Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

TomoGAN: low-dose synchrotron x-ray tomography with generative adversarial networks: discussion

Synchrotron-based x-ray tomography is a noninvasive imaging technique that allows for reconstructing the internal structure of materials at high spatial resolutions from tens of micrometers to a few nanometers. In order to resolve sample features at smaller length scales, however, a higher radiation dose is required. Therefore, the limitation on the achievable resolution is set primarily by noise at these length scales. We present TomoGAN, a denoising technique based on generative adversarial networks, for improving the quality of reconstructed images for low-dose imaging conditions. We evaluate our approach in two photon-budget-limited experimental conditions: (1) sufficient number of low-dose projections (based on Nyquist sampling), and (2) insufficient or limited number of high-dose projections. In both cases, the angular sampling is assumed to be isotropic, and the photon budget throughout the experiment is fixed based on the maximum allowable radiation dose on the sample. Evaluation with both simulated and experimental datasets shows that our approach can significantly reduce noise in reconstructed images, improving the structural similarity score of simulation and experimental data from 0.18 to 0.9 and from 0.18 to 0.41, respectively. Furthermore, the quality of the reconstructed images with filtered back projection followed by our denoising approach exceeds that of reconstructions with the simultaneous iterative reconstruction technique, showing the computational superiority of our approach.

42 ENGINEERING↗

Analysis of Ag/FEP Control Blanket Performance from Multiple Satellites

Published data reporting the change in solar absorptance as a function of time on orbit for certain satellites has been re-examined. The optical property change of metallized FEP as a function of total particulate radiation dose received by specific satellites has been estimated. Results tend to follow a common trend and a design curve has been constructed to estimate solar absorptance change as a function of radiation dose for metallized FEP at any altitude. Effects due to apparent contamination on several of the satellites are addressed and taken into account in determining property changes. Data from LDEF, ML-101, NavStar 1-5, NTS-2, the SCATHA experiment, and SOLRAD 11 are used as the basis of the design curve. A similar comparison is made between published atomic oxygen recession data from numerous Space Shuttle flights, a LEO experiment flown by Lockheed, and LDEF results. Variation of atomic oxygen recession rate of FEP as a function of exposure conditions is determined.

Pippin, H. G.↗

A Parametric Analysis of Factors Affecting Calculations of Estimated Dose Rates from Spent Nuclear Fuel Shipments - 16458

Planning for transportation of SNF requires estimation of the radiation dose to the members of the public associated with the transportation. This dose is expected to be very low compared to natural background radiation because dose rates and exposure durations are minimal. A preliminary investigation was performed to estimate the dose rate from a SNF transportation package as a function of distance and evaluate factors affecting the estimated dose rate, such as local environment modeling. Effects on the dose rate are determined for changes in temperature and relative humidity of the air surrounding a transportation package and for different compositions of the ground underneath it. The impact of different vapor content in air was evaluated to be small, within the statistical uncertainty of the dose rate estimates. The neutron dose rate contributions from scattering interactions within different soil/pavement materials were from approximately 20% to 70% at 25 cm from the ground and from approximately 10% to 40% at 175 cm from the ground. The effect of photon scattering interactions within different soil/pavement materials was an increase in photon dose rate of less than 20% at 25 cm from the ground and less than 10% at 175 cm from the ground. The impact of different ground materials on the total dose rate would depend on the relative contributions of photon and neutron dose rates to the total dose rate. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-I-87: Calibrating Cherenkov Emission to Match Superficial Dose in Tissue

Purpose: Through Monte Carlo simulations and phantom studies, the dominant factors affecting the calibration of superficial Cherenkov intensity to absolute surface dose was investigated, including tissue optical properties, curvatures, beam properties and imaging angle. Methods: The phasespace files for the TrueBeam system from Varian were used in GAMOS (a GEANT4 based Monte Carlo simulation toolkit) to simulate surface emission Cherenkov signals and the correlated deposited dose. The parameters examined were: i) different tissue optical properties (skin color from light to dark), ii) beam types (X-ray and electron beam), iii) beam energies, iv) thickness of tissues (2.5 cm to 20 cm), v) SSD (80 cm to 120 cm), vi) field sizes (0.5×0.5 cm2 to 20×20 cm2), vii) entrance/exit sides, viii) curvatures (cylinders with diameters from 2.5 cm to 20cm) and ix) imaging angles (0 to 90 degrees). In a specific case, for any Cherenkov photon emitted from the surface, the original position and direction, final position and direction and energy were recorded. Similar experimental measurements were taken in a range of the most pertinent parameters using tissue phantoms. Results: Combining the dose distribution and sampling sensitivity of Cherenkov emission, quantitatively accurate calibration factors (the amount of radiation dose represented by a single Cherenkov photon) were calculated. The data showed relatively large dependence upon different optical properties, curvature, entrance/exit and beam types. For a diffusive surface, the calibration factor was insensitive to imaging angles smaller than 60 degrees. Normalization with the reflectance image was experimentally validated as a simple and accurate method for calibrations of different optical properties. Conclusion: This study sheds light on how and to what extent different conditions affect the calibration from Cherenkov intensity to absolute superficial dose and provides practical solutions to allow quantitative Cherenkov imaging to be used as a dose surrogate for imaging.

60 APPLIED LIFE SCIENCES↗

Gamma Radiation Aging Study of a Dow Corning SE 1700 Porous Structure Made by Direct Ink Writing

Dow Corning SE 1700 (reinforced polydimethylsiloxane) porous structures were made by direct ink writing (DIW). The specimens (~50% porosity) were subjected to a compressive strain of ~25% while exposed to a gamma radiation dose of 1, 5, or 10 Mrad under vacuum. Compression set and load retention of the aged specimens were measured after a ~24 h relaxation period. Compression set (relative to deflection) increased with radiation dose: 11, 35, and 51% after 1, 5, and 10 Mrad, respectively. Load retention was 96-97% for the doses tested. The SE 1700 compared favorably to M9763 cellular silicone tested under the same conditions.

36 MATERIALS SCIENCE↗

SU-E-I-20: Comprehensive Quality Assurance Test of Second Generation Toshiba Aquilion Large Bore CT Simulator Based On AAPM TG-66 Recommendations

Purpose: AAPM radiation therapy committee task group No. 66 (TG-66) published a report which described a general approach to CT simulator QA. The report outlines the testing procedures and specifications for the evaluation of patient dose, radiation safety, electromechanical components, and image quality for a CT simulator. The purpose of this study is to thoroughly evaluate the performance of a second generation Toshiba Aquilion Large Bore CT simulator with 90 cm bore size (Toshiba, Nasu, JP) based on the TG-66 criteria. The testing procedures and results from this study provide baselines for a routine QA program. Methods: Different measurements and analysis were performed including CTDIvol measurements, alignment and orientation of gantry lasers, orientation of the tabletop with respect to the imaging plane, table movement and indexing accuracy, Scanogram location accuracy, high contrast spatial resolution, low contrast resolution, field uniformity, CT number accuracy, mA linearity and mA reproducibility using a number of different phantoms and measuring devices, such as CTDI phantom, ACR image quality phantom, TG-66 laser QA phantom, pencil ion chamber (Fluke Victoreen) and electrometer (RTI Solidose 400). Results: The CTDI measurements were within 20% of the console displayed values. The alignment and orientation for both gantry laser and tabletop, as well as the table movement and indexing and scanogram location accuracy were within 2mm as specified in TG66. The spatial resolution, low contrast resolution, field uniformity and CT number accuracy were all within ACR’s recommended limits. The mA linearity and reproducibility were both well below the TG66 threshold. Conclusion: The 90 cm bore size second generation Toshiba Aquilion Large Bore CT simulator that comes with 70 cm true FOV can consistently meet various clinical needs. The results demonstrated that this simulator complies with the TG-66 protocol in all aspects including electromechanical component, radiation safety component, and image quality component. Employee of Toshiba America Medical Systems.

60 APPLIED LIFE SCIENCES↗

Gamma radiation stand-off detection, tamper detection, and authentication via resonant meta-material structures

Resonant meta-material structures are defined by metallic, dielectric or other materials that form nanoshells or nanomeshes that can be situated proximate to ionizing-radiation-sensitive layers so as to provide ionizing-radiation-dose-dependent optical properties. Such meta-material structures can also define aligned or periodic, semi-random, or other arrangements of nanostructures that are coupled to or include stressed layers. Detection of optical radiation from such structures is used to determine gamma radiation dose or to detect a disturbance of the nanostructure indicating tampering.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fractionated changes in prostate cancer radiotherapy using cone-beam computed tomography

The high mobility of the bladder and the rectum causes uncertainty in radiation doses prescribed to patients with prostate cancer who undergo radiotherapy (RT) multifraction treatments. The purpose of this study was to estimate the dose received by the bladder, rectum, and prostate from multifraction treatments using daily cone-beam computed tomography (CBCT). Overall, 28 patients with prostate cancer who planned to receive radiation treatments were enrolled in the study. The acquired CBCT before the treatment delivery was registered with the planning CT to map the dose distribution used in the treatment plan for estimating the received dose during clinical treatment. For all 28 patients with 112 data sets, the mean percentage differences (± standard deviation) in the volume and radiation dose were 44% (± 41) and 18% (± 17) for the bladder, 20% (± 21) and 2% (± 2) for the prostate, and 36% (± 29) and 22% (± 15) for the rectum, respectively. Substantial differences between the volumes and radiation dose and those specified in treatment plans were observed. Besides the use of image-guided RT to improve patient setup accuracy, further consideration of large changes in bladder and rectum volumes is strongly suggested when using external beam radiation for prostate cancer.

61 RADIATION PROTECTION AND DOSIMETRY↗

Career Excess Mortality Risk from Diagnostic Radiological Exams Required for Crewmembers Participating in Long Duration Space Flight

NASA requires astronauts to undergo diagnostic x-ray examinations as a condition for their employment. The purpose of these procedures is to assess the astronaut s overall health and to diagnose conditions that could jeopardize the success of long duration space missions. These include exams for acceptance into the astronaut corps, routine periodic exams, as well as evaluations taken pre and post missions. Issues: According to NASA policy these medical examinations are considered occupational radiological exposures, and thus, are included when computing the astronaut s overall radiation dose and associated excess cancer mortality risk. As such, astronauts and administrators are concerned about the amount of radiation received from these procedures due to the possibility that these additional doses may cause astronauts to exceed NASA s administrative limits, thus disqualifying them from future flights. Methods: Radiation doses and cancer mortality risks following required medical radiation exposures are presented herein for representative male and female astronaut careers. Calculation of the excess cancer mortality risk was performed by adapting NASA s operational risk assessment model. Averages for astronaut height, weight, number of space missions and age at selection into the astronaut corps were used as inputs to the NASA risk model. Conclusion: The results show that the level of excess cancer mortality imposed by all required medical procedures over an entire astronaut s career is approximately the same as that resulting from a single short duration space flight (i.e. space shuttle mission). In short the summation of all medical procedures involving ionizing radiation should have no impact on the number of missions an astronaut can fly over their career. Learning Objectives: 1. The types of diagnostic medical exams which astronauts are subjected to will be presented. 2. The level of radiation dose and excess mortality risk to the average male and female astronaut will be presented.

Dodge, C. W.↗

Solar-flare shielding with Regolith at a lunar-base site

The Langley high energy nucleon transport computer code BRYNTRN is used to predict time-integrated radiation dose levels at the lunar surface due to high proton flux from solar flares. The study addresses the shielding requirements for candidate lunar habitat configurations necessary to protect crew members from these large and unpredictable radiation fluxes. Three solar proton events have been analyzed, and variations in radiation intensity in a shield medium due to the various primary particle energy distributions are predicted. Radiation dose predictions are made for various slab thicknesses of a lunar soil model. Results are also presented in the form of dose patterns within specific habitat configurations shielded with lunar material.

Nealy, John E.↗

Diamond dose rate detector testing at KURRI- A joint UK-Japan research project - 17126

Measurements of radiation dose rates in highly active environments, such as nuclear plant decommissioning or following a nuclear disaster, is challenging due to the extreme environments encountered and restricted access. Therefore, novel radiation detector technology is required to address these challenges. One such example of a radiation detection material is diamond, as it is able to withstand and measure high radiation intensities, is chemically inert and formable into extremely small, sensitive detectors. These detectors generate small currents when exposed to radiation, and if the radiation levels are high enough this can be measured. Testing of such detectors is not possible in routine laboratories due to the requirement to have high active radiation sources. However, through a new collaboration formed through the University of Bristol- Kyoto University bilateral symposia such facilities are accessible for UK researchers at Kyoto University Research Reactor Institute. This paper presents an overview of the collaborative research project, the accessible facilities for device manufacture and testing and some early results from radiation testing of diamond detectors at KURRI. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam Attenuators and the Risk of Unrecognized Large-Fraction Irradiation of Critical Tissues

The use of radiation beam attenuators led to radiation injury of the spinal cord in one patient and of the peripheral nerve in another due to unsuspected large-fraction irradiation. The anatomic distribution of radiation dose was reconstructed in the sagittal plane for the patient who developed radiation myelopathy and in the axial plane for the patient who developed peripheral neuropathy. The actual dose delivered to the injured structure in each patient was taken from the dose distribution and recorded along with the time, number of fractions, and dose per fraction. The patient who developed radiation myelopathy received a total of 46.5 Gy in twenty-three 2.1 Gy fractions in 31 days to the upper cervical spinal cord where the thickness of the neck was less than the central axis thickness due to cervical lordosis and absence of a posterior compensating filter. The patient who developed peripheral neuropathy received 55 Gy in twenty-five 2.2 Gy fractions in 50 days to the femoral nerve using bolus over the groins and an anterior one-half value layer Cerrobend pelvic block to bias the dose anteriorly. Compensating filters and other beam attenuators should be used with caution because they may result in unsuspected large-fraction irradiation and total doses of radiation that exceed the tolerance of critical structures.

61 RADIATION PROTECTION AND DOSIMETRY↗

WE-EF-207-04: An Inter-Projection Sensor Fusion (IPSF) Approach to Estimate Missing Projection Signal in Synchronized Moving Grid (SMOG) System

Purpose: A synchronized moving grid (SMOG) has been proposed to reduce scatter and lag artifacts in cone beam computed tomography (CBCT). However, information is missing in each projection because certain areas are blocked by the grid. A previous solution to this issue is acquiring 2 complimentary projections at each position, which increases scanning time. This study reports our first Result using an inter-projection sensor fusion (IPSF) method to estimate missing projection in our prototype SMOG-based CBCT system. Methods: An in-house SMOG assembling with a 1:1 grid of 3 mm gap has been installed in a CBCT benchtop. The grid moves back and forth in a 3-mm amplitude and up-to 20-Hz frequency. A control program in LabView synchronizes the grid motion with the platform rotation and x-ray firing so that the grid patterns for any two neighboring projections are complimentary. A Catphan was scanned with 360 projections. After scatter correction, the IPSF algorithm was applied to estimate missing signal for each projection using the information from the 2 neighboring projections. Feldkamp-Davis-Kress (FDK) algorithm was applied to reconstruct CBCT images. The CBCTs were compared to those reconstructed using normal projections without applying the SMOG system. Results: The SMOG-IPSF method may reduce image dose by half due to the blocked radiation by the grid. The method almost completely removed scatter related artifacts, such as the cupping artifacts. The evaluation of line pair patterns in the CatPhan suggested that the spatial resolution degradation was minimal. Conclusion: The SMOG-IPSF is promising in reducing scatter artifacts and improving image quality while reducing radiation dose.

60 APPLIED LIFE SCIENCES↗

Features of the electrical conductivity of TlInSe{sub 2} under photoexcitation and X-ray excitation

The current–voltage characteristics of TlInSe{sub 2} crystals under photoexcitation and X-ray excitation are studied. The parameters of the trap, which are equal to N{sub t} = 5 × 10{sup 16} cm{sup –3}, n{sub t} = 4.5 × 10{sup 12} cm{sup –3}, and ΔE{sub t} = 0.42 eV, are calculated. The calculated values of N{sub t} and n{sub t} before and after X-ray excitation are equal to 3 × 10{sup 16} cm{sup –3} and 3.2 × 10{sup 12} cm{sup –3}, respectively. The dependences of the X-ray conductances on the radiation intensity are studied for TlInSe{sub 2} crystals at various accelerating voltages V{sub a} and it is determined that the X-ray conductance K{sub σ} decreases exponentially as the accelerating voltage V{sub a} and radiation dose increase.

36 MATERIALS SCIENCE↗

Recommendations for harmonized reporting of radiation Dosimetry by adoption of Compatibility in Irradiation Research Protocols Expert Roundtable (CIRPER)

Here, in radiobiology, radiation physics, and related areas, there is growing interest in transitioning from cesium-based irradiators to X-ray technologies. Therefore, it makes it imperative for reproducibility purposes, for researchers to provide specifications regarding device parameters, machine calibration details, and experimental setup when innovative X-ray technology is being employed. Several groups have already identified a glaring lack in completeness of critical information on experimental setups, equipment, and physical parameters in published radiation biology studies. The Alternative Technologies Meta Study Report by Brookhaven National Laboratory (BNL) examined 456 manuscripts published between 2017-2021. Only 64 of the reviewed studies (14.0%) consistently reported methods that could allow for replication of their studies. However, 85% provided information on the manufacturer, the irradiator model and the absorbed radiation dose. Approximately 66% provided information on the energy spectra and the dose rate, but only one third disclosed the filter used. Less than 15% of the reviewed studies reported information on calibration and field geometry, specifically field size and distance from source, which are critical parameters in determining the absorbed radiation dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Means and procedures for stopping a criticality accident in the MELOX homogeniser

The purpose of this paper is to describe the organizational and material changes as well as the intervention procedure in order to stop a hypothetical criticality accident in the MELOX homogenizer. By extension, this study will take into account a criticality accident in other workstations of the production chain. It establishes that stopping a criticality accident in the homogenizer requires that 20 kg of hafnium oxide will be injected into its tank. This admission will be carried out in two stages: initially operators have to pour 20 kg of hafnium oxide into a jar, then in a second step this jar will be brought, using a manual mode controlled by an automation technician, into the homogenizing workstation from a distant controller. Then, from this distant controller, the technician will blend the MOX with the hafnium in the homogenizer, and eventually stop the accident. These interventions involve the inhibition of safety PLC and the permanent radiation monitoring in the rooms where human presence is necessary. The foreseen radiation doses are studied and are encouraging. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Multiple indicators, multiple causes measurement error models

Multiple indicators, multiple causes (MIMIC) models are often employed by researchers studying the effects of an unobservable latent variable on a set of outcomes, when causes of the latent variable are observed. There are times, however, when the causes of the latent variable are not observed because measurements of the causal variable are contaminated by measurement error. The objectives of this study are as follows: (i) to develop a novel model by extending the classical linear MIMIC model to allow both Berkson and classical measurement errors, defining the MIMIC measurement error (MIMIC ME) model; (ii) to develop likelihood-based estimation methods for the MIMIC ME model; and (iii) to apply the newly defined MIMIC ME model to atomic bomb survivor data to study the impact of dyslipidemia and radiation dose on the physical manifestations of dyslipidemia. Finally, as a by-product of our work, we also obtain a data-driven estimate of the variance of the classical measurement error associated with an estimate of the amount of radiation dose received by atomic bomb survivors at the time of their exposure.

97 MATHEMATICS AND COMPUTING↗

SCALE Analyses of Scenarios in the Molten Salt Reactor Fuel Cycle

In support of the US Nuclear Regulatory Commission non-light-water reactor fuel cycle demonstration project, the capabilities of SCALE 6.3.1 for radionuclide characterization, criticality, and shielding were demonstrated through several scenarios in a molten salt reactor (MSR) nuclear fuel cycle. Three scenarios were selected for this study, with the molten salt breeder reactor (MSBR) serving as the reference design. The original thorium-based fuel salt used in MSBR was replaced with a 235 U-enriched fuel salt to better reflect anticipated future MSR concepts. The first scenario focused on the fuel salt preparation stage. Criticality analyses, using SCALE/CSAS-Shift and SCALE/SAMPLER, examined potential critical configurations in the fresh fuel salt container based on variables such as 235 U enrichment, UF 4 molar fraction, temperature, and container geometry. The second scenario explored the release of fission products during reactor operation in which the tritium buildup in the primary fuel salt was quantified through depletion calculations using SCALE/TRITON with continuous fuel makeup and fractional fission product removal. This scenario also assessed radioactivity levels in the off-gas system (OGS), quantifying radiotoxic nuclides that could be released into the environment. SCALE/SAMPLER was employed to perform uncertainty quantification to identify key operating parameters influencing the buildup of radiotoxic nuclides in the OGS. Additionally, radiation dose rates were calculated using SCALE/MAVRIC to estimate the maximum exposure levels within the reactor cell complex during operation. The final scenario evaluated the decay heat and radioactivity of the primary fuel salt collected in the drain tank, as well as the radiation dose rate outside the building from the presence of the drain tank. Overall, the application of SCALE’s various capabilities for radionuclide inventory generation, criticality analysis, and shielding in MSR fuel cycles was successfully demonstrated across these scenarios.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗