Search NASA⌕ Search

SEARCH · Search NASA

Results for “REFLEXES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Responses to LBNP in men with varying profiles of strength and aerobic capacity: Implications for flight crews

Hemodynamic and hormonal responses to lower-body negative pressure (LBNP) were examined in 24 healthy men to test the hypothesis that responsiveness of reflex control of blood pressure during orthostatic stress is associated with strength and/or aerobic capacity. Subjects underwent treadmill tests to determine peak oxygen uptake (peak VO2) and isokinetic dynamo meter tests to determine leg strength. Based on predetermined criteria, the subjects were classified into one of four fitness profiles of six subjects each matched for age, height, and weight: (1) low strength/low aerobic fitness; (2) low strength/high aerobic fitness; (3) high strength/low aerobic fitness; and (4) high strength/high aerobic fitness. Following 90 min of 6 degree head-down tilt (HDT), each subject underwent graded LBNP through -50 mmHg or presyncope, with maximal duration 15 min. All groups exhibited typical hemodynamic, hormonal, and fluid shift responses during LBNP, with no intergroup differences except for catecholamines. Seven subjects, distributed among the four fitness profiles, became presyncopal. Subjects who showed greatest reduction in mean arterial pressure (MAP) during LBNP had greater elevations in vasopressin and lesser increases in heart rate and peripheral resistance. Peak VO2 nor leg strength were correlated with fall in MAP or with syncopal episodes. We conclude that neither aerobic nor strength fitness characteristics are good predictors of responses to LBNP stress.

Convertino, Victor A.↗

Determination of thermal properties of commercial Ni-MH cells

The test objectives were to evaluate the electrical and thermal performance of commercial Ni-MH cells, evaluate the effectiveness of commercial charge control circuits, assess the abuse tolerance of these cells, and correlate performance and abuse tolerances to cell design via disassembly. Design objectives were to determine which cell designs are most suitable for scale-up and to guide the design of future shuttle and space station based battery chargers. Results, displayed in viewgraph format, include: reflex charging with ICS circuit resulted in premature charge termination; Ni-MH cells appear very tolerant to overcharge at low rates; Enstore's charger is more electrically and thermally efficient at high rates; and Ni-MH cycles much more efficiently than Ni-Cd with the delta-V/delta-t termination.

Darcy, Eric C.↗

Aerobic fitness and orthostatic tolerance: Evidence against an association

This presentation will focus on only one side of the debate as to whether high levels of aerobic fitness have a deleterious effect on tolerance to gravitational stress. This issue was raised in the early 1970's as a result of two research publications. The first work investigated the carotid sinus baroreflex of humans with an airtight chamber that surrounded the head and neck. The steady-state reflex changes in blood pressure that were recorded 3 minutes after application of the head and neck stimuli, were attenuated in an athletic group compared to a sedentary group of volunteers. A second report in the NASA literature indicated that five endurance-trained runners were less tolerant to LBNP than five nonrunners. These early research findings have stimulated a considerable amount of interest that has lead to a growing number of research efforts seeking an association between aerobic fitness and orthostatic tolerance in humans. I will briefly review some of the more pertinent published research information which suggests that there is no relationship between aerobic fitness and orthostatic tolerance in humans.

Ebert, Thomas J.↗

Navigation of military and space unmanned ground vehicles in unstructured terrains

Development of unmanned vehicles for local navigation in terrains unstructured by humans is reviewed. Modes of navigation include teleoperation or remote control, computer assisted remote driving (CARD), and semiautonomous navigation (SAN). A first implementation of a CARD system was successfully tested using the Robotic Technology Test Vehicle developed by Jet Propulsion Laboratory. Stereo pictures were transmitted to a remotely located human operator, who performed the sensing, perception, and planning functions of navigation. A computer provided range and angle measurements and the path plan was transmitted to the vehicle which autonomously executed the path. This implementation is to be enhanced by providing passive stereo vision and a reflex control system for autonomously stopping the vehicle if blocked by an obstacle. SAN achievements include implementation of a navigation testbed on a six wheel, three-body articulated rover vehicle, development of SAN algorithms and code, integration of SAN software onto the vehicle, and a successful feasibility demonstration that represents a step forward towards the technology required for long-range exploration of the lunar or Martian surface. The vehicle includes a passive stereo vision system with real-time area-based stereo image correlation, a terrain matcher, a path planner, and a path execution planner.

Lescoe, Paul↗

Response to graded Lower Body Negative Pressure (LBNP) after space flight

The effects of space flight on orthostatic function were studied. LBNP tests (0 to -60 mmHg) were administered to 7 crew members preflight and 2 to 6 hrs after 6 to 9 day shuttle missions. Cardiac stroke volumes were obtained each minute by echo Doppler. Orthostatic responses are given. The data suggest a decline in postflight orthostatic function, as assessed by LBNP, due to reduced cardiac filling despite potentiated heart rate and vasoconstrictor reflex responses in most crew members.

Fortney, S.↗

Extended duration orbiter medical project variability of blood pressure and heart rate (STS-50/USML-1)

Decreases in arterial baroreflex function after space flight may be related to changes in blood pressure and heart rate patterns during flight. Ambulatory blood pressure and heart rate were measured for 24 hours, in fourteen astronauts on two occasions before flight, two to three occasions in flight, and 2 days after landing on Shuttle missions lasting 4 to 14 days. Blood pressure and heart rate were recorded every 20minutes during awake periods and every 30 minutes during sleep. In pre- and postflight studies, the 24-hour ambulatory measurements were followed by studies of carotid baroreceptor-cardiac reflex responses. Carotid baroreceptors were stimulated using a sequence of neck pressure and suction from +40 to -65 mmHg.

Fritsch-Yelle, Janice M.↗

STS-70 Flight: Day 3

The third day of the STS-70 mission of Space Shuttle Discovery is contained on this video. Astronauts Kregel and Thomas begin the day by working with the Hercules camera, which will record pinpoint data on the surface location of Earth observation imagery. Other work includes operations with an experiment that gauges astronauts' reflexes and hand-eye coordination. During the day, the crew spoke with World War 2 veteran, Harland Claussen, and ABC's Mike and Maty Show and the Toledo Blade newspaper (Toledo, Ohio) interviewed the astronauts via satellite link.

Source record↗

Stellar kinematics in the nucleus of NGC 6240: A massive galaxy revealed

We have used the 2.3 micron bandhead of CO to measure the kinematics of the red stellar population in the nucleus of the luminous galaxy NGC 6240, the near-infrared spectrum of which is dominated by lines of shocked gas. With this manifest evidence for dissipative effects in the gas, it is such stellar velocity dispersion that is most unambiguously indicative of gravitational potential. We find a nuclear velocity dispersion sigma = 350 km/sec which is considerably larger than that seen in any gaseous component of this galaxy. At least one partner in this merger must therefore have been very massive, with M(sub B) approximately -23. In view of conventional wisdom that the high luminosity of NGC 6240 derives from star formation, it is suprising that we find M/L to be of order unity. While there seems to be little question that star formation is taking place in this interacting system, this high M/L calls into question the importance of star formation in the luminosity budget of the galaxy. In particular, it seems likely that the red starlight in NGC 6240 is produced by giants rather than a population of young red supergiants. This brings into question the (now reflexive) association of relatively deep CO bands in galaxies (which are conspicuously strong in NGC 6240) with recent star formation.

Lester, Dan F.↗

Effect of water temperature on diuresis-natriuresis: AVP, ANP, and urodilatin during immersion in men

Effects of water temperature on diuresis, natriuresis, and associated endocrine responses during head-out immersion were studied in eight men during four 5-h experimental conditions: air control at 28 C and immersion at 34.5 C (thermoneutral (Tnt)), 36 C (above Tnt (aTnt)), and 32 C (below Tnt (bTnt). Esophageal temperature decreased by approximately 0.4 C in bTnt and increased by approximately 0.5 C in aTnt. Cardiac output increased by approximately 80% in aTnt and approximately 40% in bTnt while thoracic impedance, an index of central blood pooling, decreased by 7.5 ohms in bTnt (NS vs. Tnt) and 8.8 ohms in aTnt. Total peripheral resistance decreased at all temperatures (50% in aTnt, 20% in bTnt). Urine flow and Na(+) excretion increased by sixfold in bTnt and Tnt but by only threefold in aTnt. Creatinine clearance was unchanged while osmolal clearance (but not free water clearance) increased two-fold with all immersions. Plasma atrial natriuretic peptide (ANP), urinary urodilatin, and urinary guanosine 3',5'-cyclic monophosphate increased while plasma renin activity, aldosterone, and arginine vasopressin (AVP) decreased similarly at all temperatures. bTnt did not potentiate diuresis by selective attenuation of AVP. The overall natriuretic response exhibited a higher correlation with urodilatin than with ANP. Because diuresis and natriuresis were significantly attenuated in aTnt where central blood pooling was greater, we conclude that mechanisms other than the atrial stretch receptor reflex, i.e., urodilatin and effective arterial blood volume, may play more predominant roles in the mechanism of immersion-induced diuresis and natriuresis.

Nakamitsu, S.↗

Telerobot local-remote control architecture for space flight program applications

The JPL Supervisory Telerobotics (STELER) Laboratory has developed and demonstrated a unique local-remote robot control architecture which enables management of intermittent communication bus latencies and delays such as those expected for ground-remote operation of Space Station robotic systems via the Tracking and Data Relay Satellite System (TDRSS) communication platform. The current work at JPL in this area has focused on enhancing the technologies and transferring the control architecture to hardware and software environments which are more compatible with projected ground and space operational environments. At the local site, the operator updates the remote worksite model using stereo video and a model overlay/fitting algorithm which outputs the location and orientation of the object in free space. That information is relayed to the robot User Macro Interface (UMI) to enable programming of the robot control macros. This capability runs on a single Silicon Graphics Inc. machine. The operator can employ either manual teleoperation, shared control, or supervised autonomous control to manipulate the intended object. The remote site controller, called the Modular Telerobot Task Execution System (MOTES), runs in a multi-processor VME environment and performs the task sequencing, task execution, trajectory generation, closed loop force/torque control, task parameter monitoring, and reflex action. This paper describes the new STELER architecture implementation, and also documents the results of the recent autonomous docking task execution using the local site and MOTES.

Zimmerman, Wayne↗

The effect of space flight on spatial orientation

Both during and following early space missions, little neurosensory change in the astronauts was noted as a result of their exposure to microgravity. It is believed that this lack of in-flight adaptation in the spatial orientation and perceptual-motor system resulted from short exposure times and limited interaction with the new environment. Parker and Parker (1990) have suggested that while spatial orientation and motion information can be detected by a passive observer, adaptation to stimulus rearrangement is greatly enhanced when the observer moves through or acts on the environment. Experience with the actual consequences of action can be compared with those consequences expected on the basis of prior experience. Space flight today is of longer duration, and space craft volume has increased. These changes have forced the astronauts to interact with the new environment of microgravity, and as a result substantial changes occur in the perceptual and sensory-motor repsonses reflecting adaptation to the stimulus rearrangement of space flight. We are currently evaluating spatial orientation and the perceptual-motor systems' adaptation to microgravity by examining responses of postural control, head and gaze stability during locomotion, goal oriented vestibulo-ocular reflex (VOR), and structured quantitative perceptual reports. Evidence suggests that humans can successfully replace the gravitational reference available on Earth with cues available within the spacecraft or within themselves, but that adaptation to microgravity is not appropriate for a return to Earth. Countermeasures for optimal performance on-orbit and a successful return to earth will require development of preflight and in-flight training to help the astronauts acquire and maintain a dual adaptive state. An understanding of spatial orientation and motion perception, postural control, locomotion, and the VOR will aid in this process.

Reschke, Millard F.↗

Development and implementation of Inflight Neurosensory Training for Adaptation/Readaptation (INSTAR)

Resolution of space motion sickness, and improvements in spatial orientation, posture and motion control, and compensatory eye movements occur as a function of neurosensory and sensorimotor adaptation to microgravity. These adaptive responses, however, are inappropriate for return to Earth. Even following relatively brief space Shuttle missions, significant re-adaptation disturbances related to visual performance, locomotion, and perceived self-motion have been observed. Russian reports suggest that these disturbances increase with mission duration and may be severe following landing after prolonged microgravity exposure such as during a voyage to Mars. Consequently, there is a need to enable the astronauts to be prepared for and more quickly re-adapt to a gravitational environment following extended space missions. Several devices to meet this need are proposed including a virtual environment - centrifuge device (VECD). A short-arm centrifuge will provide centripetal acceleration parallel to the astronaut's longitudinal body axis and a restraint system will be configured to permit head movements only in the plane of rotation (to prevent 'cross-coupling'). A head-mounted virtual environment system will be used to develop appropriate 'calibration' between visual motion/orientation signals and inertial motion/orientation signals generated by the centrifuge. This will permit vestibular, visual and somatosensory signal matches to bias central interpretation of otolith signals toward the 'position' responses and to recalibrate the vestibulo-ocular reflex (VOR).

Harm, D. L.↗

Adaptation of Baroreflexes and Orthostatic Hypotension

The footward shift of blood volume and compensatory autonomic reflex responses initiated during the assumption of the upright posture in terrestrial gravity is a common feature in humans. When regular exposure to upright posture is removed, the headward redistribution of blood induces numerous physiological adaptations which compromise this normal response and the development of low blood pressure upon standing (orthostatic hypotension) can ensue. Such microgravity conditions can be produced by prolonged exposure to spaceflight or prolonged bed rest. Since the reduction of blood and plasma volume during exposure to microgravity has been associated with orthostatic instability following spaceflight and bed rest, it has been a reasonable assumption that hypovolemia may be a primary contributing factor to the development of orthostatic hypotension. This view was supported by the observation that the attempt to restore vascular volume in astronauts by drinking saline solutions just prior to re-entry had proven effective in reducing orthostatic instability after spaceflights of short duration. However, as the duration of spaceflight lengthens, orthostatic instability persists despite fluid loading procedures, suggesting that mechanisms other than hypovolemia may contribute to orthostatic hypotension following prolonged exposure to microgravity conditions. Recent evidence has been generated from spaceflight and groundbase experiments that supports the notion that changes in autonomic baroreflexes that control cardiac and vascular responses during orthostatic challenges may be affected by longer periods of microgravity exposure and can contribute to postflight orthostatic instability.

Convertino, Victor A.↗

Baroreflex Responses to Acute Changes in Blood Volume in Humans

To test the hypothesis that acute changes in plasma volume affect the stimulus-response relations of high- and low- pressure baroreflexes, eight men (27-44 yr old) underwent measurements for carotid-cardiac and cardiopulmonary baro- reflex responses under the following three volemic conditions: hypovolemic, normovolemic, and hypervolemic. The stimulus- response relation of the carotid-cardiac response curve was generated using a neck cuff device, which delivered pressure changes between +40 and -65 mmHg in continuous steps of 15 mmHg. The stimulus-response relationships of the cardiopulmonary baroreflex were studied by measurements of Forearm Vascular Resistance (FVR) and Peripheral Venotis Pressure (PVP) during low levels of lower body negative pressure (O to -20 mmHg). Altered vascular volume had no effect on response relations of the carotid-cardiac baroreflex but did alter the gain of the cardiopulmonary baroreflex (-7.93 q 1.71, -4.36 q 1.38, and -2.56 q 1.59 peripheral resistance units/mmHg for hypovolemic, normovolemic, and hypervolemic, respectively) independent of shifts in baseline FVR and PVP. These results indicate greater demand for vasoconstriction for equal reductions in venous pressure during progressive hypovolemia; this condition may compromise the capacity to provide adequate peripheral resistance during severe orthostatic stress. Fluid loading before reentry after spaceflight may act to restore vasoconstrictive capacity of the cardiopulnionary baroreflex but may not be an effective countermeasure against potential post- flight impairment of the carotid-cardiac baroreflex.

Thompson, Cynthia A.↗

An Investigation of Horizontal Combined Eye-Head Tracking in Patients with Abnormal Vestibular and Smooth Pursuit Eye Movements

We investigated the interaction of smooth ocular pursuit (SP) and the vestibulo-ocular reflex (VOR) during horizontal, combined eye-head tracking (CEHT) in patients with abnormalities of either the VOR or SP movements. Our strategy was to apply transient stimuli that capitalized on the different latencies to onset of SP and the VOR. During CEHT of a target moving at 15 deg/sec, normal subjects and patients with VOR deficits all tracked the target with a gain close to 1.O. When the heads of normal subjects were suddenly and unexpectedly braked to a halt during CEHT, the eye promptly began to move in the orbit to track the target, but eye-in-orbit velocity transiently fell to about 60-70% of target velocity. In patients with deficient labyrinthine function, following the onset of the head brake, eye movements to track the target were absent, and SP movements were not generated until about 100 msec later. In patients with deficient SP, CEHT was superior to SP tracking with the head stationary; after the onset of the head brake, tracking eye movements were initiated promptly, but eye velocity was less than 50% of target velocity and increased only slightly thereafter. These results indicate that at least two mechanisms operate to overcome the VOR and allow gaze to track the target during CEHT: (1) the SP system provides a signal to cancel a normally-operating VOR (this cancellation signal is not needed by labyrinthine-deficient patients who have no VOR to cancel), and (2) a reduction of the gain of the VOR is achieved, an ability that is preserved even in patients with cerebral lesions that impair SP.

Huebner, William P.↗

Baroreflex Responses to Acute Changes in Blood Volume in Humans

To test the hypothesis that acute changes in plasma volume affect the stimulus-response relations of high- and low- pressure baroreflexes, eight men (27-44 yr old) underwent measurements for carotid-cardiac and cardiopulmonary baro-reflex responses under the following three volemic conditions: hypovolemic, normovolemic, and hypervolemic. The stimulus- response relation of the carotid-cardiac response curve was generated using a neck cuff device, which delivered pressure changes between +40 and -65 mmHg in continuous steps of 15 mmHg. The stimulus-response relationship, of the cardio-pulmonary baroreflex were studied by measurements of Forearm Vascular Resistance (FVR) and Peripheral Venous Pressure (PVP) during low levels of lower body negative pressure (O to -20 mmHg). The results indicate greater demand for vasoconstriction for equal reductions in venous pressure during progressive hypovolemia; this condition may compromise the capacity to provide adequate peripheral resistance during severe orthostatic stress. Fluid loading before reentry after spaceflight may act to restore vasoconstrictive capacity of the cardiopulmonary baroreflex but may not be an effective countermeasure against potential post- flight impairment of the carotid-cardiac baroreflex.

Thompson, Cynthia A.↗

Visual Vestibular Interaction in the Dynamic Visual Acuity Test during Voluntary Head Rotation

Although intact vestibular function is essential in maintaining spatial orientation, no good screening tests of vestibular function are available to the aviation community. High frequency voluntary head rotation was selected as a vestibular stimulus to isolate the vestibulo-ocular reflex (VOR) from visual influence. A dynamic visual acuity test that incorporates voluntary head rotation was evaluated as a potential vestibular function screening tool. Twenty-seven normal subjects performed voluntary sinusoidal head rotation at frequencies from 0.7-4.0 Hz under three different visual conditions: visually-enhanced VOR, normal VOR, and visually suppressed VOR. Standardized Baily-Lovie chart letters were presented on a computer monitor in front of the subject, who then was asked to read the letters while rotating his head horizontally. The electro-oculogram and dynamic visual acuity score were recorded and analyzed. There were no significant differences in gain or phase shift among three visual conditions in the frequency range of 2.8 to 4.0 Hz. The dynamic visual acuity score shifted less than 0.3 logMAR at frequencies under 2.0 Hz. The dynamic visual acuity test at frequencies a round 2.0 Hz can be recommended for evaluating vestibular function.

VISUAL ACUITY↗

Comparison of Predictable Smooth Ocular and Combined Eye-Head Tracking Behaviour in Patients with Lesions Affecting the Brainstem and Cerebellum

We compared the ability of eight normal subjects and 15 patients with brainstem or cerebellar disease to follow a moving visual stimulus smoothly with either the eyes alone or with combined eye-head tracking. The visual stimulus was either a laser spot (horizontal and vertical planes) or a large rotating disc (torsional plane), which moved at one sinusoidal frequency for each subject. The visually enhanced Vestibulo-Ocular Reflex (VOR) was also measured in each plane. In the horizontal and vertical planes, we found that if tracking gain (gaze velocity/target velocity) for smooth pursuit was close to 1, the gain of combined eye-hand tracking was similar. If the tracking gain during smooth pursuit was less than about 0.7, combined eye-head tracking was usually superior. Most patients, irrespective of diagnosis, showed combined eye-head tracking that was superior to smooth pursuit; only two patients showed the converse. In the torsional plane, in which optokinetic responses were weak, combined eye-head tracking was much superior, and this was the case in both subjects and patients. We found that a linear model, in which an internal ocular tracking signal cancelled the VOR, could account for our findings in most normal subjects in the horizontal and vertical planes, but not in the torsional plane. The model failed to account for tracking behaviour in most patients in any plane, and suggested that the brain may use additional mechanisms to reduce the internal gain of the VOR during combined eye-head tracking. Our results confirm that certain patients who show impairment of smooth-pursuit eye movements preserve their ability to smoothly track a moving target with combined eye-head tracking.

Grant, Michael P.↗