Search NASA⌕ Search

SEARCH · Search NASA

Results for “Liquid sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Direct observation of electric field-induced magnetism in a molecular magnet

Abstract We report the direct observation of an electrically-induced magnetic susceptibility in the molecular nano- magnet [Fe 3 O(O 2 CPh) 6 (py) 3 ]ClO 4 · py, an Fe 3 trimer. This magnetoelectric effect results from the breaking of spatial inversion symmetry due to the spin configurations of the antiferromagnetic trimer. Both static and very low frequency electric fields were used. Fractional changes of the magnetic susceptibility of 11 ppb $$\pm 2$$ ± 2 per kVm -1 for the temperature range 8 . 5 < T < 13 . 5 K were observed for applied electric fields up to 62 kV m − 1 . The changes in susceptibility were measured using a tunnel diode oscillator operating at liquid helium temperatures while the sample is held at a higher regulated temperature.

30 DIRECT ENERGY CONVERSION↗

Atmospheric-pressure ionization and fragmentation of peptides by solution-cathode glow discharge

Modern “-omics” (e.g., proteomics, glycomics, metabolomics, etc.) analyses rely heavily on electrospray ionization and tandem mass spectrometry to determine the structural identity of target species. Unfortunately, these methods are limited to specialized mass spectrometry instrumentation. Here in this paper, a novel approach is described that enables ionization and controlled, tunable fragmentation of peptides at atmospheric pressure. In the new source, a direct-current plasma is sustained between a tapered metal rod and a flowing sample-containing solution. As the liquid stream contacts the electrical discharge, peptides from the solution are volatilized, ionized, and fragmented. At high discharge currents (e.g., 70 mA), electrospray-like spectra are observed, dominated by singly and doubly protonated molecular ions. At lower currents (35 mA), many peptides exhibit extensive fragmentation, with a-, b-, c-, x-, and y-type ion series present as well as complex fragments, such as d-type ions, not previously observed with atmospheric-pressure dissociation. Though the mechanism of fragmentation is currently unclear, observations indicate it could result from the interaction of peptides with gas-phase radicals or ultraviolet radiation generated within the plasma.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a continuous synthesis process for carbamazepine using validated in-line Raman spectroscopy and kinetic modelling for disturbance simulation

Mitigation of failure modes in the continuous synthesis (CS) of a drug substance (DS) has the potential to widen the adoption of continuous manufacturing (CM) technologies by the pharmaceutical industry. Here, this work demonstrates the development of a robust continuous process for the synthesis of carbamazepine (CBZ), an essential medicine as per the World Health Organization (WHO), facilitated by kinetic modelling and monitored by in-line Raman spectroscopy. Accurate kinetic modelling and the use of validated process analytical technology (PAT) models for quantitative measurement were found to play an important role in developing CS of drug substances. Kinetic data for the formation of CBZ from iminostilbene (ISB) were collected by batch reaction sampling and high-performance liquid chromatography (HPLC) analysis. A non-linear solver and iterative method was applied to determine two sets of Arrhenius parameters simultaneously for the reaction system by minimizing the standard error of the model fit. The start-up and dynamic equilibrium stages for the CS of CBZ using a continuous stirred tank reactor (CSTR) were modelled based on the batch kinetic data and employed to optimize conversion and simulate process disturbances. An in-line Raman spectroscopy method was successfully developed, validated, and integrated to determine the concentrations of CBZ and ISB within the operating range for the CS. The CS kinetic model was evaluated experimentally from startup to dynamic equilibrium over 10 residence times with monitoring by HPLC and in-line Raman spectroscopy. The developed kinetic model in tandem with in-line Raman spectroscopy successfully predicted disturbances due to changes in process variables and can serve as a useful tool in the future design of advanced process control strategies for the continuous synthesis of CBZ.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Concentration Of Tritium In Urine And Internal Radiation Dose Estimation Of PTNBR Radiation Workers

The operation of Triga 2000 reactor in Nuclear Technology Center for Materials and Radiometry (PTNBR BATAN) normally produce tritium radionuclide which is the activation product of deuterium atom in reactor primary cooling water. According to previous monitoring, tritium was detected with the concentration of 8.236{+-}0.677 kBq/L and 1.704{+-}0.046 Bq/L in the primary cooling water and in reactor hall air, respectively. The tritium in reactor hall air chronically can be inhaled by the workers. In this research, tritium content in radiation workers' urine was determined to estimate the internal radiation doses received by the workers. About 50-100 mL of urine samples were collected from 48 PTNBR workers that is classified as 24 radiation workers and 24 administration staffs as a control. Urine samples of 25 mL were then prepared by active charcoal and KMnO{sub 4} addition and followed with complete distillation. The 2 mL of distillate was added with 13 mL scintillator, shaked vigorously and remained in cool and dark condition for about 24 hours. The tritium in the samples was then measured using liquid scintillation counter (LSC) for 1 hour. From the measurement results it was obtained that the tritium concentration in the urine of radiation workers were in the range of not detected and 5.191 Bq/mL, whereas in the administration staffs the concentration were between not detected and 4.607 Bq/mL. Internally radiation doses were calculated using the tritium concentration data, and it was found the averages about 0.602 {mu}Sv/year and 0.532 {mu}Sv/year for radiation workers and administration staffs, respectively. The doses received by the workers were lower than that of the permissible doses from tritium, i.e. 40 {mu}Sv/year.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A design of resonant inelastic X-ray scattering (RIXS) spectrometer for spatial- and time-resolved spectroscopy

The optical design of a Hettrick–Underwood-style soft X-ray spectrometer with Wolter type 1 mirrors is presented. The spectrometer with a nominal length of 3.1 m can achieve a high resolving power (resolving power higher than 10000) in the soft X-ray regime when a small source beam (<3 µm in the grating dispersion direction) and small pixel detector (5 µm effective pixel size) are used. Adding Wolter mirrors to the spectrometer before its dispersive elements can realize the spatial imaging capability, which finds applications in the spectroscopic studies of spatially dependent electronic structures in tandem catalysts, heterostructures, etc . In the pump–probe experiments where the pump beam perturbs the materials followed by the time-delayed probe beam to reveal the transient evolution of electronic structures, the imaging capability of the Wolter mirrors can offer the pixel-equivalent femtosecond time delay between the pump and probe beams when their wavefronts are not collinear. In combination with some special sample handing systems, such as liquid jets and droplets, the imaging capability can also be used to study the time-dependent electronic structure of chemical transformation spanning multiple time domains from microseconds to nanoseconds. The proposed Wolter mirrors can also be adopted to the existing soft X-ray spectrometers that use the Hettrick–Underwood optical scheme, expanding their capabilities in materials research.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Determination of cis,cis- and cis,trans- Muconic Acid from Biological Conversion: Laboratory Analytical Procedure (LAP)

Muconic acid is an important platform molecule for production of bio-based polymers. To date, cis,cis-muconic acid (ccMA) has been produced from multiple types of carbon sources including carbohydrates and aromatic compounds via cultivation with genetically engineered microbes. Accurate analysis of muconic acid has previously been a challenge due to ccMA isomerization into cis,trans-muconic acid (ctMA). This Laboratory Analytical Procedure (LAP) is used to separately quantify ccMA and ctMA as the total sum of muconic acid present in the liquid fraction of pretreated biological samples.

09 BIOMASS FUELS↗

Simulant Development of Potential 200 West Area Waste Feeds

Preliminary planning for retrieval, qualification, and pretreatment of waste in Hanford’s 200 West Area (200W) has begun as part of the West Area Risk Management project. Experimental studies to technically mature pretreatment process operations will likely be needed because of the uniqueness of 200W waste. Pacific Northwest National Laboratory formulated five simulants to represent 200W-qualified feed based on the preliminary flowsheet provided by Washington River Protection Solutions, LLC. The simulant recipes were devised using applicable historical information as a reference point to support the use of the flowsheet waste vectors, which were combined into five distinct groups. These five groups formed the basis for the liquid composition targets that were adapted into recipes using charged-balanced salt species. The liquid phase recipes were batched in 1-L quantities and analyzed at Pacific Northwest National Laboratory. Once confirmed to be stable, the liquid solutions were tested for compatibility with candidate solid components. Specific solid components were recommended based on cross-examining the proposed solid phases in the flowsheet with relevant data from the literature. Mixtures of solid components were added to aliquots of the liquid batches and sub-sampled to measure particle size distribution. The measured distribution was compared to independently created benchmark distributions appropriate for each simulant. This process was iterated until a solid phase composition that resulted in a representative particle size distribution was found. After the final compositions were confirmed, a suite of chemical and physical characterization data was collected. This report describes the simulant basis, formulation methodology, laboratory measurements, and data collected for the recipes recommended to represent 200W waste feeds.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigation of Lubricant Additive Interactions on Gasoline Particulate Filters

To understand how the composition of novel lubricant additives and their ash interact with gasoline particulate filters (GPFs), an accelerated aging protocol was conducted using three lubricant additive formulations and two GPF types. The additive packages (adpaks) consisted of Ca+Mg detergent in a 3:1 or 0:1 ratio and an anti-wear component—either zinc dialkyl dithiophosphate (ZDDP) or a novel phosphonium-phosphinate ionic liquid (IL) substitute. The particulate sampling captured amount/compositions of particulate matter (PM) generated, total particulate number, and size distribution. Five ash loadings were completed. GPF position and adpak composition affected the backpressure, ash composition, ash morphology, and captured mass. The particulate sampling indicated that the ash component consisted primarily of particles less than 50 nm in size and that the Mg-only adpak resulted in more particulate of 50–400 nm in size. Postmortem materials characterization indicated GPFs in the underfloor position had deeper penetration of ash into the walls compared to the close-coupled position. Additionally, the Mg-only adpak had a higher filter collection efficiency (>90%) and the ash particles consisted of a higher concentration of dense ash material. In contrast, four of the 3:1 Ca:Mg lubricant adpaks resulted in a collection efficiency of only 40–50%. Although the collection efficiency was higher with the Mg-only adpak, the ash layer in the GPF was not thicker, nor was the penetration into the wall more significant, and surprisingly the full useful life (FUL) backpressure was lower than with Ca:Mg adpaks. The higher density of the Mg-derived ash was the only detectable difference. A possible explanation of this observation is that Mg ash has a lower melting point and is more susceptible to densification during combustion or GPF regeneration. The substitution of IL in place of the ZDDP did not lead to any notable changes in collection efficiency or location of the ash.

42 ENGINEERING↗

Standard Flow Liquid Chromatography for Shotgun Proteomics in Bioenergy Research

Over the past 10 years, the bioenergy field has realized significant achievements that have encouraged many follow on efforts centered on biosynthetic production of fuel-like compounds. Key to the success of these efforts has been transformational developments in feedstock characterization and metabolic engineering of biofuel-producing microbes. Lagging far behind these advancements are analytical methods to characterize and quantify systems of interest to the bioenergy field. In particular, the utilization of proteomics, while valuable for identifying novel enzymes and diagnosing problems associated with biofuelproducing microbes, is limited by a lack of robustness and limited throughput. Nano-flow liquid chromatography coupled to high-mass accuracy, high-resolution mass spectrometers has become the dominant approach for the analysis of complex proteomic samples, yet such assays still require dedicated experts for data acquisition, analysis, and instrument upkeep. The recent adoption of standard flow chromatography (ca. 0.5 mL/min) for targeted proteomics has highlighted the robust nature and increased throughput of this approach for sample analysis. Consequently, we assessed the applicability of standard flow liquid chromatography for shotgun proteomics using samples from Escherichia coli and Arabidopsis thaliana, organisms commonly used as model systems for lignocellulosic biofuels research. Employing 120 min gradients with standard flow chromatography, we were able to routinely identify nearly 800 proteins from E. coli samples; while for samples from Arabidopsis, over 1,000 proteins could be reliably identified. An examination of identified peptides indicated that the method was suitable for reproducible applications in shotgun proteomics. Standard flow liquid chromatography for shotgun proteomics provides a robust approach for the analysis of complex samples. To the best of our knowledge, this study represents the first attempt to validate the standard flow approach for shotgun proteomics.

09 BIOMASS FUELS↗

Simplified Method for the In Situ Collection and Laboratory Analysis of Cosmogenic Tracers (Sulfur-35 and Sodium-22) to Determine Residence Time Distributions and Water Ages

The use of cosmogenically produced sulfur-35 (T 1/2 = 87 days) and sodium-22 (T 1/2 = 2.6 years) as intrinsic tracers can provide valuable information on catchment hydrology, flow paths, and subsurface storage. A new and straightforward method was created to determine the activities of both 35 S and 22 Na in various water sources by pumping large volumes (up to 1000 L) of water through cation- and anion-exchange resin columns in the field to collect sodium and sulfate ions and simple chemistry in the lab. Samples are counted for 35 S using liquid scintillation counting (LSC) and for 22 Na via γ spectroscopy. Our novel in situ method provides faster sample throughput as well as better counting statistics and lower detection limits. Both methods were successfully applied at the Southern Sierra Critical Zone Observatory.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved Single-Cell Proteome Coverage Using Narrow-Bore Packed NanoLC Columns and Ultrasensitive Mass Spectrometry

Single-cell proteomics can provide unique insights into biological processes by resolving heterogeneity that is obscured by bulk measurements. Gains in the overall sensitivity and proteome coverage through improvements in sample processing and analysis increase the information content obtained from each cell, particularly for less abundant proteins. Here we report on improved single-cell proteome coverage through the combination of the previously developed Nanodroplet Processing in One Pot for Trace Samples (nanoPOTS) platform with further miniaturization of liquid chromatography (LC) separations and implementation of an ultrasensitive latest-generation mass spectrometry (MS) instrument. Following nanoPOTS sample preparation, protein digest from single cells were separated using a 20-µm-i.d. in-house-packed nanoLC column. Separated peptides were ionized using an etched fused silica emitter capable of stable ionization at the ~20 nL/min flow rate provided by the LC separation. Ultrasensitive LC-MS analysis was achieved using the Orbitrap Eclipse Tribrid mass spectrometer. An average of 362 protein groups were identified by MS/MS from single HeLa cells, and 874 protein groups were identified using the Match Between Runs (MBR) feature of MaxQuant. This represents a >70% increase in label-free proteome coverage for single cells relative to previous efforts using larger-bore (30-µm-i.d.) LC columns coupled to a previous-generation MS (Orbitrap Fusion Lumos).

Cong, Yongzheng↗

Capture probe

A system and method for sampling a sample material includes a device for directing sample into a capture probe. The device for supplying sample material to the probe can be a device for radiating energy to the surface to eject sample from the sample material. A probe includes an outer probe housing having an open end. A liquid supply conduit has an outlet positioned to deliver liquid to the open end. An exhaust conduit removes liquid from the open end of the housing. The liquid supply conduit can be connectable to a liquid supply for delivering liquid at a first volumetric flow rate to the open end of the housing. A liquid exhaust system can be in fluid connection with the liquid exhaust conduit for removing liquid from the liquid exhaust conduit at a second volumetric flow rate such that gas with sample is withdrawn with the liquid.

Kertesz, Vilmos↗

Capture probe

A system and method for sampling a sample material includes a device for directing sample into a capture probe. The device for supplying sample material to the probe can be a device for radiating energy to the sample material to eject sample from the sample material. A probe includes an outer probe housing having an open end. A liquid supply conduit has an outlet positioned to deliver liquid to the open end. An exhaust conduit removes liquid from the open end of the housing. The liquid supply conduit can be connectable to a liquid supply for delivering liquid at a first volumetric flow rate to the open end of the housing. A liquid exhaust system can be in fluid connection with the liquid exhaust conduit for removing liquid from the liquid exhaust conduit at a second volumetric flow rate such that gas with sample is withdrawn with the liquid.

Kertesz, Vilmos↗

macroMS: Image-Guided Analysis of Random Objects by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry

Mass spectrometry imaging is well-suited to characterizing sample surfaces for their chemical content in a spatially resolved manner. However, when the surface contains small objects with significant empty spaces between them, more efficient approaches to sample acquisition are possible. Image-guided mass spectrometry (MS) enables high-throughput analysis of a diverse range of sample types, such as microbial colonies, liquid microdroplets, and others, by recognizing and analyzing selected location targets in an image. Here, we describe an imaging protocol and macroMS, an online software suite that can be used to enhance MS measurements of macroscopic samples that are imaged by a camera or a flatbed scanner. Furthermore, the web-based tool enables users to find and filter targets from the optical images, correct optical distortion issues for improved spatial location of selected targets, input the custom geometry files into an MS device to acquire spectra at the selected locations, and finally, perform limited data analysis and use visualization tools to aid locating samples containing compounds of interest. Using the macroMS suite, an enzyme mutant library of Saccharomyces cerevisiae and nL droplet arrays of Escherichia coli and Pseudomonas fluorescens have been assayed at a rate of ~2 s/sample.

47 OTHER INSTRUMENTATION↗

Reconstructed Fermi Surface of Underdoped Bi2Sr2CaCu2O8 Cuprate Superconductors

The Fermi surface topologies of underdoped samples of the high-T{sub c} superconductor Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8+{delta}} have been measured with angle resolved photoemission. By examining thermally excited states above the Fermi level, we show that the observed Fermi surfaces in the pseudogap phase are actually components of fully enclosed hole pockets. The spectral weight of these pockets is vanishingly small at the magnetic zone boundary, creating the illusion of Fermi 'arcs.' The area of the pockets as measured in this study is consistent with the doping level, and hence carrier density, of the samples measured. Furthermore, the shape and area of the pockets is well reproduced by phenomenological models of the pseudogap phase as a spin liquid.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pyrolysis of municipal plastic wastes II: Influence of raw material composition under catalytic conditions

Highlights: > ZSM-5 zeolite catalytic pyrolysis transforms municipal plastic waste into liquids and gases useful as fuels or source of chemicals. > The composition of the waste sample plays an important role on the catalyst activity and the products obtained. > ZSM-5 zeolite is somehow deactivated when high proportions of fine inorganic materials are present in the sample. > When the sample contains cellulose-based materials, the formation of a two-phase liquid fraction can be avoided by a low temperature step. - Abstract: In this work, the results obtained in catalytic pyrolysis of three plastic waste streams which are the rejects of an industrial packing wastes sorting plant are presented. The samples have been pyrolysed in a 3.5 dm{sup 3} reactor under semi-batch conditions at 440 {sup o}C for 30 min in nitrogen atmosphere. Commercial ZSM-5 zeolite has been used as catalyst in liquid phase contact. In every case, high HHV gases and liquids which can be useful as fuels or source of chemicals are obtained. A solid fraction composed of the inorganic material contained in the raw materials and some char formed in the pyrolysis process is also obtained. The zeolite has shown to be very effective to produce liquids with great aromatics content and C3-C4 fraction rich gases, even though the raw material was mainly composed of polyolefins. The characteristics of the pyrolysis products as well as the effect of the catalyst vary depending on the composition of the raw material. When paper rich samples are pyrolysed, ZSM-5 zeolite increases water production and reduces CO and CO{sub 2} generation. If stepwise pyrolysis is applied to such sample, the aqueous liquid phase can be separated from the organic liquid fraction in a first low temperature step.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Subnanogram proteomics: Impact of LC column selection, MS instrumentation and data analysis strategy on proteome coverage for trace samples

One of the greatest challenges for mass spectrometry (MS)-based proteomics is the limited ability to analyze small samples. Here we investigate the relative contributions of liquid chromatography (LC), MS instrumentation and data analysis methods with the aim of improving proteome coverage for sample sizes ranging from 0.5 ng to 50 ng. We show that the LC separations utilizing 30-µm-i.d. columns increase signal intensity by >3-fold relative to those using 75-µm-i.d. columns, leading to 32% increase in peptide identifications. The Orbitrap Fusion Lumos mass spectrometer significantly boosted both sensitivity and sequencing speed relative to earlier generation Orbitraps (e.g., LTQ-Orbitrap), leading to a ~3× increase in peptide identifications and 1.7× increase in identified protein groups for 2 ng tryptic digests of bacterial lysate. The Match Between Runs algorithm of open-source MaxQuant software further increased proteome coverage by ~ 95% for 0.5 ng samples and by ~42% for 2 ng samples. The present platform is capable of identifying >3000 protein groups from tryptic digestion of cell lysates equivalent to 50 HeLa cells and 100 THP-1 cells (~10 ng total proteins), respectively, and >950 proteins from subnanogram bacterial and archaeal cell lysates. The present ultrasensitive LC-MS platform is expected to enable deep proteome coverage for subnanogram samples, including single mammalian cells.

Environmental Molecular Sciences Laboratory↗