Search NASA⌕ Search

SEARCH · Search NASA

Results for “MACROMOLECULE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Improvement of the quality of lumazine synthase crystals by protein engineering

Site-directed mutagenesis has been applied to improve the overexpression and purification of the icosahedral enzyme lumazine synthase from B. subtilis as well as to produce a new crystal form. The mutant protein crystallizes in space group R3 and diffracts X-rays to 1.6 Å resolution. Icosahedral macromolecules have a wide spectrum of potential nanotechnological applications, the success of which relies on the level of accuracy at which the molecular structure is known. Lumazine synthase from Bacillus subtilis forms a 150 Å icosahedral capsid consisting of 60 subunits and crystallizes in space group P6{sub 3}22 or C2. However, the quality of these crystals is poor and structural information is only available at 2.4 Å resolution. As classical strategies for growing better diffracting crystals have so far failed, protein engineering has been employed in order to improve the overexpression and purification of the molecule as well as to obtain new crystal forms. Two cysteines were replaced to bypass misfolding problems and a charged surface residue was replaced to force different molecular packings. The mutant protein crystallizes in space group R3, with unit-cell parameters a = b = 313.02, c = 365.77 Å, α = β = 90.0, γ = 120°, and diffracts to 1.6 Å resolution.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Avoidable errors in deposited macromolecular structures: an impediment to efficient data mining

Whereas the vast majority of the more than 85 000 crystal structures of macromolecules currently deposited in the Protein Data Bank are of high quality, some suffer from a variety of imperfections. Although this fact has been pointed out in the past, it is still worth periodic updates so that the metadata obtained by global analysis of the available crystal structures, as well as the utilization of the individual structures for tasks such as drug design, should be based on only the most reliable data. Here, selected abnormal deposited structures have been analysed based on the Bayesian reasoning that the correctness of a model must be judged against both the primary evidence as well as prior knowledge. These structures, as well as information gained from the corresponding publications (if available), have emphasized some of the most prevalent types of common problems. The errors are often perfect illustrations of the nature of human cognition, which is frequently influenced by preconceptions that may lead to fanciful results in the absence of proper validation. Common errors can be traced to negligence and a lack of rigorous verification of the models against electron density, creation of non-parsimonious models, generation of improbable numbers, application of incorrect symmetry, illogical presentation of the results, or violation of the rules of chemistry and physics. Paying more attention to such problems, not only in the final validation stages but during the structure-determination process as well, is necessary not only in order to maintain the highest possible quality of the structural repositories and databases but most of all to provide a solid basis for subsequent studies, including large-scale data-mining projects. For many scientists PDB deposition is a rather infrequent event, so the need for proper training and supervision is emphasized, as well as the need for constant alertness of reason and critical judgment as absolutely necessary safeguarding measures against such problems. Ways of identifying more problematic structures are suggested so that their users may be properly alerted to their possible shortcomings.

model validation↗

Solving coiled-coil protein structures

With the availability of more than 100,000 entries stored in the Protein Data Bank (PDB) that can be used as search models, molecular replacement (MR) is currently the most popular method of solving crystal structures of macromolecules. Significant methodological efforts have been directed in recent years towards making this approach more powerful and practical. This resulted in the creation of several computer programs, highly automated and user friendly, that are able to successfully solve many structures even by researchers who, although interested in structures of biomolecules, are not very experienced in crystallography.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Serial millisecond crystallography of membrane and soluble protein microcrystals using synchrotron radiation

Crystal structure determination of biological macromolecules using the novel technique of serial femtosecond crystallography (SFX) is severely limited by the scarcity of X-ray free-electron laser (XFEL) sources. However, recent and future upgrades render microfocus beamlines at synchrotron-radiation sources suitable for room-temperature serial crystallography data collection also. Owing to the longer exposure times that are needed at synchrotrons, serial data collection is termed serial millisecond crystallography (SMX). As a result, the number of SMX experiments is growing rapidly, with a dozen experiments reported so far. Here, the first high-viscosity injector-based SMX experiments carried out at a US synchrotron source, the Advanced Photon Source (APS), are reported. Microcrystals (5–20 µm) of a wide variety of proteins, including lysozyme, thaumatin, phycocyanin, the human A 2A adenosine receptor (A 2A AR), the soluble fragment of the membrane lipoprotein Flpp3 and proteinase K, were screened. Crystals suspended in lipidic cubic phase (LCP) or a high-molecular-weight poly(ethylene oxide) (PEO; molecular weight 8 000 000) were delivered to the beam using a high-viscosity injector. In-house data-reduction (hit-finding) software developed at APS as well as the SFX data-reduction and analysis software suites Cheetah and CrystFEL enabled efficient on-site SMX data monitoring, reduction and processing. Complete data sets were collected for A 2A AR, phycocyanin, Flpp3, proteinase K and lysozyme, and the structures of A 2A AR, phycocyanin, proteinase K and lysozyme were determined at 3.2, 3.1, 2.65 and 2.05 Å resolution, respectively. The data demonstrate the feasibility of serial millisecond crystallography from 5–20 µm crystals using a high-viscosity injector at APS. The resolution of the crystal structures obtained in this study was dictated by the current flux density and crystal size, but upcoming developments in beamline optics and the planned APS-U upgrade will increase the intensity by two orders of magnitude. Furthermore, these developments will enable structure determination from smaller and/or weakly diffracting microcrystals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mix-and-diffuse serial synchrotron crystallography

Unravelling the interaction of biological macromolecules with ligands and substrates at high spatial and temporal resolution remains a major challenge in structural biology. The development of serial crystallography methods at X-ray free-electron lasers and subsequently at synchrotron light sources allows new approaches to tackle this challenge. Here, a new polyimide tape drive designed for mix-and-diffuse serial crystallography experiments is reported. The structure of lysozyme bound by the competitive inhibitor chitotriose was determined using this device in combination with microfluidic mixers. The electron densities obtained from mixing times of 2 and 50 s show clear binding of chitotriose to the enzyme at a high level of detail. Here, the success of this approach shows the potential for high-throughput drug screening and even structural enzymology on short timescales at bright synchrotron light sources.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A new MR-SAD algorithm for the automatic building of protein models from low-resolution X-ray data and a poor starting model

Determining macromolecular structures from X-ray data with resolution worse than 3Å remains a challenge. Even if a related starting model is available, its incompleteness or its bias together with a low observation-to-parameter ratio can render the process unsuccessful or very time-consuming. Yet, many biologically important macromolecules, especially large macromolecular assemblies, membrane proteins and receptors, tend to provide crystals that diffract to low resolution. A new algorithm to tackle this problem is presented that uses a multivariate function to simultaneously exploit information from both an initial partial model and low-resolution single-wavelength anomalous diffraction data. The new approach has been used for six challenging structure determinations, including the crystal structures of membrane proteins and macromolecular complexes that have evaded experts using other methods, and large structures from a 3.0 Å resolution F1-ATPase data set an a 4.5Å resolution SecYEG–SecA complex data set. All of the models were automatically built by the method to Rfree values of between 28.9 and 39.9% and were free from the initial model bias.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparing serial X-ray crystallography and microcrystal electron diffraction (MicroED) as methods for routine structure determination from small macromolecular crystals

Innovative new crystallographic methods are facilitating structural studies from ever smaller crystals of biological macromolecules. In particular, serial X-ray crystallography and microcrystal electron diffraction (MicroED) have emerged as useful methods for obtaining structural information from crystals on the nanometre to micrometre scale. Despite the utility of these methods, their implementation can often be difficult, as they present many challenges that are not encountered in traditional macromolecular crystallography experiments. Here, XFEL serial crystallography experiments and MicroED experiments using batch-grown microcrystals of the enzyme cyclophilin A are described. The results provide a roadmap for researchers hoping to design macromolecular microcrystallography experiments, and they highlight the strengths and weaknesses of the two methods. Specifically, we focus on how the different physical conditions imposed by the sample-preparation and delivery methods required for each type of experiment affect the crystal structure of the enzyme.

36 MATERIALS SCIENCE↗

Rapid and efficient room-temperature serial synchrotron crystallography using the CFEL TapeDrive

Serial crystallography at conventional synchrotron light sources (SSX) offers the possibility to routinely collect data at room temperature using micrometre-sized crystals of biological macromolecules. However, SSX data collection is not yet as routine and currently takes significantly longer than the standard rotation series cryo-crystallography. Thus, its use for high-throughput approaches, such as fragment-based drug screening, where the possibility to measure at physiological temperatures would be a great benefit, is impaired. On the way to highthroughput SSX using a conveyor belt based sample delivery system – the CFEL TapeDrive – with three different proteins of biological relevance (Klebsiella pneumoniae CTX-M-14 β-lactamase, Nectria haematococca xylanase GH11 and Aspergillus flavus urate oxidase), it is shown here that complete datasets can be collected in less than a minute and only minimal amounts of sample are required.

36 MATERIALS SCIENCE↗

Toward a quantitative description of solvation structure: a framework for differential solution scattering measurements

Appreciating that the role of the solute–solvent and other outer-sphere interactions is essential for understanding chemistry and chemical dynamics in solution, experimental approaches are needed to address the structural consequences of these interactions, complementing condensed-matter simulations and coarse-grained theories. High-energy X-ray scattering (HEXS) combined with pair distribution function analysis presents the opportunity to probe these structures directly and to develop quantitative, atomistic models of molecular systems in situ in the solution phase. However, at concentrations relevant to solution-phase chemistry, the total scattering signal is dominated by the bulk solvent, prompting researchers to adopt a differential approach to eliminate this unwanted background. Though similar approaches are well established in quantitative structural studies of macromolecules in solution by small- and wide-angle X-ray scattering (SAXS/WAXS), analogous studies in the HEXS regime—where sub-ångström spatial resolution is achieved—remain underdeveloped, in part due to the lack of a rigorous theoretical description of the experiment. To address this, herein we develop a framework for differential solution scattering experiments conducted at high energies, which includes concepts of the solvent-excluded volume introduced to describe SAXS/WAXS data, as well as concepts from the time-resolved X-ray scattering community. Our theory is supported by numerical simulations and experiment and paves the way for establishing quantitative methods to determine the atomic structures of small molecules in solution with resolution approaching that of crystallography.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Towards time-resolved MicroED grid preparation using mix-and-inject gas dynamic virtual nozzles

Recent progress in gas dynamic virtual nozzle (GDVN) technologies in combination with high-brilliance synchrotron and X-ray free-electron lasers (XFELs) has allowed the visualization of protein dynamics in crystallo by mixing macromolecular protein crystals with a substrate using tunable mixing times on the order of milliseconds to seconds prior to serial X-ray diffraction data collection. This has become the method of choice for high-resolution structure determination of intermediate states. However, such experiments require large counts of crystals of proper sizes for high-resolution data collection, and premium beam times for screening efforts. Cryogenic microcrystal electron diffraction (MicroED) represents a complementary technique that may be a more accessible avenue for time-resolved nanocrystallography compared with serial X-ray diffraction experiments. MicroED can produce full diffraction datasets from just a few submicrometre-thick crystals, and the approach is more readily accessible, requiring standard cryogenic transmission electron microscopy (TEM) equipment available at many universities and institutes. Cryogenic MicroED, like other forms of cryo-EM, begins with rapidly freezing biological material on electron microscopy grids. In the case of MicroED, micro- to nano-crystals (<500 nm thick) are deposited onto electron microscopy grids and plunge-frozen for subsequent electron diffraction data collection. Here, we have incorporated GDVN technology developed originally for XFEL experiments into the freezing process as a first step towards time-resolved studies. We describe the limited deposition efficiency of the model MicroED protein proteinase K on TEM grids using GDVNs, preceding sample vitrification and successful MicroED data collection. We discuss both the initial results from such experiments and the methodological challenges in developing this approach into a reliable workflow for millisecond-to-second time-resolved structural studies of macromolecules. Our results promise a strategy to deposit crystals on grids using GDVNs and determine high-resolution structures by MicroED, constituting a first step towards development of time-resolved MicroED experiments.

MicroED↗

Latest methods of fluorescence-based protein crystal identification

Fluorescence, whether intrinsic or by using trace fluorescent labeling, can be a powerful aid in macromolecule crystallization. Its use in screening for crystals is discussed here. Successful protein crystallization screening experiments are dependent upon the experimenter being able to identify positive outcomes. The introduction of fluorescence techniques has brought a powerful and versatile tool to the aid of the crystal grower. Trace fluorescent labeling, in which a fluorescent probe is covalently bound to a subpopulation (<0.5%) of the protein, enables the use of visible fluorescence. Alternatively, one can avoid covalent modification and use UV fluorescence, exploiting the intrinsic fluorescent amino acids present in most proteins. By the use of these techniques, crystals that had previously been obscured in the crystallization drop can readily be identified and distinguished from amorphous precipitate or salt crystals. Additionally, lead conditions that may not have been obvious as such under white-light illumination can be identified. In all cases review of the screening plate is considerably accelerated, as the eye can quickly note objects of increased intensity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Large-volume protein crystal growth for neutron macromolecular crystallography

Neutron macromolecular crystallography (NMC) is the prevailing method for the accurate determination of the positions of H atoms in macromolecules. As neutron sources are becoming more available to general users, finding means to optimize the growth of protein crystals to sizes suitable for NMC is extremely important. Historically, much has been learned about growing crystals for X-ray diffraction. However, owing to new-generation synchrotron X-ray facilities and sensitive detectors, protein crystal sizes as small as in the nano-range have become adequate for structure determination, lessening the necessity to grow large crystals. Here, some of the approaches, techniques and considerations for the growth of crystals to significant dimensions that are now relevant to NMC are revisited. We report that these include experimental strategies utilizing solubility diagrams, ripening effects, classical crystallization techniques, microgravity and theoretical considerations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Trace fluorescent labeling for protein crystallization

The presence of a covalently bound fluorescent probe at a concentration of <0.5% does not affect the outcome of macromolecule crystallization screening experiments. Additionally, the fluorescence can be used to determine new, not immediately apparent, lead crystallization conditions. Fluorescence can be a powerful tool to aid in the crystallization of proteins. In the trace-labeling approach, the protein is covalently derivatized with a high-quantum-yield visible-wavelength fluorescent probe. The final probe concentration typically labels ≤0.20% of the protein molecules, which has been shown to not affect the crystal nucleation or diffraction quality. The labeled protein is then used in a plate-screening experiment in the usual manner. As the most densely packed state of the protein is the crystalline form, then crystals show as the brightest objects in the well under fluorescent illumination. A study has been carried out on the effects of trace fluorescent labeling on the screening results obtained compared with nonlabeled protein, and it was found that considering the stochastic nature of the crystal nucleation process the presence of the probe did not affect the outcomes obtained. Other effects are realised when using fluorescence. Crystals are clearly seen even when buried in precipitate. This approach also finds ‘hidden’ leads, in the form of bright spots, with ∼30% of the leads found being optimized to crystals in a single-pass optimization trial. The use of visible fluorescence also enables the selection of colors that bypass interfering substances, and the screening materials do not have to be UV-transparent.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nanocrystalline protein domains via salting-out

Protein salting-out is a well established phenomenon that in many cases leads to amorphous structures and protein gels, which are usually not considered to be useful for protein structure determination. Here, microstructural measurements of several different salted-out protein dense phases are reported, including of lysozyme, ribonuclease A and an IgG1, showing that salted-out protein gels unexpectedly contain highly ordered protein nanostructures that assemble hierarchically to create the gel. The nanocrystalline domains are approximately 10–100 nm in size, are shown to have structures commensurate with those of bulk crystals and grow on time scales in the order of an hour to a day. Beyond revealing the rich, hierarchical nanoscale to mesoscale structure of protein gels, the nanocrystals that these phases contain are candidates for structural biology on next-generation X-ray free-electron lasers, which may enable the study of biological macromolecules that are difficult or impossible to crystallize in bulk.

Biochemistry & Molecular Biology↗

Efficient structure-factor modeling for crystals with multiple components

Diffraction intensities from a crystallographic experiment include contributions from the entire unit cell of the crystal: the macromolecule, the solvent around it and eventually other compounds. These contributions cannot typically be well described by an atomic model alone, i.e . using point scatterers. Indeed, entities such as disordered (bulk) solvent, semi-ordered solvent ( e.g. lipid belts in membrane proteins, ligands, ion channels) and disordered polymer loops require other types of modeling than a collection of individual atoms. This results in the model structure factors containing multiple contributions. Most macromolecular applications assume two-component structure factors: one component arising from the atomic model and the second one describing the bulk solvent. A more accurate and detailed modeling of the disordered regions of the crystal will naturally require more than two components in the structure factors, which presents algorithmic and computational challenges. Here an efficient solution of this problem is proposed. All algorithms described in this work have been implemented in the computational crystallography toolbox ( CCTBX ) and are also available within Phenix software. These algorithms are rather general and do not use any assumptions about molecule type or size nor about those of its components.

59 BASIC BIOLOGICAL SCIENCES↗

Transmission electron microscopy for the evaluation and optimization of crystal growth

The crystallization of protein samples remains the most significant challenge in structure determination by X-ray crystallography. Here, the effectiveness of transmission electron microscopy (TEM) analysis to aid in the crystallization of biological macromolecules is demonstrated. It was found that the presence of well ordered lattices with higher order Bragg spots, revealed by Fourier analysis of TEM images, is a good predictor of diffraction-quality crystals. Moreover, the use of TEM allowed (i) comparison of lattice quality among crystals from different conditions in crystallization screens; (ii) the detection of crystal pathologies that could contribute to poor X-ray diffraction, including crystal lattice defects, anisotropic diffraction and crystal contamination by heavy protein aggregates and nanocrystal nuclei; (iii) the qualitative estimation of crystal solvent content to explore the effect of lattice dehydration on diffraction and (iv) the selection of high-quality crystal fragments for microseeding experiments to generate reproducibly larger sized crystals. Applications to X-ray free-electron laser (XFEL) and micro-electron diffraction (microED) experiments are also discussed.

Stevenson, Hilary P.↗

Microfocus diffraction from different regions of a protein crystal: structural variations and unit-cell polymorphism

Real macromolecular crystals can be non-ideal in a myriad of ways. This often creates challenges for structure determination, while also offering opportunities for greater insight into the crystalline state and the dynamic behavior of macromolecules. To evaluate whether different parts of a single crystal of a dynamic protein, EutL, might be informative about crystal and protein polymorphism, a microfocus X-ray synchrotron beam was used to collect a series of 18 separate data sets from non-overlapping regions of the same crystal specimen. A principal component analysis (PCA) approach was employed to compare the structure factors and unit cells across the data sets, and it was found that the 18 data sets separated into two distinct groups, with large R values (in the 40% range) and significant unit-cell variations between the members of the two groups. This categorization mapped the different data-set types to distinct regions of the crystal specimen. Atomic models of EutL were then refined against two different data sets obtained by separately merging data from the two distinct groups. A comparison of the two resulting models revealed minor but discernable differences in certain segments of the protein structure, and regions of higher deviation were found to correlate with regions where larger dynamic motions were predicted to occur by normal-mode molecular-dynamics simulations. The findings emphasize that large spatially dependent variations may be present across individual macromolecular crystals. This information can be uncovered by simultaneous analysis of multiple partial data sets and can be exploited to reveal new insights about protein dynamics, while also improving the accuracy of the structure-factor data ultimately obtained in X-ray diffraction experiments.

Thompson, Michael C. (ORCID:0000000260992027)↗