Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Optical Spectrometer With a Pulse-to-Pulse Resolution for Terahertz and mm-Wave Signals

The development of ultra-compact particle accelerators and accelerator-based high-power THz generators are some of the top priorities for research and development programs around the world. These tools require the development of accelerating structures, operating in the mm-Wave and THz range, where diagnostics are not available or are insufficient. This article presents the design of a pulse-to-pulse THz spectrometer, primarily developed for diagnostics of accelerating structures and THz radiation sources. In particular, this spectrometer can be used to detect RF pulse shortening caused by vacuum breakdown and beam misalignment in THz accelerators, as well as for bunch length monitoring and radiation source diagnostics. The spectrometer is based on a diffraction grating and is capable of covering a frequency range where RF-based breakdown measurements are not possible. We have built and tested the first prototype with different sources in a frequency range of 0.1-1.0 THz. In this article, we present the physical design, supported numerical simulations, electronics development, and test results.

47 OTHER INSTRUMENTATION↗

SU-E-T-351: Verification of Monitor Unit Calculation for Lung Stereotactic Body Radiation Therapy Using a Secondary Independent Planning System

Purpose: To compare isocenter (IC) dose between X-ray Voxel Monte Carlo (XVMC) and Acuros XB (AXB) as part of an independent verification of monitor unit (MU) calculation for lung stereotactic body radiation therapy (SBRT) using a secondary independent treatment planning system (TPS). Methods: Treatment plans of 110 lesions from 101 patients who underwent lung SBRT with Vero4DRT (Mitsubishi Heavy Industries, Ltd., Japan, and BrainLAB, Feldkirchen, Germany) were evaluated retrospectively. Dose distribution was calculated with X-ray Voxel Monte Carlo (XVMC) in iPlan 4.5.1 (BrainLAB, Feldkirchen, Germany) on averaged intensity projection images. A spatial resolution and mean variance were 2 mm and 2%, respectively. The clinical treatment plans were transferred from iPlan to Eclipse (Varian Medical Systems, Palo Alto, CA, USA), and doses were recalculated with well commissioned AXB ver. 11.0.31 while maintaining the XVMC-calculated MUs and beam arrangement. Dose calculations were made in the dose-to-medium dose reporting mode with the calculation grid size of 2.5 mm. The mean and standard deviation (SD) of the IC dose difference between XVMC and AXB were calculated. The tolerance level was defined as |mean|+2SD. Additionally, the relationship between IC dose difference and the size of planning target volume (PTV) or computed tomography (CT) value of internal target volume (ITV) was evaluated. Results: The mean±SD of the IC dose difference between XVMC and AXB was −0.32±0.73%. The tolerance level was 1.8%. Absolute IC dose differences exceeding the tolerance level were observed in 3 patients (2.8%). There were no strong correlations between IC dose difference and PTV size (R=−0.14) or CT value of ITV (R=−0.33). Conclusion: The present study suggested that independent verification of MU calculation for lung SBRT using a secondary TPS is useful.

60 APPLIED LIFE SCIENCES↗

The Effect of Realtime Monitoring on Dose Exposure to Staff Within an Interventional Radiology Setting

PurposeThe purpose of this study is to evaluate a new device providing real-time monitoring on radiation exposure during fluoroscopy procedures intending to reduce radiation in an interventional radiology setting.Materials and MethodsIn one interventional suite, a new system providing a real-time radiation dose display and five individual wireless dosimeters were installed. The five dosimeters were worn by the attending, fellow, nurse, technician, and anesthesiologist for every procedure taking place in that suite. During the first 6-week interval the dose display was off (closed phase) and activated thereafter, for a 6-week learning phase (learning phase) and a 10-week open phase (open phase). During these phases, the staff dose and the individual dose for each procedure were recorded from the wireless dosimeter and correlated with the fluoroscopy time. Further subanalysis for dose exposure included diagnostic versus interventional as well as short (<10 min) versus long (>10 min) procedures.ResultsA total of 252 procedures were performed (n = 88 closed phase, n = 50 learning phase, n = 114 open phase). The overall mean staff dose per fluoroscopic minute was 42.79 versus 19.81 µSv/min (p < 0.05) comparing the closed and open phase. Thereby, anesthesiologists were the only individuals attaining a significant dose reduction during open phase 16.9 versus 8.86 µSv/min (p < 0.05). Furthermore, a significant reduction of total staff dose was observed for short 51 % and interventional procedures 45 % (p < 0.05, for both).ConclusionA real-time qualitative display of radiation exposure may reduce team radiation dose. The process may take a few weeks during the learning phase but appears sustained, thereafter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Classification of background suppression profiles for low background RPM data

Suppression of the ambient gamma background radiation by traffic structure and cargo is a well-understood and studied effect for deployed radiation portal monitors (RPM). For effective analysis of measured RPM profiles with the objective of inferring the spatial characteristics of radiation sources, it is important to account for the effects of background suppression. In this report we analyze background suppression for a test dataset from vehicle RPMs at a sample port and estimate the distributions of suppression amplitudes and shapes. Cluster analysis of standardized and normalized profiles is used to obtain the dominant suppression shapes in the sample field data. We determine that a large fraction of non-alarm RPM occupancies are represented by a small number of suppression shapes. This fraction increases when the signal-to-noise ratio of an occupancy profile is improved by the addition of signals for multiple RPM detectors located at the same height. The calculated suppression shapes from RPM data can be used along with source models in the process of spatial profile analysis both in the field or offline. This background suppression analysis is an important step in improving the effectiveness of the RPM profile analysis methodology which is currently being investigated and may lead to methods that reduce the number of secondary inspections as well as to decision support tools that aid operators in evaluating RPM data that do not contain spectral information.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The 3He Supply Problem

One of the main uses for 3He is in gas proportional counters for neutron detection. Radiation portal monitors deployed for homeland security and non-proliferation use such detectors. Other uses of 3He are for research detectors, commercial instruments, well logging detectors, dilution refrigerators, for targets or cooling in nuclear research, and for basic research in condensed matter physics. The US supply of 3He comes almost entirely from the decay of tritium used in nuclear weapons by the US and Russia. A few other countries contribute a small amount to the world’s 3He supply. Due to the large increase in use of 3He for homeland security, the supply has dwindled, and can no longer meet the demand. This white paper reviews the problems of supply, utilization, and alternatives.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lithium and Zinc Sulfide Coated Plastic Neutron Detector Test

Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. In addition, a few other companies have detector technologies that might be competitive in the near term as an alternative technology. Reported here are the results of tests of 6Li/ZnS(Ag)-coated scintillator paddles. This testing measured the required performance for neutron detection efficiency and gamma ray rejection capabilities of a system manufactured by Symetrica.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cosmic ray particles with different LET values under various thicknesses of shielding in low altitude orbits: calculations and Cosmos-2044 measurements

Fluxes of cosmic ray particles with different LET values were measured on board the Cosmos-2044 biosatellite under various thicknesses of shielding by stacks of CR-39 and nitrocellulose plastic nuclear track detectors (mounted outside the satellite). The component composition of the particles detected under shieldings of 0.1-2.5 g cm-2 is verified by comparing experimental data with the results of model simulations of the fluxes of galactic cosmic ray particles and of radiation belt protons.

NASA Discipline Radiation Health↗

Evaluation of internal contamination levels after a radiological dispersal device incident using portal monitors

Following a radioactive dispersal device (RDD) incident, it may be necessary to evaluate the internal contamination levels of a large number of potentially affected individuals to determine if immediate medical follow-up is necessary. Since the current laboratory capacity to screen for internal contamination is limited, rapid field screening methods can be useful in prioritizing individuals. This study evaluated the suitability of a radiation portal monitor for such screening. A model of the portal monitor was created for use with models of six anthropomorphic phantoms in Monte Carlo N-Particle Transport Code Version 5 (MCNP) X-5 Monte Carlo Team (MCNP A General Monte Carlo N-Particle Transport Code Version 5. LA-CP-03-0245. Vol. 2. Los Alamos National Laboratory, 2004.). The count rates of the portal monitor were simulated for inhalation and ingestion of likely radionuclides from an RDD for each of the phantoms. The time-dependant organ concentrations of the radionuclides were determined using Dose and Risk Calculation Software Eckerman, Leggett, Cristy, Nelson, Ryman, Sjoreen and Ward (Dose and Risk Calculation Software Ver. 8.4. ORNL/TM-2001/190. Oak Ridge National Laboratory, 2006.). Portal monitor count rates corresponding to a committed effective dose E(50) of 10 mSv are reported.

61 RADIATION PROTECTION AND DOSIMETRY↗

Critical review of gamma spectrometry detection approaches for in-plant surface deposition monitoring

Surface deposition of activated corrosion product on oxide layers of light-water reactor primary system components is the primary source for ex-core radiation fields and personnel radiation exposure. Understanding the deposition mechanism and what factors influence the deposition and release behaviors are crucial for developing effective radiation field reduction measures. One of the available tools to assess the surface deposition is in-plant gamma spectrometry, which has been performed for several decades using either sodium iodide (NaI) or high-purity germanium (HPGe) detectors. Lately, the much more mobile cadmium-zinc-telluride (CZT) detectors are increasingly employed by stations because of their ease in use and handling. However, all of these gamma detectors face the same challenges; namely large-geometry samples of inconsistent sample compositions and sometimes gaps in the information necessary to establish proper efficiency calibrations. This paper reviews current measurements and efficiency calibration approaches taken in the industry. The validity of the measurement results and the feasibility of the data's use in understanding source term behavior is examined. Suggestions are made for the development of a more robust deposit characterization and radiation field monitoring program. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

PVT Analysis With A Deconvolution Algorithm

Polyvinyl Toluene (PVT) plastic scintillator is the most common gamma ray detector material used for large systems when only gross counting is needed because of its low cost, robustness, and relative sensitivity. PVT does provide some energy information about the incident photons, as has been demonstrated through the development of Energy Windowing analysis. There is a more sophisticated energy analysis algorithm developed by Symetrica, Inc., and they have demonstrated the application of their deconvolution algorithm to PVT with very promising results. The thrust of such a deconvolution algorithm used with PVT is to allow for identification and rejection of naturally occurring radioactive material, reducing alarm rates, rather than the complete identification of all radionuclides, which is the goal of spectroscopic portal monitors. Under this condition, there could be a significant increase in sensitivity to threat materials. The advantage of this approach is an enhancement to the low cost, robust detection capability of PVT-based radiation portal monitor systems. The success of this method could provide an inexpensive upgrade path for a large number of deployed PVT-based systems to provide significantly improved capability at a much lower cost than deployment of NaI(Tl)-based systems of comparable sensitivity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Final Report: Non-Visible, Automated Target Acquisition and Tracking

The Roadside Tracker (RST) represents a new approach to radiation portal monitors. It uses a combination of gamma-ray and visible-light imaging to localize gamma-ray radiation sources to individual vehicles in free-flowing, multi-lane traffic. Deployed as two trailers that are parked on either side of the roadway (Fig. 1); the RST scans passing traffic with two large gamma-ray imagers, one mounted in each trailer. The system compensates for vehicle motion through the imager’s fields of view by using automated target acquisition and tracking (TAT) software applied to a stream of video images. Once a vehicle has left the field of view, the radiation image of that vehicle is analyzed for the presence of a source, and if one is found, an alarm is sounded. The gamma-ray image is presented to the operator together with the video image of the traffic stream when the vehicle was approximately closest to the system (Fig. 2). The offending vehicle is identified with a bounding box to distinguish it from other vehicles that might be present at the same time. The system was developed under a previous grant from the Department of Homeland Security’s (DHS’s) Domestic Nuclear Detection Office (DNDO). This report documents work performed with follow-on funding from DNDO to further advance the development of the RST. Specifically, the primary thrust was to extend the performance envelope of the system by replacing the visible-light video cameras used by the TAT software with sensors that would allow operation at night and during inclement weather. In particular, it was desired to allow operation after dark without requiring external lighting. As part of this work, the system software was also upgraded to allow the use of 64-bit computers, the current generation operating system (OS), software development environment (Windows 7 vs. Windows XP, and current Visual Studio.Net), and improved software version controls (GIT vs. Source Safe.) With the upgraded performance allowed by new computers, and the additional memory available in a 64-bit OS, the system was able to handle greater traffic densities, and this also allowed addition of the ability to handle stop-and-go traffic.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Nuclear Smuggling Detection and Deterrence (FY 2018 Data Analysis Annual Report)

The National Nuclear Security Administration’s Office of Nuclear Smuggling Detection and Deterrence (NSDD) has facilitated the installation of more than 3,728 radiation portal monitors (RPMs) at 660 sites in 63 countries. This collection of RPMs represents the world’s largest network of radiation detectors and provides one element of the defense-in-depth approach that supports the Global Nuclear Detection Architecture. These systems support NSDD’s mission to build partner country capability to deter, detect, and interdict the illicit transport of radiological and fissile material through strategic points of entry and exit at seaports, airports, and border crossings.NSDD works collaboratively with partner countries and international organizations to optimize the operation of these RPMs. The large amount of data provided by NSDD partner countries (summarized in the banner to the right) highlights the close cooperation and partnerships NSDD has built with 63 countries around the world. Thirty-two of these countries shared at least some RPM-related data with NSDD in fiscal year (FY) 2018. This significant level of data sharing is a key element that distinguishes the NSDD office as unique among nuclear nonproliferation programs and initiatives: NSDD can provide specific, objective, data-driven decisions and support for sustaining the radiation detection systems it helped deploy. This data analysis report summarizes and aggregates the RPM data provided to the NSDD office for analysis and review in FY 2018.The data can be used to describe RPM performance and characterize the wide diversity of NSDD deployment sites. For example, NSDD deploys detector systems across sites with natural background radiation levels that can vary by a factor of up to nine from site to site. Some RPM lanes have few occupancies, whereas others have up to approximately 8,000 occupancies per day, and the different types of cargo traveling through a site can result in site-wide alarm rates that range from near 0% at some sites to above 3% at others. Based on the data received, the global average uptime for NSDD RPMs was 97% for FY 2018. NSDD takes all these factors into account in making recommendations to partner countries on how to most effectively manage and maintain site operations. NSDD utilizes reports and other information products created by ORNL Radiation Inspection Systems Team (RIST) data analysts to efficiently allocate the resources needed to detect and ultimately interdict illicit nuclear and radiological material.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

IR Camera Report for the 7 Day Production Test

The following report gives a summary of the IR camera performance results and data for the 7 day production run that occurred from 10 Sep 2015 thru 16 Sep 2015. During this production run our goal was to see how well the camera performed its task of monitoring the target window temperature with our improved alignment procedure and emissivity measurements. We also wanted to see if the increased shielding would be effective in protecting the camera from damage and failure.

43 PARTICLE ACCELERATORS↗

Neutron sensitivity and detection efficiency of {sup 3}He and {sup 10}BF{sub 3} counters

An analytic relationship between the efficiency, sensitivity, and the coefficient of working-isotope utilization is established for gas-filled cylindrical thermal-neutron counters. This dependence is expressed in terms of the ratio of the characteristic length of a counter to its diameter. The characteristic size is introduced as the ratio of the total absorption cross section to the length of the counter. The parameters of basic {sup 3}He and {sup 10}BF{sub 3} counters used in NM-64 neutron monitors are calculated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear Smuggling Detection and Deterrence FY 2016 Data Analysis Annual Report

The National Nuclear Security Administration’s Office of Nuclear Smuggling Detection and Deterrence (NSDD) has facilitated the installation of more than 3,500 radiation portal monitors (RPMs) at 606 sites in 56 countries worldwide. This collection of RPMs represents the world’s largest network of radiation detectors and provides one element in the defense-in-depth approach that supports the Global Nuclear Detection Architecture. These systems support NSDD’s mission to build partner country capability to deter, detect, and interdict the illicit transport of radiological and fissile material through strategic points of entry and exit at seaports, airports, and border crossings. NSDD works collaboratively with partner countries and international organizations to optimize the operation of these RPMs. The large amount of data provided by NSDD partner countries highlights the close cooperation and partnerships NSDD has built with 56 countries around the world. Thirty-seven of these countries shared at least some RPM-related data with NSDD in fiscal year 2016. This significant level of data sharing is a key element that distinguishes the NSDD office as unique among nuclear nonproliferation programs and initiatives: NSDD can provide specific, objective, data-driven decisions and support for sustaining the radiation detection systems it helped deploy. This data analysis report summarizes and aggregates the RPM data provided to the NSDD office for analysis and review in fiscal year 2016. The data can be used to describe RPM performance and characterize the wide diversity of NSDD deployment sites. For example, NSDD deploys detector systems across sites with natural background radiation levels that can vary by a factor of approximately six from site to site. Some lanes have few occupancies, whereas others have approximately 8,000 occupancies per day and the different types of cargo that travel through a site can result in site-wide alarm rates that range from near 0% at some sites to above 3% at others. Based on the data received, the global average uptime for NSDD RPMs was above 96% for fiscal year 2016. NSDD takes all of these factors into account in making recommendations to partner countries on how to most effectively manage and maintain site operations. NSDD utilizes reports and other information products created by data analysts to efficiently allocate the resources needed to detect and ultimately interdict illicit nuclear and radiological material.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Restoration and Reexamination of Apollo Lunar Dust Detector Data from Original Telemetry Files

We are recovering the original telemetry (Figure I) from the Apollo Dust, Thermal, Radiation Environment Monitor (DTREM) experiment, more commonly known as the Dust Detector, and producing full time resolution (54 second) data sets for release through the Planetary Data System (PDS). The primary objective of the experiment was to evaluate the effect of dust deposition, temperature, and radiation damage on solar cells on the lunar surface. The monitor was a small box consisting of three solar cells and thermistors mounted on the ALSEP (Apollo Lunar Surface Experiments Package) central station. The Dust Detector was carried on Apollo's 11, 12, 14 and 15. The Apollo 11 DTREM was powered by solar cells and only operated for a few months as planned. The Apollo 12, 14, and 15 detectors operated for 5 to 7 years, returning data every 54 seconds, consisting of voltage outputs from the three solar cells and temperatures measured by the three thermistors. The telemetry was received at ground stations and held on the Apollo Housekeeping (known as "Word 33") tapes. made available to the National Space Science Data Center (NSSDC) by Yosio Nakamura (University of Texas Institute for Geophysics). We have converted selected parts of the telemetry into uncalibrated and calibrated output voltages and temperatures.

McBride, M. J.↗

Integrating and Live-time Radiation Dosimetry by Optical Crystal Damage, Initial Results with Neutrons

Radiation damage can be assessed through many techniques, though the assessment is usually offline and shows only integrated dose. Transparent crystals can be optically monitored for radiation damage nondestructively, to serve as a detector for both immediate dose and integrated dose for signatures of radiation exposure history. There is also some difference in gamma-ray and neutron interactions which can be observed. Gamma ray interactions primarily produce electron displacements, which are preserved as color centers in ionic crystals and produce specific spectral absorption lines. Neutron interactions strongly produce lattice displacements that affect the index of refraction. The differences may allow us to use inexpensive crystals for long time neutron monitoring. Spectroscopic absorption lines can be quantified using prior technology, but due to prior limits in phase sensitivity there was no previous use of index of refraction measurements. Using novel techniques based on intracavity phase interferometry to assess lattice displacements, we are able to examine neutron irradiation in CaF2 crystals. Initial results with neutrons will be presented.

99 GENERAL AND MISCELLANEOUS↗

SU-E-T-595: Output Factor Calculation for a Uniform Scanning Proton Therapy System

Purpose: To develop an analytical model that predicts dose output factors for patient treatment fields in a uniform scanning proton therapy system. Methods: A model to predict output factors for patient specific treatment fields was produced based on the methods developed by Kooy et al. (2003). The Kooy model predicts the output factor based on the ratio of the entrance dose under calibration conditions to that for a given range and modulation corrected for the inverse square effect. Field specific output factors were plotted as a function of a single parameter r, where r = (Range-Modulation)/Modulation. The model targeted user range 1 sub-span 3 through user range 2 sup-span 2 of the IBA uniform scanning proton therapy system. The data set included points measured using the 10 cm and 18 cm snout sizes to eliminate stem effects on the monitor unit chambers. The data was fit using equation 15 from Kooy et al. (2003), and the resulting model was tested against measurements that were not included in the original data set. Results: For the range and sub span investigated, 120 data points were tested against the model prediction. The model predicted the output factor within 2% for 96% of the points tested and within 2.5% for 99% of the points tested. All points were within 3% of the predicted values. Conclusion: Monitor units for patient treatment fields with proton ranges that fall within the tested interval can be predicted using a model based on the methods developed at MGH. With further evaluation, it will be possible to model all user ranges and sub-spans of the IBA system. Further testing is also needed to predict output factors using a 25 cm snout which introduces variable scanning pattern sizes and stem effects on the monitor unit chambers.

61 RADIATION PROTECTION AND DOSIMETRY↗