Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETOMETERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Unlocking Solutions: Innovative Approaches to Identifying and Mitigating the Environmental Impacts of Undocumented Orphan Wells in the United States

In the United States, hundreds of thousands of undocumented orphan wells have been abandoned, leaving the burden of managing environmental hazards to governmental agencies or the public. These wells, a result of over a century of fossil fuel extraction without adequate regulation, lack basic information like location and depth, emit greenhouse gases, and leak toxic substances into groundwater. For most of these wells, basic information such as well location and depth is unknown or unverified. Addressing this issue necessitates innovative and interdisciplinary approaches for locating, characterizing, and mitigating their environmental impacts. Our survey of the United States revealed the need for tools to identify well locations and assess conditions, prompting the development of technologies including machine learning to automatically extract information from old records (95%+ accuracy), remote sensing technologies like aero-magnetometers to find buried wells, and cost-effective methods for estimating methane emissions. Notably, fixed-wing drones equipped with magnetometers have emerged as cost-effective and efficient for discovering unknown wells, offering advantages over helicopters and quadcopters. Efforts also involved leveraging local knowledge through outreach to state and tribal governments as well as citizen science initiatives. These initiatives aim to significantly contribute to environmental sustainability by reducing greenhouse gases and improving air and water quality.

54 ENVIRONMENTAL SCIENCES↗

MAGDAS Project for Space Weather Research and Application

The Space Environment Research Center (SERC), Kyushu University, is currently deploying a new ground-based magnetometer network of MAGnetic Data Acqusition System (MAGDAS), in cooperation with about 30 organizations in the world, in order to understand the complex Sun-Earth system for space weather research and application. SERC will conducts MAGDAS observation at 50 stations in the Circum-pan Pacific Magnetometer Network (CPMN) region, and FM-CW radar observation along the 210 deg. magnetic meridian (MM) during the IHY/ILWS/CAWSES periods. This project is actively providing the following space weather monitoring:(1) Global 3-dimensional current system to know electromagnetic coupling of the region 1 and 2 field-aligned currents, auroral electrojet current, Sq current, and equatorial electrojet current. (2) Plasma mass density along the 210 deg. MM to understand plasma environment change during space storms. (3) Ionospheric electric field intensity with 10-sec sampling at L = 1.26 to understand how the external electric field penetrates into the equatorial ionosphere.

79 ASTRONOMY AND ASTROPHYSICS↗

Structure and magnetic properties of irradiated Fe/Fe oxide core-shell nanoclusters

A cluster deposition method was used to produce a film of loosely aggregated particles of Fe-Fe3O4 core-shell nanoclusters with an 8 nm iron core size and 2 nm oxide shell thickness. The film of particles on a silicon substrate was irradiated with 5.5 MeV Si2+ ions to a fluence of 1016 cm-2 near room temperature, and computer simulations based on the SRIM (Stopping and Range of Ions in Matter) code show that the implanted Si species stops near the film-substrate interface. The ion irradiation creates a structural change in the film with corresponding chemical and magnetic changes. X-ray diffraction shows that the core size and chemistry stay the same but the shell becomes FeO that grows to a thickness of 17 nm. Helium ion microscopy shows that the previously separate particles have densified into a nearly continuous film. Major loop magnetic hysteresis measurements show a decrease in saturation magnetization that we attribute to the presence of the antiferromagnetic (AFM) FeO shell. First-order reversal curve measurements on the irradiated film performed with a vibrating sample magnetometer show that the AFM shell prevents the particles from interacting magnetically, leading to low coercivity from the iron core and little bias field from the core interactions. These results, and others reported previously on different compositions (Fe3O4 or FeO+Fe3N nanoclusters), show that the ion irradiation behavior of nanocluster films such as these depends strongly on the initial nanostructure and chemistry.

Environmental Molecular Sciences Laboratory↗

Magnetic switching behaviors of orbital states with different magnetic quantum numbers in Au/Fe/MgO multilayer system

A spin specific magnetic hysteresis (SSMH) curve and an orbital specific magnetic hysteresis (OSMH) curve are obtained for Fe/Au/Fe/MgO multilayers by magnetic Compton scattering and SQUID magnetometer measurements. The SSMH curve with each contribution of magnetic quantum number |m| = 0, 1, and 2 states is obtained by decomposition analyses of magnetic Compton profiles. Residual magnetization is observed for the SSMH curve with magnetic quantum number |m| = 0, 2 and the OSMH curve. Although the SQUID magnetometer measurements do not show perpendicular magnetic anisotropy (PMA) in the present Fe/Au/Fe/MgO multilayer film, the SSMH curve with magnetic quantum number |m| = 0, 2 and OSMH curve show switching behaviors of PMA.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Plasma-satellite interaction driven magnetic field perturbations

We report the first fully kinetic quantitative estimate of magnetic field perturbations caused by the interaction of a spacecraft with space environment. Such perturbations could affect measurements of geophysical magnetic fields made with very sensitive magnetometers on-board satellites. Our approach is illustrated with a calculation of perturbed magnetic fields near the recently launched Swarm satellites. In this case, magnetic field perturbations do not exceed 20 pT, and they are below the sensitivity threshold of the on-board magnetometers. Anticipating future missions in which satellites and instruments would be subject to more intense solar UV radiation, however, it appears that magnetic field perturbations associated with satellite interaction with space environment, might approach or exceed instruments' sensitivity thresholds.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Zn interstitial defects induced magnetic nature in Fe ions doped ZnO based DMS

This paper describes the synthesis of Fe doped ZnO samples Zn{sub 1-x}Fe{sub x}0, where x various from 0.01≤x≤0.05 (in steps of 0.01) by solution method. The effect of Fe ions doping on the structural, optical and magnetic properties was investigated using X-ray diffraction (XRD), Photoluminescence and vibrating sample magnetometer (VSM) measurements. The observed result indicates that the samples are single phase formation of the wurtzite structure without any significant secondary phase in it. The photoluminescence spectra reveals the presence of Zn vacancies. The magnetic property of prepared samples was studied using a vibrating sample magnetometer and the observed results revealed a super-paramagnetic behavior for the Fe doped ZnO samples.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

FIP effect for minor heavy solar wind ions as seen with SOHO/CELIAS/MTOF

A recent paper [Shearer et al., 2014] reported that during solar maximum Ne showed a surprisingly low abundance. This leads to the question whether other elements show the same behavior. The good mass resolution of Mass-Time-Of-Flight (MTOF) as part of the Charge ELement and Isotope Analysis System (CELIAS) on the Solar Helioshperic Observatory (SOHO) allows to investigate the composition of heavy minor elements in different types of solar wind. We restrict this study to slow solar wind, where the characterisation of slow solar wind is taken from Xu and Borovsky, 2014. This classification scheme requires magnet field information. Since SOHO does not carry a magnetometer, we use the Magnetometer (MAG) of the Advanced Composition Explorer (ACE) instead. The Solar Wind Ion Composition Spectrometer (ACE/SWICS) also provides composition data for cross-calibration and charge-state distributions as input for the transmission function of MTOF whenever the two spacecraft can be expected to observe the same type of wind. We illustrate the MTOF’s capability to determine the solar wind abundance compared to the photospheric abundance (called the FIP ratio in the following) for rare elements like Ti or Cr on long-time scales as a proof of concept for our analysis. And in this brief study, measurements with both ACE/SWICS indicate that the observed elements exhibit a (weak) dependence on the solar cycle, whereas the MTOF measurements are inconclusive.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of oxygen plasma etching on Sb{sub 2}Te{sub 3} explored by torque detected quantum oscillations

De Haas–van Alphen measurements evidence that oxygen plasma etching strongly affects the properties of the three-dimensional topological insulator Sb{sub 2}Te{sub 3}. The quantum oscillations in magnetization down to low temperature (T ≥ 2 K) and high magnetic field (B ≤ 7 T) have been systematically investigated using a high-sensitive cantilever torque magnetometer. The effective mass and the oscillation frequency obtained from de Haas–van Alphen measurements first increase and then decrease as the oxygen plasma etching time increases from 0 to 12 min, corresponding to an up- and down-shift of the Dirac point. We establish the cantilever torque magnetometer as a powerful contactless tool to investigate the oxygen sensitivity of the surface state in topological insulators.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spin-exchange relaxation-free magnetometry using elliptically polarized light

Spin-exchange relaxation free alkali-metal magnetometers typically operate in the regime of high optical density, presenting challenges for simple and efficient optical pumping and detection. We describe a high-sensitivity Rb magnetometer using a single elliptically polarized off-resonant laser beam. Circular component of the light creates relatively uniform spin polarization while the linear component is used to measure optical rotation generated by the atoms. Modulation of the atomic spin direction with an oscillating magnetic field shifts the detected signal to high frequencies. Using a fiber-coupled distributed feedback laser, we achieve magnetic field sensitivity of 7 fT/{radical}(Hz) with a miniature 5x5x5 mm Rb vapor cell.

74 ATOMIC AND MOLECULAR PHYSICS↗

Vector magnetometry based on electromagnetically induced transparency in linearly polarized light

We develop a generalized principle of electromagnetically induced transparency (EIT) vector magnetometry based on high-contrast EIT resonances and the symmetry of atom-light interaction in the linearly polarized bichromatic fields. Operation of such vector magnetometer on the D{sub 1} line of {sup 87}Rb has been demonstrated. The proposed compass-magnetometer has an increased immunity to shifts produced by quadratic Zeeman and ac-Stark effects, as well as by atom-buffer gas and atom-atom collisions. In our proof-of-principle experiment the detected angular sensitivity to magnetic field orientation is 10{sup -3} deg/Hz{sup 1/2}, which is limited by laser intensity fluctuations, light polarization quality, and magnitude of the magnetic field.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Recent Findings from Restored Apollo Magnetic Field Records

On November 19, 1969, Apollo 12 astronauts installed a Lunar Surface Magnetometer (LSM) as a part ofthe Apollo Lunar Surface Experiment Package, making the first magnetic field measurement on aplanetary body other than Earth. The subsequent Apollo missions deployed two more LSM's (Apollos 15and 16), two Lunar Portable Magnetometers (Apollos 14 and 15), and two Sub-satellite BiaxialMagnetometers (SBMs of Apollos 15 and 16). After almost a half century, the Apollo 15 and 16 missionsare still the only lunar missions conducting simultaneous surface and orbital magnetic field experiments.The Apollo magnetic field experiments enabled many first discoveries, including the lunar magneticanomalies and the electrical conductivity of the Moon. Since the Apollo era, the archaic data format hasbeen hampering the re-examination of Apollo magnetic field records until recently. We have nowrestored most of the digital Apollo magnetic field records archived at NSSDC, including the 0.3-s datafrom the Apollo 12, 15 and 16 LSMs and the 24-s data from Apollo 15 and 16 SBMs. The restored LSMdata have revealed many narrowband ion cyclotron waves in the Earth's magnetotail that were not

Magnetic↗

Relativistic electron response to the combined magnetospheric impact of a coronal mass ejection overlapping with a high-speed stream: Van Allen Probes observations

During early November 2013, the magnetosphere experienced concurrent driving by a coronal mass ejection (CME) during an ongoing high-speed stream (HSS) event. The relativistic electron response to these two kinds of drivers, i.e., HSS and CME, is typically different, with the former often leading to a slower buildup of electrons at larger radial distances, while the latter energizing electrons rapidly with flux enhancements occurring closer to the Earth. In this paper, we present a detailed analysis of the relativistic electron response including radial profiles of phase space density as observed by both Magnetic Electron and Ion Sensor (MagEIS) and Relativistic Electron Proton Telescope instruments on the Van Allen Probes mission. Data from the MagEIS instrument establish the behavior of lower energy (<1 MeV) electrons which span both intermediary and seed populations during electron energization. Measurements characterizing the plasma waves and magnetospheric electric and magnetic fields during this period are obtained by the Electric and Magnetic Field Instrument Suite and Integrated Science instrument on board Van Allen Probes, Search Coil Magnetometer and Flux Gate Magnetometer instruments on board Time History of Events and Macroscale Interactions during Substorms, and the low-altitude Polar-orbiting Operational Environmental Satellites. These observations suggest that during this time period, both radial transport and local in situ processes are involved in the energization of electrons. Finally, the energization attributable to radial diffusion is most clearly evident for the lower energy (<1 MeV) electrons, while the effects of in situ energization by interaction of chorus waves are prominent in the higher-energy electrons.

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental limit on an exotic parity-odd spin- and velocity-dependent interaction using an optically polarized vapor

Abstract Exotic spin-dependent interactions between fermions have recently attracted attention in relation to theories beyond the Standard Model. The exotic interactions can be mediated by hypothetical fundamental bosons which may explain several unsolved mysteries in physics. Here we expand this area of research by probing an exotic parity-odd spin- and velocity-dependent interaction between the axial-vector electron coupling and the vector nucleon coupling for polarized electrons. This experiment utilizes a high-sensitivity atomic magnetometer, based on an optically polarized vapor that is a source of polarized electrons, and a solid-state mass containing unpolarized nucleons. The atomic magnetometer can detect an effective magnetic field induced by the exotic interaction between unpolarized nucleons and polarized electrons. We set an experimental limit on the electron-nucleon coupling $$g_{\mathrm{A}}^{\mathrm{e}}g_{\mathrm{V}}^{\mathrm{N}} \, < \, 10^{ - 30}$$ g A e g V N < 1 0 - 30 at the mediator boson mass below 10 −4 eV, significantly improving the current limit by up to 17 orders of magnitude.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Imaging viscous flow of the Dirac fluid in graphene

The electron–hole plasma in charge-neutral graphene is predicted to realize a quantum critical system in which electrical transport features a universal hydrodynamic description, even at room temperature. This quantum critical ‘Dirac fluid’ is expected to have a shear viscosity close to a minimum bound, with an interparticle scattering rate saturating1 at the Planckian time, the shortest possible timescale for particles to relax. Although electrical transport measurements at finite carrier density are consistent with hydrodynamic electron flow in graphene a clear demonstration of viscous flow at the charge-neutrality point remains elusive. In this work, we directly image viscous Dirac fluid flow in graphene at room temperature by measuring the associated stray magnetic field. Nanoscale magnetic imaging is performed using quantum spin magnetometers realized with nitrogen vacancy centres in diamond. Scanning single-spin and wide-field magnetometry reveal a parabolic Poiseuille profile for electron flow in a high-mobility graphene channel near the charge-neutrality point, establishing the viscous transport of the Dirac fluid. This measurement is in contrast to the conventional uniform flow profile imaged in a metallic conductor and also in a low-mobility graphene channel. Furthermore, via combined imaging and transport measurements, we obtain viscosity and scattering rates, and observe that these quantities are comparable to the universal values expected at quantum criticality. This finding establishes a nearly ideal electron fluid in charge-neutral, high-mobility graphene at room temperature4. Our results will enable the study of hydrodynamic transport in quantum critical fluids relevant to strongly correlated electrons in high-temperature superconductors9. This work also highlights the capability of quantum spin magnetometers to probe correlated electronic phenomena at the nanoscale.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

High-Sensitivity rf Detection Using an Optically Pumped Comagnetometer Based on Natural-Abundance Rubidium with Active Ambient-Field Cancellation

To detect a specific radio-frequency (rf) magnetic field, rf optically pumped magnetometers (OPMs) require a static magnetic field to set the Larmor frequency of the atoms equal to the frequency of interest. However, unshielded and variable magnetic field environments (e.g., an rf OPM on a moving platform) pose a problem for rf OPM operation. Here, we demonstrate the use of a natural-abundance rubidium vapor to make a comagnetometer to address this challenge. Our implementation builds upon the simultaneous application of several OPM techniques within the same vapor cell. First, we use a modified implementation of an OPM variometer based on 87 Rb to detect and actively cancel unwanted external fields at frequencies ≲60 Hz using active feedback to a set of field control coils. In this experiment, we exploit this stabilized field environment to implement a high-sensitivity rf magnetometer using 85 Rb. Using this approach, we demonstrate the ability to measure rf fields with a sensitivity of approximately 9 fT Hz -1/2 inside a magnetic shield in the presence of an applied field of approximately 20 μT along three mutually orthogonal directions. This demonstration opens up a path toward completely unshielded operation of a high-sensitivity rf OPM.

47 OTHER INSTRUMENTATION↗

Absolute Magnetometry with He3

We report development of a highly accurate (parts per billion) absolute magnetometer based on 3He NMR. Optical pumping polarizes the spins, long coherence times provide high sensitivity, and the 3He electron shell effectively isolates the nuclear spin providing accuracy limited only by corrections including materials, sample shape, and magnetization. Our magnetometer was used to confirm calibration, to 32 ppb, of the magnetic-field sensors used in recent measurements of the muon magnetic moment anomaly g-2, which differs from the standard model by 2.4 ppm. With independent determination of the magnetic moment of 3He, this work will lead the way to a new absolute magnetometry standard.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Surpassing the Energy Resolution Limit with Ferromagnetic Torque Sensors

We discuss the fundamental noise limitations of a ferromagnetic torque sensor based on a levitated magnet in the tipping regime. We evaluate the optimal magnetic field resolution taking into account the thermomechanical noise and the mechanical detection noise at the standard quantum limit. We find that the energy resolution limit, pointed out in recent literature as a relevant benchmark for most classes of magnetometers, can be surpassed by many orders of magnitude. Moreover, similarly to the case of a ferromagnetic gyroscope, it is also possible to surpass the standard quantum limit for magnetometry with independent spins, arising from spin-projection noise. Our finding indicates that magnetomechanical systems optimized for magnetometry can achieve a magnetic field resolution per unit volume several orders of magnitude better than any conventional magnetometer. Here, we discuss possible implications, focusing on fundamental physics problems such as the search for exotic interactions beyond the standard model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Impact of remanent magnetic field on the heat load of original CEBAF cryomodule

The heat load of the original cryomodules for the CEBAF accelerator is ~50% higher than the target value of 100 W at 2.07 K for refurbished cavities operating at an accelerating gradient of 12.5 MV/m. This issue is due to the quality factor of the cavities being ~50% lower in the cryomodule than when tested in a vertical cryostat, even at low RF field. Previous studies were not conclusive about the origin of the additional losses. We present the results of a systematic study of the additional losses in a five-cell cavity from a decommissioned cryomodule after attaching components, which are part of the cryomodule, such as the cold tuner, the He tank and the cold magnetic shield, prior to cryogenic testing in a vertical cryostat. Flux-gate magnetometers and temperature sensors are used as diagnostic elements. Different cool-down procedures and tests in different residual magnetic fields were investigated during the study. Here, three flux-gate magnetometers attached to one of the cavities installed in the refurbished cryomodule C50-12 confirmed the hypothesis of high residual magnetic field as a major cause for the increased RF losses.

43 PARTICLE ACCELERATORS↗