Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC RESONANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Automatic Segmentation of the Eye in 3D Magnetic Resonance Imaging: A Novel Statistical Shape Model for Treatment Planning of Retinoblastoma

Purpose: Proper delineation of ocular anatomy in 3-dimensional (3D) imaging is a big challenge, particularly when developing treatment plans for ocular diseases. Magnetic resonance imaging (MRI) is presently used in clinical practice for diagnosis confirmation and treatment planning for treatment of retinoblastoma in infants, where it serves as a source of information, complementary to the fundus or ultrasonographic imaging. Here we present a framework to fully automatically segment the eye anatomy for MRI based on 3D active shape models (ASM), and we validate the results and present a proof of concept to automatically segment pathological eyes. Methods and Materials: Manual and automatic segmentation were performed in 24 images of healthy children's eyes (3.29 ± 2.15 years of age). Imaging was performed using a 3-T MRI scanner. The ASM consists of the lens, the vitreous humor, the sclera, and the cornea. The model was fitted by first automatically detecting the position of the eye center, the lens, and the optic nerve, and then aligning the model and fitting it to the patient. We validated our segmentation method by using a leave-one-out cross-validation. The segmentation results were evaluated by measuring the overlap, using the Dice similarity coefficient (DSC) and the mean distance error. Results: We obtained a DSC of 94.90 ± 2.12% for the sclera and the cornea, 94.72 ± 1.89% for the vitreous humor, and 85.16 ± 4.91% for the lens. The mean distance error was 0.26 ± 0.09 mm. The entire process took 14 seconds on average per eye. Conclusion: We provide a reliable and accurate tool that enables clinicians to automatically segment the sclera, the cornea, the vitreous humor, and the lens, using MRI. We additionally present a proof of concept for fully automatically segmenting eye pathology. This tool reduces the time needed for eye shape delineation and thus can help clinicians when planning eye treatment and confirming the extent of the tumor.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quality of Intensity Modulated Radiation Therapy Treatment Plans Using a {sup 60}Co Magnetic Resonance Image Guidance Radiation Therapy System

Purpose: This work describes a commercial treatment planning system, its technical features, and its capabilities for creating {sup 60}Co intensity modulated radiation therapy (IMRT) treatment plans for a magnetic resonance image guidance radiation therapy (MR-IGRT) system. Methods and Materials: The ViewRay treatment planning system (Oakwood Village, OH) was used to create {sup 60}Co IMRT treatment plans for 33 cancer patients with disease in the abdominal, pelvic, thorax, and head and neck regions using physician-specified patient-specific target coverage and organ at risk (OAR) objectives. Backup plans using a third-party linear accelerator (linac)-based planning system were also created. Plans were evaluated by attending physicians and approved for treatment. The {sup 60}Co and linac plans were compared by evaluating conformity numbers (CN) with 100% and 95% of prescription reference doses and heterogeneity indices (HI) for planning target volumes (PTVs) and maximum, mean, and dose-volume histogram (DVH) values for OARs. Results: All {sup 60}Co IMRT plans achieved PTV coverage and OAR sparing that were similar to linac plans. PTV conformity for {sup 60}Co was within <1% and 3% of linac plans for 100% and 95% prescription reference isodoses, respectively, and heterogeneity was on average 4% greater. Comparisons of OAR mean dose showed generally better sparing with linac plans in the low-dose range <20 Gy, but comparable sparing for organs with mean doses >20 Gy. The mean doses for all {sup 60}Co plan OARs were within clinical tolerances. Conclusions: A commercial {sup 60}Co MR-IGRT device can produce highly conformal IMRT treatment plans similar in quality to linac IMRT for a variety of disease sites. Additional work is in progress to evaluate the clinical benefit of other novel features of this MR-IGRT system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-AB-BRA-10: Treatment of Gastric MALT Lymphoma Utilizing a Magnetic Resonance Image-Guided Radiation Therapy (MR-IGRT) System: Evaluation of Gating Feasibility

Purpose: To evaluate the feasibility of real-time, real-anatomy tracking and gating for gastric lymphoma patients treated with magnetic resonance image-guided radiation therapy (MR-IGRT) Methods: Over the last 2 years, 8 patients with gastric lymphoma were treated with 0.3-T, Co-60 MR-IGRT. Post-treatment analysis of real-time cine imaging in the sagittal plane during each patient’s treatment revealed significant motion of the stomach. While this motion was accounted for with generous PTV margins, the system’s capability for real-time, real-anatomy tracking could be used to reduce treatment margins by gating. However, analysis was needed for the feasibility of gating using only the single available sagittal imaging plane. While any plane may be chosen, if the stomach moves differently where it is not being observed, there may potentially be a mistreatment. To that end, imaging with healthy volunteers was done to ascertain stomach motion over 2–4 min by analyzing multiple parallel sagittal and coronal planes 0.75 cm apart. The stomach was contoured on every slice, and the mean displacement between pairs of contour centroids was used to determine the amount of overall motion. Results: The mean displacement of the centroid in the image plane was 4.3 ± 0.7 mm. The greatest observed motion was more medial with respect to the patient, and less motion laterally, which implies that gating on a plane located closer to MRI isocenter will provide the more conservative scenario as it will turn the radiation delivery off when the stomach is observed to move outside a predetermined boundary. Conclusion: The stomach was observed to move relatively uniformly throughout, with maximum extent of motion closer to where most MRI systems have the best spatial integrity (near isocenter). Analysis of possible PTV margins from the healthy volunteer study (coupled with previous patient data on interfraction volumetric stomach deformation) is pending.

60 APPLIED LIFE SCIENCES↗

Discrete magic angle turning system, apparatus, and process for in situ magnetic resonance spectroscopy and imaging

Described are a "Discrete Magic Angle Turning" (DMAT) system, devices, and processes that combine advantages of both magic angle turning (MAT) and magic angle hopping (MAH) suitable, e.g., for in situ magnetic resonance spectroscopy and/or imaging. In an exemplary system, device, and process, samples are rotated in a clockwise direction followed by an anticlockwise direction of exactly the same amount. Rotation proceeds through an angle that is typically greater than about 240 degrees but less than or equal to about 360 degrees at constant speed for a time applicable to the evolution dimension. Back and forth rotation can be synchronized and repeated with a special radio frequency (RF) pulse sequence to produce an isotropic-anisotropic shift 2D correlation spectrum. The design permits tubes to be inserted into the sample container without introducing plumbing interferences, further allowing control over such conditions as temperature, pressure, flow conditions, and feed compositions, thus permitting true in-situ investigations to be carried out.

47 OTHER INSTRUMENTATION↗

Magnetic Resonance Imaging Protocol Optimization for Delineation of Gross Tumor Volume in Hypopharyngeal and Laryngeal Tumors

Purpose: To optimize the use of MRI for delineation of gross tumor volume for radiotherapy treatment planning purposes in hypopharyngeal and laryngeal tumors. Methods and Materials: Magnetic resonance images (T1 weighted and T2 weighted) of a healthy volunteer were acquired using a 1.5 T and 3.0 T MR scanner. Various receiver coils were investigated that were compatible with the immobilization mask needed for reliable coregistration with computed tomography data. For the optimal receiver coil, the influence of resolution, slice thickness, and strength of magnetic field on the signal-to-noise ratio (SNR) was studied. Feasibility of the definitive protocol was tested on patients with hypopharyngeal (n = 19) and laryngeal (n = 42) carcinoma. Results: Large differences in SNR were obtained for the various coils. The SNR values obtained using surface coils that were compatible with the immobilization mask were three times higher than those obtained using a standard head-and-neck coil and five times higher than those obtained using a body coil. High-resolution images (0.4 x 0.4 x 4 mm{sup 3}) showed superior anatomic detail and resulted in a 4-min scan time. Image quality at 3.0 T was not significantly better compared with 1.5 T. In 3 patients the MR study could not be performed; for 5 patients images were severely deteriorated by motion artefacts. High-quality MR images were obtained in 53 patients. Conclusions: High-resolution MR images of the hypopharynx and larynx can be obtained in the majority of patients using surface receiver coils in combination with the radiotherapy mask. These MR images can be successfully used for tumor delineation in radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Focal Salvage Guided by T{sub 2}-Weighted and Dynamic Contrast-Enhanced Magnetic Resonance Imaging for Prostate Cancer Recurrences

Purpose: Salvage treatment of the entire prostate for local recurrent cancer after primary radiotherapy is associated with high toxicity rates. Our goal was to show that, using dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) for the visualization of a recurrence, focal salvage treatment can be performed, with, potentially, a reduction in toxicity. Methods and Materials: We performed MRI, including a DCE sequence, in 7 patients with biopsy-proven locally recurrent prostate cancer. The specific regions of interest suspect for containing tumor were delineated using DCE and T{sub 2}-weighted MRI scans. Subsequently, focal salvage high-dose-rate brachytherapy plans were created to illustrate the principle of focal salvage. Total salvage treatment plans were also created for comparison. Results: The transfer constant (K{sup trans}) values from the DCE were 0.33-0.67 min{sup -1} for areas suspect for tumor and 0.07-0.25 min{sup -1} for normal tissue. In 4 cases, a focal salvage plan could be generated; 93-100% of the gross tumor volume was covered with the prescribed dose, with relative sparing of the bladder, rectum, and urethra. In the total salvage plans, 24-53% of the gross tumor volume was covered, and the organs at risk received high doses. In 3 cases, a focal salvage plan could not be created because of multifocal tumor, seminal vesicle extension, or capsular extension. Conclusion: Focal salvage treatment plans can be created in patients with local recurrent prostate cancer after radiotherapy. DCE-MRI supports the localization of the target area. This could lead to less toxicity in patients with local recurrent prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Resting myocardial blood flow quantification using contrast-enhanced magnetic resonance imaging in the presence of stenosis: A computational fluid dynamics study

Purpose: The extent to which atherosclerotic plaques affect contrast agent (CA) transport in the coronary arteries and, hence, quantification of myocardial blood flow (MBF) using magnetic resonance imaging (MRI) is unclear. The purpose of this work was to evaluate the influence of plaque induced stenosis both on CA transport and on the accuracy of MBF quantification. Methods: Computational fluid dynamics simulations in a high-detailed realistic vascular model were employed to investigate CA bolus transport in the coronary arteries. The impact of atherosclerosis was analyzed by inserting various medium- to high-grade stenoses in the vascular model. The influence of stenosis morphology was examined by varying the stenosis shapes but keeping the area reduction constant. Errors due to CA bolus transport were analyzed using the tracer-kinetic model MMID4. Results: Dispersion of the CA bolus was found in all models and for all outlets, but with a varying magnitude. The impact of stenosis was complex: while high-grade stenoses amplified dispersion, mild stenoses reduced the effect. Morphology was found to have a marked influence on dispersion for a small number of outlets in the post-stenotic region. Despite this marked influence on the concentration–time curves, MBF errors were less affected by stenosis. In total, MBF was underestimated by −7.9% to −44.9%. Conclusions: The presented results reveal that local hemodynamics in the coronary vasculature appears to have a direct impact on CA bolus dispersion. Inclusion of atherosclerotic plaques resulted in a complex alteration of this effect, with both degree of area reduction and stenosis morphology affecting the amount of dispersion. This strong influence of vascular transport effects impairs the accuracy of MRI-based MBF quantification techniques and, potentially, other bolus-based perfusion measurement techniques like computed tomography perfusion imaging.

60 APPLIED LIFE SCIENCES↗

Development of Operando Nuclear Magnetic Resonance Capabilities for Solid-State Battery Research

Mechanistic information regarding solid-solid interfaces in solid-state batteries remains elusive as its observation requires a non-destructive operando technique. Such a technique does not currently exist. Solid-state nuclear magnetic resonance (NMR) is uniquely suited to address this challenge as it is sensitive to chemistry, structure, and dynamics and can measure buried interfaces. However solid-state NMR requires high speed spinning of the sample at the ‘magic angle’ (MAS) to obtain adequate resolution. The metallic current collectors in a battery are detrimental to spinning in magnetic fields as they generate eddy currents which prevent spinning and dampen the NMR signal. Furthermore, the spinning nature of the MAS NMR experiment requires a wireless means of charging for operando capabilities. These challenges were addressed in this research and operando MAS NMR enabled by optical wireless charging was demonstrated. By limiting the size of the metallic components, we were able to spin a sample holder with electrical leads and a solid-state battery up to a few kilohertz, fast enough for high-resolution NMR. We achieved wireless charging by attaching a photovoltaic cell to the head of the NMR rotor and used a laser to transmit power to the photovoltaic cell. Demonstration of the optical wireless charging was performed by polarizing a liquid electrolyte during an operando MAS NMR measurement. This novel capability is a transformative technique for investigating the mechanistic electrochemical processes in solid-state samples.

25 ENERGY STORAGE↗

Self‐gated, dynamic contrast‐enhanced magnetic resonance imaging with compressed‐sensing reconstruction for evaluating endothelial permeability in the aortic root of atherosclerotic mice

High‐risk atherosclerotic plaques are characterized by active inflammation and abundant leaky microvessels. We present a self‐gated, dynamic contrast‐enhanced magnetic resonance imaging (DCE‐MRI) acquisition with compressed sensing reconstruction and apply it to assess longitudinal changes in endothelial permeability in the aortic root of Apoe −/− atherosclerotic mice during natural disease progression. Twenty‐four, 8‐week‐old, female Apoe −/− mice were divided into four groups (n = 6 each) and imaged with self‐gated DCE‐MRI at 4, 8, 12, and 16 weeks after high‐fat diet initiation, and then euthanized for CD68 immunohistochemistry for macrophages. Eight additional mice were kept on a high‐fat diet and imaged longitudinally at the same time points. Aortic‐root pseudo‐concentration curves were analyzed using a validated piecewise linear model. Contrast agent wash‐in and washout slopes ( b 1 and b 2 ) were measured as surrogates of aortic root endothelial permeability and compared with macrophage density by immunohistochemistry. b 2 , indicating contrast agent washout, was significantly higher in mice kept on an high‐fat diet for longer periods of time ( p = 0.03). Group comparison revealed significant differences between mice on a high‐fat diet for 4 versus 16 weeks ( p = 0.03). Macrophage density also significantly increased with diet duration ( p = 0.009). Spearman correlation between b 2 from DCE‐MRI and macrophage density indicated a weak relationship between the two parameters (r = 0.28, p = 0.20). Validated piecewise linear modeling of the DCE‐MRI data showed that the aortic root contrast agent washout rate is significantly different during disease progression. Further development of this technique from a single‐slice to a 3D acquisition may enable better investigation of the relationship between in vivo imaging of endothelial permeability and atherosclerotic plaques' genetic, molecular, and cellular makeup in this important model of disease.

Calcagno, Claudia↗

Two-fluid nonlinear theory of response of tokamak plasma to resonant magnetic perturbation

A comprehensive two-fluid nonlinear theory of magnetic reconnection driven at a single, tearing-stable, rational surface embedded in an H-mode tokamak plasma is presented. The surface is assumed to be resonant with one of the dominant helical harmonics of an applied resonant magnetic perturbation (RMP). Finally, the theory described in this paper is highly relevant to the problem of understanding the physics of RMP-induced edge localized mode suppression in tokamak plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic resonance induced pseudoelectric field and giant current response in axion insulators

Here, a quantized version of the magnetoelectric effect, known as the topological magnetoelectric effect, can exist in a time-reversal invariant topological insulator with all its surface states gapped out by magnetism. This topological phase, called the axion insulator phase, has been theoretically proposed but still lacks conclusive experimental evidence due to the small signal of topological magnetoelectric effect. In this work, we propose that the dynamical in-plane magnetization in an axion insulator can generate a pseudoelectric field, which acts on the surface state of topological insulator films and leads to the nonzero response current. Strikingly, we find that the current at magnetic resonance (either ferromagnetic or antiferromagnetic) is larger than that of topological magnetoelectric effect by several orders of magnitude and thereby serves as evidence to confirm the axion insulator phase in the candidate materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Comparing the Detectability of Hepatocellular Carcinoma by C-Arm Dual-Phase Cone-Beam Computed Tomography During Hepatic Arteriography With Conventional Contrast-Enhanced Magnetic Resonance Imaging

Purpose: To evaluate the sensitivity of dual-phase cone-beam computed tomography during hepatic arteriography (CBCTHA) for the detection of hepatocellular carcinoma (HCC) by comparing it with the diagnostic imaging 'gold standard': contrast-enhanced magnetic resonance imaging (CE-MRI) of the liver. Materials and Methods: Eighty-eight HCC lesions (mean diameter 3.9 {+-} 3.3 cm) in 20 patients (13 men, mean age 61.4 years [range 50 to 80]), who sequentially underwent baseline diagnostic liver CE-MRI and then underwent early arterial- and delayed portal venous-phase CBCTHA during drug eluting-bead transarterial chemoembolization, were evaluated. Dual-phase CBCTHA findings of each tumor in terms of conspicuity were compared with standard CE-MR images and classified into three grades: optimal, suboptimal, and nondiagnostic. Results: Seventy-seven (mean diameter 4.2 {+-} 3.4 cm [range 0.9 to 15.9]) (93.9%) of 82 tumors were detected. Sensitivity of arterial-phase (71.9%) was lower than that of venous-phase CBCTHA (86.6%) for the detection of HCC lesions. Of the 82 tumors, 33 (40.2%) and 52 (63.4%), 26 (31.7%) and 19 (23.2%), and 23 (28%) and 11 (13.4%) nodules were classed as optimal, suboptimal, and nondiagnostic on arterial- and venous-phase CBCTHA images, respectively. Seventeen (73.9%) of the 23 tumors that were not visible on arterial phase were detected on venous phase. Six (54.5%) of the 11 tumors that were not visible on venous phase were detected on arterial phase. Conclusions: Dual-phase CBCTHA has sufficient image quality to detect the majority of HCC lesions compared with the imaging 'gold standard': CE-MRI of the liver. Moreover, dual-phase CBCTHA is more useful and reliable than single-phasic imaging to depict HCC nodules.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cardiac Magnetic Resonance Imaging Findings in 20-year Survivors of Mediastinal Radiotherapy for Hodgkin's Disease

Purpose: The recognition of the true prevalence of cardiac toxicity after mediastinal radiotherapy requires very long follow-up and a precise diagnostic procedure. Cardiac magnetic resonance imaging (MRI) permits excellent quantification of cardiac function and identification of localized myocardial defects and has now been applied to a group of 20-year Hodgkin's disease survivors. Methods and materials: Of 143 patients treated with anterior mediastinal radiotherapy (cobalt-60, median prescribed dose 40 Gy) for Hodgkin's disease between 1978 and 1985, all 53 survivors were invited for cardiac MRI. Of those, 36 patients (68%) presented for MRI, and in 31 patients (58%) MRI could be performed 20-28 years (median, 24) after radiotherapy. The following sequences were acquired on a 1.5-T MRI: transversal T1-weighted TSE and T2-weighted half-fourier acquisition single-shot turbo-spin-echo sequences, a steady-state free precession (SSFP) cine sequence in the short heart axis and in the four-chamber view, SSFP perfusion sequences under rest and adenosine stress, and a SSFP inversion recovery sequence for late enhancement. The MRI findings were correlated with previously reconstructed doses to cardiac structures. Results: Clinical characteristics and reconstructed doses were not significantly different between survivors undergoing and not undergoing MRI. Pathologic findings were reduced left ventricular function (ejection fraction <55%) in 7 (23%) patients, hemodynamically relevant valvular dysfunction in 13 (42%), late myocardial enhancement in 9 (29%), and any perfusion deficit in 21 (68%). An association of regional pathologic changes and reconstructed dose to cardiac structures could not be established. Conclusions: In 20-year survivors of Hodgkin's disease, cardiac MRI detects pathologic findings in approximately 70% of patients. Cardiac MRI has a potential role in cardiac imaging of Hodgkin's disease patients after mediastinal radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Grade Glioma Radiation Therapy Target Volumes and Patterns of Failure Obtained From Magnetic Resonance Imaging and {sup 18}F-FDOPA Positron Emission Tomography Delineations From Multiple Observers

Purpose: The objective of this study was to compare recurrent tumor locations after radiation therapy with pretreatment delineations of high-grade gliomas from magnetic resonance imaging (MRI) and 3,4-dihydroxy-6-[{sup 18}F]fluoro-L-phenylalanine ({sup 18}F-FDOPA) positron emission tomography (PET) using contours delineated by multiple observers. Methods and Materials: Nineteen patients with newly diagnosed high-grade gliomas underwent computed tomography (CT), gadolinium contrast-enhanced MRI, and {sup 18}F-FDOPA PET/CT. The image sets (CT, MRI, and PET/CT) were registered, and 5 observers contoured gross tumor volumes (GTVs) using MRI and PET. Consensus contours were obtained by simultaneous truth and performance level estimation (STAPLE). Interobserver variability was quantified by the percentage of volume overlap. Recurrent tumor locations after radiation therapy were contoured by each observer using CT or MRI. Consensus recurrence contours were obtained with STAPLE. Results: The mean interobserver volume overlap for PET GTVs (42% ± 22%) and MRI GTVs (41% ± 22%) was not significantly different (P=.67). The mean consensus volume was significantly larger for PET GTVs (58.6 ± 52.4 cm{sup 3}) than for MRI GTVs (30.8 ± 26.0 cm{sup 3}, P=.003). More than 95% of the consensus recurrence volume was within the 95% isodose surface for 11 of 12 (92%) cases with recurrent tumor imaging. Ten (91%) of these cases extended beyond the PET GTV, and 9 (82%) were contained within a 2-cm margin on the MRI GTV. One recurrence (8%) was located outside the 95% isodose surface. Conclusions: High-grade glioma contours obtained with {sup 18}F-FDOPA PET had similar interobserver agreement to volumes obtained with MRI. Although PET-based consensus target volumes were larger than MRI-based volumes, treatment planning using PET-based volumes may not have yielded better treatment outcomes, given that all but 1 recurrence extended beyond the PET GTV and most were contained by a 2-cm margin on the MRI GTV.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patterns of Primary Tumor Invasion and Regional Lymph Node Spread Based on Magnetic Resonance Imaging in Early-Stage Nasal NK/T-cell Lymphoma: Implications for Clinical Target Volume Definition and Prognostic Significance

Purpose: This study aimed to determine the pathways of primary tumor invasion (PTI) and regional lymph node (LN) spread based on magnetic resonance imaging (MRI) in early-stage nasal NK/T-cell lymphoma (NKTCL), to improve clinical target volume (CTV) delineation and evaluate the prognostic value of locoregional extension patterns. Methods and Materials: A total of 105 patients with newly diagnosed early-stage nasal NKTCL who underwent pretreatment MRI were retrospectively reviewed. All patients received radiation therapy with or without chemotherapy. Results: The incidences of PTI and regional LN involvement were 64.7% and 25.7%, respectively. Based on the incidence of PTI, involved sites surrounding the nasal cavity were classified into 3 risk subgroups: high-risk (>20%), intermediate-risk (5%-20%), and low-risk (<5%). The most frequently involved site was the nasopharynx (35.2%), followed by the maxillary (21.9%) and ethmoid (21.9%) sinuses. Local disease and regional LN spread followed an orderly pattern without LN skipping. The retropharyngeal nodes (RPNs) were most frequently involved (19.0%), followed by level II (11.4%). The 5-year overall survival (OS), progression-free survival (PFS), and locoregional control (LRC) rates for all patients were 72.8%, 65.2%, and 90.0%, respectively. The presence of PTI and regional LN involvement based on MRI significantly and negatively affected PFS and OS. Conclusions: Early-stage nasal NKTCL presents with a high incidence of PTI but a relatively low incidence of regional LN spread. Locoregional spread followed an orderly pattern, and PTI and regional LN spread are powerful prognostic factors for poorer survival outcomes. CTV reduction may be feasible for selected patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Solution-state structure and affinities of cyclodextrin: Fentanyl complexes by nuclear magnetic resonance spectroscopy and molecular dynamics simulation

Cyclodextrins (CDs) are investigated for their ability to form inclusion complexes with the analgesic fentanyl and three similar molecules: acetylfentanyl, thiofentanyl, and acetylthiofentanyl. Stoichiometry, binding strength, and complex structure are revealed through nuclear magnetic resonance (NMR) techniques and discussed in terms of molecular dynamics (MD) simulations. It was found that β-cyclodextrin is generally capable of forming the strongest complexes with the fentanyl panel. Two-dimensional NMR data and computational chemical calculations are used to derive solution-state structures of the complexes. Binding of the fentanyls to the CDs occurs at the amide phenyl ring, leaving the majority of the molecule solvated by water, an observation common to all four fentanyls. This finding suggests a universal binding behavior, as the vast majority of previously synthesized fentanyl analogues contain this structural moiety. Furthermore, this baseline study serves as the most complete work on CD:fentanyl complexes to date and provides the insights into strategies for producing future generations of designer cyclodextrins capable of stronger and more selective complexation of fentanyl and its analogues.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nucleon polarizabilities and {Delta}-resonance magnetic moment in chiral EFT

Recent chiral EFT calculations of nucleon polarizabilities reveal a problem in the current empirical determination of proton's electromagnetic polarizabilities. We also report on the progress in the empirical determination of the {Delta}(1232)-resonance magnetic moment in the process of {gamma}p{yields}p{pi}{sup 0}{gamma}' measured at MAMI.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Selective One-Dimensional 13 C– 13 C Spin-Diffusion Solid-State Nuclear Magnetic Resonance Methods to Probe Spatial Arrangements in Biopolymers Including Plant Cell Walls, Peptides, and Spider Silk

Two-dimensional (2D) and 3D through-space 13 C– 13 C homonuclear spin-diffusion techniques are powerful solid-state nuclear magnetic resonance (NMR) tools for extracting structural information from 13 C-enriched biomolecules, but necessarily long acquisition times restrict their applications. In this work, we explore the broad utility and underutilized power of a chemical shift-selective one-dimensional (1D) version of a 2D 13 C– 13 C spin-diffusion solid-state NMR technique. The method, which is called 1D dipolar-assisted rotational resonance (DARR) difference, is applied to a variety of biomaterials including lignocellulosic plant cell walls, microcrystalline peptide fMLF, and black widow dragline spider silk. 1D 13 C– 13 C spin-diffusion methods described here apply in select cases in which the 1D 13 C solid-state NMR spectrum displays chemical shift-resolved moieties. Furthermore, this is analogous to the selective 1D nuclear Overhauser effect spectroscopy (NOESY) experiment utilized in liquid-state NMR as a faster (1D instead of 2D) and often less ambiguous (direct sampling of the time domain data, coupled with increased signal averaging) alternative to 2D NOESY. Selective 1D 13 C– 13 C spin-diffusion methods are more time-efficient than their 2D counterparts such as proton-driven spin diffusion (PDSD) and dipolar-assisted rotational resonance. The additional time gained enables measurements of 13 C– 13 C spin-diffusion buildup curves and extraction of spin-diffusion time constants TSD, yielding detailed structural information. Specifically, selective 1D DARR difference buildup curves applied to 13 C-enriched hybrid poplar woody stems confirm strong spatial interaction between lignin and acetylated xylan polymers within poplar plant secondary cell walls, and an interpolymer distance of ~0.45–0.5 nm was estimated. Additionally, Tyr/Gly long-range correlations were observed on isotopically enriched black widow spider dragline silks.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗