Search NASA⌕ Search

SEARCH · Search NASA

Results for “ORIFICES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

System and method for small, clean, steady-state fusion reactors

According to some embodiments, a system for widening and densifying a scrape-off layer (SOL) in a field reversed configuration (FRC) fusion reactor is disclosed. The system includes a gas box at one end of the reactor including a gas inlet system and walls of suitable heat bearing materials. The system further includes an exit orifice adjoining the gas box, wherein the exit orifice has a controllable radius and length to allow plasma to flow out from the gas box to populate the SOL with the plasma. The system may also include fusion products, which decrease in speed in the plasma in the SOL, allowing energy to be extracted and converted into thrust or electrical power and further allowing ash to be extracted to reduce neutron emissions and maintain high, steady-state fusion power.

Cohen, Samuel A.↗

Aerosol Formation from High-Pressure Sprays for Supporting the Safety Analysis for the Hanford Waste Treatment and Immobilization Plant - 13183

The Waste Treatment and Immobilization Plant (WTP) at Hanford is being designed and built to pretreat and vitrify waste currently stored in underground tanks at Hanford. One of the postulated events in the hazard analysis for the WTP is a breach in process piping that produces a pressurized spray with small droplets that can be transported into ventilation systems. Literature correlations are currently used for estimating the generation rate and size distribution of aerosol droplets in postulated releases. These correlations, however, are based on results obtained from small engineered nozzles using Newtonian liquids that do not contain slurry particles and thus do not represent the fluids and breaches in the WTP. A test program was developed to measure the generation rate, and the release fraction which is the ratio of generation rate to spray flow rate, of droplets suspended in a test chamber and droplet size distribution from prototypic sprays. A novel test method was developed to allow measurement of sprays from small to large breaches and also includes the effect of aerosol generation from splatter when the spray impacts on walls. Results show that the release fraction decreases with increasing orifice area, though with a weaker dependence on orifice area than the currently-used correlation. A comparison of water sprays to slurry sprays with 8 to 20 wt% gibbsite or boehmite particles shows that the presence of slurry particles depresses the release fraction compared to water for droplets above 10 μm and increases the release fraction below this droplet size. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Environmental control and air distribution system and method of using the same

An indoor environmental control and air distribution system for a building includes: an air handling unit; a manifold connected to the air handling unit having a chamber formed by a plurality of walls and a plurality of orifices formed through at least one of the walls; air distribution conduits each independently having a first end connected to the orifices of the manifold and a second end extending out from the manifold into different zones throughout the building; and an airflow modulating device having one or more airflow regulating dampers independently configured to move into at least two positions in which each position provides a different percentage of total air volume to each air distribution conduit. A method of using the indoor environmental control and air distribution system is also included.

Poerschke, Andrew↗

Open aperture flow cells for on-line optical analysis of process fluids

A flow cell system includes a vessel and a fluid located in the vessel. A fluid surface of the fluid can be vented to a first gas pressure. The fluid surface can have a first cross-sectional area. The flow cell system includes a conduit in fluid communication with the vessel and positioned downstream of the vessel. The conduit can have a region that includes one or more orifices and has a second cross-sectional area. The second cross-sectional area can be less than the first cross-sectional area. The one or more orifices can be vented to a second gas pressure. The second gas pressure can be equal to or greater than the first gas pressure. Methods for analyzing a process fluid can include characterizing the fluid in the conduit.

Launiere, Cari A.↗

Percutaneous Mitral Valve Dilatation: Single Balloon versus Double Balloon - A Finite Element Study

Background: Percutaneous mitral valve (MV) dilatation is performed with either a single balloon (SB) or double balloon (DB) technique. The aim of this study was to compare the two balloon system results using the finite element (FE) method. Methods and Results: An established FE model of the MV was modified by fusing the MV leaflet edges at commissure level to simulate a stenotic valve (orifice area=180mm2). A FE model of a 30mm SB (low-pressure, elastomeric balloon) and an 18mm DB system (high-pressure, non-elastic balloon) was created. Both SB and DB simulations resulted in splitting of the commissures and subsequent stenosis dilatation (final MV area=610mm2 and 560mm2 respectively). Stresses induced by the two balloon systems varied across the valve. At the end of inflation, SB showed higher stresses in the central part of the leaflets and at the commissures compared to DB simulation, which demonstrated a more uniform stress distribution. The higher stresses in the SB analysis were due to the mismatch of the round balloon shape with the oval mitral orifice. The commissural split was not easily accomplished with the SB due to its high compliance. The high pressure applied to the DB guaranteed the commissural split even when high forces were required to break the commissure welds. Conclusions: The FE model demonstrated that MV dilatation can be accomplished by both SB and DB techniques. However, the DB method resulted in higher probability of splitting of the fused commissures and less damage caused to the MV leaflets by overstretching.

60 APPLIED LIFE SCIENCES↗

Filter service system

According to an exemplary embodiment of the present disclosure, a system for removing matter from a filtering device includes a gas pressurization assembly. An element of the assembly is removably attachable to a first orifice of the filtering device. The system also includes a vacuum source fluidly connected to a second orifice of the filtering device.

47 OTHER INSTRUMENTATION↗

The Ion Funnel: Theory, Implementations and Applications.

Invented in the 1990s, the ion funnel enabled a new approach for transporting ions through the first vacuum stage of a mass spectrometer, providing much greater transmission efficiencies than other techniques at the time. Rather than use a conical skimmer to sample a small portion of the ions entering the vacuum chamber from the inlet of an electrospray ionization interface, the ion funnel was designed to capture all of the ions in the expanding gas jet and radially focus them for efficient transfer through a conductance limiting orifice at pressures where traditional ion guiding devices failed. While initial designs required high speed pumping and exhibited a strong mass to charge ratio (m/z)-dependent ion transmission bias, subsequent advances guided by theoretical modeling have overcome those limitations to provide consistently large sensitivity gains and robust operation for a wide variety of mass spectrometers. We review the improvements in design and understanding that have brought the ion funnel to its current state of refinement. Novel applications of the ion funnel, which are continually emerging in such diverse fields as ion trapping, ion cooling, low pressure electrospray, and ion mobility spectrometry, are reviewed as well.

02 PETROLEUM↗

Improved DESI-MS Performance using Edge Sampling and aRotational Sample Stage

The position of the surface to be analyzed relative to the sampling orifice or capillary into the mass spectrometer has been known to dramatically affect the observed signal levels in desorption electrospray ionization mass spectrometry (DESIMS). In analyses of sample spots on planar surfaces, DESI-MS signal intensities as much as five times greater were routinely observed when the bottom of the sampling capillary was appropriately positioned beneath the surface plane ( edge sampling") compared to when the capillary just touched the surface. To take advantage of the optimum "edge sampling" geometry and to maximize the number of samples that could be analyzed in this configuration, a rotational sample stage was integrated into a typical DESI-MS setup. The rapid quantitative determination of caffeine in two diet sport drinks (Diet Turbo Tea, Speed Stack Grape) spiked with an isotopically labeled internal standard demonstrated the utility of this approach.

47 OTHER INSTRUMENTATION↗

Onyx Embolization for Occlusion of the Proximal Internal Iliac Artery During EVAR in Patients with Unsuitable Landing Zones in the Common Iliac Artery

Background: Twenty percent of the patients with AAA have an aneurysm involving the common iliac arteries. Large common iliac diameter can be treated with an iliac branched device or extension of the stent graft to the external iliac artery with occlusion of the ipsilateral internal iliac artery (IIA) to prevent type 2 endoleaks. This study describes and evaluates a embolization technique using Onyx in conjunction with EVAR in aneurysms with poor landing zones in the common iliac arteries. Methods: Patients with Onyx IIA embolization during EVAR, identified from the hospital operating code database, constitute the study population. Onyx embolization was performed by injection at the IIA origin. Peri- and postoperative complications were collected from the medical records. Thin-sliced CT scan was performed 1 month and 1 year after the procedure. Results: Thirty-six patients with complex iliac anatomy and insufficient landing zones (without sealing possibility for standard stent grafts) were identified out of 243 consecutive EVAR treatments during a 13-year period. In seventeen patients (7%), the IIA was embolized with Onyx. Technical success was obtained in all 17 patients, without adverse event or procedural complication. No complication related to the embolization procedure was noted during follow-up. Conclusions: During EVAR treatment of patients with aneurysm involving the common iliac artery, Onyx embolization of IIA is a feasible option without need of selective catheterization of the IIA orifice, potentially preserving important branches of the IIA and simplifying emergency procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Neck Stabilization Before EVAR for Infrarenal Aortic Aneurysm in Chronic Aortic Dissection

Background: Endovascular treatment of infrarenal abdominal aortic aneurysm (AAA) with proximal chronic aortic dissection is challenging as a false and true lumen at the level of the infra-renal neck does not allow a sufficient landing zone. We describe staged endovascular neck stabilization prior to standard endovascular aortic repair (EVAR) for AAA with chronic aortic dissection. Technique: To create a stable proximal neck (PN) by closing entry tears, thereby resulting in total false lumen thrombosis (FLT) prior to standard EVAR. Case 1 false lumen fenestrations were present at the descending aorta, the right renal artery orifice and PN. After closing the entry tear by thoracic EVAR, an aortic cuff was placed in the true lumen of the PN and renal stenting for the right renal artery was performed. After 2 months, total FLT was achieved, and EVAR was performed. Case 2 false lumen fenestrations were present at the descending, super celiac aorta and PN. After closing the entry by TEVAR, aortic cuffs were placed at infrarenal aorta to close residual entries. After 1 month of achieving total FLT, EVAR was performed. Both cases had no type 1 endoleak during follow-up. Conclusion: The endovascular neck stabilization is a useful treatment option that facilitates standard EVAR for AAA in chronic aortic dissection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Bath Depth and Nozzle Geometry on Spout Height in Submerged Gas Injection at Bottom

Spout height is a widely used parameter to quantitatively analyze the performance of the submerged gas injection in industrial applications. However, the effect of bath depth and nozzle geometry on spout height in submerged gas injection is still unclear. In this work, the effect of bath depth and nozzle geometry on spout height in submerged gas injection at bottom was experimentally investigated. Circular-shaped, three-leaf-shaped, four-leaf-shaped, and four-flower-shaped nozzles were used for this study. Spout height was extracted from the images captured by high-speed camera and analyzed by digital image processing. The results indicate that the effect of nozzle geometry on spout height is as important as gas flow rate and bath depth. Through dimensional analysis, predictive correlations of spout height from circular shape and four-leaf shape were developed with dimensionless bath depth and a modified Froude number using orifice perimeter and opening area as characteristic parameters. Experimental data were compared with the correlations from literature and good agreement was found.

36 MATERIALS SCIENCE↗

Flame structure of wall-impinging diesel fuel sprays injected by group-hole nozzles

This paper describes an investigation of the flame structure of wall-impinging diesel sprays injected by group-hole nozzles in a constant-volume combustion vessel at experimental conditions typical of a diesel engine. The particular emphasis was on the effect of the included angle between two orifices (0-15 deg. in current study) on the flame structure and combustion characteristics under various simulated engine load conditions. The laser absorption scattering (LAS) technique was applied to analyze the spray and mixture properties. Direct flame imaging and OH chemiluminescence imaging were utilized to quantify the ignition delay, flame geometrical parameters, and OH chemiluminescence intensity. The images show that the asymmetric flame structure emerges in wall-impinging group-hole nozzle sprays as larger included angle and higher engine load conditions are applied, which is consistent with the spray shape observed by LAS. Compared to the base nozzle, group-hole nozzles with large included angles yield higher overall OH chemiluminescence intensity, wider flame area, and greater proportion of high OH intensity, implying the better fuel/air mixing and improved combustion characteristics. The advantages of group-hole nozzle are more pronounced under high load conditions. Based on the results, the feasibility of group-hole nozzle for practical direct injection diesel engines is also discussed. It is concluded that the asymmetric flame structure of a group-hole nozzle spray is favorable to reduce soot formation over wide engine loads. However, the hole configuration of the group-hole nozzle should be carefully considered so as to achieve proper air utilization in the combustion chamber. Stoichiometric diesel combustion is another promising application of group-hole nozzle. (author)

33 ADVANCED PROPULSION SYSTEMS↗

A comparison of injector flow and spray characteristics of biodiesel with petrodiesel.

Performance and emission characteristics of compression ignition engines depend strongly on inner nozzle flow and spray behavior. These processes control the fuel air mixing, which in turn is critical for the combustion process. The differences in the physical properties of petrodiesel and biodiesel are expected to significantly alter the inner nozzle flow and spray structure and, thus, the performance and emission characteristics of the engine. In this study, the inner nozzle flow dynamics of these fuels are characterized by using the mixture-based cavitation model in FLUENT v6.3. Because of its lower vapor pressure, biodiesel was observed to cavitate less than petrodiesel. Higher viscosity of biodiesel resulted in loss of flow efficiency and reduction in injection velocity. Turbulence levels at the nozzle orifice exit were also lower for biodiesel. Using the recently developed KH-ACT model, which incorporates the effects of cavitation and turbulence in addition to aerodynamic breakup, the inner nozzle flow simulations are coupled with the spray simulations in a 'quasi-dynamic' fashion. Thus, the influence of inner nozzle flow differences on spray development of these fuels could be captured, in addition to the effects of their physical properties. Spray penetration was marginally higher for biodiesel, while cone angle was lower, which was attributed to its poor atomization characteristics. The computed liquid lengths of petrodiesel and biodiesel were compared with data from Sandia National Laboratories. Liquid lengths were higher for biodiesel due to its higher boiling temperature and heat of vaporization. Though the simulations captured this trend well, the liquid lengths were underpredicted, which was attributed to uncertainty about the properties of biodiesel used in the experiments. Parametric studies were performed to determine a single parameter that could be used to account for the observed differences in the fuel injection and spray behavior of petrodiesel and biodiesel; fuel temperature seems to be the best parameter to tune.

33 ADVANCED PROPULSION SYSTEMS↗

Thermal analysis of high-pressure hydrogen during the discharging process

The transient temperature and pressure of hydrogen are measured during the hydrogen discharging process through an orifice in a high-pressure vessel. The initial pressures of hydrogen in the vessel are set to approximately 30, 60, and 100 MPa. The mass flow rate and heat flux between hydrogen and the inner wall of the vessel are theoretically estimated using fundamental equations and experimental results with accurate thermophysical properties of hydrogen. The generation of temperature distribution and flow due to heat transfer in the vessel during discharge is verified by numerical analysis. Further, the relationship between reference gas temperature and heat flux in the vessel during the release of high-pressure hydrogen is studied. The average heat flux in the vessel is calculated using experimental and numerical analysis. The appropriate reference temperature is obtained using the comparison of the average heat flux in the vessel. In addition, the dominant heat transfer mode during hydrogen discharge is investigated. Numerical analysis shows that natural convection is formed inside the vessel due to a decrease in temperature. The Nusselt numbers in this process are presented as a function of Rayleigh numbers which are obtained by the experimental results and mass and energy conservations. The relationship between the Nusselt and Rayleigh numbers agrees with the heat transfer correlations of natural convections.

08 HYDROGEN↗

A combined droplet train and ambient pressure photoemission spectrometer for the investigation of liquid/vapor interfaces

We describe a combined ambient pressure photoelectron spectroscopy/droplet train apparatus for investigating the nature and heterogeneous chemistry of liquid/vapor interfaces. In this instrument a liquid droplet train with typical droplet diameters from 50...150 {micro}m is produced by a vibrating orifice aerosol generator (VOAG). The droplets are irradiated by soft X-rays (100...1500 eV) in front of the entrance aperture of a differentially pumped electrostatic lens system that transfers the emitted electrons into a conventional hemispherical electron analyzer. The photoemission experiments are performed at background pressures of up to several Torr, which allows the study of environmentally important liquid/vapor interfaces, in particular aqueous solutions, under equilibrium conditions. The exposure time of the droplet surface to the background gases prior to the XPS measurement can be varied, which will allow future kinetic measurements of gas uptake on liquid surfaces. As an example, a measurement of the surface composition of a {chi} = 0.21 aqueous methanol solution is presented. The concentration of methanol at the vapor/liquid interface is enhanced by a factor of about 3 over the bulk value, while the expected bulk value is recovered at depths larger than about 1.5 nm.

54 ENVIRONMENTAL SCIENCES↗

A spatially resolved retarding field energy analyzer design suitable for uniformity analysis across the surface of a semiconductor wafer

A novel retarding field energy analyzer design capable of measuring the spatial uniformity of the ion energy and ion flux across the surface of a semiconductor wafer is presented. The design consists of 13 individual, compact-sized, analyzers, all of which are multiplexed and controlled by a single acquisition unit. The analyzers were tested to have less than 2% variability from unit to unit due to tight manufacturing tolerances. The main sensor assembly consists of a 300 mm disk to mimic a semiconductor wafer and the plasma sampling orifices of each sensor are flush with disk surface. This device is placed directly on top of the rf biased electrode, at the wafer location, in an industrial capacitively coupled plasma reactor without the need for any modification to the electrode structure. The ion energy distribution, average ion energy, and average ion flux were measured at the 13 locations over the surface of the powered electrode to determine the degree of spatial nonuniformity. The ion energy and ion flux are shown to vary by approximately 20% and 5%, respectively, across the surface of the electrode for the range of conditions investigated in this study.

36 MATERIALS SCIENCE↗

Analytical and experimental studies of leak location and environment characterization for the international space station

The International Space Station program is developing a robotically-operated leak locator tool to be used externally. The tool would consist of a Residual Gas Analyzer for partial pressure measurements and a full range pressure gauge for total pressure measurements. The primary application is to demonstrate the ability to detect NH{sub 3} coolant leaks in the ISS thermal control system. An analytical model of leak plume physics is presented that can account for effusive flow as well as plumes produced by sonic orifices and thruster operations. This model is used along with knowledge of typical RGA and full range gauge performance to analyze the expected instrument sensitivity to ISS leaks of various sizes and relative locations (“directionality”). The paper also presents experimental results of leak simulation testing in a large thermal vacuum chamber at NASA Goddard Space Flight Center. This test characterized instrument sensitivity as a function of leak rates ranging from 1 lb{sub m/}/yr. to about 1 lb{sub m}/day. This data may represent the first measurements collected by an RGA or ion gauge system monitoring off-axis point sources as a function of location and orientation. Test results are compared to the analytical model and used to propose strategies for on-orbit leak location and environment characterization using the proposed instrument while taking into account local ISS conditions and the effects of ram/wake flows and structural shadowing within low Earth orbit.

42 ENGINEERING↗

Development of low-cost, high-performance non-evaporable getter (NEG) pumps

Low-cost, high-performance non-evaporable getter (NEG) pumps were constructed using commercial NEG pills comprising 70 wt% Zr, 24.6 wt% V, and 5.4 wt% Fe, a conflat flange with an outer diameter of 70, 152, or 203 mm (DN 40 CF, DN 100 CF, and DN 160 CF, respectively), and a tantalum heater. After activation at 400 °C for 30 min, the pumping speeds of a DN 40 CF NEG pump measured with the orifice method were 47–40, 8–6, 24–17, and 19–15 L/s for H{sub 2}, N{sub 2}, CO, and CO{sub 2} gasses, respectively. NEG pumps using DN 100 CF and DN 160 CF were also developed, and their pumping speeds are estimated. These NEG pumps are favorable alternatives to sputtering ion pumps in VSX beamlines because they do not produce hydrocarbons except during the activation period. The NEG pumps can also be used for accelerators, front ends, end stations, and differential pumping systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗