Search NASA⌕ Search

SEARCH · Search NASA

Results for “Project X”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

The Polarimeter for Relativistic Astrophysical X-ray Sources

The Polarimeter for Relativistic Astrophysical X-ray Sources (PRAXyS) is one of three Small Explorer (SMEX) missions selected by NASA for Phase A study, with a launch date in 2020. The PRAXyS Observatory exploits grazing incidence X-ray mirrors and Time Projection Chamber Polarimeters capable of measuring the linear polarization of cosmic X-ray sources in the 2-10 keV band. PRAXyS combines well-characterized instruments with spacecraft rotation to ensure low systematic errors. The PRAXyS payload is developed at the Goddard Space Flight Center with the Johns Hopkins University Applied Physics Laboratory, University of Iowa, and RIKEN (JAXA) collaborating on the Polarimeter Assembly. The LEOStar-2 spacecraft bus is developed by Orbital ATK, which also supplies the extendable optical bench that enables the Observatory to be compatible with a Pegasus class launch vehicle. A nine month primary mission will provide sensitive observations of multiple black hole and neutron star sources, where theory predicts polarization is a strong diagnostic, as well as exploratory observations of other high energy sources. The primary mission data will be released to the community rapidly and a Guest Observer extended mission will be vigorously proposed.

Small Explorer↗

LandCast 2030 High-Resolution Population Projection

The LandCast 2030 data set is an empirically-informed spatial distribution of projected population of the contiguous U.S. for 2030 compiled on a 30" x 30" latitute/longitude grid. Population projections of county level numbers were developed using a modified version of the U.S. Census's projection methodology - with the U.S. Census's official projection as the benchmark. Projected census counts were apportioned to each grid cell based on locally adaptive likelihood coefficients, which are based on land cover, slope, road proximity, distances to larger cities, a moving average of current population, and other data sets. The LandCast 2030 data set was developed as part of Oak Ridge National Laboratory (ORNL) Global Population Project for estimating ambient populations at risk.

Source record↗

LandCast 2050 High-Resolution Population Projection

The LandCast 2050 data set is an empirically-informed spatial distribution of projected population of the contiguous U.S. for 2050 compiled on a 30" x 30" latitude/longitude grid. Population projections of county level numbers were developed using a modified version of the U.S. Census's projection methodology - with the U.S. Census's official projection as the benchmark. Projected census counts were apportioned to each grid cell based on locally adaptive likelihood coefficients, which are based on land cover, slope, road proximity, distances to larger cities, a moving average of current population, and other data sets. The LandCast data set was developed as part of Oak Ridge National Laboratory (ORNL) Global Population Project for estimating ambient populations at risk.

Source record↗

Improvements in optical metrology for high-performance variable-line-spacing x-ray gratings

Here, we discuss a project to develop a precision metrology system for variable-line-spacing x-ray gratings using interferometric microscopes. We are developing test standards and calibration techniques to measure and correct for geometrical distortion and blur, and data processing techniques to combine multiple measurements and measure line spacing with high accuracy.

Calibration methods↗

Impact of a Vertically Polarized Undulator on LCLS Hard X-ray Experiments

The LCLS-II project will install two variable gap, horizontally polarized undulators into the LCLS undulator hall. One undulator is designed to produce soft x-rays spanning an energy range of 200-1250 eV (SXU) while the other is designed for the hard spectral range of 1-25 keV (HXU). The hard x-ray LCLS instruments (X-ray Pump- Probe [XPP], X-ray correlation Spectroscopy [XCS], Coherent X-ray Imaging [CXI], Matter in Extreme Conditions [MEC]) will be repurposed to operate on the HXU line while two new soft x-ray beamlines will be created for the SXU line. An alternate HXU undulator design is being considered that could provide advantages over the present design choice. In particular, the project team is collaborating with Argonne National Laboratory to develop a vertically polarized undulator (VPU). A 1-m prototype VPU device was successfully constructed this year and a full size prototype is in process. A decision to alter the project baseline, which is the construction of a horizontally polarized device, must be made in the coming weeks to not impact the present project schedule. Please note that a change to the soft x-ray undulator is not under discussion at the moment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hyperspectral X-ray Imaging: Progress Towards Chemical Analysis in the SEM

The Hyperspectral X-ray Imaging (HXI) project will enable non-destructive chemical-state determination of nano-scale samples in the electron microscope for nuclear safeguards applications. To efficiently measure chemical state through electron-excited X-ray emission requires a combination of wide spectral bandwidth, high resolution, and high count rate capability. We are building a next-generation X-ray detector based on an array of transition edge sensors (TESs) to make these measurements possible and routine in the scanning electron microscope (SEM). Leveraging the large pixel densities afforded by microwave multiplexing readout and continuous, uninterrupted operation of a cryogen-free dilution refrigerator, this instrument will have efficiency to allow chemical species identification of nano-scale samples in hours instead of days to weeks. We describe prototype pixel designs for this HXI instrument, comprising three pixel types that will make up the hybrid TES array. Engineering design of the integrated HXI cryostat and SEM system is in progress, with full detector commissioning expected in Spring 2021 followed closely by full-scale integration with the SEM. Furthermore, we also report on the commissioning of a complementary TES-based X-ray emission spectroscopy platform for bulk samples to build a spectral library for HXI sample identification.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Imaging X-Ray Polarimetry Explorer (IXPE) Risk Management

The Imaging X-ray Polarimetry Explorer (IXPE) project is an international collaboration to build and fly a polarization sensitive X-ray observatory. The IXPE Observatory consists of the spacecraft and payload. The payload is composed of three X-ray telescopes, each consisting of a mirror module optical assembly and a polarization-sensitive X-ray detector assembly; a deployable boom maintains the focal length between the optical assemblies and the detectors. The goal of the IXPE Mission is to provide new information about the origins of cosmic X-rays and their interactions with matter and gravity as they travel through space. IXPE will do this by exploiting its unique capability to measure the polarization of X-rays emitted by cosmic sources. The collaboration for IXPE involves national and international partners during design, fabrication, assembly, integration, test, and operations. The full collaboration includes NASA Marshall Space Flight Center (MSFC), Ball Aerospace, the Italian Space Agency (ASI), the Italian Institute of Astrophysics and Space Planetology (IAPS)/Italian National Institute of Astrophysics (INAF), the Italian National Institute for Nuclear Physics (INFN), the University of Colorado (CU) Laboratory for Atmospheric and Space Physics (LASP), Stanford University, McGill University, and the Massachusetts Institute of Technology. The goal of this paper is to discuss risk management as it applies to the IXPE project. The full IXPE Team participates in risk management providing both unique challenges and advantages for project risk management. Risk management is being employed in all phases of the IXPE Project, but is particularly important during planning and initial execution-the current phase of the IXPE Project. The discussion will address IXPE risk strategies and responsibilities, along with the IXPE management process which includes risk identification, risk assessment, risk response, and risk monitoring, control, and reporting.

IXPE↗

ASCA Observations

This recently expired grant has supported the work of the PI, his students, and his collaborators on a variety of ASCA projects over the past four years. Annual reports have summarized much of the work accomplished; here we provide a brief review of the work resulting from this effort, and a summary of the personnel who have benefited from the grant's support. Starburst Galaxies with Extreme X-ray Luminosities This project began as a careful examination of the claims of Boller et al. (1992) that there were dozens of "normal" galaxies in the ROSAT All-Sky Survey that had X-ray luminosities in excess of 1042 erg sec, higher than that seen in the hundreds of non-AGN galaxies observed with Einstein. If true, this suggested that X-ray emission associated with star formation activity might have a significant contribution to make to the still unexplained cosmic X-ray background (XRB). Since some of our earlier work with the Einstein Observatory Deep Surveys had suggested a similar possibility and several sets of authors over the years had modelled the starburst XRB contribution, these claims were worth pursuing. Our work expanded the examination beyond the RASS to include earlier claims of high-luminosity galaxies powered by starburst emission (selected in this case on the basis of the far-IR luminosities). The result of extensive followup observations under several programs using ROSAT, ASCA, and ground-based facilities was to show that nearly all of these objects in fact have hidden AGN at their cores, and that their luminosities are not in any way extraordinary.

Helfand, David J.↗

BRIGHTEST X-RAY CLUSTERS OF GALAXIES IN THE CFHTLS WIDE FIELDS: CATALOG AND OPTICAL MASS ESTIMATOR

The Canada-France-Hawaii Telescope Legacy Survey (CFHTLS) presents a unique data set for weak-lensing studies, having high-quality imaging and deep multiband photometry. We have initiated an XMM-CFHTLS project to provide X-ray observations of the brightest X-ray-selected clusters within the wide CFHTLS area. Performance of these observations and the high quality of CFHTLS data allow us to revisit the identification of X-ray sources, introducing automated reproducible algorithms, based on the multicolor red sequence finder. We have also introduced a new optical mass proxy. We provide the calibration of the red sequence observed in the Canada-France-Hawaii filters and compare the results with the traditional single-color red sequence and photo-z. We test the identification algorithm on the subset of highly significant XMM clusters and identify 100% of the sample. We find that the integrated z-band luminosity of the red sequence galaxies correlates well with the X-ray luminosity, with a surprisingly small scatter of 0.20 dex. We further use the multicolor red sequence to reduce spurious detections in the full XMM and ROSAT All-Sky Survey (RASS) data sets, resulting in catalogs of 196 and 32 clusters, respectively. We made spectroscopic follow-up observations of some of these systems with HECTOSPEC and in combination with BOSS DR9 data. We also describe the modifications needed to the source detection algorithm in order to maintain high purity of extended sources in the shallow X-ray data. We also present the scaling relation between X-ray luminosity and velocity dispersion.

79 ASTRONOMY AND ASTROPHYSICS↗

THE CHANDRA CARINA COMPLEX PROJECT: DECIPHERING THE ENIGMA OF CARINA'S DIFFUSE X-RAY EMISSION

We present a 1.42 deg{sup 2} mosaic of diffuse X-ray emission in the Great Nebula in Carina from the Chandra X-ray Observatory Advanced CCD Imaging Spectrometer camera. After removing >14,000 X-ray point sources from the field, we smooth the remaining unresolved emission, tessellate it into segments of similar apparent surface brightness, and perform X-ray spectral fitting on those tessellates to infer the intrinsic properties of the X-ray-emitting plasma. By modeling faint resolved point sources, we estimate the contribution to the extended X-ray emission from unresolved point sources and show that the vast majority of Carina's unresolved X-ray emission is truly diffuse. Line-like correlated residuals in the X-ray spectral fits suggest that substantial X-ray emission is generated by charge exchange at the interfaces between Carina's hot, rarefied plasma and its many cold neutral pillars, ridges, and clumps.

79 ASTRONOMY AND ASTROPHYSICS↗

A Burst Chasing X-ray Polarimeter

This viewgraph presentation reviews the rationale, design, and importance of an X-Ray Polarimeter. There is a brief discussion of Gamma Ray Bursts, followed by a review of the theories of Gamma-Ray Bursts Polarization. This leads to the question of "How do we measure the polarization?" and a discussion of the GRB x-ray emission, the photoelectric effect and photoelectric polarimetry. The requirements for the work, can only be approached using a gas detector. This leads to a discussion of a Micropattern Gas Polarimeter, and the Time-Projection Chamber (TPC) X-ray Polarimeter.

Hill, Joanne↗

3D Mapping of the Neutral X-Ray Absorption in the Local Interstellar Medium: The Gaia and XMM-Newton Synergy

We present a three-dimensional map of the hydrogen density distribution in the Galactic interstellar medium. The hydrogen-equivalent column densities were obtained from the Exploring the X-ray Transient and variable Sky project (EXTRAS) which provides equivalent NH values from X-ray spectral fits of observations within the XMM-Newton Data Release. EXTRAS include multiple fits for each source, allowing an accurate determination of the equivalent column densities, which depends on the continuum modelling of the spectra. A cross-correlation between the EXTRAS catalogue and the first Gaia Data Release was performed in order to obtain accurate parallax and distance measurements. We use a Bayesian method explained in Rezaei Kh. et al. (2017) in order to predict the most probable distribution of the density at any arbitrary point, even for lines of sight along which there are no initial observation. The resulting map shows small-scale density structures which could not have been modelled by using analytic density profiles. In this paper, we present a proof of concept of the kind of science possible with the synergy of these catalogues. However, given the systematic uncertainties connected to the source identification and to the dependence of NH on the spectral model, the present maps should be considered qualitatively at this point.

Gatuzz, Efrain↗

V. The X-15 flight research program in relation to the development of advanced military aircraft

The design, construction, and development of advanced military aircraft undoubtedly will involve the utilization of many relatively new concepts in several deafferent, but related, areas. In many cases, these new concepts will require new flight techniques or involve development problems inherent in the use of relatively unproven methods, materials, structures, systems, and configurations. Moreover, flight verification will be required of aircraft aerodynamics and flight behavior because of the usual uncertainties associated with predicted data. Solutions to these problems obviously would require flight testing involving extensive time and effort before the aircraft could become operationally acceptable. Upon the inception of the X-15 research airplane project, many new and far-reaching techniques and principles were studied and applied in the aircraft design and are currently being demonstrated and investigated. Because similar concepts are likely to be used in advanced military aircraft, the X-15 flight program will provide significant information, over a broad flight environment, pertinent to the development of these vehicles. This paper discusses the research objectives of the X-15 flight program, some of the flight aerodynamic characteristics currently being obtained, some development problems encountered, and the experience obtained with the advanced systems investigated.

Military aircraft↗

Description of a prototype emission-transmission computed tomography imaging system

We have developed a prototype imaging system that can perform simultaneous x-ray transmission CT and SPECT phantom studies. This system employs a 23-element high-purity-germanium detector array. The detector array is coupled to a collimator with septa angled toward the focal spot of an x-ray tube. During image acquisition, the x-ray fan beam and the detector array move synchronously along an arc pivoted at the x-ray source. Multiple projections are obtained by rotating the object, which is mounted at the center of rotation of the system. The detector array and electronics can count up to 10(6) cps/element with sufficient energy-resolution to discriminate between x-rays at 100-120 kVp and gamma rays from 99mTc. We have used this device to acquire x-ray CT and SPECT images of a three-dimensional Hoffman brain phantom. The emission and transmission images may be superimposed in order to localize the emission image on the transmission map.

NASA Discipline Musculoskeletal↗

Multi-Frame Gated X-Ray Imager Report

The Multi-Frame Gated X-ray Imager (MGXI) project for the Lawrence Livermore National Laboratory (LLNL) with Project Leader Arthur Carpenter has finished its third year of collaboration with PI Charles Hunt in the ECE Department at UC Davis. This Target Area Science Engineering (TASE) project is part of the National Ignition Facility (NIF) and receives federal funding from the Department of Energy under contract B639825 for the Vacuum Microelectronics (VME) Group to conduct the yearly objectives. The ultimate goal is to construct a burst-mode x-ray imager with multiple frames with as low as ≤25μm spatial resolution and 50ps temporal resolution for use with x-rays in the 5-75keV range; and when coupled to an optically sensitive transmission photocathode (such as an S20) 400-700nm visible range.

42 ENGINEERING↗

SU-E-T-452: Identifying Inefficiencies in Radiation Oncology Workflow and Prioritizing Solutions for Process Improvement and Patient Safety

Purpose: Successful radiation therapy requires multi-step processes susceptible to unnecessary delays that can negatively impact clinic workflow, patient satisfaction, and safety. This project applied process improvement tools to assess workflow bottlenecks and identify solutions to barriers for effective implementation. Methods: We utilized the DMAIC (define, measure, analyze, improve, control) methodology, limiting our scope to the treatment planning process. From May through December of 2014, times and dates of each step from simulation to treatment were recorded for 507 cases. A value-stream map created from this dataset directed our selection of outcome measures (Y metrics). Critical goals (X metrics) that would accomplish the Y metrics were identified. Barriers to actions were binned into control-impact matrices, in order to stratify them into four groups: in/out of control and high/low impact. Solutions to each barrier were then categorized into benefit-effort matries to identify those of high benefit and low effort. Results: For 507 cases, the mean time from simulation to treatment was 235 total hours. The mean process and wait time were 60 and 132 hours, respectively. The Y metric was to increase the ratio of all non-emergent plans completed the business day prior to treatment from 47% to 75%. Project X metrics included increasing the number of IMRT QAs completed at least 24 hours prior to treatment from 19% to 80% and the number of non-IMRT plans approved at least 24 hours prior to treatment from 33% to 80%. Intervals from simulation to target contour and from initial plan completion to plan approval were identified as periods that could benefit from intervention. Barriers to actions were binned into control-impact matrices and solutions by benefit-effort matrices. Conclusion: The DMAIC method can be successfully applied in radiation therapy clinics to identify inefficiencies and prioritize solutions for the highest impact.

60 APPLIED LIFE SCIENCES↗