Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reconstruction algorithms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

PlantSEED enables automated annotation and reconstruction of plant primary metabolism with improved compartmentalization and comparative consistency

Genome-scale metabolic reconstructions help us to understand and engineer metabolism. Next-generation sequencing technologies are delivering genomes and transcriptomes for an ever-widening range of plants. While such omic data can, in principle, be used to compare metabolic reconstructions in different species, organs and environmental conditions, these comparisons require a standardized framework for the reconstruction of metabolic networks from transcript data. We previously introduced PlantSEED as a framework covering primary metabolism for 10 species. We have now expanded PlantSEED to include 39 species and provide tools that enable automated annotation and metabolic reconstruction from transcriptome data. The algorithm for automated annotation in PlantSEED propagates annotations using a set of signature k-mers (short amino acid sequences characteristic of particular proteins) that identify metabolic enzymes with an accuracy of about 97%. PlantSEED reconstructions are built from a curated template that includes consistent compartmentalization for more than 100 primary metabolic subsystems. Together, the annotation and reconstruction algorithms produce reconstructions without gaps and with more accurate compartmentalization than existing resources. These tools are available via the PlantSEED web interface at , which enables users to upload, annotate and reconstruct from private transcript data and simulate metabolic activity under various conditions using flux balance analysis. We demonstrate the ability to compare these metabolic reconstructions with a case study involving growth on several nitrogen sources in roots of four species.

Flux Balance Analysis↗

Neutrino interaction vertex reconstruction in DUNE with Pandora deep learning

The Pandora Software Development Kit and algorithm libraries perform reconstruction of neutrino interactions in liquid argon time projection chamber detectors. Pandora is the primary event reconstruction software used at the Deep Underground Neutrino Experiment, which will operate four large-scale liquid argon time projection chambers at the far detector site in South Dakota, producing high-resolution images of charged particles emerging from neutrino interactions. While these high-resolution images provide excellent opportunities for physics, the complex topologies require sophisticated pattern recognition capabilities to interpret signals from the detectors as physically meaningful objects that form the inputs to physics analyses. A critical component is the identification of the neutrino interaction vertex. Subsequent reconstruction algorithms use this location to identify the individual primary particles and ensure they each result in a separate reconstructed particle. A new vertex-finding procedure described in this article integrates a U-ResNet neural network performing hit-level classification into the multi-algorithm approach used by Pandora to identify the neutrino interaction vertex. The machine learning solution is seamlessly integrated into a chain of pattern-recognition algorithms. The technique substantially outperforms the previous BDT-based solution, with a more than 20% increase in the efficiency of sub-1 cm vertex reconstruction across all neutrino flavours.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-F-T-441: Dose Calculation Accuracy in CT Images Reconstructed with Artifact Reduction Algorithm

Purpose: Accuracy of radiotherapy dose calculation in patients with surgical implants is complicated by two factors. First is the accuracy of CT number, second is the dose calculation accuracy. We compared measured dose with dose calculated on CT images reconstructed with FBP and an artifact reduction algorithm (OMAR, Philips) for a phantom with high density inserts. Dose calculation were done with Varian AAA and AcurosXB. Methods: A phantom was constructed with solid water in which 2 titanium or stainless steel rods could be inserted. The phantom was scanned with the Philips Brillance Big Bore CT. Image reconstruction was done with FBP and OMAR. Two 6 MV single field photon plans were constructed for each phantom. Radiochromic films were placed at different locations to measure the dose deposited. One plan has normal incidence on the titanium/steel rods. In the second plan, the beam is at almost glancing incidence on the metal rods. Measurements were then compared with dose calculated with AAA and AcurosXB. Results: The use of OMAR images slightly improved the dose calculation accuracy. The agreement between measured and calculated dose was best with AXB and image reconstructed with OMAR. Dose calculated on titanium phantom has better agreement with measurement. Large discrepancies were seen at points directly above and below the high density inserts. Both AAA and AXB underestimated the dose directly above the metal surface, while overestimated the dose below the metal surface. Doses measured downstream of metal were all within 3% of calculated values. Conclusion: When doing treatment planning for patients with metal implants, care must be taken to acquire correct CT images to improve dose calculation accuracy. Moreover, great discrepancies in measured and calculated dose were observed at metal/tissue interface. Care must be taken in estimating the dose in critical structures that come into contact with metals.

60 APPLIED LIFE SCIENCES↗

MO-G-17A-07: Improved Image Quality in Brain F-18 FDG PET Using Penalized-Likelihood Image Reconstruction Via a Generalized Preconditioned Alternating Projection Algorithm: The First Patient Results

Purpose: To investigate the performance of a new penalized-likelihood PET image reconstruction algorithm using the 1{sub 1}-norm total-variation (TV) sum of the 1st through 4th-order gradients as the penalty. Simulated and brain patient data sets were analyzed. Methods: This work represents an extension of the preconditioned alternating projection algorithm (PAPA) for emission-computed tomography. In this new generalized algorithm (GPAPA), the penalty term is expanded to allow multiple components, in this case the sum of the 1st to 4th order gradients, to reduce artificial piece-wise constant regions (“staircase” artifacts typical for TV) seen in PAPA images penalized with only the 1st order gradient. Simulated data were used to test for “staircase” artifacts and to optimize the penalty hyper-parameter in the root-mean-squared error (RMSE) sense. Patient FDG brain scans were acquired on a GE D690 PET/CT (370 MBq at 1-hour post-injection for 10 minutes) in time-of-flight mode and in all cases were reconstructed using resolution recovery projectors. GPAPA images were compared PAPA and RMSE-optimally filtered OSEM (fully converged) in simulations and to clinical OSEM reconstructions (3 iterations, 32 subsets) with 2.6 mm XYGaussian and standard 3-point axial smoothing post-filters. Results: The results from the simulated data show a significant reduction in the 'staircase' artifact for GPAPA compared to PAPA and lower RMSE (up to 35%) compared to optimally filtered OSEM. A simple power-law relationship between the RMSE-optimal hyper-parameters and the noise equivalent counts (NEC) per voxel is revealed. Qualitatively, the patient images appear much sharper and with less noise than standard clinical images. The convergence rate is similar to OSEM. Conclusions: GPAPA reconstructions using the 1{sub 1}-norm total-variation sum of the 1st through 4th-order gradients as the penalty show great promise for the improvement of image quality over that currently achieved with clinical OSEM reconstructions.

60 APPLIED LIFE SCIENCES↗

GPU-based fast cone beam CT reconstruction from undersampled and noisy projection data via total variation

Purpose: Cone-beam CT (CBCT) plays an important role in image guided radiation therapy (IGRT). However, the large radiation dose from serial CBCT scans in most IGRT procedures raises a clinical concern, especially for pediatric patients who are essentially excluded from receiving IGRT for this reason. The goal of this work is to develop a fast GPU-based algorithm to reconstruct CBCT from undersampled and noisy projection data so as to lower the imaging dose. Methods: The CBCT is reconstructed by minimizing an energy functional consisting of a data fidelity term and a total variation regularization term. The authors developed a GPU-friendly version of the forward-backward splitting algorithm to solve this model. A multigrid technique is also employed. Results: It is found that 20-40 x-ray projections are sufficient to reconstruct images with satisfactory quality for IGRT. The reconstruction time ranges from 77 to 130 s on an NVIDIA Tesla C1060 (NVIDIA, Santa Clara, CA) GPU card, depending on the number of projections used, which is estimated about 100 times faster than similar iterative reconstruction approaches. Moreover, phantom studies indicate that the algorithm enables the CBCT to be reconstructed under a scanning protocol with as low as 0.1 mA s/projection. Comparing with currently widely used full-fan head and neck scanning protocol of {approx}360 projections with 0.4 mA s/projection, it is estimated that an overall 36-72 times dose reduction has been achieved in our fast CBCT reconstruction algorithm. Conclusions: This work indicates that the developed GPU-based CBCT reconstruction algorithm is capable of lowering imaging dose considerably. The high computation efficiency in this algorithm makes the iterative CBCT reconstruction approach applicable in real clinical environments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

FIRM: federated image reconstruction using multimodal tomographic data

Here, we propose a federated algorithm for reconstructing images using multimodal tomographic data sourced from dispersed locations, addressing the challenges of traditional unimodal approaches that are prone to noise and reduced image quality, as well as the limitations of centralized multimodal approaches that require extensive data transfer, leading to significant communication overhead, storage demands, and potential data privacy concerns. Our approach formulates a joint inverse optimization problem incorporating multimodality constraints and solves it in a federated framework through local gradient computations complemented by lightweight central operations, thereby ensuring data decentralization. Leveraging the connection between our federated algorithm and the quadratic penalty method, we introduce an adaptive step-size rule with guaranteed sublinear convergence. Numerical results demonstrate superior computational efficiency and improved image reconstruction quality compared to existing approaches.

federated algorithm↗

Molecular Assemblies, Genes and Genomics Integrated Efficiently (MAGGIE)

Final report on MAGGIE. We set ambitious goals to model the functions of individual organisms and their community from molecular to systems scale. These scientific goals are driving the development of sophisticated algorithms to analyze large amounts of experimental measurements made using high throughput technologies to explain and predict how the environment influences biological function at multiple scales and how the microbial systems in turn modify the environment. By experimentally evaluating predictions made using these models we will test the degree to which our quantitative multiscale understanding wilt help to rationally steer individual microbes and their communities towards specific tasks. Towards this end we have made substantial progress towards understanding evolution of gene families, transcriptional structures, detailed structures of keystone molecular assemblies (proteins and complexes), protein interactions, biological networks, microbial interactions, and community structure. Using comparative analysis we have tracked the evolutionary history of gene functions to understand how novel functions evolve. One level up, we have used proteomics data, high-resolution genome tiling microarrays, and 5' RNA sequencing to revise genome annotations, discover new genes including ncRNAs, and map dynamically changing operon structures of five model organisms: For Desulfovibrio vulgaris Hildenborough, Pyrococcus furiosis, Sulfolobus solfataricus, Methanococcus maripaludis and Haiobacterium salinarum NROL We have developed machine learning algorithms to accurately identify protein interactions at a near-zero false positive rate from noisy data generated using tagfess complex purification, TAP purification, and analysis of membrane complexes. Combining other genome-scale datasets produced by ENIGMA (in particular, microarray data) and available from literature we have been able to achieve a true positive rate as high as 65% at almost zero false positives when applied to the manually curated training set. Applying this method to the data representing around a quarter of the fraction space for water soluble proteins in D. vulgaris, we obtained 854 reliable pair wise interactions. Further, we have developed algorithms to analyze and assign significance to protein interaction data from bait pull-down experiments and integrate these data with other systems biology data through associative biclustering in a parallel computing environment. We will 'fill-in' missing information in these interaction data using a 'Transitive Closure' algorithm and subsequently use 'Between Commonality Decomposition' algorithm to discover complexes within these large graphs of protein interactions. To characterize the metabolic activities of proteins and their complexes we are developing algorithms to deconvolute pure mass spectra, estimate chemical formula for m/z values, and fit isotopic fine structure to metabolomics data. We have discovered that in comparison to isotopic pattern fitting methods restricting the chemical formula by these two dimensions actually facilitates unique solutions for chemical formula generators. To understand how microbial functions are regulated we have developed complementary algorithms for reconstructing gene regulatory networks (GRNs). Whereas the network inference algorithms cMonkey and Inferelator developed enable de novo reconstruction of predictive models for GRNs from diverse systems biology data, the RegPrecise and RegPredict framework developed uses evolutionary comparisons of genomes from closely related organisms to reconstruct conserved regulons. We have integrated the two complementary algorithms to rapidly generate comprehensive models for gene regulation of understudied organisms. Our preliminary analyses of these reconstructed GRNs have revealed novel regulatory mechanisms and cis-regulatory motifs, as well asothers that are conserved across species. Finally, we are supporting scientific efforts in ENIGMA with data management solutions and by integrating all of the algorithms, software and data into a Knowledgebase. For instance, we have developed the RegPrecise database (http://regprecise.lbl.gov) which represents manually curated sets of regulons laying the basis for automatic annotation of regulatory interactions in closely related species. We are also in the midst of scaling up MicrobesOnline to handle the growing volume of sequence and functional genomics data. Over the last year our efforts have been focused on providing support for additional genomic and functional genomic data types. Similarly, we have developed several visualization tools to help with the exploration of complex systems biology datasets. A case in point is the Gaggle Genome Browser (GGB), which was enhanced with visualizations for plotting peptide detections and protein-DNA binding alongside transcriptome structure, plus the ability to interactively filter by signal intensity or p-value.

54 ENVIRONMENTAL SCIENCES↗

Automating Anomaly Detection for Target systems at Spallation Neutron Source

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory, produces the world’s most intense pulse neutrons beams. An accelerated proton beam is directed into a mercury target to generate neutrons via spallation. The target system accounted for over 40% of the overall downtime of the facility in 2022. Thus, early detection in anomalies in the target systems can enable taking corrective actions to avoid failures and reduce downtime. Fault prognostics and anomaly detection in accelerators, both at SNS and outside, has largely focused on the beam side. This paper presents one the first studies exploring leveraging machine learning to automate the detection of anomalies in the target system. The target system consists of over 30 different interconnected subsystems, and the present work focuses on the mercury process system as a use case. Analyzing data from 28 process variables from 2022 and 2023, tree-based and reconstruction-based algorithms are employed to detect anomalies in archived data. The algorithms detected previously unreported anomalies, several of which were deemed alert worthy by human experts, particularly those found by reconstruction-based algorithms. Using data from each production run in the accelerator increased the generalizability of the models in time. Efforts are now underway to implement a workflow for incorporating human feedback to update the models and evaluating performance on unseen data. The models will eventually be integrated into the existing System Tracking and Reliability system with a web interface for automated anomaly detection and reporting along with a pathway for incorporating human feedback for model updates.

Raj, Anant [ORNL] (ORCID:0000000306711244)↗

First-order convex feasibility algorithms for x-ray CT

Purpose: Iterative image reconstruction (IIR) algorithms in computed tomography (CT) are based on algorithms for solving a particular optimization problem. Design of the IIR algorithm, therefore, is aided by knowledge of the solution to the optimization problem on which it is based. Often times, however, it is impractical to achieve accurate solution to the optimization of interest, which complicates design of IIR algorithms. This issue is particularly acute for CT with a limited angular-range scan, which leads to poorly conditioned system matrices and difficult to solve optimization problems. In this paper, we develop IIR algorithms which solve a certain type of optimization called convex feasibility. The convex feasibility approach can provide alternatives to unconstrained optimization approaches and at the same time allow for rapidly convergent algorithms for their solution-thereby facilitating the IIR algorithm design process. Methods: An accelerated version of the Chambolle-Pock (CP) algorithm is adapted to various convex feasibility problems of potential interest to IIR in CT. One of the proposed problems is seen to be equivalent to least-squares minimization, and two other problems provide alternatives to penalized, least-squares minimization. Results: The accelerated CP algorithms are demonstrated on a simulation of circular fan-beam CT with a limited scanning arc of 144 Degree-Sign . The CP algorithms are seen in the empirical results to converge to the solution of their respective convex feasibility problems. Conclusions: Formulation of convex feasibility problems can provide a useful alternative to unconstrained optimization when designing IIR algorithms for CT. The approach is amenable to recent methods for accelerating first-order algorithms which may be particularly useful for CT with limited angular-range scanning. The present paper demonstrates the methodology, and future work will illustrate its utility in actual CT application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron efficiency measurements with the ATLAS detector using 2012 LHC proton–proton collision data

This paper describes the algorithms for the reconstruction and identification of electrons in the central region of the ATLAS detector at the Large Hadron Collider (LHC). These algorithms were used for all ATLAS results with electrons in the final state that are based on the 2012 pp collision data produced by the LHC at s = 8 TeV. The efficiency of these algorithms, together with the charge misidentification rate, is measured in data and evaluated in simulated samples using electrons from Z→ ee, Z→ eeγ and J/ ψ→ ee decays. For these efficiency measurements, the full recorded data set, corresponding to an integrated luminosity of 20.3 fb - 1 , is used. Based on a new reconstruction algorithm used in 2012, the electron reconstruction efficiency is 97% for electrons with E T = 15 GeV and 99% at E T = 50 GeV. Combining this with the efficiency of additional selection criteria to reject electrons from background processes or misidentified hadrons, the efficiency to reconstruct and identify electrons at the ATLAS experiment varies from 65 to 95%, depending on the transverse momentum of the electron and background rejection.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Test of 3D CT reconstructions by EM + TV algorithm from undersampled data

Computerized tomography (CT) plays an important role in medical imaging for diagnosis and therapy. However, CT imaging is connected with ionization radiation exposure of patients. Therefore, the dose reduction is an essential issue in CT. In 2011, the Expectation Maximization and Total Variation Based Model for CT Reconstruction (EM+TV) was proposed. This method can reconstruct a better image using less CT projections in comparison with the usual filtered back projection (FBP) technique. Thus, it could significantly reduce the overall dose of radiation in CT. This work reports the results of an independent numerical simulation for cone beam CT geometry with alternative virtual phantoms. As in the original report, the 3D CT images of 128 Multiplication-Sign 128 Multiplication-Sign 128 virtual phantoms were reconstructed. It was not possible to implement phantoms with lager dimensions because of the slowness of code execution even by the CORE i7 CPU.

61 RADIATION PROTECTION AND DOSIMETRY↗

Reconstructing the Position and Intensity of Multiple Gamma-Ray Point Sources with a Sparse Parametric Algorithm

IEEE We present an experimental demonstration of Additive Point Source Localization (APSL), a sparse parametric imaging algorithm that reconstructs the 3D positions and activities of multiple gamma-ray point sources. Using a handheld gamma-ray detector array and up to four 8 μCi 137 Cs gamma-ray sources, we performed both source-search and source-separation experiments in an indoor laboratory environment. In the majority of the source-search measurements, APSL reconstructed the correct number of sources with position accuracies of ~20 cm and activity accuracies (unsigned) of ~20%, given measurement times of two to three minutes and distances of closest approach (to any source) of ~20 cm. In source-separation measurements where the detector could be moved freely about the environment, APSL was able to resolve two sources separated by 75 cm or more given only ~60 s of measurement time. In these source-separation measurements, APSL produced larger total activity errors of ~40%, but obtained source separation distances accurate to within 15 cm. We also compare our APSL results against traditional Maximum Likelihood-Expectation Maximization (ML-EM) reconstructions, and demonstrate improved image accuracy and interpretability using APSL over ML-EM. These results indicate that APSL is capable of accurately reconstructing gamma-ray source positions and activities using measurements from existing detector hardware.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Simultaneous sample and spatial coherence characterisation using diffractive imaging

We demonstrate an algorithm that reconstructs the complex transmission function of an object from experimental X-ray diffraction data using partially coherent 1.4 keV X-rays that does not require a priori input of the coherence function. The quality of the reconstruction is significantly better than that obtained by assuming that the illumination is fully coherent. Our approach can be readily applied to diffraction imaging problems where a model for the spatial coherence can be assumed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

WE-G-18A-08: Axial Cone Beam DBPF Reconstruction with Three-Dimensional Weighting and Butterfly Filtering

Purpose: With the major benefit in dealing with data truncation for ROI reconstruction, the algorithm of differentiated backprojection followed by Hilbert filtering (DBPF) is originally derived for image reconstruction from parallel- or fan-beam data. To extend its application for axial CB scan, we proposed the integration of the DBPF algorithm with 3-D weighting. In this work, we further propose the incorporation of Butterfly filtering into the 3-D weighted axial CB-DBPF algorithm and conduct an evaluation to verify its performance. Methods: Given an axial scan, tomographic images are reconstructed by the DBPF algorithm with 3-D weighting, in which streak artifacts exist along the direction of Hilbert filtering. Recognizing this orientation-specific behavior, a pair of orthogonal Butterfly filtering is applied on the reconstructed images with the horizontal and vertical Hilbert filtering correspondingly. In addition, the Butterfly filtering can also be utilized for streak artifact suppression in the scenarios wherein only partial scan data with an angular range as small as 270° are available. Results: Preliminary data show that, with the correspondingly applied Butterfly filtering, the streak artifacts existing in the images reconstructed by the 3-D weighted DBPF algorithm can be suppressed to an unnoticeable level. Moreover, the Butterfly filtering also works at the scenarios of partial scan, though the 3-D weighting scheme may have to be dropped because of no sufficient projection data are available. Conclusion: As an algorithmic step, the incorporation of Butterfly filtering enables the DBPF algorithm for CB image reconstruction from data acquired along either a full or partial axial scan.

60 APPLIED LIFE SCIENCES↗

A dictionary learning algorithm for compression and reconstruction of streaming data in preset order

There has been an emerging interest in developing and applying dictionary learning (DL) to process massive datasets in the last decade. Many of these efforts, however, focus on employing DL to compress and extract a set of important features from data, while considering restoring the original data from this set a secondary goal. On the other hand, although several methods are able to process streaming data by updating the dictionary incrementally as new snapshots pass by, most of those algorithms are designed for the setting where the snapshots are randomly drawn from a probability distribution. In this paper, we present a new DL approach to compress and denoise massive dataset in real time, in which the data are streamed through in a preset order (instances are videos and temporal experimental data), so at any time, we can only observe a biased sample set of the whole data. Here, our approach incrementally builds up the dictionary in a relatively simple manner: if the new snapshot is adequately explained by the current dictionary, we perform a sparse coding to find its sparse representation; otherwise, we add the new snapshot to the dictionary, with a Gram-Schmidt process to maintain the orthogonality. To compress and denoise noisy datasets, we apply the denoising to the snapshot directly before sparse coding, which deviates from traditional dictionary learning approach that achieves denoising via sparse coding. Compared to full-batch matrix decomposition methods, where the whole data is kept in memory, and other mini-batch approaches, where unbiased sampling is often assumed, our approach has minimal requirement in data sampling and storage: i) each snapshot is only seen once then discarded, and ii) the snapshots are drawn in a preset order, so can be highly biased. Through experiments on climate simulations and scanning transmission electron microscopy (STEM) data, we demonstrate that the proposed approach performs competitively to those methods in data reconstruction and denoising.

97 MATHEMATICS AND COMPUTING↗

Phase retrieval and reconstruction of coherent synthesis by genetic algorithm

Abstract In the context of diffractive optics, phase retrieval is a heavily investigated process of recreating an entire complex electric field from partial amplitude-only information through iterative algorithms. However, existing methods can fall into local minima during reconstructions or struggle to recover unusual and novel electric field distributions. We present a numerical method based on a global-optimization genetic algorithm that reconstructs non-trivial electric field distributions from single diffracted intensity distributions. Diffraction and propagation of the optical fields over arbitrary distances is modeled through implementation of the angular spectrum technique. Additionally, a coherently-locked laser array system is used as an experimental case-study demonstrating 0.09 π phase reconstruction accuracy of initial laser parameters from single intensity images.

59 BASIC BIOLOGICAL SCIENCES↗

Model-Based Iterative Reconstruction for One-Sided Ultrasonic Nondestructive Evaluation

One-sided ultrasonic nondestructive evaluation (UNDE) is extensively used to characterize structures that need to be inspected and maintained from defects and flaws that could affect the performance of power plants, such as nuclear power plants. Most UNDE systems send acoustic pulses into the structure of interest, measure the received waveform, and use an algorithm to reconstruct the quantity of interest. The most widely used algorithm in UNDE systems is the synthetic aperture focusing technique (SAFT) because it produces acceptable results in real time. Thus, a few regularized inversion techniques with linear models have been proposed which can improve on SAFT, but they tend to make simplifying assumptions that do not address how to obtain reconstructions from large real datasets. In this paper, we propose a model-based iterative reconstruction (MBIR) algorithm designed for scanning UNDE systems. To further reduce some of the artifacts in the results, we enhance the forward model to account for the transmitted beam profile, the occurrence of direct arrival signals, and the correlation between scans from adjacent regions. Next, we combine the forward model with a spatially variant prior model to account for the attenuation of deeper regions. Moreover, we also present an algorithm to jointly reconstruct measurements from large datasets. Finally, using simulated and extensive experimental data, we show MBIR results and demonstrate how we can improve over SAFT as well as existing regularized inversion techniques.

47 OTHER INSTRUMENTATION↗

WE-DE-BRA-09: Fast Megavoltage CT Imaging with Rapid Scan Time and Low Imaging Dose in Helical Tomotherapy

Purpose: Megavoltage computed tomography (MVCT) imaging has been widely used for daily patient setup with helical tomotherapy (HT). One drawback of MVCT is its very long imaging time, owing to slow couch speed. The purpose of this study was to develop an MVCT imaging method allowing faster couch speeds, and to assess its accuracy for image guidance for HT. Methods: Three cadavers (mimicking closest physiological and physical system of patients) were scanned four times with couch speeds of 1, 2, 3, and 4 mm/s. The resulting MVCT images were reconstructed using an iterative reconstruction (IR) algorithm. The MVCT images were registered with kilovoltage CT images, and the registration errors were compared with the errors with conventional filtered back projection (FBP) algorithm. Moreover, the fast MVCT imaging was tested in three cases of total marrow irradiation as a clinical trial. Results: Three-dimensional registration errors of the MVCT images reconstructed with the IR algorithm were significantly smaller (p < 0.05) than the errors of images reconstructed with the FBP algorithm at fast couch speeds (3, 4 mm/s). The scan time and imaging dose at a speed of 4 mm/s were reduced to 30% of those from a conventional coarse mode scan. For the patient imaging, a limited number of conventional MVCT (1.2 mm/s) and fast MVCT (3 mm/s) reveals acceptable reduced imaging time and dose able to use for anatomical registration. Conclusion: Fast MVCT with IR algorithm maybe clinically feasible alternative for rapid 3D patient localization. This technique may also be useful for calculating daily dose distributions or organ motion analyses in HT treatment over a wide area.

60 APPLIED LIFE SCIENCES↗