anti-Oxidant Vitamin E

We show evidence of an antioxidant mechanism for vitamin E which correlates strongly with its physical location in a model lipid bilayer. This data addresses the overlooked problem of the physical distance between the vitamin's reducing hydrogen and lipid acyl chain radicals. Our combined data from neutron diffraction, NMR and UV spectroscopy experiments, all suggest that reduction of reactive oxygen species and lipid radicals occurs specifically at the membrane's hydrophobic-hydrophilic interface. The latter is possible when the acyl chain snorkels to the interface from the hydrocarbon matrix. Moreover, not all model lipids are equal in this regard, as indicated by the small differences in vitamin's location. The present result is a clear example of the importance of lipid diversity in controlling the dynamic structural properties of biological membranes. Importantly, our results suggest that measurements of aToc oxidation kinetics, and its products, should be revisited by taking into consideration the physical properties of the membrane in which the vitamin resides.

Marquardt, Drew↗

Preferential Location of Germanium in the UTL and IPC-2a Zeolites

The preferential location of Ge in the double four-membered (D 4 R) rings of UTL has been examined with periodic density functional theory calculations. In silicate UTL, Ge atoms are preferentially sited at T1 and T2, the atoms in the D 4 R cages. Overall, the preference for siting Ge atoms in UTL depends strongly on the average T-O T angles centered at each site. The sites in the D 4 R cages have the lowest average T-O-T angles. Also, the preference for siting Ge atoms at the D 4 R sites in UTL increases as more Si atoms are replaced by Ge. Our calculations show that at least 3 Ge atoms can be located in the D 4 R cages before any appreciable occupancy at non-D 4 R sites. As a result, comparison of Ge atom siting in UTL to IPC-2a shows that the single four-membered ring (S 4 R) sites in the latter are not the most favorable sites.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impact of Distinct Origin Locations on the Life Cycles of Landfalling Atmospheric Rivers Over the U.S. West Coast

An atmospheric river (AR) event represents strong poleward moisture transport and is defined as a series of spatiotemporally connected instantaneous AR objects. Utilizing an AR tracking algorithm with a depth-first search (a widely used algorithm in computer science), we examine the life cycle characteristics of AR events that make landfall over the U.S. West Coast by their distinct origin locations. We report landfalling AR events from the Northwest Pacific (120°E–170°W, WLAR events) temporally last longer (5.3 versus 3.6 days on average) and have stronger intensity of integrated vapor transport (508 versus 388 kg m -1 s -1 on average) than those originating from the Northeast Pacific (125°W–170°W, ELAR events). A persistent tripole geopotential height anomaly pattern over the North Pacific modulates the origin locations and propagation of landfalling AR events. WLAR events are associated with anomalous highs over northeastern Asia and the Northeast Pacific and an anomalous low over the central North Pacific. This pattern provides favorable conditions for WLAR events to start, propagate northeastward, and make landfall in the northwestern West Coast. WLAR events contribute approximately 25% of the total winter precipitation over Washington and British Columbia. ELAR events are associated with a similar tripole pattern to the WLAR events with an eastward shift. The anomalous low over the Northeast Pacific helps ELAR events to start, propagate northeastward, and make landfall in the southwestern West Coast. Precipitation induced by ELAR events contributes up to 30% of total winter precipitation over California.

54 ENVIRONMENTAL SCIENCES↗