Search NASA⌕ Search

SEARCH · Search NASA

Results for “PV performance modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

De-Risking Large-Scale PV Systems Through Data Analytics

Large-scale photovoltaic system performance analysis is being conducted within the US Department of Energy's-sponsored PV Fleet Performance Data Initiative. This collaboration with commercial PV system owners collects and evaluates PV field performance data, and provides reports on aggregated results. Drawing on over 2200 sites across the US and over 24,000 separate PV inverters we have collected in excess of 8.3 gigawatts (GW) of performance data, representing 6-7% of the entire US installed PV capacity. A mixture of utility-scale and large commercial systems are represented, averaging 4.1 megawatts (MW) in size and 5 years in age. Initial results show average system degradation rates at -0.75% / year, which is slightly higher than historically reported module-level values of -0.5%/year. We also found that the availability of systems averaged 97.7%, which is lower than the typical 99% uptime assumed by many project economic forecasts. Given these results, we compared monthly performance with expected production values, based on satellite weather data and a simple PVWatts performance model. We found that systems were performing within 10% of monthly expectation over 90% of the time, with a fleet average vs expected monthly value of 0.994. We also evaluated the impact of extreme weather events on system performance, and found a range of short-term and longer-term performance effects ranging from grid outage, system downtime, module damage and accelerated long-term degradation rate.

analysis↗

The Impact of Behind-the-Meter Heterogeneous Distributed Energy Resources on Distribution Grids

The increasing integration of distributed energy resources (DERs) on the electric grid brings new challenges and opportunities for utility grid operations. With the rapid deployment of DERs, there is emerging interest in integrating these controllable devices with utility operations at all levels for monitoring and management. To understand the challenges with increasing behind-the-meter (BTM) DERs and to identify the needs in deploying advanced controls, a comprehensive grid impact study is indispensable. This paper presents the analysis which help visualize the DER impact on the grid, identify the challenges and provides an insight into the new distribution management and control needs to enable reliable and resilient grid operations.

behind-the-meter↗

Optimal planning of the joint placement of photovoltaic panels and green roofs under climate change uncertainty

Photovoltaic (PV) panels directly convert sunlight into electricity; but, sunlight also heats the panels, negatively impacting their efficiency. Green roofs are vegetative layers grown on rooftops, mainly to provide added insulation on the roof to save energy. Green roofs also cool near-surface air temperature. Hence, the joint installation of PV panels and green roofs may potentially lead to higher efficiency of PV panels in certain climates. We develop a two-stage stochastic programming model to optimally place PV panels and green roofs under climate change uncertainty to maximize the overall profit from energy generated and saved. We calibrate the model using the literature, industry reports, and the data from different, at times conflicting, climate projections. We then conduct a case study for a mid-size city in the U.S., perform extensive sensitivity and robustness analyses and provide insights.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Area Reports. Advanced materials and devices research area. Silicon materials research task, and advanced silicon sheet task

The objectives of the Silicon Materials Task and the Advanced Silicon Sheet Task are to identify the critical technical barriers to low-cost silicon purification and sheet growth that must be overcome to produce a PV cell substrate material at a price consistent with Flat-plate Solar Array (FSA) Project objectives and to overcome these barriers by performing and supporting appropriate R&D. Progress reports are given on silicon refinement using silane, a chemical vapor transport process for purifying metallurgical grade silicon, silicon particle growth research, and modeling of silane pyrolysis in fluidized-bed reactors.

Source record↗

Modeling and Analysis of Stirling Power Convertors

Modeling and Analysis of Stirling Power Convertors Luis A. Rodriguez1 Steven M. Geng, Terry V. Reid, Scott D. Wilson NASA Glenn Research Center, Cleveland, OH, 44135, USA NASA Glenn’s Thermal Energy Conversion Branch is supporting the development of the next generation free-piston Stirling power convertors. American Superconductor (AMSC) and Sunpower Inc. are the two firms under contract to develop the Flexure Isotope Stirling Convertor (FISC) and the Sunpower Robust Stirling Convertor (SRSC), respectively. To comprehend and forecast convertor performance, Sage, ANSYS® Maxwell, and ANSYS® Fluent were used to model the Stirling thermodynamic cycle, alternator electromagnetics, and piston and displacer dynamics. I. Introduction Stirling convertors are being developed by NASA as a potential steady source of electrical power for NASA’s future scientific space missions. Currently, NASA Glenn Research Center has two corporations under contract, American Superconductor (AMSC) and Sunpower Inc., for the development of the next generation of free-piston Stirling convertors for dynamic radioisotope power systems. AMSC is developing the Flexure Isotope Stirling Convertor (FISC), which uses flexures to prevent side motion and rubbing of the piston. Similarly, Sunpower Inc, is developing the Sunpower Robust Stirling Convertor (SRSC). The SRSC uses gas bearings to prevent radial contact of the moving piston. As convertor development continues, it is increasingly important to understand and predict the interactions of components in the system, how they respond to one another, and how they perform as a response to changes in operating conditions. A suitable and enlightening way to demonstrate and foresee these interactions is with the use of accurate modeling software. Sage, ANSYS® Maxwell, and ANSYS® Fluent are the current modeling tools used by NASA to analytically determine convertor performance. Sage is a one-dimensional object-oriented commercial software package used for modeling and optimizing Stirling convertors for Dynamic Radioisotope Power Systems (DRPS) and it is one of the most accurate Stirling convertor codes in use by NASA. This code is the successor to GLIMPS (Globally-Implicit Stirling Cycle Simulation) and GLOP (GLIMPS Optimization) software created by Gedeon Associates [1]. Model input parameters are typically material/gas type, component physical dimensions, temperatures, frequency, charge pressure, and number of time/space nodes. Sage is used to model both the FISC’s and SRSC’s Stirling cycle thermodynamics and piston/displacer dynamics. Performance maps were created and analyzed for both power systems to better understand the relationship between the following conditions: cold-end temperature, hot-end temperature, piston/displacer amplitudes, pressure drop, and thermal input power. The synergy between these conditions will help determine parameter sensitivity. ANSYS® Maxwell was used to create a three-dimensional (3-D) axisymmetric model for both FISC and SRSC alternators. The significant physical components included in each model are the magnets, magnet carrier, outer/inner laminations, and the coil. Inputs to the model are piston amplitude, piston frequency, alternator load, coil resistance, tuning capacitance, and specific material properties. The alternator models calculate terminal voltage, current, piston/current phase, voltage/current phase, coil inductance, terminal power and efficiency. The RI2 losses, core (hysteresis and eddy) losses, and magnet/can eddy losses are also a part of the final results. ANSYS® Fluent is used to build 3-D computational fluid dynamic (CFD) models to examine the Stirling cycle thermodynamics for both the FISC and SRSC systems. Three-dimensional Computer Aided Design (CAD) models were used to create the physical components of each convertor. Steady-state simulations were conducted for hardware testing, prediction of environmental losses during testing, and generation of radiation look-up tables. The model inputs to the aforementioned analysis are the material properties and boundary thermal conditions. The steady-state model calculates temperature and heat flow distributions. Transient 3-D calculations were also part of the CFD analysis. In this study a physically reduced version of the FISC is used to obtain a prediction of available engine power. For the gas bearing SRSC, the transient effort is used to obtain a prediction of bearing pad performance and its sensitivity to micro-channel geometric variation. The model inputs to the transient simulations are the piston amplitude, displacer amplitude, frequency, displacer/piston phase angle, dynamic deforming CFD grid, temperature boundary conditions, and user defined files describing motion profile of piston/displacer. The results of the model are temperature distributions, heat distributions, and PV power produced at pre-determined conditions.

Luis A Rodriguez↗

Solar and Storage Techno-Economic Analysis Tutorial for the IEEE Photovoltaic Specialist Conference (PVSC)

This tutorial will highlight the most recent efforts from the National Renewable Energy Laboratory (NREL) to track solar photovoltaic (PV) technology trends and manufacturing costs, project levelized cost of electricity (LCOE), and project levelized cost of solar plus storage (LCOSS) for systems across the globe. We will begin with an overview of the global PV supply chain and 2021 benchmark input data for NREL's crystalline silicon (c-Si) and thin film PV module manufacturing cost models. The framework that we follow and will review during this tutorial provides a methodology to prepare bottom-up manufacturing cost models including the items within the U.S. Generally Accepted Accounting Principles (GAAP) and the International Financial Reporting Standards (IFRS). For the polysilicon, wafer, cell conversion, and module assembly steps of the c-Si supply chain, and for thin film modules, we will review input data and methods useful for calculating the costs of goods sold (COGS); research and development (R&D) expenses; and sales, general, and business administration (S, G, &A) expenses. This 2021 benchmark analysis is compiled for state-of-the-art c-Si and thin film module manufacturing. We will also review methods for our 2021 system benchmark costs calculations and LCOE technoeconomic analysis of PV systems and solar plus storage systems. Next generation technologies that lower PV manufacturing and installation costs, reduce operations and maintenance (O&M) expenses, and improve system energy yield will also be highlighted. Techniques for comparing LCOE performance will also be reviewed. We look forward to sharing NREL's extensive work in these areas and discussing ideas for future directions.

cost models↗

Playas Grid Reliability and Distributed Energy Research

The future looks bright for solar and renewable energies in the United States. Recent studies claim that by 2050, solar power could supply a third of all electricity demand in the country’s western states. Technology advances, soft policy changes, and increased energy consciousness will all have to happen to achieve this goal. The New Mexico Institute of Mining and Technology (NMT) and the Department of Homeland Security (DHS) perform various training and research activities at this site. Given its unique nature, Playas was chosen to test Micro-Grids and other examples of renewable distributed energy resources (DER). Several proposed distributed energy sources (DERs) were not implemented as planned including the Micro-Grid. However, Micro-Grid design and computer modeling were completed and these results are included in this report. As part of this research, four PV (solar) generating systems were installed with remote Internet based communication and control capabilities. These systems have been integrated into and can interact with the local grid So that (for example) excess power produced by the solar arrays can be exported to the utility grid. Energy efficient LED lighting was installed in several buildings to further reduce consumption of utility-supplied power. By combining reduced lighting costs; lowering HVAC loads; and installing smart PV generating equipment with energy storage (battery banks) these systems can greatly reduce electrical usage drawn from an older rural electrical cooperative (Co-Op) while providing clean dependable power. Several additional tasks under this project involved conducting research to develop methods of producing electricity from organic materials (i.e. biofuels, biomass. etc.), the most successful being the biodiesel reactor. Improvements with Proton Exchange Membranes (PEM) for fuels cells were demonstrated and advances in Dye Sensitized Solar Cells (DSSC) were also shown. The specific goals of the project include: 1) Instrumentation of the power distribution system with distributed energy resources, demand-side control and intelligent homes within the town of Playas, NM, 2) Creation of models (power flow and dynamic) of the Playas power distribution system, 3) Validation of the models through comparison of predicted behavior to data collected from instrumentation, and 4) Utilization of the models and test grid to characterize the impact of new devices and approaches (e.g., distributed generation and load management) on the local distribution system as well as the grid at large. In addition to the above stated objectives, the research also focused on three critical challenges facing renewable distributed energy platforms: 1) hydrogen from biomass, 2) improved catalyst support systems for electrolysis membranes and fuel cell systems, and 3) improved manufacturing methodologies of low cost photovoltaics. The following sections describe activities performed during this project. The various tasks were focused on establishing Playas as a “…theoretical and experimental test bed…” through which components of a modern/smart grid could be characterized. On a broader scale, project efforts were aimed at development of tools and gathering of experience/expertise that would accelerate progress toward implementation of a modern grid.

09 BIOMASS FUELS↗

PV O&M Cost Model [SWR-21-14]

This tool presents a method for calculating costs associated with the operation and maintenance (O&M) of photovoltaic (PV) systems. The tool compiles details regarding the cost and frequency of multiple O&M services to estimate annual O&M costs ($/year) for each year of an analysis period, the net present value ($) of life cycle costs accumulated over the analysis period, and the reserve account amount ($) that might be required to fund unexpected repairs. The reserve account includes parts inventory and is important for providing a source of funds to make repairs quickly and avoid lost production. This method allows a detailed selection of services to perform based on system size, market served (e.g., residential, commercial, or utility), type and configuration of system components (e.g., micro-, string, or central inverter), and site and environmental conditions (e.g., pollen, bird populations) which is an improvement over simple per unit valuations of O&M costs ($/kW/year). This model also distinguishes costs that vary from year to year and increase at different rates over time as modeled by heuristic failure distributions (e.g., Weibull or Lognormal distribution) based on actuarial data for many of the services.

Walker, Andy↗

Thermodynamics of Light Management in Near-Field Thermophotovoltaics

We evaluate near-field thermophotovoltaic (TPV) energy-conversion systems focusing in particular on their open-circuit voltage (V OC ). Unlike previous analyses based largely on numerical simulations with fluctuational electrodynamics, here, we develop an analytic model that captures the physics of near-field TPV systems and can predict their performance metrics. Using our model, we identify two opportunities of TPV systems operating in the near field. First, we show analytically that enhancement of radiative recombination is a natural consequence of operating in the near field. Second, we note that, owing to photon recycling and minimal radiation leakage in near-field operation, the PV cell used in near-field TPV systems can be much thinner compared to those used in solar PV systems. Since nonradiative recombination is a volumetric effect, use of a thinner cell reduces nonradiative losses per unit area. The combination of these two opportunities leads to increasingly large values of V OC as the TPV vacuum gap decreases. Hence, although operation in the near-field was previously perceived to be beneficial for electrical power-density enhancement, here, we emphasize that thin-film near-field TPVs are also significantly advantageous in terms of V OC and consequently conversion efficiency as well as power density. We provide numerical results for an InAs-based thin-film TPV that exhibits efficiency >50% at an emitter temperature as low as 1100 K.

42 ENGINEERING↗

Concentrating Solar Panels: Bringing the Highest Power and Lowest Cost to the Rooftop

Soliant Energy is a venture-capital-backed startup focused on bringing advanced concentrating solar panels to market. Our fundamental innovation is that we are the first company to develop a racking solar concentrator specifically for commercial rooftop applications, resulting in the lowest LCOE for rooftop electricity generation. Today, the commercial rooftop segment is the largest and fastest-growing market in the solar industry. Our concentrating panels can make a major contribution to the SAI's objectives: reducing the cost of solar electricity and rapidly deploying capacity. Our commercialization focus was re-shaped in 2009, shifting from an emphasis solely on panel efficiency to LCOE. Since the inception of the SAI program, LCOE has become the de facto standard for comparing commercial photovoltaic systems. While estimation and prediction models still differ, the emergence of performance-based incentive (PBI) and feed-in tariff (FIT) systems, as well as power purchase agreement (PPA) financing structures make LCOE the natural metric for photovoltaic systems. Soliant Energy has designed and demonstrated lower-cost, higher-power solar panels that consists of 6 (500X) PV module assemblies utilizing multi-junction cells and an integrated two-axis tracker. In addition, we have designed and demonstrated a prototype 1000X panel assembly with 8. Cost reductions relative to conventional flat panel PV systems were realized by (1) reducing the amount of costly semiconductor material and (2) developing strategies and processes to reduce the manufacturing costs of the entire system. Performance gains against conventional benchmarks were realized with (1) two-axis tracking and (2) higher-efficiency multi-junction PV cells capable of operating at a solar concentration ratio of 1000X (1000 kW/m2). The program objectives are: (1) Develop a tracking/concentrating solar module that has the same geometric form factor as a conventional flat, roof mounted photovoltaic (PV) panel - the Soliant module will produce more power and cost less than conventional panels of the same size; (2) Target LCOE: $0.079/kWh in 2010; (3) Target efficiency - 26% in 2010 (22% for 2008 prototype, 24% for 2009 pilot); and (4) Target performance - equivalent to 650Wp in 2010 (490W for 2008 prototype, 540W for 2009 pilot).

14 SOLAR ENERGY↗

Foresee the Future: Using Machine Learning, Climate, and Site Characteristics to Predict PV Solar Plant Generation

Accurately predicting power generation for PV sites is critical for prioritizing relevant operations & maintenance activities, thereby extending the lifetime of a system and increasing the amount of revenue generated. Machine learning techniques can help us in this regard by providing more accurate predictions of PV power production, such that the forecasts take into account not only a site's system design characteristics, but also important weather and climate information. This type of research is important because we can leverage the vast amounts of SCADA data we collect to build more effective, accurate models that can help improve our performance management.

14 SOLAR ENERGY↗

Frequency Analysis of Solar PV Power to Enable Optimal Building Load Control

In this paper, we present a flexibility estimation mechanism for buildings’ thermostatically controlled loads (TCLs) to enable the distribution level consumption of the majority of solar photovoltaic (PV) generation by local building TCLs. The local consumption of PV generation provides several advantages to the grid operation as well as the consumers, such as reducing the stress on the distribution network, minimizing voltage fluctuations and two-way power flows in the distribution network, and reducing the required battery storage capacity for PV integration. This would result in increasing the solar PV generation penetration levels. The aims of this study are twofold. First, spectral (frequency) analyses of solar PV power generation together with the power consumption of multiple building TCLs (such as heating, ventilation, and air conditioning (HVAC) systems, water heaters, and refrigerators) are performed. These analyses define the bandwidth over which these TCLs can operate and also describe the PV generation frequency bandwidth. Such spectral analyses, in frequency domain, can help identify the flexible components of PV generation that can be consumed by the various TCLs through optimal building load utilization. Second, a quadratic optimization problem based on model predictive control is formulated to allow consuming most of the low and medium frequency content of the PV power locally by building TCLs, while maintaining occupants’ comfort and TCLs’ physical constraints. The solution to the proposed optimization problem is achieved using optimal control strategies. Numerical results show that most of the low and medium frequency content of the PV generation can be consumed locally by building TCLs. The remaining high-frequency content of the PV generation can then be stored/offset using energy storage systems.

14 SOLAR ENERGY↗

Community-Scale Energy Efficiency Assessment for Zero Net Energy Using the URBANopt Simulation Platform: Preprint

This project explored an innovative modeling approach for assessing the energy efficiency potential of the existing low-income Oceano neighborhood, in unincorporated San Luis Obispo County, and its effects on renewable generation requirements for achieving zero net energy (ZNE). One particular challenge faced was ascertaining the technical energy savings potential across a large neighborhood in a timely manner. The project overcame this challenge through the use of the URBANopt simulation platform, developed at the National Renewable Energy Laboratory. URBANopt manages the automated model creation, simulation, and result aggregation for different design scenarios of existing or candidate buildings in a large neighborhood. Customized energy efficiency packages considered for the residential and commercial sector in the neighborhood included lighting, HVAC, plug load, water heating, envelope, and energy education measures. As a result of the analysis for the Oceano community, energy efficiency measures that are available through incentive programs may provide a 7.4% reduction in the required distributed energy resource (DER) size, corresponding to a 25,000 ft2 decrease in PV array area, to achieve ZNE. Through this work, a computational tool was developed and is being leveraged by the County of San Luis Obispo (CoSLO). The tool has enabled the CoSLO staff to perform similar analysis of the technical potential for energy efficiency, and an understanding of the DER asset requirements and potential savings in other communities within the county.

building energy modeling↗

Improving the Performance of Integrated Power-Hardware-in-the-Loop and Quasi-Static Time-Series Simulations

This paper introduces a novel multirate cosimulation architecture that overcomes previous challenges integrating faster real-time, microseconds-scale, power-hardware-in-the-loop (PHIL) with larger scale but slower, real-time, seconds-scale, quasi-static time-series (QSTS) simulation. Specifically, an intermediate reduced-equivalent electromagnetic transient (EMT) model duplicates the key power system topology to capture high-speed dynamics and converge hardware-power system interactions between QSTS updates. Exchanging multidimensional parameter vectors (loads, control status, etc.) between the QSTS and EMT models enables capturing the interactions of the rich, high-node-count (thousands of electrical nodes) QSTS model with the hardware. This architecture offers full spatial resolution from QSTS, including individual load dynamics, actual distribution management system controls, and nodal voltages. Simultaneously, the intermediate EMT model provides more detailed high-speed transients of key distributed energy resource hardware interactions. In addition, we use careful PHIL interface design and the exchange of complex power data, rather than current, to further improve performance. This cosimulation architecture is demonstrated by testing a simulated distribution system with an interconnected 500-kVA advanced photovoltaic (PV) inverter in PHIL. In conclusion, the architecture successfully captured PV local volt-volt ampere reactive (volt-VAR) control interactions with the larger network under time-varying electrical and weather conditions.

42 ENGINEERING↗

A Real-Time Degradation Estimation Approach for Batteries in PV and Battery Hybrid Plant Operation

Conventional cyclic degradation assessment for batteries is often limited in its ability to provide real-time degradation information during operation, because the estimation of degradation is commonly performed after a specific evaluation period. Modified methods can provide real-time evaluation but at the cost of high computation complexity. This paper proposes a novel estimation method that addresses these limitations. It efficiently determines the incremental degradation of any two consecutive state-of-charge (SOC) samples during battery operation, thus enabling real-time estimation. To validate the proposed method, measurement data from lithium-ion phosphate (LFP) battery testing was adopted, and the results were compared with the conventional model and the measured capacity. The results demonstrate accuracy over the evaluation period in terms of cumulative degradation, and a reduced computation cost compared with other methods. This approach has benefits in various applications, especially in cases where batteries experience irregular charging and discharging stress cycles such as PV and battery hybrid plants.

Wang, Shumeng↗

Development Support for NREL's System Advisor Model (SAM): Cooperative Research and Development, CRADA Number CRD-20-16998 (Final Report)

The variable nature of renewable generation, which depends on the sun shining and wind blowing for example, presents challenges for adequate and least-cost resource planning. The deployment of renewable generation assets is anticipated to increase due to various drivers, such as declining costs, favorable government policies, and increasing procurement by corporations and consumers. High levels of renewable penetration are anticipated to pose flexibility, reliability, and cost challenges to the electrical system. The development and implementation of new features into performance modeling software, such as the National Renewable Energy Laboratory's (NREL) System Advisor Model (SAM), is one way to help think through these challenges and develop appropriate strategies.

14 SOLAR ENERGY↗

Barriers and variable spacing enhance convective cooling and increase power output in solar PV plants

When the temperature of solar photovoltaic (PV) modules rises, efficiency drops and module degradation accelerates. Thus, it is beneficial to reduce module operating temperatures. Previous studies of solar power plants have illustrated that incoming flow characteristics, turbulent mixing, and array geometry can strongly impact convective cooling, as measured by the convective heat transfer coefficient h. In the fields of heat transfer and plant canopy flow, previous work has shown that system-scale arrangement modifications—e.g., variable spacing, barriers, or windbreaks—can passively alter the flow, enhance turbulent mixing, and influence convection. However, researchers have not yet explored how variable spacing or barriers might enhance convective cooling in solar power plants. Here, high-resolution large-eddy simulations model the air flow and heat transfer through solar power plant arrangements modified with missing modules and barrier walls. We then perform a control volume analysis to evaluate the net heat flux and compute h, which quantifies the influence of these spatial modifications on convective cooling and, thus, module temperature and power output. Installing barrier walls yields the greatest improvements, increasing h by 3.4%, reducing module temperature by an estimated 2.5 °C, and boosting power output by an estimated 1.4% on average. These findings indicate that incorporating variable spacing or barrier-type elements into PV plant designs can reduce module temperature and, thus, improve PV performance and service life.

14 SOLAR ENERGY↗

Measurement of the parity-violating asymmetry in inclusive electroproduction of π - near the Delta 0 resonance

The parity-violating (PV) asymmetry of inclusive π - production in electron scattering from a liquid deuterium target was measured at backward angles. The measurement was conducted as a part of the G0 experiment, at a beam energy of 360 MeV. The physics process dominating pion production for these kinematics is quasi-free photoproduction off the neutron via the Δ 0 resonance. In the context of heavy-baryon chiral perturbation theory (HBχPT), this asymmetry is related to a low energy constant d Δ - that characterizes the parity-violating γNΔ coupling. Zhu et al. calculated d Δ - in a model benchmarked by the large asymmetries seen in hyperon weak radiative decays, and predicted potentially large asymmetries for this process, ranging from A γ - = -5.2 to +5.2 ppm. The measurement performed in this work leads to A γ - = -0.36 ± 1.06 ± 0.37 ± 0.03 ppm (where sources of statistical, systematic and theoretical uncertainties are included), which would disfavor enchancements considered by Zhu et al. proportional to V ud /V us . The measurement is part of a program of inelastic scattering measurements that were conducted by the G0 experiment, seeking to determine the N-Δ axial transition form-factors using PV electron scattering.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗