Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

The Impact of Increased Requirements for Verification Measurements of Category III and IV Receipts

As part of the regular nuclear material accounting and control process, sites that have accountable nuclear material regularly perform measurements of the material in their possession. The expectation for the type of measurements and their frequency is set out in Department of Energy (DOE) Order 474.2, and further detailed in each site’s respective material control and accountability (MC&A) plan and associated controlling documents. The measurements of interest in this report are those performed on external (between DOE sites) transfer receipts of Category III or IV accountable materials. In 2020, a revision of DOE Order 474.2 was proposed that would significantly increase the requirement that measurements be performed upon receipt of material, and further, that those measurements be quantitative verification (rather than qualitative confirmatory) measurements. A survey was performed of DOE sites to discuss the impact on their MC&A measurements program if more rigorous verification measurements requirements for Category III and IV receipts were implemented. An assessment of nondestructive assay (NDA) measurement instruments to meet those needs was also performed. Across the board, sites indicated that personnel and budget would cause the largest impact. Sites which are qualified as Category I/II indicated a reduced impact as these sites already have the measurement capabilities and some personnel but would require the acquisition of additional measurement systems. Category III/IV sites indicated a much larger impact as these sites generally have smaller MC&A programs. A few smaller sites stated a measurement program would need to be created to handle the demand. Calorimetry, quantitative gamma spectroscopy and neutron coincidence counting systems were identified as common systems that could meet the verification measurement requirements. The other, and perhaps larger issue is the need for calibration standards for the calorimetry and neutron coincidence counting systems. It is proposed that a comparative study be performed for ISOCS and ISOTOPICS, qualification of a COTS calorimetry system be performed, and development of an AWCC system that uses a neutron generator.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Measuring Frequency Instability Of A Large Antenna

Frequency instability of antenna under test determined from measurement of phase deviation between outputs of two antennas. Fiber-optic system used to minimize spurious component of frequency instability contributed by propagation of signal from reference antenna to Allan-variance-measuring instrument. Intended primarily to reveal contributions of wind and air-temperature effects on antenna and beam-waveguide structures to overall frequency instabilities of received signals. Technique simpler, less expensive, potentially capable of providing instability data in shorter measuring times, and more precise.

Otoshi, Tom Y.↗

Coloration Determination of Spectral Darkening Occurring on a Broadband Earth Observing Radiometer: Application to Clouds and the Earth's Radiant Energy System (CERES)

It is estimated that in order to best detect real changes in the Earth s climate system, space based instrumentation measuring the Earth Radiation Budget (ERB) must remain calibrated with a stability of 0.3% per decade. Such stability is beyond the specified accuracy of existing ERB programs such as the Clouds and the Earth s Radiant Energy System (CERES, using three broadband radiometric scanning channels: the shortwave 0.3 - 5microns, total 0.3. > 100microns, and window 8 - 12microns). It has been shown that when in low earth orbit, optical response to blue/UV radiance can be reduced significantly due to UV hardened contaminants deposited on the surface of the optics. Since typical onboard calibration lamps do not emit sufficient energy in the blue/UV region, this darkening is not directly measurable using standard internal calibration techniques. This paper describes a study using a model of contaminant deposition and darkening, in conjunction with in-flight vicarious calibration techniques, to derive the spectral shape of darkening to which a broadband instrument is subjected. Ultimately the model uses the reflectivity of Deep Convective Clouds as a stability metric. The results of the model when applied to the CERES instruments on board the EOS Terra satellite are shown. Given comprehensive validation of the model, these results will allow the CERES spectral responses to be updated accordingly prior to any forthcoming data release in an attempt to reach the optimum stability target that the climate community requires.

Matthews, Grant↗

Longitudinally Jointed Edge-Wise Compression HoneyComb Composite Sandwich Coupon Testing And Fe Analysis: Three Methods of Strain Measurement, And Comparison

Three distinct strain measurement methods (i.e., foil resistance strain gages, fiber optic strain sensors, and a three-dimensional digital image photogrammetry that gives full field strain and displacement measurements) were implemented to measure strains on the back and front surfaces of a longitudinally jointed curved test article subjected to edge-wise compression testing, at NASA Goddard Space Flight Center, according to ASTM C364. The pre-test finite element analysis (FEA) was conducted to assess ultimate failure load and predict strain distribution pattern throughout the test coupon. The predicted strain pattern contours were then utilized as guidelines for installing the strain measurement instrumentations. The foil resistance strain gages and fiber optic strain sensors were bonded on the specimen at locations with nearly the same analytically predicted strain values, and as close as possible to each other, so that, comparisons between the measured strains by strain gages and fiber optic sensors, as well as the three-dimensional digital image photogrammetric system are relevant. The test article was loaded to failure (at ~167 kN), at the compressive strain value of ~10,000 micro epsilon. As a part of this study, the validity of the measured strains by fiber optic sensors is examined against the foil resistance strain gages and the three-dimensional digital image photogrammetric data, and comprehensive comparisons are made with FEA predictions.

Farrokh, Babak↗

Size resolved particle hygroscopcity for 30, 60, and 90 nm particles collected at the EPCAPE Mount Soledad site from 04/20/2023 to 06/15/2023

Contains both the growth factor probability density function (probability is out of 200) and the average growth factors calculated by the Gysel inversion. The instrument measured three different diameters 30 nm, 60nm and 90nm each diameter was selected for an hour. During that hour, five 12-minute scans were taken scanning growth factors from 0.5-3.0. RH was consistently kept at 85%. Calibrations of the instrument with NaCl were performed on 4/26/2023 from 11:20 to 14:20, on 5/16/2023 from 11:40 to 16:00, and on 5/30/2023 from 10:20 to 14:20. Calibrations with (NH4)2SO4 were performed on 5/8/2023 from 11:45 to 14:40, on 5/23/2023 from 11:20 to 3:00, and on 6/14/2023 from 13:00 to 16:00. Time is recorded in seconds since 1/1/1904.

30 nm particle hygroscopicity↗

Unmanned Instrument Platform for Undersea Exploration

Instruments accommodated on moving underwater platform. Towable underwater platform 3.2 meters long, 1.2 meters wide, 1.4 meters high and has mass of about 1,250 kilogram. Platform remotely operated and unmanned. Serves as test bed for development of ocean-measuring instruments and sonars at depths to 20,000 feet.

Paine, G.↗

Field spectroscopy of agricultural crops

The development of the full potential of multispectral data acquired from satellites, requires quantitative knowledge, and physical models of the spectral properties of specific earth surface features. Knowledge of the relationships between spectral-radiometric characteristics and important biophysical parameters of agricultural crops and soils can best be obtained by carefully controlled studies of fields or plots. It is important to select plots where data describing the agronomic-biophysical properties of the crop canopies and soil background are attainable, taking into account also the feasibility of frequent timely calibrated spectral measurements. The term 'field spectroscopy' is employed for this research. The present paper is concerned with field research which was sponsored by NASA as part of the AgRISTARS Supporting Research Project. Attention is given to field research objectives, field research instrumentation, measurement procedures, spectral-temporal profile modeling, and the effects of cultural and environmental factors on crop reflectance.

Bauer, M. E.↗

Single-Component Average Velocity Profiles in the Wake of the Orion Crew Capsule at the National Transonic Facility

A minimally intrusive molecular tagging instrument measured single-component average velocity profiles in two planes in the wake of the Orion capsule with different heat shield configurations in the National Transonic Facility at the NASA Langley Research Center. Reynolds number effects at subsonic conditions have proven difficult to predict due to the largely separated wake flow. Therefore two measurement planes in the wake of the model were probed to measure the wake profile for different heat shield configurations and act as a validation reference for computational tools. Air testing included Mach numbers of 0.3, 0.5, and 0.7 at Reynolds numbers of 5.3 and 7.5 million. In cryogenic nitrogen, the instrument was employed under transient conditions during the facility warm up at M = 0.3 with decreasing Reynolds numbers from 16 million. An exhaustive list of the results is shown and discussed here. For free transition heat shield configurations, the size of the wake was found to increase with Mach number, yet remain constant with Reynolds number for low (M = 0.3) and high (M = 0.7) subsonic Mach numbers. However, intermediate Mach numbers (M = 0.5) showed that the wake was smaller at higher Reynolds numbers for the IDAT heat shield. The addition of surface roughness in the form of grit, known as the fixed transition cases, negated any Mach number dependence to the wake profile and increased the size of the wake for all cases.

Velocimetry↗

Single-Component Average Velocity Profiles in the Wake of the Orion Crew Capsule at the National Transonic Facility

A minimally intrusive molecular tagging instrument measured single-component average velocity profiles in two planes in the wake of the Orion capsule with different heat shield configurations in the National Transonic Facility at the NASA Langley Research Center. Reynolds number effects at subsonic conditions have proven difficult to predict due to the largely separated wake flow. Therefore two measurement planes in the wake of the model were probed to measure the wake profile for different heat shield configurations and act as a validation reference for computational tools. Air testing included Mach numbers of 0.3, 0.5, and 0.7 at Reynolds numbers of 5.3 and 7.5 million. In cryogenic nitrogen, the instrument was employed under transient conditions during the facility warm up at M = 0.3 with decreasing Reynolds numbers from 16 million. An exhaustive list of the results is shown and discussed here. For free transition heat shield configurations, the size of the wake was found to increase with Mach number, yet remain constant with Reynolds number for low (M = 0.3) and high (M = 0.7) subsonic Mach numbers. However, intermediate Mach numbers (M = 0.5) showed that the wake was smaller at higher Reynolds numbers for the IDAT heat shield. The addition of surface roughness in the form of grit, known as the fixed transition cases, negated any Mach number dependence to the wake profile and increased the size of the wake for all cases.

Velocimetry↗

Time-domain sensitivity enhancement in pulsed Pb-TDL gas monitors

A Pb-salt tunable diode laser (TDL) has found many applications in the field of atmospheric gas analysis. Its continuous tunablility and fine spectral purity in the mid infrared region are outstanding from other lasers. The only shortcoming is that it requires cryogenic operating temperatures, though, it is improved year by year towards the room temperature operation. A repeated pulse operation of Pb salt diode lasers is possible with a thermoelectric cooling device, which allows an instrument a portable geometry disusing a heavy, bulky and power consuming mechanical refrigerator. A derivative spectrometry was exploiting the quick tunability of Pb salt diode lasers, though they are continuous wave (cw) operated with refrigerator or liquid nitrogen so far. A new system for derivative spectrometry with a pulsed diode laser will extend its field of applications because of reduced weights and size of measuring instruments. A preliminary results is shown that demonstrates the feasibility of an attempt to implement the derivative spectrmetry with repeatedly pulse driven diode lasers. Atmospheric methane was measured with 8 ppm/m sensitivity. Further results of parametric optimization for the best signal to noise ratios under any given device characteristics as well as for available real devices is given.

Koga, R.↗

Temperature prediction of space flight experiments by computer thermal analysis

Life sciences experiments are especially sensitive to temperature. A small temperature difference between otherwise identical samples can cause various differences in biological reaction rates. Knowledge of experimental temperatures and temperature histories help to distinguish the effects of microgravity and temperature on spaceflight experiments compared to ground based studies, and allow appropriate controls and sensitivity tests. Up to the present time, the Orbiter (Space Shuttle) has not generally provided temperature measurement instrumentation inside ambient lockers located in the Mid-deck of the Orbiter, or inside similar facilities such as Spacehab and Spacelab, but many pieces of hardware do have temperature recording capability. Most of these temperatures, however, have only been roughly measured or estimated. Such reported experimental temperatures, while accurate within a range of several degrees Celsius, are of limited utility to biological researchers. The temperature controlled lockers used in spaceflight, such as Commerical-Refrigeration Incubation Modules (C-R/IMs), severely reduce the mass and volume available for test samples and do not necessarily provide uniform thermal environments. While these test carriers avoid some of the experimental temperature variations of the ambient lockers, the number of samples which can be accommodated in these temperature controlled units is limited. In the present work, improved models of thermal prediction and control were sought. Temperatures are predicted by thermal analysis software using empirical temperatures recorded during STS-57. These temperatures are compared to data recorded throughout the mission using Ambient Temperature Recorders (ATRs) located within several payload lockers. Additional test cases are undertaken using controlled ground experiments to more precisely determine the reliability of the thermal model. The approach presented should increase the utility of various spaceflight carriers in the support of biological and material science research and ground control studies done in preparation for flight.

Birdsong, M. B.↗

The Challenge of Centennial Earthquakes to Improve Modern Earthquake Engineering

The recent commemoration of the centennial of the San Francisco and Valparaiso 1906 earthquakes has given the opportunity to reanalyze their damages from modern earthquake engineering perspective. These two earthquakes plus Messina Reggio Calabria 1908 had a strong impact in the birth and developing of earthquake engineering. The study of the seismic performance of some up today existing buildings, that survive centennial earthquakes, represent a challenge to better understand the limitations of our in use earthquake design methods. Only Valparaiso 1906 earthquake, of the three considered centennial earthquakes, has been repeated again as the Central Chile, 1985, Ms = 7.8 earthquake. In this paper a comparative study of the damage produced by 1906 and 1985 Valparaiso earthquakes is done in the neighborhood of Valparaiso harbor. In this study the only three centennial buildings of 3 stories that survived both earthquakes almost undamaged were identified. Since for 1985 earthquake accelerogram at El Almendral soil conditions as well as in rock were recoded, the vulnerability analysis of these building is done considering instrumental measurements of the demand. The study concludes that good performance of these buildings in the epicentral zone of large earthquakes can not be well explained by modern earthquake engineering methods. Therefore, it is recommended to use in the future of more suitable instrumental parameters, such as the destructiveness potential factor, to describe earthquake demand.

58 GEOSCIENCES↗

Apparatus for calibration of on-board instruments and laboratory modelling of rarefied plasma flows past models

Problems of laboratory simulation of artificial earth satellite flight conditions in the ionosphere are examined, and a setup capable of reproducing the basic parameters of ion flows (with energies of 5-10 eV, energy spectrum width approximately 2x5 eV, and an intensity of 10 to the minus 8th power a/cm/2) past measurement instruments and satellite models is described. Possibilities for further improvement of the apparatus are discussed.

Yevlanov, Y. N.↗

Investigations of the output energy deviation and other parameters during commissioning of the four-rod radio frequency quadrupole at the Fermi National Accelerator Laboratory

After 30 years of operation, the Cockcroft-Walton based injector at the Fermi National Accelerator Laboratory has been replaced by a new beam line including a dimpled magnetron 35 keV source in combination with a 750 keV four-rod radio frequency quadrupole (RFQ). The new injector is followed by the existing drift tube linac. Prior to installation, a test beam line was built which included the magnetron source and the four-rod RFQ with a number of beam measurement instrumentation. The first beam test with the RFQ showed an output energy deviation greater than 2.5%. Other problems also showed up which led to investigations of the output energy, power consumption and transmission properties using rf simulations which were complemented with additional beam measurements. The sources of this deviation and the mechanical modifications of the RFQ to solve this matter will be presented in this paper. Meanwhile, the nominal output energy of 750 keV has been confirmed and the new injector with the four-rod RFQ is in full operation.

43 PARTICLE ACCELERATORS↗

Inspection of commercial optical devices for data storage using a three Gaussian beam microscope interferometer

Recently, an interferometric profilometer based on the heterodyning of three Gaussian beams has been reported. This microscope interferometer, called a three Gaussian beam interferometer, has been used to profile high quality optical surfaces that exhibit constant reflectivity with high vertical resolution and lateral resolution near {lambda}. We report the use of this interferometer to measure the profiles of two commercially available optical surfaces for data storage, namely, the compact disk (CD-R) and the digital versatile disk (DVD-R). We include experimental results from a one-dimensional radial scan of these devices without data marks. The measurements are taken by placing the devices with the polycarbonate surface facing the probe beam of the interferometer. This microscope interferometer is unique when compared with other optical measuring instruments because it uses narrowband detection, filters out undesirable noisy signals, and because the amplitude of the output voltage signal is basically proportional to the local vertical height of the surface under test, thus detecting with high sensitivity. We show that the resulting profiles, measured with this interferometer across the polycarbonate layer, provide valuable information about the track profiles, making this interferometer a suitable tool for quality control of surface storage devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Midlatitude Continental Convective Clouds Experiment (MC3E)

Convective processes play a critical role in the Earth’s energy balance through the redistribution of heat and moisture in the atmosphere and subsequent impacts on the hydrologic cycle. Global observation and accurate representation of these processes in numerical models is vital to improving our current understanding and future simulations of Earth’s climate system. Despite improvements in computing power, current operational weather and global climate models are unable to resolve the natural temporal and spatial scales that are associated with convective and stratiform precipitation processes; therefore, they must turn to parameterization schemes to represent these processes. In turn, the physical basis for these parameterization schemes needs to be evaluated for general application under a variety of atmospheric conditions. Analogously, space-based remote sensing algorithms designed to retrieve related cloud and precipitation information for use in hydrological, climate, and numerical weather prediction applications often rely on physical “parameterizations” that reliably translate indirectly related instrument measurements to the physical quantity of interest (e.g., precipitation rate). Importantly, both spaceborne retrieval algorithms and model convective parameterization schemes traditionally rely on field campaign data sets as a basis for evaluating and improving the physics of their respective approaches. The Midlatitude Continental Convective Clouds Experiment (MC3E) will take place in central Oklahoma during the April–May 2011 period. The experiment is a collaborative effort between the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility and the National Aeronautics and Space Administration’s (NASA) Global Precipitation Measurement (GPM) mission Ground Validation (GV) program. The field campaign leverages the unprecedented observing infrastructure currently available in the central United States, combined with an extensive sounding array, remote sensing and in situ aircraft observations, NASA GPM ground validation remote sensors, and new ARM instrumentation purchased with American Recovery and Reinvestment Act funding. The overarching goal is to provide the most complete characterization of convective cloud systems, precipitation, and the environment that has ever been obtained, providing constraints for model cumulus parameterizations and space-based rainfall retrieval algorithms over land that have never before been available. Several different components of convective cloud and precipitation processes tangible to both the convective parameterization and precipitation retrieval algorithm problem are targeted, such as preconvective environment and convective initiation, updraft/downdraft dynamics, condensate transport and detrainment, precipitation and cloud microphysics, spatial and temporal variability of precipitation, influence on the environment and radiation, and a detailed description of the large-scale forcing.

54 ENVIRONMENTAL SCIENCES↗

Cosmoids - Solution to the Pioneer 10 and 11 meteoroid measurement enigma

Experimental results from the three dust experiments on the Pioneer 11 and 12 spacecraft are used here to define the distribution and structural characteristics of what is believed to be the dominant population of meteoroids in the inner solar system. No two experiments agreed on the dust distribution and only the Imaging Photopolarimeter experiment could be fitted to the prevailing model of dust spiraling inward from the asteroid belt. Meteoroid Detection Experiment data showed a nearly constant flux from 1 to 18 AU. Reexamination of Asteoroid/Meteoroid Experiment or 'Sisyphus' data shows that the instrument measured a population of long-period meteoroids called cosmoids, composed mainly of water which dominates the dust distribution. Once the prevailing short period dust model is discounted, the results from the three instruments are shown to agree.

Dubin, Maurice↗

Results from Solar Reflective Band End-to-End Testing for VIIRS F1 Sensor Using T-SIRCUS

Verification of the Visible Infrared Imager Radiometer Suite (VIIRS) End-to-End (E2E) sensor calibration is highly recommended before launch, to identify any anomalies and to improve our understanding of the sensor on-orbit calibration performance. E2E testing of the Reflective Solar Bands (RSB) calibration cycle was performed pre-launch for the VIIRS Fight 1 (F1) sensor at the Ball Aerospace facility in Boulder CO in March 2010. VIIRS reflective band calibration cycle is very similar to heritage sensor MODIS in that solar illumination, via a diffuser, is used to correct for temporal variations in the instrument responsivity. Monochromatic light from the NIST T-SIRCUS was used to illuminate both the Earth View (EV), via an integrating sphere, and the Solar Diffuser (SD) view, through a collimator. The collimator illumination was cycled through a series of angles intended to simulate the range of possible angles for which solar radiation will be incident on the solar attenuation screen on-orbit. Ideally, the measured instrument responsivity (defined here as the ratio of the detector response to the at-sensor radiance) should be the same whether the EV or SD view is illuminated. The ratio of the measured responsivities was determined at each collimator angle and wavelength. In addition, the Solar Diffuser Stability Monitor (SDSM), a ratioing radiometer designed to track the temporal variation in the SD BRF by direct comparison to solar radiation, was illuminated by the collimator. The measured SDSM ratio was compared to the predicted ratio. An uncertainty analysis was also performed on both the SD and SDSM calibrations.

McIntire, Jeff↗