Search NASA⌕ Search

SEARCH · Search NASA

Results for “PLASMA PRODUCTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Nanosecond pulsed humid Ar plasma jet in air: shielding, discharge characteristics and atomic hydrogen production

Gas phase non-equilibrium plasmas jets containing water vapor are of growing interest for many applications. In this work, we report a detailed study of an atmospheric pressure nanosecond pulsed Ar + 0.26% H 2 O plasma jet. The plasma jet operates in an atmospheric pressure air surrounding but is shielded with a coaxial argon flow to limit the air diffusion into the jet effluent core. The jet impinges on a metal plate electrode and produces a stable plasma filament (transient spark) between the needle electrode in the jet and the metal plate. The stable plasma filament is characterized by spatially and time resolved electrical and optical diagnostics. This includes Rayleigh scattering, Stark broadening of the hydrogen Balmer lines and two-photon absorption laser induced fluorescence (TaLIF) to obtain the gas temperature, the electron density and the atomic hydrogen density respectively. Electron densities and atomic hydrogen densities up to $5 \times 10^{22}$ ${\rm m}^{-3}$ and $2 \times 10^{22}$ ${\rm m}^{-3}$ have been measured. This shows that atomic hydrogen is one of the main species in high density Ar-H 2 O plasmas. The gas temperature does not exceed 550 K in the core of the plasma. To enable in situ calibration of the H TaLIF at atmospheric pressure a previously published O density calibration scheme is extended to include a correction for the line profiles by including overlap integrals as required by H TaLIF. The line width of H TaLIF, due to collision broadening has the same trend as the neutral density obtained by Rayleigh scattering. This suggests the possibility to use this technique to in situ probe neutral gas densities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Role of positive ions on the surface production of negative ions in a fusion plasma reactor type negative ion source—Insights from a three dimensional particle-in-cell Monte Carlo collisions model

Results from a 3D self-consistent Particle-In-Cell Monte Carlo Collisions (PIC MCC) model of a high power fusion-type negative ion source are presented for the first time. The model is used to calculate the plasma characteristics of the ITER prototype BATMAN ion source developed in Garching. Special emphasis is put on the production of negative ions on the plasma grid surface. The question of the relative roles of the impact of neutral hydrogen atoms and positive ions on the cesiated grid surface has attracted much attention recently and the 3D PIC MCC model is used to address this question. The results show that the production of negative ions by positive ion impact on the plasma grid is small with respect to the production by atomic hydrogen or deuterium bombardment (less than 10%)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SPARC 3D Field Physics and Support of the Non-Axisymmetric Coil Assessment

Commonwealth Fusion Systems (CFS) is deploying SPARC, a net-energy tokamak, by 2025. A notable challenge facing all tokamak approaches to fusion energy production is maintaining a stable plasma and thereby steady energy production. “Disruptions” to plasma operation are often encountered in devices when they operate at high normalized pressure, high normalized density, or high normalized current. SPARC is unique in that it is expected to demonstrate Q>=2 in a plasma with low normalized pressure and density, but with a more modest current limit buffer sufficient to avoid disruptions. Due to both the high normalized current and high magnetic field of the SPARC design, it is expected to decrease its relative resilience to instabilities driven by non-axisymmetry in the externally applied magnetic field, termed ‘error fields’. To prevent error field driven instabilities, a primary line of defense is strict engineering tolerances in magnet fabrication and installation. A secondary line of defense is a purpose-built set of magnetic coils to correct these errors, termed error field correction coils (EFCCs). The overarching goals of this INFUSE project were to evaluate the effectiveness of the EFCCs in the SPARC design and provide guidance as to how to improve this effectiveness.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Langmuir Probe and Mass Spectroscopic Measurements in Inductively Coupled CF4 Plasmas

Abstract Electron and ion energy distribution functions and other plasma parameters such as plasma potential (V(sub p)) , electron temperature (T(sub e)), and electron and ion number densities (n (sub e) and n(sub i)) in low pressure CF4 plasmas have been measured. The experiments were conducted in a GEC cell using an inductively coupled plasma (ICP) device powered by a 13.56 MHz radio-frequency (rf) power source. The measurements were made at 300 W of input rf power at 10, 30 and 50 mTorr gas pressures. Langmuir probe measurements suggest that n(sub e), n(sub i) and V(sub p) remain constant over 60% of the central electrode area, beyond which they decrease. Within the limits of experimental error (+/- 0.25 eV), T(sub e) remains nearly constant over the electrode area. T(sub e) and V(sub p) increase with a decrease in pressure. n(sub e) and n(sub i) are not affected as significantly as T(sub e) or V(sub p) by variation in the gas pressure. The electron energy distribution function (EEDF) measurements indicate a highly non-Maxwellian plasma. CF3+ is the most dominant ion product of the plasma, followed by CF2+ and CF+. The concentrations of CF2+ and CF+ are much larger than that is possible from direct electron impact ionization of the parent gas. The cross-section data suggest that the direct electron impact ionization of fragment neutrals and negative ion production by electron attachment may be responsible for increase of the minor ions.

Rao, M. V. V. S.↗

Microgravity Production of Nanoparticles of Novel Materials Using Plasma Synthesis

The research goal is to study the formation in reduced gravity of high quality nanoparticulate of novel materials using plasma synthesis. Particular emphasis will be placed on the production of powders of non-oxide materials like diamond, SiC, SiN, c-BN, etc. The objective of the study is to investigate the effect of gravity on plasma synthesis of these materials, and to determine how the microgravity synthesis can improve the quality and yield of the nanoparticles. It is expected that the reduced gravity will aid in the understanding of the controlling mechanisms of plasma synthesis, and will increase the yield, and quality of the synthesized powder. These materials have properties of interest in several industrial applications, such as high temperature load bearings or high speed metal machining. Furthermore, because of the nano-meter size of the particulate produced in this process, they have specific application in the fabrication of MEMS based combustion systems, and in the development and growth of nano-systems and nano-structures of these materials. These are rapidly advancing research areas, and there is a great need for high quality nanoparticles of different materials. One of the primary systems of interest in the project will be gas-phase synthesis of nanopowder of non-oxide materials.

Frenklach, Michael↗

Venus' nighttime horizontal plasma flow, 'magnetic congestion', and ionospheric hole production

A simple rectilinear, two-dimensional MHD model is used to investigate the effects of field-aligned plasma loss and cooling on a dense plasma convecting across a weak magnetic field, in order to illumine the Venus nighttime phenomena of horizontal plasma flow, magnetic congestion and ionospheric hole production. By parameterizing field-aligned variations and explicitly solving for cross magnetic field variations, it is shown that the abrupt horizontal enhancements of the vertical magnetic field, as well as sudden decreases of the plasma density to very low values (which are characteristic of ionospheric holes), can be produced in the presence of field-aligned losses.

Grebowsky, J. M.↗

Wave frequency dependence of H{sup -} ion production and extraction in a transformer coupled plasma H{sup -} ion source at SNU

The effect of rf wave frequencies on the production of H{sup -} ion is investigated in a transformer coupled plasma H{sup -} ion source at Seoul National University. A Langmuir probe is installed to measure the plasma density and temperature, and these plasma parameters are correlated to the extracted H{sup -} beam currents at various frequencies. The Langmuir probe is also used to measure the density of H{sup -} ions at the ion source by generating photodetachment with an Nd:YAG laser. The extracted H{sup -} currents decrease to a minimum value until 13 MHz and then, increase as the driving frequency increases from 13 MHz while the relative H{sup -} population measured by photodetachment monotonically decreases as the driving rf frequency increases from 11 MHz to 15 MHz. A potential well formed at the extraction region at high frequencies of more than 13 MHz is considered responsible for the increased H{sup -} beam extraction even with a lower photodetachment signal. The variation in the driving rf frequency not only affects the density and temperature of the plasma but also modifies the plasma potential with the existence of a filtering magnetic field and consequently, influences the extracted H{sup -} current through the extraction as well as formation of H{sup -} ions.

43 PARTICLE ACCELERATORS↗

Impact of Xe partial pressure on the production of excimer vacuum ultraviolet emission for plasma display panels

In this work, the effect of the Xe partial pressure on the excimer vacuum ultraviolet (VUV) emission intensity of the plasma display panels is investigated, both by measuring the spectral emission directly and by two-dimensional simulations. Experimentally, we find that at the high Xe partial pressure levels, there is an supra-linear increase of excimer VUV radiation and that determines the strong increase of luminance at the high pressures and high voltage. Due to the increase of the luminance and the almost unchanged discharge current, the luminous efficacy strongly increases with the Xe partial pressure. In addition, we also investigated the dynamics of the VUV generation, by measuring the decay time of the excimer VUV light as a function of the gas pressure. It is found that the decay time decreases with the increase of gas pressure. The spatial characteristics of the excimer VUV emission are also discussed. Different from the Ne and near-infrared emission, the excimer VUV emission is generated near the surface of the electrodes and increases uniformly on both sides of the anode and cathode (i.e., the bulk plasma region). Most importantly, it is found that the VUV production occurs during the afterglow period, while it is almost zero at the moment of the discharge itself. From the simulations, it can be seen that the Xe{sub 2}*({sup 3}{Sigma}{sub u}{sup +}) excimer species, which are generated from Xe*(1s{sub 5}), play a dominant role in the excimer VUV emission output at the high Xe partial pressure. The two-dimensional simulations also show that the strong increase of Xe excimer excitation states in the case of high pressure is mainly the result of the high conversion efficiency of the Xe excimer states, especially in the afterglow period. Due to the high conversion efficiency of Xe excitation species to Xe excimer species by the high collision rate in the case of high pressure, there is a strong increase of excimer VUV production, especially from the cathode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma pressure profiles in a sheared-flow-stabilized Z-pinch

We report the plasma pressure reached inside the central plasma column of a sheared-flow-stabilized Z-pinch using Thomson scattering measurements. Building on previously reported experimental results and the analysis methods established for the high temperature and moderate density plasmas generated on the FuZE device, we show evidence of a central plasma region with higher electron temperature and density, which is consistent with a pinch behavior. Elevated electron temperatures up to 2.25 ± 0.8 keV and densities up to (4.9±0.2)×1017 cm−3 are observed to temporally coincide with the fusion neutron production from the plasma. Reconstructed plasma pressure profiles highlight the presence of a several millimeter-wide column with elevated pressure whose location varies shot-to-shot. The plasma pressure rises as neutron production from the deuterium plasma increases, reaching a peak value of 2.6 kBar. This peak value is consistent with a radially force-balanced pinch equilibrium model based on the measured ∼320 kA pinch current. Complete datasets were obtained at two axial locations, 10 and 20 cm axial position from the tip of the central electrode, which corroborate the estimated neutron source axial lengths.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Role of Penning ionization in the enhancement of streamer channel conductivity and Ar(1s{sub 5}) production in a He-Ar plasma jet

Plasma jet devices that use a helium gas flow mixed with a small percentage of argon have been shown to operate with a larger discharge current and enhanced production of the Ar(1s{sub 5}) metastable state, particularly in the discharge afterglow. In this experiment, time-resolved quantitative measurements of He(2{sup 3}S{sub 1}) and Ar(1s{sub 5}) metastable species were combined with current and spectrally resolved emission measurements to elucidate the role of Penning ionization in a helium plasma jet with a variable argon admixture. The plasma jet was enclosed in a glass chamber through which a flowing nitrogen background was maintained at 600 Torr. At 3%-5% Ar admixture, we observed a {approx}50% increase in the peak circuit current and streamer velocity relative to a pure helium plasma jet for the same applied voltage. The streamer initiation delay also decreased by {approx}20%. Penning ionization of ground-state argon was found to be the dominant quenching pathway for He(2{sup 3}S{sub 1}) up to 2% Ar and was directly correlated with a sharp increase in both the circuit current and afterglow production of Ar(1s{sub 5}) for Ar admixtures up to 1%, but not necessarily with the streamer velocity, which increased more gradually with Ar concentration. Ar(1s{sub 5}) was produced in the afterglow through recombination of Ar{sup +} and dissociative recombination of Ar{sub 2}{sup +} as the local mean electron energy decreased in the plasma channel behind the streamer head. The discharge current and argon metastable enhancement are contingent on the rapid production of He(2{sup 3}S{sub 1}) near the streamer head, >5 Multiplication-Sign 10{sup 12} cm{sup -3} in 30 ns under the conditions of this experiment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pair production rates in mildly relativistic, magnetized plasmas

Electron-positron pairs may be produced by either one or two photons in the presence of a strong magnetic field. In magnetized plasmas with temperatures kT approximately sq mc, both of these processes may be important and could be competitive. The rates of one-photon and two-photon pair production by photons with Maxwellian, thermal bremsstrahlung, thermal synchrotron and power law spectra are calculated as a function of temperature or power law index and field strength. This allows a comparison of the two rates and a determination of the conditions under which each process may be a significant source of pairs in astrophysical plasmas. It is found that for photon densities n(gamma) or = 10 to the 25th power/cu cm and magnetic field strengths B or = 10 to the 12th power G, one-photon pair production dominates at kT approximately sq mc for a Maxwellian, at kT approximately 2 sq mc for a thermal bremsstrahlung spectrum, at all temperatures for a thermal synchrotron spectrum, and for power law spectra with indices s approximately 4.

Burns, M. L.↗

Pair production rates in mildly relativistic magnetized plasmas

Electron-positron pairs may be produced by either one or two photons in the presence of a strong magnetic field. In magnetized plasmas with temperatures kT approximately sq mc, both of these processes may be important and could be competitive. The rates of one-photon and two-photon pair production by photons with Maxwellian, thermal bremsstrahlung, thermal synchrotron and power law spectra are calculated as a function of temperature or power law index and field strength. This allows a comparison of the two rates and a determination of the conditions under which each process may be a significant source of pairs in astrophysical plasmas. It is found that for photon densities n(gamma) or = 10 to the 25th power/cu cm and magnetic field strengths B or = 10 to the 12th power G, one-photon pair production dominates at kT approximately sq mc for a Maxwellian, at kT approximately 2 sq mc for a thermal bremsstrahlung spectrum, at all temperatures for a thermal synchrotron spectrum, and for power law spectra with indices s approximately 4.

Burns, M. L.↗

Dependence of the source performance on plasma parameters at the BATMAN test facility

The investigation of the dependence of the source performance (high j{sub H{sup −}}, low j{sub e}) for optimum Cs conditions on the plasma parameters at the BATMAN (Bavarian Test MAchine for Negative hydrogen ions) test facility is desirable in order to find key parameters for the operation of the source as well as to deepen the physical understanding. The most relevant source physics takes place in the extended boundary layer, which is the plasma layer with a thickness of several cm in front of the plasma grid: the production of H{sup −}, its transport through the plasma and its extraction, inevitably accompanied by the co-extraction of electrons. Hence, a link of the source performance with the plasma parameters in the extended boundary layer is expected. In order to characterize electron and negative hydrogen ion fluxes in the extended boundary layer, Cavity Ring-Down Spectroscopy and Langmuir probes have been applied for the measurement of the H{sup −} density and the determination of the plasma density, the plasma potential and the electron temperature, respectively. The plasma potential is of particular importance as it determines the sheath potential profile at the plasma grid: depending on the plasma grid bias relative to the plasma potential, a transition in the plasma sheath from an electron repelling to an electron attracting sheath takes place, influencing strongly the electron fraction of the bias current and thus the amount of co-extracted electrons. Dependencies of the source performance on the determined plasma parameters are presented for the comparison of two source pressures (0.6 Pa, 0.45 Pa) in hydrogen operation. The higher source pressure of 0.6 Pa is a standard point of operation at BATMAN with external magnets, whereas the lower pressure of 0.45 Pa is closer to the ITER requirements (p ≤ 0.3 Pa)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Non-thermal plasma conversion of hydrocarbons

A non-thermal plasma is generated to selectively convert a precursor to a product. More specifically, plasma forming material and a precursor material are provided to a reaction zone of a vessel. The reaction zone is exposed to microwave radiation, including exposing the plasma forming material and the precursor material to the microwave radiation. The exposure of the plasma forming material to the microwave radiation selectively converts the plasma forming material to a non-thermal plasma including formation of one or more streamers. The precursor material is mixed with the plasma forming material and the precursor material is exposed to the non-thermal plasma including exposing the precursor material to the one or more streamers. The exposure of the precursor material to the streamers and the microwave radiation selectively converts the precursor material to a product.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Accessibility condition of wave propagation and multicharged ion production in electron cyclotron resonance ion source plasma

A new tandem type source of electron cyclotron resonance (ECR) plasmas has been constructing for producing synthesized ion beams in Osaka University. Magnetic mirror field configuration with octupole magnets can be controlled to various shape of ECR zones, namely, in the 2nd stage plasma to be available by a pair mirror and a supplemental coil. Noteworthy correlations between these magnetic configurations and production of multicharged ions are investigated in detail, as well as their optimum conditions. We have been considering accessibility condition of electromagnetic and electrostatic waves propagating in ECR ion source plasma, and then investigated their correspondence relationships with production of multicharged ions. It has been clarified that there exits efficient configuration of ECR zones for producing multicharged ion beams experimentally, and then has been suggested from detail accessibility conditions on the ECR plasma that new resonance, i.e., upper hybrid resonance, must have occurred.

43 PARTICLE ACCELERATORS↗

Human Microdosing with Carcinogenic Polycyclic Aromatic Hydrocarbons: In Vivo Pharmacokinetics of Dibenzo[ def,p ]chrysene and Metabolites by UPLC Accelerator Mass Spectrometry

Metabolism is a key health risk factor following exposures to pro-carcinogenic polycyclic aromatic hydrocarbons (PAHs) such as dibenzo[def,p]chrysene (DBC), an IARC classified 2A probable human carcinogen. Human exposure to PAHs occurs primarily from the diet in non-smokers. However, little data is available on the metabolism and pharmacokinetics in humans of high molecular weight PAHs (≥4 aromatic rings), including DBC. We previously determined the pharmacokinetics of DBC in human volunteers orally administered a micro-dose (29 ng; 5 nCi) of [14C]-DBC by accelerator mass spectrometry (AMS) analysis of total [14C] in plasma and urine. In the current study, we utilized a novel “moving wire” interface between ultra-performance liquid chromatography (UPLC) and AMS to detect and quantify parent DBC and its major metabolites. The major [14C] product identified in plasma was unmetabolized [14C]-DBC itself, (Cmax= 18.5 ± 15.9 fg/mL, Tmax= 2.1 ± 1.0 h), whereas the major metabolite was identified as [14C]-(+/-)-DBC-11,12-diol (Cmax= 2.5 ± 1.3 fg/mL, Tmax= 1.8 h). Several minor species of [14C]-DBC metabolites were also detected for which no reference standards were available. Free and conjugated metabolites were detected in urine with [14C]-(+/-)-DBC-11,12,13,14-tetraol isomers identified as the major metabolites, 56.3% of which were conjugated (Cmax= 35.8 ± 23.0 pg/pool, Tmax= 6-12 h pool). [14C]-DBC-11,12-diol, of which 97.5% was conjugated, was also identified in urine (Cmax= 29.4 ± 11.6 pg/pool, Tmax= 6-12 h pool). Parent [14C]-DBC was not detected in urine. This is the first dataset to assess metabolite profiles and associated pharmacokinetics of a carcinogenic PAH in human volunteers at an environmentally relevant dose, providing the data necessary for translation of high dose animal models to humans for translation of environmental health risk assessment.

Madeen, Erin P.↗

Influence of the Al wire placed in the anode axis on the transformation of the deuterium plasma column in the plasma focus discharge

In this paper, we describe the influence of an Al wire of 270 μm in diameter placed along the anode axis on the transformation of the deuterium pinch column in a megaampere (MA) plasma focus device. The evolution of the pinched column and of the wire corona was investigated by means of the multiframe interferometry, neutron and X-ray diagnostics. The wire corona did not influence considerably on the evolution of dense plasma structures and neutron production, but it increased the plasma density and consequently, the currents around its surface. The distribution of the closed internal currents (ranging hundreds of kA) and associated magnetic fields amounting to 5 T were also estimated in the dense plasma column and in plasmoidal structures at the near-equilibrium state. The description is based on the balance of the plasma pressure and the pressure of the internal poloidal and toroidal current components compressed by the external pinched column. The dominant number of fusion deuterium-deuterium (D-D) neutrons is produced during the evolution of instabilities, when the uninterrupted wire corona (containing deuterium) connects the dense structures of the pinch, and it did not allow the formation of a constriction of the sub-millimeter diameter.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The use of laser-induced shock wave plasma spectroscopy (LISPS) for examining physical characteristics of pharmaceutical products

An experimental study has been performed to examine the physical characteristics of pharmaceutical products, such as tablet, by employing an emission plasma induced by Nd-YAG laser at a low pressure of Helium gas. The hardness of tablet is one of the parameters that examined during the production process for standard quality of pharmaceutical products. In the Laser-Induced Shock Wave Plasma Spectroscopy (LISPS), the shock wave has a significant role in inducing atomic excitation. It was known that, the speed of the shock wavefront depends on the hardness of the sample, and it correlates with the ionization rate of the ablated atoms. The hardness of the tablet is examined using the intensity ratio between the ion of Mg (II) 275.2 nm and the neutral of Mg (I) 285.2 nm emission lines detected from the laser-induced plasma. It was observed that the ratio changes with respect to the change in the tablet hardness, namely the ratio is higher for the hard tablet. Besides the ratio measurements, we also measured the depth profile of a tablet by focusing 60 shots of irradiation of laser light at a fixed position on the surface of the tablet. It was found that the depth profile varies differently with the hardness of the tablet. These experiment results show that the technique of LISPS can be applied to examine the quality of pharmaceutical products.

36 MATERIALS SCIENCE↗