Effects of interstage diffuser flow distortion on the performance of a 15.41-centimeter tip diameter axial power turbine

The performance of a variable-area stator, axial flow power turbine was determined in a cold-air component research rig for two inlet duct configurations. The two ducts were an interstage diffuser duct and an accelerated-flow inlet duct which produced stator inlet boundary layer flow blockages of 11 percent and 3 percent, respectively. Turbine blade total efficiency at design point was measured to be 5.3 percent greater with the accelerated-flow inlet duct installed due to the reduction in inlet blockage. Blade component measurements show that of this performance improvement, 35 percent occurred in the stator and 65 percent occurred in the rotor. Analysis of inlet duct internal flow using an Axisymmetric Diffuser Duct Code (ADD Code) were in substantial agreement with the test data.

Mclallin, K. L.↗

Effects of interstage diffuser flow distortion on the performance of a 15.41-centimeter tip diameter axial power turbine

The performance of a variable-area stator, axial flow power turbine was determined in a cold-air component research rig for two inlet duct configurations. The two ducts were an interstage diffuser duct and an accelerated-flow inlet duct which produced stator inlet boundary layer flow blockages of 11 percent and 3 percent, respectively. Turbine blade total efficiency at design point was measured to be 5.3 percent greater with the accelerated-flow inlet duct installed due to the reduction in inlet blockage. Blade component measurements show that of this performance improvement, 35 percent occurred in the stator and 65 percent occurred in the rotor. Analysis of inlet duct internal flow using an Axisymmetric Diffuser Duct Code (ADD Code) were in substantial agreement with the test data.

Mclallin, K. L.↗

MSL MMRTG Power Modeling for Lifetime Performance Predictions

The Multi-Mission Radioisotope Thermoelectric Generator (MMRTG) has been providing power to the Mars Science Laboratory (MSL) rover, Curiosity, for surface operations since 2012. The Jet Propulsion Laboratory (JPL) has employed the Life Performance Prediction Model (LPPM) to generate predictions and outputs based upon flight data from the rover and experimental data from the thermoelectric (TE) couples. In order to make these predictions, LPPM requires various spacecraft inputs relevant to RTG performance such as fin root temperature, load voltage, general purpose heat source (GPHS) inventory, etc., combined with couple data such as thermoelectric properties, interface degradation, and sublimation properties. With tens of thousands of hours of flight data to date, LPPM can not only track performance to date, but also make predictions on the power output of the MMRTG through the 17-year end-of-design-life (EODL). These predictions are useful for mission planners and surface operators who rely on the MMRTG for power in order to perform the critical science necessary during the mission. This paper will showcase the power data extracted from the flight electronics, comparing it to the predictions and outputs generated from LPPM.

Pinkowski, Stanley↗

Accelerating the Gauss-Seidel Power Flow Solver on a High Performance Reconfigurable Computer

The computationally intensive power flow problem determines the voltage magnitude and phase angle at each bus in a power system for hundreds of thousands of buses under balanced three-phase steady-state conditions. We report an FPGA acceleration of the Gauss-Seidel based power flow solver employed in the transmission module of the GridLAB-D power distribution simulator and analysis tool. The prototype hardware is implemented on an SGI Altix-RASC system equipped with a Xilinx Virtex II 6000 FPGA. Due to capacity limitations of the FPGA, only the bus voltage calculations of the power network are implemented on hardware while the branch current calculations are implemented in software. For a 200,000 bus system, the bus voltage calculation on the FPGA achieves a 48x speed-up with PQ buses and a 62 times for PV over an equivalent sequential software implementation. The average overall speed up of the FPGA-CPU implementation with 100 iterations of the Gauss-Seidel power solver is 2.6x over a software implementation, with the branch calculations on the CPU accounting for 85% of the total execution time. The FPGA-CPU implementation also shows linear scaling with increase in the size of the input power network.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Microwave system performance for a solar power satellite during startup/shutdown operations

The paper investigates the system performance and antenna characteristics under startup/shutdown conditions for the high power beam from a solar power satellite. Attention is given to the present microwave system reference configuration together with the dc power distribution system in the solar array and in the antenna. The pattern characteristics for the main beam, sidelobes, and grating lobes are examined for eight types of energizing configurations which include: random sequences, two types of concentric circles, and three types of line strips. In conclusion, it is noted that a proper choice of sequences should not cause environmental problems due to increased microwave radiation levels during the short time periods of energizing and de-energizing the antenna.

Arndt, G. D.↗

A technique for determining powered-lift STOL aircraft performance at sea level from flight data taken at altitude

State-of-the-technology powered-lift STOL aircraft can develop very high lift coefficients. The determination of how this high lift capability can be utilized for landing approaches is accomplished by evaluating aircraft velocity versus flightpath performance. This paper briefly discusses upper-surface-blowing power-lift technology and some of the significant features of the velocity versus flightpath plot that are used in evaluating the performance of powered-lift aircraft. A procedure for deriving the velocity versus flightpath plot for a powered-lift aircraft at any specified weight at sea level, based on flight-test data obtained at various weights and altitudes, is discussed in detail. Actual flight-test data obtained with NASA's Quiet Short-Haul Research Aircraft (QSRA) are used to illustrate this procedure and to evaluate the results.

Stevens, V. C.↗

Report on Performance of Prototype Dynatronix Power Supplies Developed Under a Phase I DOE SBIR

The purpose of this study is to evaluate the prototype power supplies fabricated by Dynatronix, Inc. This project supports the advancement of electroforming capabilities to produce ultra-high purity copper. Ultra-high purity copper is an essential material used for a range of current and future fundamental nuclear physics programs such as the MAJORANA DEMONSTRATOR. The Mach 30 power supplies are a new design built to the specifications from the requirements of Pacific Northwest National Laboratory (PNNL) with regard to timing, voltage, current output, and the required tolerances. The parameters used in these tests were developed empirically over a number of years based on a combination of thermodynamic and kinetics of the electroplating process. The power supplies were operated in a typical cleanroom environment for the production electroforming at PNNL. The units that were received by PNNL in July, 2010 have performed satisfactorily and have demonstrated short term durability.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Influence of the air-cooled supercritical carbon dioxide recompression cycle design-point on molten salt power tower techno-economic performance

Here, this paper investigates the techno-economic performance of a molten salt power tower integrated with an air-cooled supercritical carbon dioxide recompression cycle. Prior research into the cycle design point showed trade-offs between efficiency, cost, and temperature difference across the heat input, resulting in trade-offs between the design-point generation of the molten salt power tower system and the cost of sensible-heat thermal energy storage. Prior research into cycle off-design showed that colder ambient temperature designs have higher efficiencies on cold days but lower efficiency and capacity degradation on hot days. We present a framework to evaluate how cycle design, cost, and corresponding off-design performance affect the techno-economic performance of the molten salt power tower system. We use a steady-state off-design cycle model assuming fixed shaft speeds, inventory control, and air-cooler fan power control and integrate the cycle model with the molten salt power tower model from the National Renewable Energy Laboratory's System Advisor Model. First, we present a surrogate model that uses a heuristic approach to correct the interpolation when the cycle reaches capacity limitations at ambient temperatures hotter than design. Next, we evaluate how the recompression cycle design-point ambient temperature, air-cooler approach temperature, air-cooler fan power, and recuperator conductance influence cycle and system design metrics. Finally, we complete annual simulations using an hourly "duck curve" pricing schedule and present annual performance metrics to evaluate the cumulative effects of the cycle design parameters and corresponding off-design performance on molten salt power tower techno-economics.

14 SOLAR ENERGY↗

Alkali Metal Thermoelectric Conversion (AMTEC) for space nuclear power systems

Performance parameters of the Alkali Metal Thermoelectric Converter (AMTEC) for a 100 kW electric power system have been calculated at four technological levels assuming a heat pipe-cooled nuclear reactor heat source. The most advanced level considered would operate between 1180 K converter temperature and 711 K radiator temperature at 16 percent efficiency, and would weigh 1850 kg with a radiator area of 43 sq m. In addition, electrode research studies for the AMTEC systems have been conducted utilizing an experimental test cell of Bankston et al. (1983) and Mo and several Mo-Ti electrodes. It was found that the Mo-Ti electrodes offered no improvement in lifetime characteristics over the pure Mo electrodes, however, oxygen treatment of a degraded Mo electrode restored its specific power output to 90 percent of its original specific power and maintained this level for 60 hr, thus offering a potential for lifetime stability.

Bankston, C. P.↗

Power/energy use cases for high performance computing

Power and Energy have been identified as a first order challenge for future extreme scale high performance computing (HPC) systems. In practice the breakthroughs will need to be provided by the hardware vendors. But to make the best use of the solutions in an HPC environment, it will likely require periodic tuning by facility operators and software components. This document describes the actions and interactions needed to maximize power resources. It strives to cover the entire operational space in which an HPC system occupies. The descriptions are presented as formal use cases, as documented in the Unified Modeling Language Specification [1]. The document is intended to provide a common understanding to the HPC community of the necessary management and control capabilities. Assuming a common understanding can be achieved, the next step will be to develop a set of Application Programing Interfaces (APIs) to which hardware vendors and software developers could utilize to steer power consumption.

97 MATHEMATICS AND COMPUTING↗

Impact of Dry Cooler Air-Side Performance on a sCO2 Power Cycle for a CSP Application

Uncertainty around the design and control of the supercritical CO2 power cycle must be reduced before this technology can be implemented for large-scale grid support. To better understand the day-to-day performance of an sCO2 cycle, off-design performance calculations must be included for all power block components, and performance assumptions must be removed. This study has expanded the modeled scope to include the air-side performance for the dry cooler and has incorporated discretized heat transfer calculations for both streams through the pre-cooler to better predict off-design performance. This study considered a recompression Brayton cycle in a concentrating solar power application. The cycle model utilized fixed sCO2 turbomachinery maps for the main compressor, recompressor, and expander operating to supply approximately 10 MW gross at the design point. Fixed vendor-supplied fan curves were used to calculate the air-side performance of the dry cooler. The primary heater was modeled considering both the sCO2 and heat transfer fluid streams. Off-design performance was predicted for an ambient temperature range of 0-55℃, a HTF temperature range of 705-735℃, and a HTF mass flow range of 50-105% of the design point value. To understand the importance of modeling the air-side performance, the cycle off-design performance was also calculated using a constant CO2 outlet temperature assumption and a constant approach temperature assumption for the dry cooler. Results show that using these assumptions can significantly alter the power output and cycle efficiency predictions.

14 SOLAR ENERGY↗

Lifetime Cost and Performance model for photovoltaic power systems

This paper describes the approach and procedures of the Lifetime Cost and Performance (LCP) model for photovoltaic power systems. The LCP model is designed to evaluate the impact of alternative initial design and recurrent policy decisions on both cost and power output over the lifetime of a photovoltaic power plant. LCP is, therefore, useful to system designers and operators for addressing questions relating to optimal system configuration, installation activities, level of effort and timing of operations/maintenance actions, allowable degradation and replacement options.

Borden, C. S.↗

Long-Term Effects of Power Quality and Power Cycling on Thermoelectric Module Performance

Thermoelectric (TE) modules used in a heat pumping mode are increasingly being used for various applications involving heating and cooling. As their use becomes more prevalent and extends to lower cost applications using inexpensive commodity power supplies, it is important to characterize the long-term effects of power cycling and power quality on their performance. Two power supplies were evaluated with different levels of periodic and random deviations (PARD) from ideal DC power. This paper presents the results of an accelerated aging experimental study on intermittent power cycling of TE modules over the span of 5 actual months with each power supply. TE performance metrics that were monitored at specific time intervals are the AC resistance and figure of merit. The applied voltage, power consumption, TE hot and cold side temperatures and air temperatures were continuously measured. The experimental results indicate that the low-quality power supply quality had only a minor influence on properties and integrity of the TE modules, and is suitable for applications requiring intermittent use without a substantial reduction in performance.

Patel, Viral↗

Marine Hydrokinetic Turbine Power-Take-Off Design for Optimal Performance and Low Impact on Cost-of-Energy: Preprint

Marine hydrokinetic devices are becoming a popular method for generating marine renewable energy worldwide. These devices generate electricity by converting the kinetic energy of moving water, wave motion or currents, into electrical energy through the use of a power-take-off (PTO) system. Most PTO systems incorporate a mechanical or hydraulic drivetrain, power generator, and electric control/conditioning system to deliver the generated electric power to the grid at the required state. Like wind turbine applications, the PTO system must be designed for high reliability, good efficiency, and long service life with reasonable maintenance requirements, low cost, and an appropriate mechanical design for anticipated applied steady and unsteady loads. The ultimate goal of a PTO design is high efficiency and low maintenance and cost, with a low impact on the device cost-of-energy (CoE).

16 TIDAL AND WAVE POWER↗

Exploring Machine Learning Techniques For Dynamic Modeling on Future Exascale Systems

Future exascale systems must be optimized for both power and performance at scale in order to achieve DOE’s goal of a sustained petaflop within 20 Megawatts by 2022 [1]. Massive parallelism of the future systems combined with complex memory hierarchies will form a barrier to efficient application and architecture design. These challenges are exacerbated with emerging complex architectures such as GPGPUs and Intel Xeon Phi as parallelism increases orders of magnitude and system power consumption can easily triple or quadruple. Therefore, we need techniques that can reduce the search space for optimization, isolate power-performance bottlenecks, identify root causes for software/hardware inefficiency, and effectively direct runtime scheduling.

Song, Shuaiwen↗