Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power system reliability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Integration of Large-Scale Renewable Energy in the Bulk Power System: Lessons from International Experiences

Deployment of increasing amounts of renewable energy (RE) presents certain challenges in reliably integrating larger quantities RE into existing bulk power system infrastructures. RE Bulk power typically refers to large-scale power generation at a centralized facility and in the context of RE can include wind farms, utility-scale solar, geothermal, hydro and biomass facilities. Based on international experiences, several actions and related good practices have emerged to support the deployment of RE in the bulk power system. This paper provides a review of emerging international best practices that support the integration of large-scale RE; examples of country-level efforts in implementing these practices; and key considerations for any country pursuing bulk power sector transformation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Isotope Brayton electric power system for the 500 to 2500 watt range

An extensive study was conducted at the Lewis Research Center to evaluate an isotope Brayton electric power system for use in the 500 to 2500 W power range. Overall system simplicity was emphasized in order to reduce parasitic power losses and improve system reliability. Detailed parametric cycle analysis, conceptual component designs, and evaluation of system packaging were included. A single-loop system (gas) with six major components including one rotating unit was selected. Calculated net system efficiency varies from 23 to 28 percent over the power range.

Macosko, R. P.↗

Multi-Timescale Integrated Dynamics and Scheduling for Solar (MIDAS-Solar) (Final Technical Report)

Solar photovoltaic (PV) installations have experienced unprecedented growth in the United States. PV will become not only an energy producer but also a necessary provider of ancillary services at multiple timescales. Conventional methods to simulate power systems operations - such as long-term production simulation (which typically considers schedules from hours to minutes by using an optimization framework) and short-term transient studies (which simulate dynamics from seconds to sub-seconds using state variables and differential equations) - are not sufficient for studying the multiple-timescale variation of solar generation and its impact on system reliability. Long-term system economics and short-term system dynamics are highly coupled, particularly when the penetration level of renewable generation is extremely high, because the uncertainty and variability of solar generation will impact both power system steady-state and dynamic performance. This project helps meet and exceed the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Solar Energy Technologies Office goal of systems integration by directly addressing this stability and reliability challenge for power grid planning and operation. We have developed a temporally comprehensive, closed-loop simulation model, named Multi-timescale Integrated Dynamics and Scheduling (MIDAS), that seamlessly simulates power system operations from economic scheduling (day-ahead to hours) to dynamic response analysis (seconds to sub-seconds). For schedules with very high levels of inverter-based resources (IBRs), up to and including 100%, the stability of grid controls has been evaluated through electromagnetic transient (EMT) simulations and power-hardware-in-the-loop (PHIL) simulations of key transient events at key schedule points. Specifically, MIDAS provides: 1) a closed-loop simulation framework for simulating timescales from economic scheduling to dynamic stability analysis; 2) machine learning-based stability assessment; 3) EMT modeling and analysis for large-scale power systems; 4) MIDAS PHIL test bed. We worked with Hawaii Electric Companies to apply the MIDAS study framework to a Maui grid study. The entire island's transmission system was modeled in detail - from a yearly scheduling model, to a second-level frequency dynamic model, down to a sub-second-scale EMT model to address critical stability issues. The project demonstrated how MIDAS can help system planners and operators assess system reliability and stability while the power grid is marching toward a high-renewable, high-IBR future. In this Maui grid study, we found that 100% instantaneous IBR operation is achievable in EMT simulation and PHIL testing, and grid planners and operators might need new analysis/simulation tools to assess grid reliability and stability in the scheduling stage. MIDAS will bring Maui and other systems closer to 100% clean and stable energy futures. (In this study, we examined transient stability. Other topics necessary for 100% IBR operation, such as protection and resource adequacy, were not examined.)

100% Renewables↗

Integration of energy storage with diesel generation in remote communities

Highlights Battery energy storage may improve energy efficiency and reliability of hybrid energy systems composed by diesel and solar photovoltaic power generators serving isolated communities. In projects aiming update of power plants serving electrically isolated communities with redundant diesel generation, battery energy storage can improve overall economic performance of power supply system by reducing fuel usage, decreasing capital costs by replacing redundant diesel generation units, and increasing generator system life by shortening yearly runtime. Fast-acting battery energy storage systems with grid-forming inverters might have potential for improving drastically the reliability indices of isolated communities currently supplied by diesel generation. Abstract This paper will highlight unique challenges and opportunities with regard to energy storage utilization in remote, self-sustaining communities. The energy management of such areas has unique concerns. Diesel generation is often the go-to power source in these scenarios, but these systems are not devoid of issues. Without dedicated maintenance crews as in large, interconnected network areas, minor interruptions can be frequent and invasive not only for those who lose power, but also for those in the community that must then correct any faults. Although the immediate financial benefits are perhaps not readily apparent, energy storage could be used to address concerns related to reliability, automation, fuel supply concerns, generator degradation, solar utilization, and, yes, fuel costs to name a few. These ideas are shown through a case study of the Levelock Village of Alaska. Currently, the community is faced with high diesel prices and a difficult supply chain, which makes temporary loss of power very common and reductions in fuel consumption very impactful. This study will investigate the benefits that an energy storage system could bring to the overall system life, fuel costs, and reliability of the power supply. The variable efficiency of the generators, impact of startup/shutdown process, and low-load operation concerns are considered. The technological benefits of the combined system will be explored for various scenarios of future diesel prices and technology maintenance/replacement costs as well as for the avoidance of power interruptions that are so common in the community currently. Graphic abstract Discussion In several cases, energy storage can provide a means to promote energy equity by improving remote communities’ power supply reliability to levels closer to what the average urban consumer experiences at a reduced cost compared to transmission buildout. Furthermore, energy equity represents a hard-to-quantify benefit achieved by the integration of energy storage to isolated power systems of under-served communities, which suggests that the financial aspects of such projects should be questioned as the main performance criterion. To improve battery energy storage system valuation for diesel-based power systems, integration analysis must be holistic and go beyond fuel savings to capture every value stream possible.

25 ENERGY STORAGE↗

Metrics for the National SCADA Test Bed Program

The U.S. Department of Energy Office of Electricity Delivery and Energy Reliability (DOE-OE) National SCADA Test Bed (NSTB) Program is providing valuable inputs into the electric industry by performing topical research and development (R&D) to secure next generation and legacy control systems. In addition, the program conducts vulnerability and risk analysis, develops tools, and performs industry liaison, outreach and awareness activities. These activities will enhance the secure and reliable delivery of energy for the United States. This report will describe metrics that could be utilized to provide feedback to help enhance the effectiveness of the NSTB Program.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Options for Resilient and Flexible Power Systems in Select South American Economies

This presentation provides highlights from the published report NREL/TP-6A50-75431, which summarizes opportunities for Argentina, Brazil, Chile and Colombia to adapt to the new forces buffeting electricity sectors around the globe to ensure reliable, affordable, sustainable and resilient power systems. Special attention is placed on the potential role for natural gas to help ensure flexible and resilient power.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Power System Dynamic State Estimation: Motivations, Definitions, Methodologies and Future Work

This paper summarizes the technical activities of the Task Force on Power System Dynamic State and Parameter Estimation. This Task Force was established by the IEEE Working Group on State Estimation Algorithms to investigate the added benefits of dynamic state and parameter estimation for the enhancement of the reliability, security, and resilience of electric power systems. The motivations and engineering values of dynamic state estimation (DSE) are discussed in detail. Then, a set of potential applications that will rely on DSE is presented and discussed. Furthermore, a unified framework is proposed to clarify the important concepts related to DSE, forecasting-aided state estimation, tracking state estimation and static state estimation. An overview of the current progress in DSE and dynamic parameter estimation is provided. The paper also provides future research needs and directions for the power engineering community.

task force, dynamic state estimation, Parameter Es↗

Isotope Brayton electric power system for the 500 to 2500 watt range.

An extensive study was conducted at the Lewis Research Center to evaluate an isotope Brayton electric power system for use in the 500 to 2500 W power range. The study emphasized overall system simplicity in order to reduce parasitic power losses and improve system reliability. The study included detailed parametric cycle analysis, conceptual component designs, and evaluation of system packaging. The study has resulted in the selection of a single-loop system (gas) with six major components including one rotating unit. Calculated net system efficiency varies from 23 to 28% over the power range. The use of the Pu-238 heat source being developed for the Multi-Hundred-Watt Radioisotope Thermoelectric Generator program was assumed.

Macosko, R. P.↗

Energy Systems Integration: Data Call -- Become a Data Partner

This project aims to advance the understanding of costs associated with integrating PV onto the electric power distribution system while maintaining reliable grid operations. We have developed a bottom-up framework for calculating these costs as a function of PV penetration levels on specific feeders. This framework will used to inform and improve utility planning decisions, increase the transparency and speed associated with the interconnection process, and provide policymakers with more information on the total cost of energy from PV.

14 SOLAR ENERGY↗

Solar vs. Fission Surface Power for Mars

A multi-discipline team of experts from the National Aeronautics and Space Administration (NASA) developed Mars surface power system point design solutions for two conceptual missions. The primary goal of this study was to compare the relative merits of solar- versus fission-powered versions of each surface mission. First, the team compared three different solar power options against a fission power system concept for a sub-scale, uncrewed demonstration mission. The 4.5 meter (m) diameter pathfinder lander's primary mission would be to demonstrate Mars entry, descent, and landing techniques. Once on the Martian surface, the lander's In Situ Resource Utilization (ISRU) payload would demonstrate liquid oxygen propellant production using atmospheric resources. For the purpose of this exercise, location was assumed to be at the Martian equator. The three solar concepts considered included a system that only operated during daylight hours (at roughly half the daily propellant production rate of a round-the-clock fission design), a battery-augmented system that operated through the night (matching the fission concept's propellant production rate), and a system that operated only during daylight, but at a higher rate (again, matching the fission concept's propellant production rate). Including 30% mass growth allowance, total payload masses for the three solar concepts ranged from 1,116 to 2,396 kg, versus the 2,686 kg fission power scheme. However, solar power masses are expected to approach or exceed the fission payload mass at landing sites further from the equator, making landing site selection a key driver in the final power system decision. The team also noted that detailed reliability analysis should be performed on daytime-only solar power schemes to assess potential issues with frequent ISRU system on/off cycling. Next, the team developed a solar-powered point design solution for a conceptual four-crew, 500-day surface mission consisting of up to four landers per crewed expedition mission. Unlike the demonstration mission, a lengthy power outage due to the global dust storms that are known to occur on Mars would pose a safety hazard to a crewed mission. A similar fission versus solar power trade study performed by NASA in 2007 concluded that fission power was more reliable-with a much lower mass penalty-than solar power for this application. However, recent advances in solar cell and energy storage technologies and changes in operational assumptions prompted NASA to revisit the analysis. For the purpose of this exercise a particular landing site at Jezero Crater, located at 18o north latitude, was assumed. A fission power system consisting of four each 10 kW Kilopower fission reactors was compared to a distributed network of Orion-derived Ultraflex solar arrays and Lithium ion batteries mounted on every lander. The team found that a solar power system mass of about 9,800 kg would provide the 22 kilowatts (kW) keep-alive power needed to survive a dust storm lasting up to 120-days at average optical depth of 5, and 35 kW peak power for normal operations under clear skies. Although this is less than half the mass estimated during the 2007 work (which assumed latitudes up to 30o) it is still more than the 7,000 kg mass of the fission system which provides full power regardless of dust storm conditions.

Rucker, Michelle A.↗

Model-Based Approaches to Generate Knowledge from Data in a Plant Reliability Context

One challenge that nuclear power plant system engineers are facing is that the amount of equipment reliability (ER) data being continuously generated are extremely large. These data elements come in different forms: textual (e.g., condition reports) and numeric (e.g., generated by monitoring systems) and they provide system engineers with valuable insights and information regarding the discovery of anomalous behaviors or degradation trends, the identification of the possible causes behind such behaviors and trends, and the prediction of their direct consequences. This paper directly targets the generation of knowledge from ER data by putting “data into context”. Here, we employ model-based system engineering (MBSE) models of systems and assets to represent and capture their architecture and functional (i.e., cause-effect) relations. ER data elements are processed by identifying first which elements of the developed MBSE elements they are referring to. This task is much harder for textual data since the information contained in issue or maintenance reports needs to “be understood” by a computational tool. Here we called this process “knowledge extraction” where our methods to extract knowledge from textual data. Lastly, once numeric and textual ER data elements have been processed and “understood”, we discover possible cause-effect relations among them. This is performed by observing if a logical connection through the MBSE models exists, and if there is a temporal relation among them. The logic and temporal are the two main ingredients to perform “machine reasoning” from ER data.

97 MATHEMATICS AND COMPUTING↗

Options for Resilient and Flexible Power Systems in Select South American Economies

This presentation provides highlights from the published report TP-6A50-75431, which summarizes opportunities for Argentina, Brazil, Chile and Colombia to adapt to the new forces buffeting electricity sectors around the globe to ensure reliable, affordable, sustainable and resilient power systems. Special attention is placed on the potential role for natural gas to help ensure flexible and resilient power systems in those countries.

ENERGY PLANNING, POLICY, AND ECONOMY,HYDRO ENERGY,↗

The Need for Intelligent Control of Space Power Systems

As manned spacecraft venture farther from Earth, the need for reliable, autonomous control of vehicle subsystems becomes critical. This is particularly true for the electrical power system which is critical to every other system. Autonomy can not be achieved by simple scripting techniques due to the communication latency times and the difficulty associated with failures (or combinations of failures) that need to be handled in as graceful a manner as possible to ensure system availability. Therefore an intelligent control system must be developed that can respond to disturbances and failures in a robust manner and ensure that critical system loads are served and all system constraints are respected.

May, Ryan David↗

Data Mining and Machine Learning for Power System Monitoring, Understanding, and Impact Evaluation

This chapter presents results from the Big Data analysis framework to improve power system situational awareness and system reliability. For this purpose, a dataset with real-world phasor measurement unit data and historical transmission system outage data has been created and used to carry out the analysis. Several statistical analysis and machine learning methods have been developed and implemented for event and anomaly detection and modeling. Detection and analysis results for actual examples of power system events are presented. Finally, data-driven characterization and risk assessment methods for weather-related extremes in power systems are developed and demonstrated on the Bonneville Power Administration system. These applications demonstrate the capability of Machine Learning (ML) methods to monitor system abnormalities, to predict system events, and to characterize the impact of extreme events on power grid

data mining, power grid, machine learning, anomaly↗

Simulations of hybrid system varying solar radiation and microturbine response time

Hybrid power systems, such as combinations of renewable power sources with intermittent power production and non-renewable power sources, theoretically increase the reliability and thus integration of renewable sources in the electrical system. However, a recent increase in the number of hybrid installations has sparked interest in the effects of their connection to the grid, especially in remote areas. This paper analyses a photovoltaic-gas microturbine hybrid system dimensioned to be installed in La Paz (Mexico).The research presented in this paper studies and quantifies the effects on the total electric power produced, varying both the solar radiation and the gas microturbine response time. The gas microturbine and the photovoltaic panels are modelled using Matlab/Simulink software, obtaining a platform where different tests to simulate real conditions have been executed. They consist of diverse ramps of irradiance that replicate solar radiation variations, and different microturbine response times reproduced by the time constants of a first order transfer function that models the microturbine dynamic response. The results obtained show that when radiation varies quickly it does not produce significant differences in the power guarantee or the microturbine gas consumption, to any microturbine response time. However, these two parameters are highly variable with smooth radiance variations. The maximum total power variation decreases greatly as the radiation variation gets lower. In addition, by decreasing the microturbine response time, it is possible to appreciably increase the power guarantee although the maximum power variation and gas consumption increase. Only in cases of low radiation variation is there no appreciable difference in the maximum power variation obtained by the different turbine response times.

14 SOLAR ENERGY↗

Fault Contribution of Grid-Following and Grid-Forming Inverters Considering Generic Inverter Controls and Ride-through Requirements

Gradual transformation of the synchronous generator (SG)-dominated power systems to inverter-based resource (IBR)-dominated power systems is bringing new challenges regarding power system protection. Increasing IBR’s penetration will reduce the reliability of protection coordination, originally developed for SG-dominated power systems, potentially leading to less accurate calculation or even mis-operation. Thus, new protection schemes compatible with IBR-dominated power systems should be established. Prior to establishing the protection schemes, research on the fault contribution of generic IBR models should be conducted considering interconnection requirements. This paper conducts fault current contribution analysis of generic grid-following (GFL) and grid-forming (GFM) inverters considering interconnection requirements using an electromagnetic transient (EMT) simulation tool. To do this, EMT-based generic GFL models have been developed with the ride-through requirements from IEEE-1547 standards. In addition, the major functions of the generic models are explained. Then, the fault current analysis was conducted using GFL and GFM inverters in a single-inverter-infinite-bus system and a modified IEEE 34-node system considering different grid, fault, inverter control parameters.

Kim, Jinho [BATTELLE (PACIFIC NW LAB)]↗

Power system inertia estimation: Review of methods and the impacts of converter-interfaced generations

Understanding and quantifying the inertia of power systems with the integration of converter-interfaced generation (CIG) plays an essential role in the safe transition to a future low-inertia scenario. Here we provide a comprehensive summary of inertia definitions for both synchronous generators and CIGs as well as their corresponding estimation methods. In particular, the estimation methods are categorized as model-based and measurement-based approaches considering both small and large disturbances. The advantages and disadvantages of different methods are carefully discussed. This paper also offers for the first time a framework to quantify the virtual inertia of CIGs at the component and aggregation levels, an open problem in the literature. Finally, future directions for inertia estimation are identified and discussed. This significantly benefits the design of appropriate control and protection schemes in achieving a more reliable, secure, and resilient power system.

42 ENGINEERING↗

Options for Resilient and Flexible Power Systems in Select South American Economies

This document is the executive summary for the technical report titled 'Options for Resilient and Flexible Power Systems in Select South American Economies' that summarizes opportunities for Argentina, Brazil, Chile and Colombia to adapt to the new forces buffeting electricity sectors around the globe to ensure reliable, affordable, sustainable and resilient power systems. Special attention is placed on the potential role for natural gas to help ensure flexible and resilient power.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗