Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linear mixed models”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

AB INITIO EQUATIONS OF STATE FOR HYDROGEN (H-REOS.3) AND HELIUM (He-REOS.3) AND THEIR IMPLICATIONS FOR THE INTERIOR OF BROWN DWARFS

We present new equations of state (EOSs) for hydrogen and helium covering a wide range of temperatures from 60 K to 10{sup 7} K and densities from 10{sup –10} g cm{sup –3} to 10{sup 3} g cm{sup –3}. They include an extended set of ab initio EOS data for the strongly correlated quantum regime with an accurate connection to data derived from other approaches for the neighboring regions. We compare linear mixing isotherms based on our EOS tables with available real mixture data. A first important astrophysical application of this new EOS data is the calculation of interior models for Jupiter and comparison with recent results. Second, mass-radius relations are calculated for Brown Dwarfs (BDs) which we compare with predictions derived from the widely used EOS of Saumon, Chabrier, and van Horn. Furthermore, we calculate interior models for typical BDs with different masses, namely, Corot-3b, Gliese-229b, and Corot-15b, and the giant planet KOI-889b. The predictions for the central pressures and densities differ by up to 10% dependent on the EOS used. Our EOS tables are made available in the supplemental material of this paper.

79 ASTRONOMY AND ASTROPHYSICS↗

The Scale and Activity of Symmetric Instability Estimated from a Global Submesoscale-Permitting Ocean Model

Abstract Symmetric instability (SI) extracts kinetic energy from fronts in the surface mixed layer (SML), potentially affecting the SML structure and dynamics. Here, a global submesoscale-permitting ocean model named MITgcm LLC4320 simulation is used to examine the Stone linear prediction of the maximum SI scale to estimate grid spacings needed to begin resolving SI. Furthermore, potential effects of SI on the usable wind work are estimated roughly: this estimate of SI “activity” is useful for assessing if these modes should be resolved or parameterized. The maximum SI scale varies by latitude with median values from 568 to 23 m. Strong seasonality is observed in the SI scale and activity. The median scale in winter is 188 m globally, 2.5 times of that of summer (75 m). SI is more active in winter: 15% of the time compared with 6% in summer. The strongest SI activity is found in the western Pacific, western Atlantic, and Southern Oceans. The required grid spacings for a global model to begin resolving SI eddies in the SML are 24 m (50% of regions resolved) and 7.9 m (90%) in winter, decreasing to 9.4 m (50%) and 3.6 m (90%) in summer. It is also estimated that SI may reduce usable wind work by an upper bound of 0.83 mW m −2 globally, or 5% of the global magnitude. The sensitivity of these estimates to empirical thresholds is provided in the text.

Dong, Jihai↗

Global energy balance simulations of shattered pellet injection

The dynamics of shattered pellet injection (SPI) shutdowns are simulated using a time-dependent global energy balance model, based on a modification of the KPRAD framework. The new SPI particle source in the model calculates the ablation of individual pellet fragments that enter the plasma as a temporally resolved plume, thus capturing the effects of earlier fragments on the ablation of those that follow, which has a significant impact on the overall assimilation. Despite the reduced physics and the global averaging of all quantities, results from a large number of DIII-D, KSTAR, and JET experiments are well reproduced, including the plasma cooling timescales, particle assimilation, and current quench (CQ) rates. Cooling timescales and CQ rates are in good agreement for pellets containing as little as ∼1% neon, while particle assimilations are most accurate for neon fractions above ∼15% by number of atoms. Below this, the assimilation tends to be overestimated due to the lack of radial transport in the particle balance, which becomes important in the low-Z limit. Predictive simulations of mixed-composition dual-SPI shutdowns in ITER are compared against those with the 3D non-linear magnetohydrodynamic code JOREK and are found to reproduce overall trends observed in the higher-fidelity modeling across a range of injection scenarios. The general success of the model points to the critical role of energy balance in determining SPI particle assimilation and the subsequent disruption dynamics and highlights the value of these simulations for experimental interpretation and for optimizing the deployment of computationally expensive, higher-fidelity models.

energy balance model↗

Site demonstration and performance evaluation of MPC for a large chiller plant with TES for renewable energy integration and grid decarbonization

Thermal energy storage (TES) for a cooling plant is a crucial resource for load flexibility. Traditionally, simple, heuristic control approaches, such as the storage priority control which charges TES during the nighttime and discharges during the daytime, have been widely used in practice, and shown reasonable performance in the past benefiting both the grid and the end-users such as buildings and district energy systems. However, the increasing penetration of renewables changes the situation, exposing the grid to a growing duck curve, which encourages the consumption of more energy in the daytime, and volatile renewable generation which requires dynamic planning. The growing pressure of diminishing greenhouse gas emissions also increases the complexity of cooling TES plant operations as different control strategies may apply to optimize operations for energy cost or carbon emissions. This paper presents a model predictive control (MPC), site demonstration and evaluation results of optimal operation of a chiller plant, TES and behind-meter photovoltaics for a campus-level district cooling system. The MPC was formulated as a mixed-integer linear program for better numerical and control properties. Compared with baseline rule-based controls, the MPC results show reductions of the excess PV power by around 25%, of the greenhouse gas emission by 10%, and of peak electricity demand by 10%.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Study on Feasibility of Dual-Wavelength Radar for Identification of Hydrometeor Phases

An important objective for the Dual-wavelength Ku-/Ka-band Precipitation Radar (DPR) that will be on board the Global Precipitation Measuring (GPM) core satellite, is to identify the phase state of hydrometeors along the range direction. To assess this, radar signatures are simulated in snow and rain to explore the relation between the differential frequency ratio (DFR), defined as the difference of radar reflectivity factors between Ku- and Ka-bands, and the radar reflectivity factor at Ku-band, ZKu, for different hydrometeor types. Model simulations indicate that there is clear separation between snow and rain in the ZKu-DFR plane assuming that the snow follows the Gunn-Marshall size distribution (1958) and rain follows the Marshall-Palmer size distribution (1948). In an effort to verify the simulated results, the data collected by the Airborne Second Generation Precipitation Radar (APR-2) in the Wakasa Bay AMSR-E campaign are employed. Using the signatures of Linear Depolarization Ratio (LDR) at Ku-band, the APR-2 data can be easily divided into the regions of snow, mixed phase and rain for stratiform storms. These results are then superimposed onto the theoretical curves computed from the model in the ZKu-DFR plane. It has been found that in 90% of the cases, snow and rain can be distinguished if the Ku-band radar reflectivity exceeds 18 dBZ (the minimum detectable level of GPM DPR at Ku-band). This is also the case for snow and mixed-phase hydrometeors. Although snow can be easily distinguished from rain and melting hydrometeors by using Ku- and Ka-band radar, the rain and mixed-phase particles are not always separable. It is concluded that Ku- and Ka-band dual-wavelength radar might provide a potential means to identify the phase state of hydrometeors.

Liao, Liang↗

Optimal Network Topology for Node-Breaker Representations With AC Power Flow Constraints

It has been demonstrated that network topology optimization (NTO) may change the topology of power system networks, and consequently, provide additional flexibility to reduce network congestion and violations. Most NTO problems are formulated based on the bus-branch model in which it is challenging to represent a realistic picture of all substation configurations. In this paper, we explore advantages of substation reconfiguration modeling based on node-breaker representations for NTO problem with full nonlinear alternating current power flow. It also proposes a tailored solution algorithm to solve this nonconvex mixed-integer nonlinear programming through the outer approximation method. The proposed solution approach iterates between a mixed-integer linear programming and a nonlinear subproblem. Additional enhancements to further accelerate the iteration process are illustrated. Numerical case studies demonstrate the relative economic and operational impact of optimal network topology with node-breaker representations.

42 ENGINEERING↗

A Stochastic Multi-Commodity Logistic Model for Disaster Preparation in Distribution Systems

In this paper, we propose a stochastic optimization approach for disaster preparation in distribution systems. For an upcoming storm, utilities should have a preparation plan that includes warehousing restoration supplies, securing staging sites (depots), and prepositioning crews and equipment. Pre-storm planning enables faster and more efficient post-disaster deploy ment of crews and equipment resources to damage locations. To assist utilities in making this important preparation, this paper develops a two-stage stochastic mixed integer linear program. The first stage determines the depots, number of crews in each site, and the amount of equipment. The second stage is the recourse action that deals with acquiring new equipment and assigning crews to repair damages in realized scenarios. The objective of the developed model is to minimize the costs of depots, crews, equipment, and penalty costs associated with delays in obtain ing equipment and restoration. We consider the uncertainties of damaged lines, number and type of equipment required, and expected repair times. The model is validated on modified IEEE 123-bus distribution test system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An ℓ 0 ℓ 2 -norm regularized regression model for construction of robust cluster expansions in multicomponent systems

In this work we introduce ℓ 0 ℓ 2 -norm regularization and hierarchy constraints into linear regression for the construction of cluster expansions to describe configurational disorder in materials. The approach is implemented through mixed integer quadratic programming (MIQP). The ℓ 2 -norm regularization is used to suppress intrinsic data noise, while the ℓ 0 -norm is used to penalize the number of nonzero elements in the solution. The hierarchy relation between clusters imposes relevant physics and is naturally included by the MIQP paradigm. As such, sparseness and cluster hierarchy can be well optimized to obtain a robust, converged set of effective cluster interactions with improved physical meaning. We demonstrate the effectiveness of ℓ 0 ℓ 2 -norm regularization in two high-component disordered rocksalt cathode material systems, where we compare the cross-validation, convergence speed, and the reproduction of phase diagrams, voltage profiles, and Li-occupancy energies with those of the conventional ℓ 1 -norm regularized cluster expansion models.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Flexible dynamic boundary microgrid operation considering network and load unbalances

Flexible microgrids with dynamic boundaries have recently been introduced in the literature. With the ability to reconfigure the topology of the microgrids dynamically through remotely controlled switches, flexible microgrids with dynamic boundaries can further improve the resiliency and energy efficiency of microgrids with distributed energy resources (DERs). This paper focuses on the optimal operation considering one of the predominant characteristics of microgrids and distribution systems – unbalanced networks and loads. In existing literature, balanced modeling of microgrids is more common due to its attractive simplicity. The three-phase power unbalance has not been considered as a constraint on the generation units in a microgrid. Further, negative sequence constraints have also been neglected. In this article, we propose a set of constraints that is specifically related to the capabilities of inverter interfaced resources to supply unbalanced current/power when the microgrid is islanded from the main distribution grid. We incorporate the new set of constraints into two optimization formulations leveraging two convex relaxations of the three-phase power flow equations: mixed-integer linear programming (MILP) and mixed-integer semidefinite programming (MISDP) that optimize the dispatch of controllable switches and DERs in the microgrid. The algorithms are then extended to networked microgrids with grid-forming sources. We test the algorithms on a realistic community microgrid model in Puerto Rico as well as standardized IEEE distribution test feeders. The testing results demonstrate the performance of the proposed algorithms. The MILP is fast and scalable, and the MISDP enforces the negative sequence voltage constraints.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-parametric analysis for mixed integer linear programming: An application to transmission upgrade and congestion management

Upgrading the capacity of existing transmission lines is essential for meeting the growing energy demands, facilitating the integration of renewable energy, and ensuring the security of the transmission system. This study focuses on the selection of lines whose capacities and by how much should be expanded from the perspective of the Independent System Operators (ISOs) to minimize the total system cost. We employ advanced multi-parametric programming and an enhanced branch-and-bound algorithm to address complex mixed-integer linear programming (MILP) problems, considering multi-period time constraints and physical limitations of generators and transmission lines. To characterize the various decisions in transmission expansion, we model the increased capacity of existing lines as parameters within a specified range. This study first relaxes the binary variables to continuous variables and applies the Lagrange method and Karush-Kuhn-Tucker (KKT) conditions to obtain optimal solutions and identify critical regions associated with active and inactive constraints. Moreover, we extend the traditional branch-and-bound (B&B) method by determining the problem’s upper and lower bounds at each node of the B&B decision tree, helping to manage computational challenges in large-scale MILP problems. Here, we compare the difference between the upper and lower bounds to obtain an approximate optimal solution within the decision-makers’ tolerable error range. In addition, the first derivative of the objective function on the parameters of each line is used to inform the selection of lines for easing congestion and maximizing social welfare. Finally, the capacity upgrades are selected by weighing the reductions in system costs against the expense of upgrading line capacities. The findings are supported by numerical simulations and provide transmission-line planners with decision-making guidance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stability Assessment of a System Comprising a Single Machine and Inverter with Scalable Ratings

Synchronous machines have traditionally acted as the foundation of large-scale electrical infrastructures and their physical properties have formed the cornerstone of system operations. However, with the increased integration of distributed renewable resources and energy-storage technologies, there is a need to systematically acknowledge the dynamics of power-electronics inverters - the primary energy-conversion interface in such systems - in all aspects of modeling, analysis, and control of the bulk power network. In this paper, we assess the properties of coupled machine-inverter systems by studying an elementary system comprised of a synchronous generator, three-phase inverter, and a load. The inverter model is formulated such that its power rating can be scaled continuously across power levels while preserving its closed-loop response. Accordingly, the properties of the machine-inverter system can be assessed for varying ratios of machine-to-inverter power ratings. After linearizing the model and assessing its eigenvalues, we show that system stability is highly dependent on the inverter current controller and machine exciter, thus uncovering a key concern with mixed machine-inverter systems and motivating the need for next-generation grid-stabilizing inverter controls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Voltage positioning using co-optimization of controllable grid assets in radial networks

With increasing penetration of solar PV, some distribution feeders are experiencing highly variable net-load flows and even reverse flows. To optimize distribution systems under such conditions, the scheduling of mechanical devices, such as OLTCs and capacitor banks, needs to take into account forecasted solar PV and actual grid conditions. However, these legacy switching assets are operated on a daily or hourly timescale, due to the wear and tear associated with mechanical switching, which makes them unsuitable for real-time control. Therefore, there is a natural timescale- separation between these slower mechanical assets and the responsive nature of inverter-based resources. In this paper, we present a network admissible convex formulation for holistically scheduling controllable grid assets to position voltage optimally against solar PV. An optimal hourly schedule is presented that utilizes mechanical resources to position the predicted voltages close to nominal values, while minimizing the use of inverter-based resources (i.e., DERs), making them available for control at a faster time-scale (after the uncertainty reveals itself). A convex, inner approximation of the OPF problem is adapted to a mixed-integer linear program that minimizes voltage deviations from nominal (i.e., maximizes voltage margins). Here, the resulting OPF solution respects all the network constraints and is, hence, robust against modeling simplifications. Simulation based analysis on IEEE distribution feeders validates the approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Beyond triplet: Unconventional superconductivity in a spin-3/2 topological semimetal

In all known fermionic super fluids, Cooper pairs are composed of spin-1/2 quasi-particles that pair to form either spin-singlet or spin-triplet bound states. The "spin" of a Bloch electron, however, is xed by the symmetries of the crystal and the atomic orbitals from which it is derived, and in some cases can behave as if it were a spin-3/2 particle. The superconducting state of such a system allows pairing beyond spin-triplet, with higher spin quasi-particles combining to form quintet or even septet pairs. Here, we report evidence of unconventional superconductivity emerging from a spin-3/2 quasiparticle electronic structure in the half-Heusler semimetal YPtBi, a low-carrier density noncentrosymmetric cubic material with a high symmetry that preserves the p-like j = 3/2 manifold in the Bi-based Γ 8 band in the presence of strong spin-orbit coupling. With a striking linear temperature dependence of the London penetration depth, the existence of line nodes in the superconducting order parameter Δ is directly explained by a mixed-parity Cooper pairing model with high total angular momentum, consistent with a high-spin fermionic super fluid state. We propose a k ∙ p model of the j = 3/2 fermions to explain how a dominant J=3 septet pairing state is the simplest solution that naturally produces nodes in the mixed even-odd parity gap. Together with the underlying topologically non-trivial band structure, the unconventional pairing in this system represents a truly novel form of super fluidity that has strong potential for leading the development of a new generation of topological superconductors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Removing the Effects of Tropical Dynamics from North Pacific Climate Variability

Teleconnections from the Tropics energize variations of the North Pacific climate, but detailed diagnosis of this relationship has proven difficult. Simple univariate methods, such as regression on El Niño-Southern Oscillation (ENSO) indices, may be inadequate since the key dynamical processes involved -- including ENSO diversity in the Tropics, re-emergence of mixed layer thermal anomalies, and oceanic Rossby wave propagation in the North Pacific -- have a variety of overlapping spatial and temporal scales. Here we use a multivariate Linear Inverse Model to quantify tropical and extra-tropical multi-scale dynamical contributions to North Pacific variability, in both observations and CMIP6 models. In observations, we find that the Tropics are responsible for almost half of the seasonal variance, and almost three quarters of the decadal variance, along the North American coast and within the subtropical front region northwest of Hawaii. SST anomalies that are generated by local dynamics within the Northeast Pacific have much shorter time scales, consistent with transient weather forcing by Aleutian low anomalies. Variability within the Kuroshio-Oyashio Extension (KOE) region is considerably less impacted by the Tropics, on all time scales. Consequently, without tropical forcing the dominant pattern of North Pacific variability would be a KOE pattern, rather than the Pacific Decadal Oscillation (PDO). In contrast to observations, most CMIP6 historical simulations produce North Pacific variability that maximizes in the KOE region, with amplitude significantly higher than observed. Correspondingly, the simulated North Pacific in all CMIP6 models is shown to be relatively insensitive to the Tropics, with a dominant spatial pattern generally resembling the KOE pattern, not the PDO.

54 ENVIRONMENTAL SCIENCES↗

Efficient Computation Of Behavior Of Aircraft Tires

NASA technical paper discusses challenging application of computational structural mechanics to numerical simulation of responses of aircraft tires during taxing, takeoff, and landing. Presents details of three main elements of computational strategy: use of special three-field, mixed-finite-element models; use of operator splitting; and application of technique reducing substantially number of degrees of freedom. Proposed computational strategy applied to two quasi-symmetric problems: linear analysis of anisotropic tires through use of two-dimensional-shell finite elements and nonlinear analysis of orthotropic tires subjected to unsymmetric loading. Three basic types of symmetry and combinations exhibited by response of tire identified.

Tanner, John A.↗

Gender Differences in Baroreflex Sensitivity after Bed Rest

Two potential contributing factors to post-spaceflight orthostatic intolerance are decreases in baroreflex sensitivity (BRS) and sympathetic nervous system response. The purpose of this study was to examine the shape of the BRS curve and sympathetic response to a wide range of blood pressures (BP) before and during 6 head-down bed rest (BR). METHODS: Normal volunteers were tested one day before BR (20M, 1 0F) and near BR days 30 (20M, 10F), 60 (16M, 8F), and 90 (1 0M, 5F). BP was pharmacologically manipulated by 10-min infusions of phenylephrine (PE) and sodium nitroprusside (SNP) at 3 increasing concentrations with a 20-min rest between PE and SNP. Electrocardiogram and continuous finger blood pressure were recorded. A blood sample was drawn at the end of each infusion to measure plasma norepinephrine levels. The spontaneous baroreflex slope (SBS), a measure of BRS, was calculated as the slope of a sequence of 3 or more beats in which the systolic BP (SBP) and following R-R interval (RR) both increased or decreased. The data included saturated responses at the upper but not the lower end of the BP range. Mean response curves were constructed using second-order mixed model analysis. Results are based on term significance in the models. RESULTS RR: RR was lower during BR than pre BR (p<0.001). Pre BR males were modeled by a linear RR response to SBP (p=0.000) while females had a quadratic response which saturated at high SBP (p=0.019). By day 30, both genders were modeled by a linear response; compared to males, females had an attenuated (lower slope) RR response to changes in SBP (p=0.031). SBS: SBS vs SBP analysis showed a lower SBS during BR (p<0.001) when compared to pre BR. Females had a higher SBS than males pre BR (p=0.006). Females exhibited saturating SBS at higher SBP (p=0.016) on day 30, while males were modeled by a linear SBS response to SBP (p=0.035). NE: Females had different NE response to diastolic BP than males pre BR (p=0.035) and on day 30 (p=0.005). CONCLUSION: NE, RR and SBS responses to BP are affected by gender and BR. Not only do gender and BR baseline differences exist, but gender and BR also influence the slope and saturation of the BRS curves. Attenuated and saturating RR and SBS responses, as well as differences in baseline values, may contribute to the higher rates of orthostatic intolerance in women and after bed rest.

Arzeno, Natalia M.↗

Mixed convective/dynamic roll vortices and their effects on initial wind and temperature profiles

The onset and development of both dynamically and convectively forced boundary layer rolls are studied with linear and nonlinear analyses of a truncated spectral model of shallow Boussinesq flow. Emphasis is given here on the energetics of the dominant roll modes, on the magnitudes of the roll-induced modifications of the initial basic state wind and temperature profiles, and on the sensitivity of the linear stability results to the use of modified profiles as basic states. It is demonstrated that the roll circulations can produce substantial changes to the cross-roll component of the initial wind profile and that significant changes in orientation angle estimates can result from use of a roll-modified profile in the stability analysis. These results demonstrate that roll contributions must be removed from observed background wind profiles before using them to investigate the mechanisms underlying actual secondary flows in the boundary layer. The model is developed quite generally to accept arbitrary basic state wind profiles as dynamic forcing. An Ekman profile is chosen here merely to provide a means for easy comparison with other theoretical boundary layer studies; the ultimate application of the model is to study observed boundary layer profiles. Results of the analytic stability analysis are validated by comparing them with results from a larger linear model. For an appropriate Ekman depth, a complete set of transition curves is given in forcing parameter space for roll modes driven both thermally and dynamically. Preferred orientation angles, horizontal wavelengths and propagation frequencies, as well as energetics and wind profile modifications, are all shown to agree rather well with results from studies on Ekman layers as well as with studies on near-neutral and convective atmospheric boundary layers.

Haack, Tracy↗

Stochastic scheduling of generating units with weekly energy storage: A hybrid decomposition approach

We propose a solution method for the large-scale stochastic unit commitment (SUC) problem with weekly-dispatched energy storage and significant weather-dependent stochastic generating capacity. Weekly storage facilities that mostly charge during weekends and discharge during weekdays require a weekly scheduling of generating units, which result in a large-scale optimization problem. This SUC problem is formulated as a two-stage stochastic model and we use the conditional value-at-risk as a risk measure. Using a Benders framework, the proposed solution method decomposes the problem into a mixed-integer linear master problem and linear and continuous subproblems. The master problem corresponds to the first-stage decisions throughout the week and includes all the commitment (binary) variables and their corresponding constraints. The subproblems correspond to the actual dispatch of the generating units on a weekly basis. Based on the success of column-and-constraint generation algorithms to solve robust optimization problems, we improve the low communication between the master problem and the subproblems in the standard Benders decomposition by adding primal variables and constraints from the subproblems to the master problem, which provides a better approximation of the recourse function. Furthermore, our computational experiments demonstrate the effectiveness of the proposed decomposition method using an instance of the South Carolina synthetic system with 90 generating units under 40 scenarios.

25 ENERGY STORAGE↗