Isotope reentry vehicle design study conceptual design. Phase 1B - Topical report
Design evaluation of heat source array for isotope reentry vehicle
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Design evaluation of heat source array for isotope reentry vehicle
Feasibility of analytical error analysis applied to thermal network solutions
Three phase heat transfer with simultaneous condensing and freezing on cold horizontal and vertical plates with corresponding numerical programs
Apollo spacecraft propulsion system propellant management
Preliminary design and performance considerations for 25 kW Pu 238 heat source Isotope Reentry Vehicle
Two phase flow visualization by various photographic and optical methods, describing equipment and lighting used and types of data obtainable
Phase center position of field scattered from hyperboloid subreflector in asymmetric Cassegrain antenna feed system
Auroral pulsation analysis from rocket soundings, investigating oxygen green linear excitation sources
An exact mathematical model is developed for a discrete loop of a general order particularly suitable for digital computation. The deterministic response of the loop to the phase step and the frequency step is investigated. The design of the digital filter for the second-order loop is considered. Use is made of the incremental phase plane to study the phase error behavior of the loop. The model of the noisy loop is derived and the optimization of the loop filter for minimum mean-square error is considered.
Explore the source record for details and available documents.
Sudden phase anomalies (SPA's) observed on VLF recordings are related to sudden ionospheric disturbances due to solar flares. Results are presented for SPA statistics on 500 events observed in New York during the ten year period 1961 to 1970. Signals were at 10.2kHz and 13.6kHz emitted from the OMEGA transmitters in Hawaii and Trinidad. A relationship between SPA frequency and sun spot number was observed. For sun spot number near 85, about one SPA per day will be observed somewhere in the world. SPA activity nearly vanishes during periods of low sun spot number. During years of high solar activity, phase perturbations observed near noon are dominated by SPA effects beyond the 95th percentile. The SPA's can be represented by a rapid phase run-off which is approximately linear in time, peaking in about 6 minutes, and followed by a linear recovery. Typical duration is 49 minutes.
Explore the source record for details and available documents.
Data and analyses related to a variety of algorithms for solving typical large-scale scheduling and resource allocation problems are presented. The capabilities and deficiencies of various alternative problem solving strategies are discussed from the viewpoint of computer system design.
A user guide for the Programming Language for Allocation and Network Scheduling (PLANS) is presented. Information is included for the construction of PLANS programs. The basic philosophy of PLANS is discussed, and access and update reference techniques are described along with the use of tree structures.
Detailed specifications of the prototype language and module library are presented. The user guide to the translator writing system is included.
Nine advanced energy conversion concepts using coal or coal-derived fuels are summarized. They are; (1) open-cycle gas turbines, (2) combined gas-steam turbine cycles, (3) closed-cycle gas turbines, (4) metal vapor Rankine topping, (5) open-cycle MHD; (6) closed-cycle MHD; (7) liquid-metal MHD; (8) advanced steam; and (9) fuel cell systems. The economics, natural resource requirements, and performance criteria for the nine concepts are discussed.
Information is presented on the design, performance, operating characteristics, cost, and development status of coal preparation equipment, combustion equipment, furnaces, low-Btu gasification processes, low-temperature carbonization processes, desulfurization processes, and pollution particulate removal equipment. The information was compiled for use by the various cycle concept leaders in determining the performance, capital costs, energy costs, and natural resource requirements of each of their system configurations.
Open-cycle recuperated gas turbine plant with inlet temperatures of 1255 to 1644 K (1800 to 2500 F) and recuperators with effectiveness values of 0, 70, 80 and 90% are considered. A 1644 K (2500 F) gas turbine would have a 33.5% plant efficiency in a simple cycle, 37.6% in a recuperated cycle and 47.6% when combined with a sulfur dioxide bottomer. The distillate burning recuperated plant was calculated to produce electricity at a cost of 8.19 mills/MJ (29.5 mills/kWh). Due to their low capital cost $170 to 200 $/kW, the open cycle gas turbine plant should see duty for peaking and intermediate load duty.