Search NASA⌕ Search

SEARCH · Search NASA

Results for “Magnetometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Engineering diamond interfaces free of dark spins

Nitrogen-vacancy (NV) centers in diamond are utilized extensively as quantum sensors for imaging fields at the nanoscale. The ultrahigh sensitivity of NV magnetometers has enabled the detection and spectroscopy of individual electron spins, with potentially far-reaching applications in condensed matter physics, spintronics, and molecular biology. However, the surfaces of these diamond sensors naturally contain electron spins, which create a background signal that can be hard to differentiate from the signal of the target spins. In this study, we develop a surface modification approach that eliminates the unwanted signal of these so-called dark electron spins. Our surface passivation technique, based on coating diamond surfaces with a thin titanium oxide (Ti⁢O 2 ) layer, reduces the dark spin density. The observed reduction in dark spin density aligns with our findings on the electronic structure of the diamond-Ti⁢O 2 interface. The reduction, from a typical value of 2000 μm −2 to a value below that set by the detection limit of our NV sensors (200 μm −2 ), results in a twofold increase in Hahn-echo coherence time of near surface NV centers. Furthermore, we derive a comprehensive spin model that connects dark spin relaxation with NV coherence, providing additional insights into the mechanisms behind the observed spin dynamics. Our findings are directly transferable to other quantum platforms, including nanoscale solid-state qubits and superconducting qubits.

74 ATOMIC AND MOLECULAR PHYSICS↗

Variational quantum state preparation for quantum-enhanced metrology in noisy systems

Here, we investigate optimized quantum state preparation for quantum metrology applications in noisy environments. Using the QFI-OPT package, we simulate a low-depth variational quantum circuit (VQC) composed of a sequence of global rotations and entangling operations applied to a chain of qubits that are subject to dephasing noise. The parameters controlling the VQC are numerically optimized to maximize the quantum Fisher information, which characterizes the ultimate metrological sensitivity of a quantum state with respect to a global rotation. We find that, regardless of the details of the entangling operation implemented in the VQC, the optimal quantum states can be broadly classified into a trio of qualitative regimes, i.e., catlike, squeezed like, and product states, associated with different dephasing rates. Our findings are relevant for designing optimal state-preparation strategies for next-generation quantum sensors exploiting entanglement, such as time and frequency standards and magnetometers, aimed at achieving state-of-the-art performance in the presence of noise and decoherence.

quantum Fisher information↗

Ultralight dark matter detection with levitated ferromagnets

Levitated ferromagnets act as ultraprecise magnetometers, which can exhibit high quality factors due to their excellent isolation from the environment. These instruments can be utilized in searches for ultralight dark matter candidates, such as axionlike dark matter or dark-photon dark matter. In addition to being sensitive to an axion-photon coupling or kinetic mixing, which produce physical magnetic fields, ferromagnets are also sensitive to the effective magnetic field (or “axion wind”) produced by an axion-electron coupling. While the dynamics of a levitated ferromagnet in response to a dc magnetic field have been well studied, all of these couplings would produce ac fields. In this work, we study the response of a ferromagnet to an applied ac magnetic field and use these results to project their sensitivity to axion and dark-photon dark matter. We pay special attention to the direction of motion induced by an applied ac field, in particular, whether it precesses around the applied field (similar to an electron spin) or librates in the plane of the field (similar to a compass needle). We show that existing levitated ferromagnet setups can already have comparable sensitivity to an axion-electron coupling as comagnetometer or torsion balance experiments. In addition, future setups can become sensitive probes of axion-electron coupling, dark-photon kinetic mixing, and axion-photon coupling, for ultralight dark matter masses m DM ≲ feV . Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for ultralight dark matter in the SuperMAG high-fidelity dataset

Ultralight dark matter, such as kinetically mixed dark-photon dark matter (DPDM) or axion-like-particle dark matter (axion DM), can source an oscillating magnetic-field signal at Earth’s surface. Previous work searched for this signal in a publicly available dataset of global magnetometer measurements maintained by the SuperMAG collaboration. This “low-fidelity” dataset reported measurements with a 1-min time resolution, allowing the search to set leading direct constraints on DPDM and axion DM with Compton frequencies f DM ≤ 1 / ( 1 min ) (corresponding to masses m DM ≤ 7 × 10 − 17 eV ). More recently, a dedicated experiment undertaken by the SNIPE Hunt collaboration has also searched for this same signal at higher frequencies f DM ≥ 0.5 Hz (or m DM ≥ 2 × 10 − 15 eV ). In this work, we search for this signal of ultralight DM in the SuperMAG “high-fidelity” dataset, which features a 1-sec time resolution, allowing us to probe the gap in parameter space between the low-fidelity dataset and the SNIPE Hunt experiment. The high-fidelity dataset exhibits lower geomagnetic noise than the low-fidelity dataset and features more data than the SNIPE Hunt experiment, making it a powerful probe of ultralight DM. Our search finds no robust DPDM or axion DM candidates. We set constraints on DPDM and axion DM parameter space for 10 − 3 Hz ≤ f DM ≤ 0.98 Hz (or 4 × 10 − 18 eV ≤ m DM ≤ 4 × 10 − 15 eV ). Our results are the leading direct constraints on both DPDM and axion DM in this mass range, and our DPDM constraint surpasses the leading astrophysical constraint in a narrow range around m A ′ ≈ 2 × 10 − 15 eV . Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Rolling Root Mean Square Based Multimodal Anomaly Detection for Real Time Monitoring of Smart Grid

Reliable real-time monitoring is valuable for maintaining the operational integrity of modern electrical smart grids. Deployment of heterogeneous sensing technologies in substations has enabled high-resolution, multichannel waveform monitoring, but also introduces challenges for anomaly detection due to noise, baseline drift, and modality-dependent signal characteristics. In this work, we present a computationally efficient unsupervised method for multimodal event detection based on Rolling Root Mean Square based Event Detection (RRMSED). The method is developed using in-house, field deployed sensors collecting data at a utility substation. The sensing system comprises voltage and current sensors, triaxial accelerometers, and magnetometers, collectively capturing electrical, vibrational, and magnetic waveform measurements at high temporal resolution. RRMSED operates by extracting rolling RMS energy features and their first-order temporal differences from consecutive waveform segments for each channel and then applying channel-specific statistical thresholds learned from historical data. A persistence-based exceedance logic is employed to robustly identify transient events while suppressing impulsive noise, and to provide precise temporal localization with high resolution. The framework is designed for continuous server-side operation and can be deployed in real time without requiring complex models. Experiments on simulated waveform data with known ground truth demonstrate low false positive (FP) and false negative (FN) rates. Application to real substation data shows RRMSED to identify events that are not captured by conventional monitoring indicators including fast transient detection algorithm currently deployed in the system. These results indicate that rolling RMS based features provide an effective and practical basis for real-time multimodal event detection in smart-grid substations.

Mukherjee, Subrata [ORNL] (ORCID:0000000309930338)↗

Improving the performance of cryogenic calorimeters with nonlinear multivariate noise cancellation algorithms

Abstract State-of-the-art physics experiments require high-resolution, low-noise, and low-threshold detectors to achieve competitive scientific results. However, experimental environments invariably introduce sources of noise, such as electrical interference or microphonics. The sources of this environmental noise can often be monitored by adding specially designed “auxiliary devices” (e.g. microphones, accelerometers, seismometers, magnetometers, and antennae). A model can then be constructed to predict the detector noise based on the auxiliary device information, which can then be subtracted from the true detector signal. Here, we present a multivariate noise cancellation algorithm which can be used in a variety of settings to improve the performance of detectors using multiple auxiliary devices. To validate this approach, we apply it to simulated data to remove noise due to electromagnetic interference and microphonic vibrations. We then employ the algorithm to a cryogenic light detector in the laboratory and show an improvement in the detector performance. Finally, we motivate the use of nonlinear terms to better model vibrational contributions to the noise in thermal detectors. We show a further improvement in the performance of a particular channel of the CUORE detector when using the nonlinear algorithm in combination with optimal filtering techniques.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulation of the thermoelectric effect in a multi-metallic superconducting cavity

Superconducting radio-frequency accelerating cavities made with different material layers, such as copper, Nb or Nb₃Sn, are susceptible to thermoelectric effects due to differences in Seebeck coefficients between the metals. A temperature gradient across the surfaces can drive thermoelectric currents, which may impact the cavity performance. A layered Cu/Nb/Nb3Sn single-cell cavity was tested with cryocoolers in 2022. Three heaters were mounted on the cavity surface at different locations and three single-axis cryogenic fluxgate magnetometers were attached close to the cavity equator. A linear increase in the magnetic field was measured while increasing the heaters' power. The cavity setup was analyzed with COMSOL and the results showed a trend similar to that observed in the experiment. This contribution details the approach chosen for the simulation and some of the challenges encountered.

Accelerator Physics↗

Modeling of spin squeezing in OPMs and performance improvements

We propose to develop an optically pumped magnetometer (OPM) that implements spin squeezing to achieve better than standard quantum limit (SQL) performance while operating in mission relevant environments. This performance enhancement would allow us to increase the useable bandwidth by a factor > 2 while maintaining world class magnetic sensitivity, an order of magnitude better than commercially available options.

42 ENGINEERING↗

Development of magnetic field monitoring system for the MAGIS-100 experiment

The MAGIS-100 collaboration is building a long-baseline atom interferometer designed to investigate dark matter, novel forces, gravitational waves, and quantum science. A major design challenge is external, time-varying magnetic fields, the effect of which can mimic gravitational waves or expected dark matter signals. Several mitigations will be enacted, including mu-metal shielding and a suite of magnetometers. This presentation will discuss the development of a magnetic field monitoring system based on commercial magneto-inductive sensors to be installed at several points along the interferometer.

Arce, Edwin [Unlisted; Fermilab]↗

Mariner-Mars science subsystem

Mariner-Mars science subsystem - cosmic ray telescope, cosmic dust detector, trapped radiation detector, ionization chamber, plasma probe, magnetometer, and data processing

MARINER IV SPACE PROBE↗