At least 631 records · Page 35

Dose-Volume Metrics Associated With Radiation Pneumonitis After Stereotactic Body Radiation Therapy for Lung Cancer

Purpose: To identify dose-volume factors associated with radiation pneumonitis (RP) after stereotactic body radiation therapy (SBRT) for lung cancer. Methods and Materials: This study analyzed 74 patients who underwent SBRT for primary lung cancer. The prescribed dose for SBRT was uniformly 48 Gy in four fractions at the isocenter. RP was graded according to the Common Terminology Criteria for Adverse Events (CTCAE) v.3. Symptomatic RP was defined as grade 2 or worse. Optimal cut-offs dividing the patient population into two subgroups based on the incidence of symptomatic RP were sought using the following dose-volume metrics: PTV volume (ml), mean lung dose (Gy), and V5, V10, V15, V20, V25, V30, V35, and V40 (%) of both lungs excluding the PTV. Results: With a median follow-up duration of 31.4 months, symptomatic RP was observed in 15 patients (20.3%), including 1 patient with grade 3. Optimal cut-offs for pulmonary dose-volume metrics were V25 and V20. These two factors were highly correlated with each other, and V25 was more significant. Symptomatic RP was observed in 14.8% of the patients with V25 <4.2%, and the rate was 46.2% in the remainder (p = 0.019). PTV volume was another significant factor. The symptomatic RP rate was significantly lower in the group with PTV <37.7 ml compared with the larger PTV group (11.1% vs. 34.5%, p = 0.020). The patients were divided into three subgroups (patients with PTV <37.7 ml; patients with, PTV {>=}37.7 ml and V25 <4.2%; and patients with PTV {>=}37.7 ml and V25 {>=}4.2%); the incidence of RP grade 2 or worse was 11.1%, 23.5%, and 50.0%, respectively (p = 0.013). Conclusions: Lung V25 and PTV volume were significant factors associated with RP after SBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Value of [{sup 11}C]Methionine PET for Stereotactic Radiation Therapy With Intensity Modulated Radiation Therapy to Metastatic Brain Tumors

Purpose: This study investigated the clinical impact of {sup 11}C-labeled methionine-positron emission tomography (MET-PET) for stereotactic radiation therapy with intensity modulated radiation therapy (SRT-IMRT) in metastatic brain tumors. Methods and Materials: Forty-two metastatic brain tumors were examined. All tumors were treated with SRT-IMRT using a helical tomotherapy system. Gross tumor volume (GTV) was defined and drawn on the stereotactic magnetic resonance (MR) image, taking into account the respective contributions of MR imaging and MET-PET. Planning target volume (PTV) encompassed the GTV-PET plus a 2-mm margin. SRT-IMRT was performed, keeping the dose for PTV at 25-35 Gy in 5 fractions. The ratio of the mean value of MET uptake to the contralateral normal brain (L/N ratio) was plotted for the PTV prior to SRT-IMRT, at 3 months following SRT-IMRT, and at 6 months following SRT-IMRT. Tumor characteristic changes of MET uptake before and after SRT-IMRT were evaluated quantitatively, comparing them with MRI examination. Results: Mean {+-} SD L/N ratios were 1.95 {+-} 0.83, 1.18 {+-} 0.21, and 1.12 {+-} 0.25 in the pre-SRT-IMRT group, in the 3 months post-SRT-IMRT group, and in the 6 months post-SRT-IMRT group, respectively. Differences in the mean L/N ratio between the pre-SRT-IMRT group and the 3-month post-SRT-IMRT group and between the pre-SRT-IMRT group and the 6 month post-SRT-IMRT group were statistically significant, irrespective of MRI examination. Conclusions: We showed examples of metastatic lesions demonstrating significant decreases in MET uptake following SRT-IMRT. MET-PET seems to have a potential role in providing additional information, although MRI remains the gold standard for diagnosis and follow-up after SRT-IMRT. The present study is a preliminary approach, but to more clearly define the impact of PET-based radiosurgical assessment, further experimental and clinical analyses are required.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predictive Models for Regional Hepatic Function Based on 99mTc-IDA SPECT and Local Radiation Dose for Physiologic Adaptive Radiation Therapy

Purpose: High-dose radiation therapy (RT) for intrahepatic cancer is limited by the development of liver injury. This study investigated whether regional hepatic function assessed before and during the course of RT using 99mTc-labeled iminodiacetic acid (IDA) single photon emission computed tomography (SPECT) could predict regional liver function reserve after RT. Methods and Materials: Fourteen patients treated with RT for intrahepatic cancers underwent dynamic 99mTc-IDA SPECT scans before RT, during, and 1 month after completion of RT. Indocyanine green (ICG) tests, a measure of overall liver function, were performed within 1 day of each scan. Three-dimensional volumetric hepatic extraction fraction (HEF) images of the liver were estimated by deconvolution analysis. After coregistration of the CT/SPECT and the treatment planning CT, HEF dose–response functions during and after RT were generated. The volumetric mean of the HEFs in the whole liver was correlated with ICG clearance time. Three models, dose, priori, and adaptive models, were developed using multivariate linear regression to assess whether the regional HEFs measured before and during RT helped predict regional hepatic function after RT. Results: The mean of the volumetric liver HEFs was significantly correlated with ICG clearance half-life time (r=−0.80, P<.0001), for all time points. Linear correlations between local doses and regional HEFs 1 month after RT were significant in 12 patients. In the priori model, regional HEF after RT was predicted by the planned dose and regional HEF assessed before RT (R=0.71, P<.0001). In the adaptive model, regional HEF after RT was predicted by regional HEF reassessed during RT and the remaining planned local dose (R=0.83, P<.0001). Conclusions: 99mTc-IDA SPECT obtained during RT could be used to assess regional hepatic function and helped predict post-RT regional liver function reserve. This could support individualized adaptive radiation treatment strategies to maximize tumor control and minimize the risk of liver damage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prognostic Value of External Beam Radiation Therapy in Patients Treated With Surgical Resection and Intraoperative Electron Beam Radiation Therapy for Locally Recurrent Soft Tissue Sarcoma: A Multicentric Long-Term Outcome Analysis

Background: A joint analysis of data from centers involved in the Spanish Cooperative Initiative for Intraoperative Electron Radiotherapy was performed to investigate long-term outcomes of locally recurrent soft tissue sarcoma (LR-STS) patients treated with a multidisciplinary approach. Methods and Materials: Patients with a histologic diagnosis of LR-STS (extremity, 43%; trunk wall, 24%; retroperitoneum, 33%) and no distant metastases who underwent radical surgery and intraoperative electron radiation therapy (IOERT; median dose, 12.5 Gy) were considered eligible for participation in this study. In addition, 62% received external beam radiation therapy (EBRT; median dose, 50 Gy). Results: From 1986 to 2012, a total of 103 patients from 3 Spanish expert IOERT institutions were analyzed. With a median follow-up of 57 months (range, 2-311 months), 5-year local control (LC) was 60%. The 5-year IORT in-field control, disease-free survival (DFS), and overall survival were 73%, 43%, and 52%, respectively. In the multivariate analysis, no EBRT to treat the LR-STS (P=.02) and microscopically involved margin resection status (P=.04) retained significance in relation to LC. With regard to IORT in-field control, only not delivering EBRT to the LR-STS retained significance in the multivariate analysis (P=.03). Conclusion: This joint analysis revealed that surgical margin and EBRT affect LC but that, given the high risk of distant metastases, DFS remains modest. Intensified local treatment needs to be further tested in the context of more efficient concurrent, neoadjuvant, and adjuvant systemic therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Daily Sodium Butyrate Enema for the Prevention of Radiation Proctitis in Prostate Cancer Patients Undergoing Radical Radiation Therapy: Results of a Multicenter Randomized Placebo-Controlled Dose-Finding Phase 2 Study

Purpose: To evaluate the efficacy of sodium butyrate enemas (NABUREN) in prostate cancer radiation therapy (RT) in reducing the incidence, severity, and duration of acute RT-induced proctitis. Methods and Materials: 166 patients, randomly allocated to 1 of 4 groups (rectal sodium butyrate 1 g, 2 g, or 4 g daily or placebo), were treated with NABUREN during and 2 weeks after RT. The grade of proctitis was registered in a daily diary. The correlation between NABUREN and proctitis was investigated through χ{sup 2} statistics. The toxicity endpoints considered were as follows: total number of days with grade ≥1 proctitis (≥G1); total number of days with grade ≥2 proctitis (≥G2); ≥G1 and ≥G2 proctitis lasting at least 3 and 5 consecutive days starting from week 4 (≥G1+3d, ≥G2+3d); damaging effects of RT on rectal mucosa as measured by endoscopy. The relationship between endpoints and pretreatment morbidities, hormonal therapy, presence of diabetes or hypertension, abdominal surgery, or hemorrhoids was investigated by univariate analysis. Results: The patients were randomly allocated to the 4 arms. No difference in the distribution of comorbidities among the arms was observed (P>.09). The mean ≥G1 and ≥G2 proctitis were 7.8 and 4.9 for placebo and 8.9 and 4.7 for the NABUREN group, respectively. No favorable trend in reduction of incidence, severity, and duration of ≥G1 and ≥G2 proctitis was observed with NABUREN use. In univariate analysis, ≥G1+3d toxicity was found to be related to hemorrhoids (P=.008), and a slight correlation was found between ≥G2 proctitis and hormonal therapy (P=.06). The RT effects on rectal mucosa as based on endoscopic assessment were mainly related to diabetes (P<.01). Endoscopy data at 6 week showed no significant difference between the placebo and butyrate arms. The other investigated endpoints were not correlated with any of the clinical risk factors analyzed. Conclusion: There was no evidence of efficacy of NABUREN in reducing the incidence, severity, and duration of acute radiation proctitis. There was a correlation between some endpoints and clinical risk factors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Constituent Components of Out-of-Field Scatter Dose for 18-MV Intensity Modulated Radiation Therapy Versus 3-Dimensional Conformal Radiation Therapy: A Comparison With 6-MV and Implications for Carcinogenesis

Purpose: To characterize and compare the components of out-of-field dose for 18-MV intensity modulated radiation therapy (IMRT) versus 3-dimensional conformal radiation therapy (3D-CRT) and their 6-MV counterparts and consider implications for second cancer induction. Methods and Materials: Comparable plans for each technique/energy were delivered to a water phantom with a sloping wall; under full scatter conditions; with field edge abutting but outside the bath to prevent internal/phantom scatter; and with shielding below the linear accelerator head to attenuate head leakage. Neutron measurements were obtained from published studies. Results: Eighteen-megavolt IMRT produces 1.7 times more out-of-field scatter than 18-MV 3D-CRT. In absolute terms, however, differences are just approximately 0.1% of central axis dose. Eighteen-megavolt IMRT reduces internal/patient scatter by 13%, but collimator scatter (C) is 2.6 times greater than 18-MV 3D-CRT. Head leakage (L) is minimal. Increased out-of-field photon scatter from 18-MV IMRT carries out-of-field second cancer risks of approximately 0.2% over and above the 0.4% from 18-MV 3D-CRT. Greater photoneutron dose from 18-MV IMRT may result in further maximal, absolute increased risk to peripheral tissue of approximately 1.2% over 18-MV 3D-CRT. Out-of-field photon scatter remains comparable for the same modality irrespective of beam energy. Machine scatter (C+L) from 18 versus 6 MV is 1.2 times higher for IMRT and 1.8 times for 3D-CRT. It is 4 times higher for 6-MV IMRT versus 3D-CRT. Reduction in internal scatter with 18 MV versus 6 MV is 27% for 3D-CRT and 29% for IMRT. Compared with 6-MV 3D-CRT, 18-MV IMRT increases out-of-field second cancer risk by 0.2% from photons and adds 0.28-2.2% from neutrons. Conclusions: Out-of-field photon dose seems to be independent of beam energy for both techniques. Eighteen-megavolt IMRT increases out-of-field scatter 1.7-fold over 3D-CRT because of greater collimator scatter despite reducing internal/patient scatter. Out-of-field carcinogenic risk is thus increased (but improved in-field dose conformity may offset this). Potentially increased carcinogenic risk should be weighed against any benefit 18-MV IMRT may provide.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gastrointestinal Dose-Histogram Effects in the Context of Dose-Volume–Constrained Prostate Radiation Therapy: Analysis of Data From the RADAR Prostate Radiation Therapy Trial

Purpose: To use a high-quality multicenter trial dataset to determine dose-volume effects for gastrointestinal (GI) toxicity following radiation therapy for prostate carcinoma. Influential dose-volume histogram regions were to be determined as functions of dose, anatomical location, toxicity, and clinical endpoint. Methods and Materials: Planning datasets for 754 participants in the TROG 03.04 RADAR trial were available, with Late Effects of Normal Tissues (LENT) Subjective, Objective, Management, and Analytic (SOMA) toxicity assessment to a median of 72 months. A rank sum method was used to define dose-volume cut-points as near-continuous functions of dose to 3 GI anatomical regions, together with a comprehensive assessment of significance. Univariate and multivariate ordinal regression was used to assess the importance of cut-points at each dose. Results: Dose ranges providing significant cut-points tended to be consistent with those showing significant univariate regression odds-ratios (representing the probability of a unitary increase in toxicity grade per percent relative volume). Ranges of significant cut-points for rectal bleeding validated previously published results. Separation of the lower GI anatomy into complete anorectum, rectum, and anal canal showed the impact of mid-low doses to the anal canal on urgency and tenesmus, completeness of evacuation and stool frequency, and mid-high doses to the anorectum on bleeding and stool frequency. Derived multivariate models emphasized the importance of the high-dose region of the anorectum and rectum for rectal bleeding and mid- to low-dose regions for diarrhea and urgency and tenesmus, and low-to-mid doses to the anal canal for stool frequency, diarrhea, evacuation, and bleeding. Conclusions: Results confirm anatomical dependence of specific GI toxicities. They provide an atlas summarizing dose-histogram effects and derived constraints as functions of anatomical region, dose, toxicity, and endpoint for informing future radiation therapy planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Therapy Planning for Early-Stage Hodgkin Lymphoma: Experience of the International Lymphoma Radiation Oncology Group

Purpose: Early-stage Hodgkin lymphoma (HL) is a rare disease, and the location of lymphoma varies considerably between patients. Here, we evaluate the variability of radiation therapy (RT) plans among 5 International Lymphoma Radiation Oncology Group (ILROG) centers with regard to beam arrangements, planning parameters, and estimated doses to the critical organs at risk (OARs). Methods: Ten patients with stage I-II classic HL with masses of different sizes and locations were selected. On the basis of the clinical information, 5 ILROG centers were asked to create RT plans to a prescribed dose of 30.6 Gy. A postchemotherapy computed tomography scan with precontoured clinical target volume (CTV) and OARs was provided for each patient. The treatment technique and planning methods were chosen according to each center's best practice in 2013. Results: Seven patients had mediastinal disease, 2 had axillary disease, and 1 had disease in the neck only. The median age at diagnosis was 34 years (range, 21-74 years), and 5 patients were male. Of the resulting 50 treatment plans, 15 were planned with volumetric modulated arc therapy (1-4 arcs), 16 with intensity modulated RT (3-9 fields), and 19 with 3-dimensional conformal RT (2-4 fields). The variations in CTV-to-planning target volume margins (5-15 mm), maximum tolerated dose (31.4-40 Gy), and plan conformity (conformity index 0-3.6) were significant. However, estimated doses to OARs were comparable between centers for each patient. Conclusions: RT planning for HL is challenging because of the heterogeneity in size and location of disease and, additionally, to the variation in choice of treatment techniques and field arrangements. Adopting ILROG guidelines and implementing universal dose objectives could further standardize treatment techniques and contribute to lowering the dose to the surrounding OARs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Individualized Positron Emission Tomography–Based Isotoxic Accelerated Radiation Therapy Is Cost-Effective Compared With Conventional Radiation Therapy: A Model-Based Evaluation

Purpose: To evaluate long-term health effects, costs, and cost-effectiveness of positron emission tomography (PET)-based isotoxic accelerated radiation therapy treatment (PET-ART) compared with conventional fixed-dose CT-based radiation therapy treatment (CRT) in non-small cell lung cancer (NSCLC). Methods and Materials: Our analysis uses a validated decision model, based on data of 200 NSCLC patients with inoperable stage I-IIIB. Clinical outcomes, resource use, costs, and utilities were obtained from the Maastro Clinic and the literature. Primary model outcomes were the difference in life-years (LYs), quality-adjusted life-years (QALYs), costs, and the incremental cost-effectiveness and cost/utility ratio (ICER and ICUR) of PET-ART versus CRT. Model outcomes were obtained from averaging the predictions for 50,000 simulated patients. A probabilistic sensitivity analysis and scenario analyses were carried out. Results: The average incremental costs per patient of PET-ART were €569 (95% confidence interval [CI] €−5327-€6936) for 0.42 incremental LYs (95% CI 0.19-0.61) and 0.33 QALYs gained (95% CI 0.13-0.49). The base-case scenario resulted in an ICER of €1360 per LY gained and an ICUR of €1744 per QALY gained. The probabilistic analysis gave a 36% probability that PET-ART improves health outcomes at reduced costs and a 64% probability that PET-ART is more effective at slightly higher costs. Conclusion: On the basis of the available data, individualized PET-ART for NSCLC seems to be cost-effective compared with CRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quality of Intensity Modulated Radiation Therapy Treatment Plans Using a {sup 60}Co Magnetic Resonance Image Guidance Radiation Therapy System

Purpose: This work describes a commercial treatment planning system, its technical features, and its capabilities for creating {sup 60}Co intensity modulated radiation therapy (IMRT) treatment plans for a magnetic resonance image guidance radiation therapy (MR-IGRT) system. Methods and Materials: The ViewRay treatment planning system (Oakwood Village, OH) was used to create {sup 60}Co IMRT treatment plans for 33 cancer patients with disease in the abdominal, pelvic, thorax, and head and neck regions using physician-specified patient-specific target coverage and organ at risk (OAR) objectives. Backup plans using a third-party linear accelerator (linac)-based planning system were also created. Plans were evaluated by attending physicians and approved for treatment. The {sup 60}Co and linac plans were compared by evaluating conformity numbers (CN) with 100% and 95% of prescription reference doses and heterogeneity indices (HI) for planning target volumes (PTVs) and maximum, mean, and dose-volume histogram (DVH) values for OARs. Results: All {sup 60}Co IMRT plans achieved PTV coverage and OAR sparing that were similar to linac plans. PTV conformity for {sup 60}Co was within <1% and 3% of linac plans for 100% and 95% prescription reference isodoses, respectively, and heterogeneity was on average 4% greater. Comparisons of OAR mean dose showed generally better sparing with linac plans in the low-dose range <20 Gy, but comparable sparing for organs with mean doses >20 Gy. The mean doses for all {sup 60}Co plan OARs were within clinical tolerances. Conclusions: A commercial {sup 60}Co MR-IGRT device can produce highly conformal IMRT treatment plans similar in quality to linac IMRT for a variety of disease sites. Additional work is in progress to evaluate the clinical benefit of other novel features of this MR-IGRT system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Indicators of Psychosocial Distress Predict for Acute Radiation-Induced Fatigue in Patients Receiving Adjuvant Radiation Therapy for Breast Cancer: An Analysis of Patient-Reported Outcomes

Purpose: To assess the magnitude and predictors of patient-reported fatigue among breast cancer patients receiving radiation therapy (RT). Methods and Materials: Patients receiving breast RT completed a survey querying fatigue at each weekly on-treatment visit. Patient-reported fatigue severity and interference was assessed on an ordinal scale of 0 to 4, using a validated scoring system. Baseline anxiety and depression scores were also obtained. The kinetics of mean fatigue scores per week and the maximum fatigue scores over the course of the entire treatment were assessed, and clinical predictors were identified by univariate and multivariate regression. Results: The average fatigue severity and interference scores were 0.6 and 0.46. The average fatigue scores increased to an equivalent extent from week to week, with expected increases of 0.99 in fatigue severity and 0.85 in interference over 7 weeks. Patients treated with hypofractionated RT (HF-RT) versus conventionally fractionated RT (CF-RT) had significantly fewer maximum fatigue severity or interference scores that were >2 (ie, severe or very severe; 29% vs 10% for severity, and 26% vs 8% for interference, P<.01). Age ≤45 years, presence of psychiatric/pain-related comorbidities, and baseline sadness and anxiety severity were predictive of average and maximum fatigue scores (P<.05), but variables related to treatment intensity (eg, mastectomy vs lumpectomy, chemotherapy use, radiation target volumes) and other host factors (working, children, marital status, proximity to RT facility) were not. Conclusion: Patient-reported fatigue modestly increases over RT courses, with less maximum fatigue reported with HF-RT. Younger age and baseline sadness, anxiety, and psychiatric/pain-related comorbidities are powerful predictors of fatigue, whereas other factors, such as treatment intensity, are not. Future studies will investigate interventions for patients at high risk for fatigue.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simple Factors Associated With Radiation-Induced Lung Toxicity After Stereotactic Body Radiation Therapy of the Thorax: A Pooled Analysis of 88 Studies

Purpose: To study the risk factors for radiation-induced lung toxicity (RILT) after stereotactic body radiation therapy (SBRT) of the thorax. Methods and Materials: Published studies on lung toxicity in patients with early-stage non–small cell lung cancer (NSCLC) or metastatic lung tumors treated with SBRT were pooled and analyzed. The primary endpoint was RILT, including pneumonitis and fibrosis. Data of RILT and risk factors were extracted from each study, and rates of grade 2 to 5 (G2+) and grade 3 to 5 (G3+) RILT were computed. Patient, tumor, and dosimetric factors were analyzed for their correlation with RILT. Results: Eighty-eight studies (7752 patients) that reported RILT incidence were eligible. The pooled rates of G2+ and G3+ RILT from all 88 studies were 9.1% (95% confidence interval [CI]: 7.15-11.4) and 1.8% (95% CI: 1.3-2.5), respectively. The median of median tumor sizes was 2.3 (range, 1.4-4.1) cm. Among the factors analyzed, older patient age (P=.044) and larger tumor size (the greatest diameter) were significantly correlated with higher rates of G2+ (P=.049) and G3+ RILT (P=.001). Patients with stage IA versus stage IB NSCLC had significantly lower risks of G2+ RILT (8.3% vs 17.1%, odds ratio = 0.43, 95% CI: 0.29-0.64, P<.0001). Among studies that provided detailed dosimetric data, the pooled analysis demonstrated a significantly higher mean lung dose (MLD) (P=.027) and V20 (P=.019) in patients with G2+ RILT than in those with grade 0 to 1 RILT. Conclusions: The overall rate of RILT is relatively low after thoracic SBRT. Older age and larger tumor size are significant adverse risk factors for RILT. Lung dosimetry, specifically lung V20 and MLD, also significantly affect RILT risk.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose-Response Relationship in Stereotactic Body Radiation Therapy for Hepatocellular Carcinoma: A Pooled Analysis of an Asian Liver Radiation Therapy Group Study

Despite the worldwide implementation of stereotactic body radiation therapy (SBRT) for hepatocellular carcinoma (HCC), there is a lack of consensus guideline on prescription dose. Herein, this multinational study aimed to investigate the effects of the prescribed radiation dose on oncologic outcomes of SBRT for HCC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pain Response After Stereotactic Body Radiation Therapy Versus Conventional Radiation Therapy in Patients With Bone Metastases—A Phase 2 Randomized Controlled Trial Within a Prospective Cohort

Pain response after conventional external beam radiation therapy (cRT) in patients with painful bone metastases is observed in 60% to 70% of patients. The aim of the VERTICAL trial was to investigate whether stereotactic body radiation therapy (SBRT) improves pain response.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Wave like signatures in aerosol optical depth and associated radiative impacts over the central Himalayan region

Doppler Lidar and Multi-Filter Rotating Shadowband Radiometer (MFRSR) observations are utilized to show wave like signatures in aerosol optical depth (AOD) during daytime boundary layer evolution over the Himalayan region. Fourier analysis depicted 60–80 min periods dominant during afternoon hours, implying that observed modulations could be plausible reason for the AOD forenoon–afternoon asymmetry which was previously reported. Inclusion of wave amplitude in diurnal variation of aerosol radiative forcing estimates showed ~40% additional warming in the atmosphere relative to mean AOD. The present observations emphasize the importance of wave induced variations in AOD and radiation budget over the site.

Aerosol optical depth↗

PracticeCALM: Coaching Anxiety Lessening Methods for Radiation Therapists: A Pilot Study of a Skills-Based Training Program in Radiation Oncology

PracticeCALM is an 8-week on-the-job training program to teach radiation therapists (RTs) techniques for assisting patients who are experiencing treatment-related anxiety. Twelve clinical RTs in a regional oncology program were recruited on a volunteer basis to participate in the training. A mixed-method approach was undertaken to evaluate perceived benefits to clinical practice. The quantitative findings from the Perceived Stress Scale (PSS) showed there were no changes before and after training. Qualitative findings showed significant benefits to RTs, including (1) ability to empathically attune more effectively and earlier to signs of anxiety in patients; (2) improved confidence and self-efficacy for effectively intervening in difficult treatment situations; and (3) enhanced creative problem solving in partnership with patients to assist the acutely anxious patient. The PSS results suggest that intrinsic and extrinsic stressors are a variable but consistent part of the everyday reality of RT practice. A training program focusing on the therapeutic presence dimension of RT practice has a direct impact on effectiveness in assisting anxious patients undergoing RT. When embedded in the clinical life of a radiation therapy department, such a training program has the potential to capture the lived practice wisdom and creative skills of RTs, and effectively mediate these skills across a team through group discussions and documentation on patient charts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Demonstrating GPU code portability and scalability for radiative heat transfer computations

High performance computing frameworks utilizing CPUs, Nvidia GPUs, and/or Intel Xeon Phis necessitate portable and scalable solutions for application developers. Nvidia GPUs in particular present numerous portability challenges with a different programming model, additional memory hierarchies, and partitioned execution units among streaming multiprocessors. This work presents modifications to the Uintah asynchronous many-task runtime and the Kokkos portability library to enable one single codebase for complex multiphysics applications to run across different architectures. Scalability and performance results are shown on multiple architectures for a globally coupled radiation heat transfer simulation, ranging from a single node to 16,384 Titan compute nodes.

Computer Science↗