Search NASA⌕ Search

SEARCH · Search NASA

Results for “Monte Carlo code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Validation of Numerical Tools for Calculating Reactivity Feedback in Sodium Fast Reactors Using SEFOR Experimental Data

The Southwest Experimental Fast Oxide Reactor (SEFOR) was an experimental sodium-cooled fast breeder reactor operated from 1969 to 1972 with experiments designed to measure Doppler reactivity feedback in a wide temperature range from around 350 °F to temperatures approaching the melting point of mixed oxide fuel of around 5000 °F, providing valuable data for code validations. Co-supported by the Department of Energy (DOE) Fast Reactor Program (FRP) and the DOE Nuclear Energy Advanced Modeling and Simulation (NEAMS) program, the SEFOR benchmark project focused on using the experimental data to validate numerical tools that are used in industry and academia to design and license sodium-cooled fast reactors (SFRs). By the end of FY-25, substantial progress was achieved in the SEFOR benchmark study. A variety of numerical tools commonly used for modeling SFRs were applied to develop models for SEFOR core configurations I-D, I-E, I-I, and I-J. These included Monte Carlo codes such as MCNP, Serpent, and Shift; deterministic codes such as the legacy Argonne Reactor Computation (ARC) suite and the high-fidelity NEAMS code Griffin; and the system analysis code SAS4A/SASSYS-1 (SAS). Using these models, both SEFOR zero-power experiments and power-ascending tests were successfully simulated. Comparisons were performed against experimental measurements of core criticalities, reflector worth, kinetics parameters (Λ/βeff), isothermal reactivity feedback (from 350 °F to 760 °F at zero power), and power-ascending reactivity feedback (as power increased from 0.4 MW to 17 MW). In general, these comparisons demonstrated very good agreement between numerical results and experimental data. In Fiscal Year 26 (FY-26), the SEFOR benchmark project will continue to address the modeling issues identified in FY-25. Effort will focus on the simulation of reactivity insertion transients in SEFOR core II using the ARC/SAS model. Future work will also focus on incorporating BISON into the SEFOR core modeling process to enable the first Multiphysics simulations of the isothermal tests based on the MOOSE framework.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-E-J-138: On the Ion Beam Range and Dose Verification in Hadron Therapy Using Sound Waves

Purpose: Accurate range verification is of great importance to fully exploit the potential benefits of ion beam therapies. Current research efforts on this topic include the use of PET imaging of induced activity, detection of emerging prompt gamma rays or secondary particles. It has also been suggested recently to detect the ultrasound waves emitted through the ion energy absorption process. The energy absorbed in a medium is dissipated as heat, followed by thermal expansion that leads to generation of acoustic waves. By using an array of ultrasound transducers the precise spatial location of the Bragg peak can be obtained. The shape and intensity of the emitted ultrasound pulse depend on several variables including the absorbed energy and the pulse length. The main objective of this work is to understand how the ultrasound wave amplitude and shape depend on the initial ion energy and intensity. This would help guide future experiments in ionoacoustic imaging. Methods: The absorbed energy density for protons and carbon ions of different energy and field sizes were obtained using Fluka Monte Carlo code. Subsequently, the system of coupled equations for temperature and pressure is solved for different ion pulse intensities and lengths to obtain the pressure wave shape, amplitude and spectral distribution. Results: The proposed calculations show that the excited pressure wave amplitude is proportional to the absorbed energy density and for longer ion pulses inversely proportional to the ion pulse duration. It is also shown that the resulting ionoacoustic pressure distribution depends on both ion pulse duration and time between the pulses. Conclusion: The Bragg peak localization using ionoacoustic signal may eventually lead to the development of an alternative imaging method with sub-millimeter resolution. It may also open a way for in-vivo dose verification from the measured acoustic signal.

60 APPLIED LIFE SCIENCES↗

Energy loss of argon in a laser-generated carbon plasma

The experimental data presented in this paper address the energy loss determination for argon at 4 MeV/u projectile energy in laser-generated carbon plasma covering a huge parameter range in density and temperature. Furthermore, a consistent theoretical description of the projectile charge state evolution via a Monte Carlo code is combined with an improved version of the CasP code that allows us to calculate the contributions to the stopping power of bound and free electrons for each projectile charge state. This approach gets rid of any effective charge description of the stopping power. Comparison of experimental data and theoretical results allows us to judge the influence of different plasma parameters.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-F-T-217: A Comprehensive Monte-Carlo Study of Out-Of-Field Secondary Neutron Spectra in a Scanned-Beam Proton Therapy Treatment Room

Purpose: To simulate secondary neutron radiation-fields produced at different positions during phantom irradiation inside a scanning proton therapy gantry treatment room. Further, to identify origin, energy distribution and angular emission as function of proton beam energy. Methods: GEANT4 and FLUKA Monte-Carlo codes were used to model the relevant parts of the treatment room in a gantry-equipped pencil beam scanning proton therapy facility including walls, floor, metallic gantry-components, patient table and the homogeneous PMMA target. The proton beams were modeled based on experimental beam ranges in water and spot shapes in air. Neutron energy spectra were simulated at 0°, 45°, 90° and 135° relative to the beam axis at 2m distance from isocenter, as well as 11×11 cm2 fields for 75MeV, 140MeV, 200MeV and for 118MeV with 5cm PMMA range-shifter. The total neutron energy distribution was recorded for these four positions and proton energies. Additionally, the room-components generating secondary neutrons in the room and their contributions to the total spectrum were identified and quantified. Results: FLUKA and GEANT4 simulated neutron spectra showed good general agreement in the whole energy range of 10{sup −}9 to 10{sup 2} MeV. Comparison of measured spectra with the simulated contributions of the various room components helped to limit the complexity of the room model, by identifying the dominant contributions to the secondary neutron spectrum. The iron of the bending magnet and counterweight were identified as sources of secondary evaporation-neutrons, which were lacking in simplified room models. Conclusion: Thorough Monte-Carlo simulations have been performed to complement Bonner-sphere spectrometry measurements of secondary neutrons in a clinical proton therapy treatment room. Such calculations helped disentangling the origin of secondary neutrons and their dominant contributions to measured spectra, besides providing a useful validation of widely used Monte-Carlo packages in comparison to experimental data. Cluster of Excellence of the German Research Foundation (DFG) “Munich-Centre for Advanced Photonics (MAP)”.

60 APPLIED LIFE SCIENCES↗

THE DISTRIBUTION AND ANNIHILATION OF DARK MATTER AROUND BLACK HOLES

We use a Monte Carlo code to calculate the geodesic orbits of test particles around Kerr black holes, generating a distribution function of both bound and unbound populations of dark matter (DM) particles. From this distribution function, we calculate annihilation rates and observable gamma-ray spectra for a few simple DM models. The features of these spectra are sensitive to the black hole spin, observer inclination, and detailed properties of the DM annihilation cross-section and density profile. Confirming earlier analytic work, we find that for rapidly spinning black holes, the collisional Penrose process can reach efficiencies exceeding 600%, leading to a high-energy tail in the annihilation spectrum. The high particle density and large proper volume of the region immediately surrounding the horizon ensures that the observed flux from these extreme events is non-negligible.

79 ASTRONOMY AND ASTROPHYSICS↗

Simulation of dose distribution for iridium-192 brachytherapy source type-H01 using MCNPX

Dosimetric data for a brachytherapy source should be known before it used for clinical treatment. Iridium-192 source type H01 was manufactured by PRR-BATAN aimed to brachytherapy is not yet known its dosimetric data. Radial dose function and anisotropic dose distribution are some primary keys in brachytherapy source. Dose distribution for Iridium-192 source type H01 was obtained from the dose calculation formalism recommended in the AAPM TG-43U1 report using MCNPX 2.6.0 Monte Carlo simulation code. To know the effect of cavity on Iridium-192 type H01 caused by manufacturing process, also calculated on Iridium-192 type H01 if without cavity. The result of calculation of radial dose function and anisotropic dose distribution for Iridium-192 source type H01 were compared with another model of Iridium-192 source.

61 RADIATION PROTECTION AND DOSIMETRY↗

A benchmarking study of Geant4 for Auger electrons emitted by medical radioisotopes

Auger emitting radioisotopes are of great interest in targeted radiotherapy because, once internalised in the tumour cells, they can deliver dose locally to the radiation sensitive targets, while not affecting surrounding cells. Geant4 is a Monte Carlo code widely used to characterise the physics mechanism at the basis of targeted radiotherapy. Here, we benchmarked the modelling of the emission of Auger electrons in Geant4 deriving from the decay of 123 I, 124 I, 125 I radionuclides against existing theoretical approaches. We also compared Geant4 against reference data in the case of 131 Cs, which is of interest for brachytherapy. In the case of 125 I and 131 Cs, the simulation results are compared to experimental measurements as well. Good agreement was found between Geant4 and the reference data. As far as we know, this is the first study aimed to benchmark against experimental measurements the emission of Auger electrons in Geant4 for radiotherapy applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-T-30: A Factor for Converting Dose to a Gold Nanoparticle Mixture to a Biologically-Relevant Dose

Purpose: Monte Carlo studies of gold nanoparticle (GNP) dose enhancement on macroscopic scales in radiotherapy have modeled GNPs in tissue as a homogeneous mixture of gold and tissue. Using an explicit model of GNPs randomly positioned in a small volume (1 µm{sup 3}) of tissue, this study aims to quantify the dose to the biologically relevant component of a goldtissue mixture, enabling a conversion from macroscopically-scored dose. Methods: Using the PENELOPE Monte Carlo code with the penEasy package, we modeled a 1 µm{sup 3} volume containing either a tissue-gold mixture or GNPs suspended in ICRU 4-component tissue at various gold concentrations (0, 5, 10, and 15 mg Au/g tissue) and GNP diameters (20, 30, 40, 50 nm). The volume was irradiated with monoenergetic photon and electron beams, ranging from 110 eV to 6 MeV. Interaction forcing was utilized to increase simulation efficiency. Energy deposition was scored in the tissue for each case and was converted to dose. For each scenario, we calculated a conversion factor, the ratio of dose-to-tissue to dose-to-mixture as a function of energy. Results: The conversion factor was plotted as a function of energy for both photons and electrons. For electrons, the conversion factor was relatively unaffected by any of the parameters, including energy, ranging between 0.98–1.02. For photons, the factor was very energy dependent, with a range of 0.49–1.02. The factor was lowest for 10–100 keV photons. The conversion factor generally decreased with increasing GNP concentration and increasing GNP size. Conclusion: With a large variation in the conversion factor with incident energy, dose deposition is dependent on the spectrum incident on a volume. By scoring the energy spectrum in a given volume, one can provide a scenario-specific conversion factor, allowing fast, detailed Monte Carlo simulations without the need for explicit GNP-definition.

60 APPLIED LIFE SCIENCES↗

Transient Multiphysics Simulations with Pin Power Reconstruction in the Griffin Reactor Physics Code

This work introduces the pin power reconstruction capability available in the Griffin reactor physics code. This capability is implemented in an unstructured mesh framework, and the methods introduced are applied to the 2D SIMBA reactor core, which has assemblies and pins arranged in a hexagonal lattice. Since this reactor has a non-Cartesian geometry and also operates in the thermal spectrum, a general approach to pin power reconstruction is adopted, where SPH-based equivalence is leveraged to preserve assembly-wise reaction rates, while computing full-core form functions to preserve pin-wise fission production rates within the fuel pins of the reactor core. In a 2D microreactor benchmark problem, this pin power reconstruction approach was shown to reproduce pin powers compared to the Serpent2 Monte Carlo code for fixed temperature conditions and control drum rotation angles, yielding a core-wide RMS error level of 0.6\% and a maximum absolute pin error of 2.3\%. In addition, a tabulated library of multigroup cross sections, SPH factors, and form functions was generated to demonstrate the applicability of pin power reconstruction to a thermal feedback problem. Finally, a control drum transient was successfully simulated, showcasing the application of pin power reconstruction in a transient multiphysics feedback problem.

97 - MATHEMATICS AND COMPUTING↗

The interaction of quasi-monoenergetic protons with pre-compressed inertial fusion fuels

The interaction of a quasi-monoenergetic proton beam with a pre-compressed plasma is studied in the context of inertial fusion fast ignition (FI). Based on fundamental principles, a kinetic model is developed by considering hard collisions, nuclear scattering, and the contribution due to collective processes. The penetration depth, longitudinal straggling, and the transverse blooming are evaluated by solving the Boltzmann transport equation using the multiple scattering theory. The stopping power, transport scattering cross sections, and convenient expressions for the angular moments of the proton distribution function have been used in modeling the collisional proton transport in a three-dimensional (3D) Monte Carlo code. The transport of a proton beam with a quasi-monoenergetic energy =10 MeV is studied for pre-compressed deuterium-tritium plasma with an average density of {rho}=400 g cm{sup -3} and temperatures T=1 keV, 5 keV, and 10 keV. The net effects of multiple scattering are to reduce the penetration from 1.028 to 0.828 g cm{sup -2} with range straggling {rho}{Sigma}{sub R}=0.044 g cm{sup -2} and beam blooming {rho}{Sigma}{sub B}=0.272 g cm{sup -2}, for 10 MeV protons in a {rho}=400 g cm{sup -3} plasma at T = 5 keV. This model can be used for quantitatively assessing ignition requirements for proton fast ignition.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-T-523: On the Radiobiological Impact of Lateral Scatter in Proton Beams

Introduction: In proton therapy, justified concern has been voiced with respect to an increased efficiency in cell kill at the distal end of the Bragg peak. This coupled with range uncertainty is a counter indication to use the Bragg peak to define the border of a treated volume with a critical organ. An alternative is to use the lateral edge of the proton beam, obtaining more robust plans. We investigate the spectral and biological effects of the lateral scatter . Methods: A general purpose Monte Carlo simulation engine (MCNPX 2.7c) installed on a Scientific Linux cluster, calculated the dose deposition spectrum of protons, knock on electrons and generated neutrons for a proton beam with maximal kinetic energy of 200MeV. Around the beam at different positions in the beam direction the spectrum is calculated in concentric rings of thickness 1cm. The deposited dose is converted to a double strand break map using an analytical expression.based on micro dosimetric calculations using a phenomenological Monte Carlo code (MCDS). A strict version of RBE is defined as the ratio of generation of double strand breaks in the different modalities. To generate the reference a Varian linac was modelled in MCNPX and the generated electron dose deposition spectrum was used . Results: On a pristine point source 200MeV beam the RBE before the Bragg peak was of the order of 1.1, increasing to 1.7 right behind the Bragg peak. When using a physically more realistic beam of 10cm diameter the effect was smaller. Both the lateral dose and RBE increased with increasing beam depth, generating a dose deposition with mixed biological effect. Conclusions: The dose deposition in proton beams need to be carefully examined because the biological effect will be different depending on the treatment geometry. Deeply penetrating proton beams generate more biologically effective lateral scatter.

07 ISOTOPE AND RADIATION SOURCES↗

On-the-fly Doppler Broadening with Probability Table Interpolation for Unresolved Resonance Region in RMC

With the rapid development of computational power and parallel algorithms, Monte Carlo method has been widely investigated and used in neutron transport simulations due to its advantages in geometry modelling and usage of continuous energy point-wise cross sections. Nowadays the road has been paved to couple Monte Carlo codes with thermal-hydraulics codes to make multi-physics calculations. One of the most important aspects of thermal-hydraulics feedback is the detailed temperature distribution, which demands temperature dependent cross sections in neutron transport simulations. The conventional pre-generated cross section libraries at each temperature point are no longer feasible for detailed temperature distributions because of tremendous memory footprint. Hence, different on-the-fly Doppler broadening methods have been proposed for resolved resonance energy region and thermal energy region, such as the interpolation, regress model fitting, multipole representation (MPR), target motion sampling (TMS) and different integration algorithms based on Doppler broadening equation. Compared to resolved resonance energy region and thermal energy region, the representation of cross sections in unresolved resonance region is slightly different. As a result of the limitation of experiment measurements, the overlapped resonances cannot be distinguished from each other and the statistic average resonance parameters are given in the evaluated nuclear data file. In early applications, infinite-dilute pointwise cross sections were obtained from average parameters and were directly used in neutron simulations. However, it was proven that these infinite-dilute pointwise cross sections cannot capture the energy self-shielding effect, thus leading to an overestimate of reaction rates and usually an underestimate of k{sub eff} owing to the increased absorption rates and increased scattering probability to energy below unresolved resonance region where the capture-to-fission ratio is typically higher. This phenomenon is of great importance especially for problems where there is a considerable flux in unresolved resonance region. Then the probability table method was put forward by Levitt to take energy self-shielding effect into account, which provides probability distribution function of cross sections in unresolved resonance region instead of specific cross section values. The probability distribution function is presented in the form of tables and the mean values are equal to the infinite dilution cross sections. To obtain the temperature dependent cross sections in unresolved energy region, there are two different methods. One is to calculate cross sections directly from average resonance parameters and their statistical distributions , which is effective and precise but time-consuming. The other is to interpolate between pre-generated probability table files, which is much more efficient. In this paper, on-the-fly Doppler broadening of cross sections in unresolved resonance regions based on probability tables interpolation was implemented in RMC codes as a supplement to on-the-fly Doppler broadening for resolved resonance energy region and thermal region, which is based on the integration of Doppler broadening equation. The results of criticality calculation and depletion calculation show that on-the-fly Doppler broadening for the whole energy region is accurate and efficient. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Stochastic-field cavitation model

Nonlinear phenomena can often be well described using probability density functions (pdf) and pdf transport models. Traditionally, the simulation of pdf transport requires Monte-Carlo codes based on Lagrangian “particles” or prescribed pdf assumptions including binning techniques. Recently, in the field of combustion, a novel formulation called the stochastic-field method solving pdf transport based on Eulerian fields has been proposed which eliminates the necessity to mix Eulerian and Lagrangian techniques or prescribed pdf assumptions. In the present work, for the first time the stochastic-field method is applied to multi-phase flow and, in particular, to cavitating flow. To validate the proposed stochastic-field cavitation model, two applications are considered. First, sheet cavitation is simulated in a Venturi-type nozzle. The second application is an innovative fluidic diode which exhibits coolant flashing. Agreement with experimental results is obtained for both applications with a fixed set of model constants. The stochastic-field cavitation model captures the wide range of pdf shapes present at different locations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Influence of photon energy spectra from brachytherapy sources on Monte Carlo simulations of kerma and dose rates in water and air

Purpose: For a given radionuclide, there are several photon spectrum choices available to dosimetry investigators for simulating the radiation emissions from brachytherapy sources. This study examines the dosimetric influence of selecting the spectra for {sup 192}Ir, {sup 125}I, and {sup 103}Pd on the final estimations of kerma and dose. Methods: For {sup 192}Ir, {sup 125}I, and {sup 103}Pd, the authors considered from two to five published spectra. Spherical sources approximating common brachytherapy sources were assessed. Kerma and dose results from GEANT4, MCNP5, and PENELOPE-2008 were compared for water and air. The dosimetric influence of {sup 192}Ir, {sup 125}I, and {sup 103}Pd spectral choice was determined. Results: For the spectra considered, there were no statistically significant differences between kerma or dose results based on Monte Carlo code choice when using the same spectrum. Water-kerma differences of about 2%, 2%, and 0.7% were observed due to spectrum choice for {sup 192}Ir, {sup 125}I, and {sup 103}Pd, respectively (independent of radial distance), when accounting for photon yield per Bq. Similar differences were observed for air-kerma rate. However, their ratio (as used in the dose-rate constant) did not significantly change when the various photon spectra were selected because the differences compensated each other when dividing dose rate by air-kerma strength. Conclusions: Given the standardization of radionuclide data available from the National Nuclear Data Center (NNDC) and the rigorous infrastructure for performing and maintaining the data set evaluations, NNDC spectra are suggested for brachytherapy simulations in medical physics applications.

61 RADIATION PROTECTION AND DOSIMETRY↗

Monte Carlo simulation of a Bonner sphere spectrometer for application to the determination of neutron field in the Experimental Advanced Superconducting Tokamak experimental hall

To assess the neutron energy spectra and the neutron dose for different positions around the Experimental Advanced Superconducting Tokamak (EAST) device, a Bonner Sphere Spectrometer (BSS) was developed at Peking University, with totally nine polyethylene spheres and a SP9 {sup 3}He counter. The response functions of the BSS were calculated by the Monte Carlo codes MCNP and GEANT4 with dedicated models, and good agreement was found between these two codes. A feasibility study was carried out with a simulated neutron energy spectrum around EAST, and the simulated “experimental” result of each sphere was obtained by calculating the response with MCNP, which used the simulated neutron energy spectrum as the input spectrum. With the deconvolution of the “experimental” measurement, the neutron energy spectrum was retrieved and compared with the preset one. Good consistence was found which offers confidence for the application of the BSS system for dose and spectrum measurements around a fusion device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of hafnium configuration of FLUOLE-2 program - 25409

The purpose of this paper is to present an analysis of the hafnium configuration of FLUOLE-2 program. FLUOLE-2 is a set of benchmark-type experiments dedicated to neutron attenuation analysis with the aim of improving the TRIPOLI-4{sup R} Monte Carlo code validation and industrial neutron physics scheme. The CEA developed this program, with the support of EDF, in order to be representative of 900 and 1450 MWe Pressurized Water Reactors operated in France. For that purpose, different stainless steel structures have been designed and appropriately positioned inside the EOLE facility located at Cadarache CEA center. EOLE is a pool type zero power reactor, composed of a cylindrical aluminum vessel with an over-structure of stainless steel, that is able to contain various types of core and related structures. The FLUOLE-2 core has been designed as a 29 x 29 pins square lattice of fuel rods. Different kind of dosimeters (cobalt, gold, tin, rhodium, indium, iron, nickel, titanium, aluminum, and vanadium) were irradiated inside and outside the core. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-C-BRC-05: Monte Carlo Calculations to Establish a Simple Relation of Backscatter Dose Enhancement Around High-Z Dental Alloy to Its Atomic Number

Purpose: To establish a simple relation of backscatter dose enhancement around a high-Z dental alloy in head and neck radiation therapy to its average atomic number based on Monte Carlo calculations. Methods: The PHITS Monte Carlo code was used to calculate dose enhancement, which is quantified by the backscatter dose factor (BSDF). The accuracy of the beam modeling with PHITS was verified by comparing with basic measured data namely PDDs and dose profiles. In the simulation, a high-Z alloy of 1 cm cube was embedded into a tough water phantom irradiated by a 6-MV (nominal) X-ray beam of 10 cm × 10 cm field size of Novalis TX (Brainlab). The ten different materials of high-Z alloys (Al, Ti, Cu, Ag, Au-Pd-Ag, I, Ba, W, Au, Pb) were considered. The accuracy of calculated BSDF was verified by comparing with measured data by Gafchromic EBT3 films placed at from 0 to 10 mm away from a high-Z alloy (Au-Pd-Ag). We derived an approximate equation to determine the relation of BSDF and range of backscatter to average atomic number of high-Z alloy. Results: The calculated BSDF showed excellent agreement with measured one by Gafchromic EBT3 films at from 0 to 10 mm away from the high-Z alloy. We found the simple linear relation of BSDF and range of backscatter to average atomic number of dental alloys. The latter relation was proven by the fact that energy spectrum of backscatter electrons strongly depend on average atomic number. Conclusion: We found a simple relation of backscatter dose enhancement around high-Z alloys to its average atomic number based on Monte Carlo calculations. This work provides a simple and useful method to estimate backscatter dose enhancement from dental alloys and corresponding optimal thickness of dental spacer to prevent mucositis effectively.

60 APPLIED LIFE SCIENCES↗

GENERATION OF HIGH-ENERGY PHOTONS AT ULTRA-RELATIVISTIC SHOCK BREAKOUT IN SUPERNOVAE

We present theoretical expectations for non-thermal emission due to the bulk Comptonization at the ultra-relativistic shock breakout. We calculate the transfer of photons emitted from the shocked matter with a Monte Carlo code fully taking into account special relativity. As a hydrodynamical model, we use the self-similar solution of Nakayama and Shigeyama. Our calculations reveal that the spectral shape exhibits a double peak or a single peak depending on the shock temperature at breakout; if it is significantly smaller than the rest energy of an electron, the spectrum has a double peak. We also include a few sample light curves, and estimate the total radiation energy. In comparison with observations of γ-ray bursts, a part of the higher energy component in the spectra and the total energy can be reproduced by some parameter sets. Meanwhile, the lower energy counterpart in the Band function is not reproduced by our results and the duration seems too short to represent an entire γ-ray burst. Therefore the subsequent phase will constitute the lower energy part of the spectrum.

79 ASTRONOMY AND ASTROPHYSICS↗