Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Simple and efficient relaxation methods for interfaces separating compressible fluids, cavitating flows and shocks in multiphase mixtures

Numerical approximation of the five-equation two-phase flow of Kapila et al. [A.K. Kapila, R. Menikoff, J.B. Bdzil, S.F. Son, D.S. Stewart, Two-phase modeling of deflagration-to-detonation transition in granular materials: reduced equations, Physics of Fluids 13(10) (2001) 3002-3024] is examined. This model has shown excellent capabilities for the numerical resolution of interfaces separating compressible fluids as well as wave propagation in compressible mixtures [A. Murrone, H. Guillard, A five equation reduced model for compressible two phase flow problems, Journal of Computational Physics 202(2) (2005) 664-698; R. Abgrall, V. Perrier, Asymptotic expansion of a multiscale numerical scheme for compressible multiphase flows, SIAM Journal of Multiscale and Modeling and Simulation (5) (2006) 84-115; F. Petitpas, E. Franquet, R. Saurel, O. Le Metayer, A relaxation-projection method for compressible flows. Part II. The artificial heat exchange for multiphase shocks, Journal of Computational Physics 225(2) (2007) 2214-2248]. However, its numerical approximation poses some serious difficulties. Among them, the non-monotonic behavior of the sound speed causes inaccuracies in wave's transmission across interfaces. Moreover, volume fraction variation across acoustic waves results in difficulties for the Riemann problem resolution, and in particular for the derivation of approximate solvers. Volume fraction positivity in the presence of shocks or strong expansion waves is another issue resulting in lack of robustness. To circumvent these difficulties, the pressure equilibrium assumption is relaxed and a pressure non-equilibrium model is developed. It results in a single velocity, non-conservative hyperbolic model with two energy equations involving relaxation terms. It fulfills the equation of state and energy conservation on both sides of interfaces and guarantees correct transmission of shocks across them. This formulation considerably simplifies numerical resolution. Following a strategy developed previously for another flow model [R. Saurel, R. Abgrall, A multiphase Godunov method for multifluid and multiphase flows, Journal of Computational Physics 150 (1999) 425-467], the hyperbolic part is first solved without relaxation terms with a simple, fast and robust algorithm, valid for unstructured meshes. Second, stiff relaxation terms are solved with a Newton method that also guarantees positivity and robustness. The algorithm and model are compared to exact solutions of the Euler equations as well as solutions of the five-equation model under extreme flow conditions, for interface computation and cavitating flows involving dynamics appearance of interfaces. In order to deal with correct dynamic of shock waves propagating through multiphase mixtures, the artificial heat exchange method of Petitpas et al. [F. Petitpas, E. Franquet, R. Saurel, O. Le Metayer, A relaxation-projection method for compressible flows. Part II. The artificial heat exchange for multiphase shocks, Journal of Computational Physics 225(2) (2007) 2214-2248] is adapted to the present formulation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The DOSIMAP, a high spatial resolution tissue equivalent 2D dosimeter for LINAC QA and IMRT verification

The continual need for more accurate and effective techniques in radiation therapy makes it necessary to devise new control means combining high spatial resolution as well as high dose accuracy. Intensity modulated radio therapy (IMRT) allows highly conformed fields with high spatial gradient and therefore requires a precise monitoring of all the multileaf positions. In response to this need, the authors have developed a new 2D tissue equivalent dosimeter with high spatial resolution. A plastic scintillator sheet is sandwiched between two polystyrene blocks and the emitted light is captured by a high resolution camera. A newly developed procedure described herein allows efficient discrimination of the scintillation from the parasitic Cerenkov radiation. This processing is applied on the cumulated image from a sequence of images taken during an irradiation field at a rate of 10 images/s. It provides a high resolution mapping of the cumulated dose in quasireal time. The dosimeter is tissue equivalent (ICRU-44) and works both for electrons and photons without complex parameter adjustment since phantom and detector materials are identical. Instrument calibration is simple and independent of the irradiation conditions (energy, fluence, quality, ...). In this article, the authors present the principle of the dosimeter and its calibration procedure. They compare the results obtained for photons and electron beams with ionization chamber measurements in polystyrene. Technical specifications such as accuracy and repeatability are precisely evaluated and discussed. Finally, they present different IMRT field measurements and compare DOSIMAP measurements to TPS simulations and dosimetric film profiles. The results confirm the excellent spatial resolution of the instrument and its capacity to inspect the leaf positions for each segment of a given field.

61 RADIATION PROTECTION AND DOSIMETRY↗

Offshore wind speed estimates from a high‐resolution rapidly updating numerical weather prediction model forecast dataset

Abstract In association with the Department of Energy–funded Position of Offshore Wind Energy Resources (POWER) project, we present results from compositing a 3‐year dataset of 80‐m (above ground level) wind forecasts from the 3‐km High‐Resolution Rapid Refresh (HRRR) model over offshore regions for the contiguous United States. The HRRR numerical weather prediction system runs once an hour and features hourly data assimilation, providing a key advantage over previous model‐based offshore wind datasets. On the basis of 1‐hour forecasts from the HRRR model, we highlight the different climatological regimes of the nearshore environment, characterizing the mean 80‐m wind speed as well as the frequency of exceeding 4, 12, and 25 m s −1 for east and west coast, Gulf of Mexico, and Great Lake locations. Preliminary verification against buoy measurements demonstrates good agreement with observations. This dataset can inform the placement of targeted measurement systems in support of improving resource assessments and wind forecasts to advance offshore wind energy goals both in New England and other coastal regions of the United States.

James, Eric P.↗

Evolutionary determination of experimental parameters for ptychographical imaging

The Ptychographical Iterative Engine (PIE) algorithm is a recently developed novel method of Coherent Diffractive Imaging (CDI) that uses multiple overlapping diffraction patterns to reconstruct an image. This method has successfully produced high quality reconstructions at both optical and X-ray wavelengths but the need for accurate knowledge of the probe positions is currently a limiting factor in the production of high resolution reconstructions at electron wavelengths. This paper examines the shape of the search landscape for producing optimal image reconstructions in the specific case of electron microscopy and then shows how evolutionary search methods can be used to reliably determine experimental parameters in the electron microscopy case (such as the spherical aberration in the probe and the probe positions).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time-resolved studies of particle effects in laser ablation inductively coupled plasma-mass spectrometry

Transient signal responses for ablated samples as a function of particle size and laser parameters are characterized. Data are acquired with time resolution of 5 or 6 ms per data point. Large positive spikes in signal are observed and increase in both amplitude and frequency with increasing particle size. Particle sizes are selected using a differential mobility analyzer. Spikes in the signal also increase with decreasing laser rastering rates. A comparison of lasers with pulse widths of 370 fs and 5 ns shows that shortening the pulse width significantly reduces the frequency and amplitude of positive spikes in signal. These large positive spikes are attributed to the vaporization, atomization, and ionization of individual large intact particles, which are considered to be a major cause of fractionation in laser ablation ICP-MS.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The effects of Doppler broadening and detector resolution on the performance of three-stage Compton cameras

Purpose: The authors investigated how the characteristics of the detectors used in a three-stage Compton camera (CC) affect the CC's ability to accurately measure the emission distribution and energy spectrum of prompt gammas (PG) emitted by nuclear de-excitations during proton therapy. The detector characteristics they studied included the material (high-purity germanium [HPGe] and cadmium zinc telluride [CZT]), Doppler broadening (DB), and resolution (lateral, depth, and energy). Methods: The authors simulated three-stage HPGe and CZT CCs of various configurations, detecting gammas from point sources with energies ranging from 0.511 to 7.12 MeV. They also simulated a proton pencil beam irradiating a tissue target to study how the detector characteristics affect the PG data measured by CCs in a clinical proton therapy setting. They used three figures of merit: the distance of closest approach (DCA) and the point of closest approach (PCA) between the measured and actual position of the PG emission origin, and the calculated energy resolution. Results: For CCs with HPGe detectors, DB caused the DCA to be greater than 3 mm for 14% of the 6.13 MeV gammas and 20% of the 0.511 MeV gammas. For CCs with CZT detectors, DB caused the DCA to be greater than 3 mm for 18% of the 6.13 MeV gammas and 25% of the 0.511 MeV gammas. The full width at half maximum (FWHM) of the PCA in the z-caret direction for HPGe and CZT detectors ranged from 1.3 to 0.4 mm for gammas with incident energy ranging from 0.511 to 7.12 MeV. For CCs composed of HPGe detectors, the resolution of incident gamma energy calculated by the CC ranged from 6% to 1% for gammas with true incident energies from 0.511 to 7.12 MeV. For CCs composed of CZT detectors, the resolution of gamma energy calculated by the CC ranged from 10% to 1% for gammas with true incident energies from 0.511 to 7.12 MeV. For HPGe and CZT CCs in which all detector effect were included, the DCA was less than 3 mm for 75% and 68% of the detected gammas, respectively, and restricting gammas to those having energy greater than 2.0 MeV increased these percentages to 83% and 77% for HPGe and CZT, respectively. Distributions of the true gamma origins and the PCA after detector characteristics had been included showed good agreement on beam range and some loss of resolution for the lateral profile of the PG emission. Characteristic energy lines were evident in the calculated gamma energy spectrum. Conclusions: The authors found the following: (1) DB is the dominant source of spatial and energy resolution loss in the CCs at all energy levels; (2) the largest difference in the spatial resolution of HPGe and CZT CCs is that the spatial resolution distributions of CZT have broader tails. The differences in the FWHM of these distributions are small; (3) the energy resolution of both HPGe and CZT three-stage CCs is adequate for PG spectroscopy; and (4) restricting the gammas to those having energy greater than 2.0 MeV can improve the achievable image resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resolution of the Electron Microscope at the Atomic Scale

The importance of atomic-resolution electron microscopy as a tool for structure analysis lies in its ability to produce images in which each peak corresponds to the position of an atom (or atomic column) within the specimen. Being able to distinguish between atoms (or columns) that appear close together when projected in the chosen viewing direction depends on the resolution of the microscope. Knowledge of the resolution of any particular electron microscope is crucial to judge if its resolution is appropriate for the specimen. In addition, resolution quality will determine the precision of measured atom positions.

A-OK↗

Stabilization of ZnMnO3 Phase from Sol-gel Synthesized Nitrate Precursors

The stabilization and analysis of pure ZnMnO3 spinel phase may help to understand the solubility limits of Mn in ZnO in wurtzite and spinel cubic structures. In this report, synthesis and characterization of stable ZnMnO3 phase is discussed which is extracted from sol-gel synthesis of zinc and manganese nitrate precursors. The reflections at higher diffraction angles for this known cubic system with space group Fd3m were calculated with the help of JADE 8.0 program. High resolution X-ray photoelectron spectroscopy measurements of Mn3p position of ZnMnO3 compared with ZnMn2O4 showed a higher binding energy shift ~0.85 eV indicating Mn4+ valence state in ZnMnO3.

36 MATERIALS SCIENCE↗

The differnces between bond lengths in biogenic and geologocal calcite.

We used high-resolution neutron powder diffraction to accurately measure the atomic positions and bond lengths in biogenic and geological calcite. A special procedure for data analysis was developed in order to take into account the considerable amounts of magnesium present in all the investigated samples. As a result, in biogenic calcite we found some atomic bonds to have significantly different lengths as compared to those in geological calcite, after the contribution of magnesium is accounted for. The maximum effect (elongation up to 0.7%) was found for the C-O bonds. We also analyzed changes in frequencies and spectral widths of normal vibrations of carbonate groups in biogenic calcite (as compared to geological calcite) measured by Raman and Fourier transform IR techniques. Surprisingly, the frequency shifts after subtracting the magnesium contribution are close to zero. At the same time, substantial spectral broadening (up to 1.2%) in biogenic calcite as compared to geological samples was detected. Possible explanations for the experimental findings are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

X-Ray reduction imaging of inclined reflective masks at critical angles

We have proposed and simulated optical schemes for producing reduced images by X-ray lasers or harmonic generators at a wavelength of ∼14 nm. The mask in this case is placed at a small angle to the optical axis, corresponding to the angle of total external reflection of the material. We have determined the optimal position of the detector (resist) and the corresponding spatial resolution. The results can be used to solve problems in nanotechnology and nanostructuring of surfaces. (x-ray optics)

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A HIGH-RESOLUTION MASS MAP OF GALAXY CLUSTER SUBSTRUCTURE: LensPerfect ANALYSIS OF A1689

We present a strong lensing (SL) mass model of A1689 which resolves substructures an estimated 25 kpc across within the central {approx}400 kpc diameter. We achieve this resolution by perfectly reproducing the observed (strongly lensed) input positions of 168 multiple images of 55 knots residing within 135 images of 42 galaxies. Our model makes no assumptions about light tracing mass, yet we reproduce the brightest visible structures with some slight deviations. A1689 remains one of the strongest known lenses on the sky, with an Einstein radius of R{sub E} = 47.''0 {+-} 1.''2 (143{sup +3}{sub -4} kpc) for a lensed source at z{sub s} = 2. We find that a single Navarro-Frenk-White (NFW) or Sersic profile yields a good fit simultaneously (with only slight tension) to both our SL mass model and published weak lensing (WL) measurements at larger radius (out to the virial radius). According to this NFW fit, A1689 has a mass of M{sub vir} = 2.0{sup +0.5}{sub -0.3} x 10{sup 15} M{sub sun} h {sup -1}{sub 70} (M{sub 200} = 1.8{sup +0.4}{sub -0.3} x 10{sup 15} M{sub sun} h {sup -1}{sub 70}) within the virial radius r{sub vir} = 3.0 {+-} 0.2 Mpc h {sup -1}{sub 70} (r{sub 200} = 2.4{sup +0.1}{sub -0.2} Mpc h {sup -1}{sub 70}), and a central concentration c{sub vir} = 11.5{sup +1.5}{sub -1.4} (c{sub 200} = 9.2 {+-} 1.2). Our SL model prefers slightly higher concentrations than previous SL models, bringing our SL + WL constraints in line with other recent derivations. Our results support those of previous studies which find A1689 has either an anomalously large concentration or significant extra mass along the line of sight (perhaps in part due to triaxiality). If clusters are generally found to have higher concentrations than realized in simulations, this could indicate that they formed earlier, perhaps as a result of early dark energy.

79 ASTRONOMY AND ASTROPHYSICS↗

Demonstration of tokamak vertical stability control based on non-inductive Faraday-effect polarimetry measurements

Long-pulse or steady-state fusion reactors are envisioned to control vertical stability based on non-inductive measurements, i.e. that do not rely on temporal change of magnetic field. For the first time, vertical stability control using non-inductive Faraday-effect polarimetry measurements has been demonstrated. The Radial Interferometer-Polarimeter system on DIII-D is capable of microsecond resolution and was used to absolutely determine the vertical position of the plasma magnetic axis Z 0 . A vertical stability controller was developed to robustly stabilize diverted plasmas using Faraday-based measurements. The system was able to stabilize against vertical displacement events with growth rates up to 350 s -1 in elongated and elliptical plasma shapes, and instabilities with even higher growth rates are likely to be controllable with further improvements to controller tuning. Tests show that the Faraday-based controller remains effective and is capable of recovering from loss of control even when the plasma vertical position is far from the region where the linear model used to calculate Z 0 is most valid. Faraday control has also been activated during plasma ramp-up, demonstrating the robustness of the technique to larger systematic diagnostic uncertainty at low electron density.

Faraday-effect polarimetry↗

WE-FG-206-05: New Arterial Spin Labeling Method for Simultaneous Estimation of Arterial Cerebral Blood Volume, Cerebral Blood Flow and Arterial Transit Time

Purpose: To demonstrate the feasibility of a novel Arterial Spin Labeling (ASL) method for simultaneously measuring cerebral blood flow (CBF), arterial transit time (ATT), and arterial cerebral blood volume (aCBV) without the use of a contrast agent. Methods: A series of multi-TI ASL images were acquired from one healthy subject on a 3T Siemens Skyra, with the following parameters: PCASL labeling with variable TI [300, 400, 500, 600, 700, 800, 900, 1000, 1500, 2000, 2500, 3000, 3500, 4000] ms, labeling bolus 1400 ms when TI allows, otherwise 100 ms less than TI, TR was minimized for each TI, two sinc shaped pre-saturation pulses were applied in the imaging plane immediately before 2D EPI acquisition. 64×64×24 voxels, 5 mm slice thickness, 1 mm gap, full brain coverage, 6 averages per TI, no crusher gradients, 11 ms TE, scan time of 4:56. The perfusion weighted time-series was created for each voxel and fit to a novel model. The model has two components: 1) the traditional model developed by Buxton et al., accounting for CBF and ATT, and 2) a box car function characterizing the width of the labeling bolus, with variable timing and height in proportion to the aCBV. All three parameters were fit using a nonlinear fitting routine that constrained all parameters to be positive. The main purpose of the high-temporal resolution TI sampling for the first second of data acquisition was to precisely estimate the blood volume component for better detection of arrival time and magnitude of signal. Results: Whole brain maps of CBF, ATT, and aCBV were produced, and all three parameters maps are consistent with similar maps described in the literature. Conclusion: Simultaneous mapping of CBF, ATT, and aCBV is feasible with a clinically tractable scan time (under 5 minutes).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Delivered dose uncertainty analysis at the tumor apex for ocular brachytherapy

Purpose: To estimate the total dosimetric uncertainty at the tumor apex for ocular brachytherapy treatments delivered using 16 mm Collaborative Ocular Melanoma Study (COMS) and Super9 plaques loaded with {sup 125}I seeds in order to determine the size of the apex margin that would be required to ensure adequate dosimetric coverage of the tumor. Methods: The total dosimetric uncertainty was assessed for three reference tumor heights: 3, 5, and 10 mm, using the Guide to the expression of Uncertainty in Measurement/National Institute of Standards and Technology approach. Uncertainties pertaining to seed construction, source strength, plaque assembly, treatment planning calculations, tumor height measurement, plaque placement, and plaque tilt for a simple dome-shaped tumor were investigated and quantified to estimate the total dosimetric uncertainty at the tumor apex. Uncertainties in seed construction were determined using EBT3 Gafchromic film measurements around single seeds, plaque assembly uncertainties were determined using high resolution microCT scanning of loaded plaques to measure seed positions in the plaques, and all other uncertainties were determined from the previously published studies and recommended values. All dose calculations were performed using PLAQUESIMULATOR v5.7.6 ophthalmic treatment planning system with the inclusion of plaque heterogeneity corrections. Results: The total dosimetric uncertainties at 3, 5, and 10 mm tumor heights for the 16 mm COMS plaque were 17.3%, 16.1%, and 14.2%, respectively, and for the Super9 plaque were 18.2%, 14.4%, and 13.1%, respectively (all values with coverage factor k = 2). The apex margins at 3, 5, and 10 mm tumor heights required to adequately account for these uncertainties were 1.3, 1.3, and 1.4 mm, respectively, for the 16 mm COMS plaque, and 1.8, 1.4, and 1.2 mm, respectively, for the Super9 plaque. These uncertainties and associated margins are dependent on the dose gradient at the given prescription depth, thus resulting in the changing uncertainties and margins with depth. Conclusions: The margins determined in this work can be used as a guide for determining an appropriate apex margin for a given treatment, which can be chosen based on the tumor height. The required margin may need to be increased for more complex scenarios (mushroom shaped tumors, tumors close to the optic nerve, oblique muscle related tilt, etc.) than the simple dome-shaped tumor examined and should be chosen on a case-by-case basis. The sources of uncertainty contributing most significantly to the total dosimetric uncertainty are seed placement within the plaques, treatment planning calculations, tumor height measurement, and plaque tilt. This work presents an uncertainty-based, rational approach to estimating an appropriate apex margin.

60 APPLIED LIFE SCIENCES↗

Construction of high resolution genetic linkage maps to improve the soybean genome sequence assembly Glyma1.01

Background. A landmark in soybean research, Glyma1.01, the first whole genome sequence of variety Williams 82 (Glycine max L. Merr.) was completed in 2010 and is widely used. However, because the assembly was primarily built based on the linkage maps constructed with a limited number of markers and recombinant inbred lines (RILs), the assembled sequence, especially in some genomic regions with sparse numbers of anchoring markers, needs to be improved. Molecular markers are being used by researchers in the soybean community, however, with the updating of the Glyma1.01 build based on the high-resolution linkage maps resulting from this research, the genome positions of these markers need to be mapped. Results. Two high density genetic linkage maps were constructed based on 21,478 single nucleotide polymorphism loci mapped in the Williams 82 x G. soja (Sieb. & Zucc.) PI479752 population with 1083 RILs and 11,922 loci mapped in the Essex x Williams 82 population with 922 RILs. There were 37 regions or single markers where marker order in the two populations was in agreement but was not consistent with the physical position in the Glyma1.01 build. In addition, 28 previously unanchored scaffolds were positioned. Map data were used to identify false joins in the Glyma1.01 assembly and the corresponding scaffolds were broken and reassembled to the new assembly, Wm82.a2.v1. Based upon the plots of the genetic on physical distance of the loci, the euchromatic and heterochromatic regions along each chromosome in the new assembly were delimited. Genomic positions of the commonly used markers contained in BARCSOYSSR_1.0 database and the SoySNP50K BeadChip were updated based upon the Wm82.a2.v1 assembly. Conclusions. The information will facilitate the study of recombination hot spots in the soybean genome, identification of genes or quantitative trait loci controlling yield, seed quality and resistance to biotic or abiotic stresses as well as other genetic or genomic research.

59 BASIC BIOLOGICAL SCIENCES↗

Assessment of the ParFlow–CLM CONUS 1.0 integrated hydrologic model: evaluation of hyper-resolution water balance components across the contiguous United States

Abstract. Recent advancements in computational efficiency and Earth system modeling have awarded hydrologists with increasingly high-resolution models of terrestrial hydrology, which are paramount to understanding and predicting complex fluxes of moisture and energy. Continental-scale hydrologic simulations are, in particular, of interest to the hydrologic community for numerous societal, scientific, and operational benefits. The coupled hydrology–land surface model ParFlow–CLM configured over the continental United States (PFCONUS) has been employed in previous literature to study scale-dependent connections between water table depth, topography, recharge, and evapotranspiration, as well as to explore impacts of anthropogenic aquifer depletion to the water and energy balance. These studies have allowed for an unprecedented process-based understanding of the continental water cycle at high resolution. Here, we provide the most comprehensive evaluation of PFCONUS version 1.0 (PFCONUSv1) performance to date by comparing numerous modeled water balance components with thousands of in situ observations and several remote sensing products and using a range of statistical performance metrics for evaluation. PFCONUSv1 comparisons with these datasets are a promising indicator of model fidelity and ability to reproduce the continental-scale water balance at high resolution. Areas for improvement are identified, such as a positive streamflow bias at gauges in the eastern Great Plains, a shallow water table bias over many areas of the model domain, and low bias in seasonal total water storage amplitude, especially for the Ohio, Missouri, and Arkansas River basins. We discuss several potential sources for model bias and suggest that minimizing error in topographic processing and meteorological forcing would considerably improve model performance. Results here provide a benchmark and guidance for further PFCONUS model development, and they highlight the importance of concurrently evaluating all hydrologic components and fluxes to provide a multivariate, holistic validation of the complete modeled water balance.

O'Neill, Mary M. F. (ORCID:0000000221455165)↗

Motorized manipulator for positioning a TEM specimen

The invention relates to a motorized manipulator for positioning a TEM specimen holder with sub-micron resolution parallel to a y-z plane and rotating the specimen holder in the y-z plane, the manipulator comprising a base (2), and attachment means (30) for attaching the specimen holder to the manipulator, characterized in that the manipulator further comprises at least three nano-actuators (3.sup.a, 3.sup.b, 3.sup.c) mounted on the base, each nano-actuator showing a tip (4.sup.a, 4.sup.b, 4.sup.c), the at least three tips defining the y-z plane, each tip capable of moving with respect to the base in the y-z plane; a platform (5) in contact with the tips of the nano-actuators; and clamping means (6) for pressing the platform against the tips of the nano-actuators; as a result of which the nano-actuators can rotate the platform with respect to the base in the y-z plane and translate the platform parallel to the y-z plane.

Schmid, Andreas Karl↗

Neutron and X-ray analysis of the Fenna–Matthews–Olson photosynthetic antenna complex from Prosthecochloris aestuarii

The Fenna–Matthews–Olson protein from Prosthecochloris aestuarii ( Pa FMO) has been crystallized in a new form that is amenable to high-resolution X-ray and neutron analysis. The crystals belonged to space group H 3, with unit-cell parameters a = b = 83.64, c = 294.78 Å, and diffracted X-rays to ∼1.7 Å resolution at room temperature. Large Pa FMO crystals grown to volumes of 0.3–0.5 mm 3 diffracted neutrons to 2.2 Å resolution on the MaNDi neutron diffractometer at the Spallation Neutron Source. The resolution of the neutron data will allow direct determination of the positions of H atoms in the structure, which are believed to be fundamentally important in tuning the individual excitation energies of bacteriochlorophylls in this archetypal photosynthetic antenna complex. This is one of the largest unit-cell systems yet studied using neutron diffraction, and will allow the first high-resolution neutron analysis of a photosynthetic antenna complex.

solar (fuels), photosynthesis (natural and artific↗