Search NASA⌕ Search

SEARCH · Search NASA

Results for “Repeatability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Southeast Regional Carbon Sequestration Partnership (SECARB) Collect Repeat 3-D Survey

The baseline 3-D survey of Cranfield was collected by Denbury Onshore LLC. in 2007 and data provided to the SECARB Early team at the BEG as a major cost share contribution for Phase II. The baseline 3-D survey covered the entire Cranfield Field as well into the surrounding brine-saturated water leg. This data remains extremely valuable in characterization for Phase III, and has been analyzed extensively. Bureau researchers Hongliu Zeng and Tip Meckel have analyzed the baseline 3-D to develop reservoir models. For example, Zeng enhanced seismic data to extract textures suggestive of high sinuosity aggradational point bar from the lower Tuscaloosa interval. Meckel assessed the logs and seismically imaged structure to better define the oil-water contact to assure that the DAS experiment was set in the water leg, and mapped the graben-edge fault that separates the Phase II and the Phase III areas. Additional characterization work continues by a number of students under funding from SECARB (Kordi dissertation) as well as additional efforts under BES funding though the CFSES project.

01 COAL, LIGNITE, AND PEAT↗

IER 557: Godiva Pulse Repeatability and Characterization (CED-3A Report)

Godiva IV is a fast burst critical assembly constructed of approximately 65 kg of highly enriched uranium (HEU) fuel alloyed with 1.5% molybdenum for strength. Godiva IV is proposed as the radiation source for IER 498: Design a Shielding Benchmark with a Metal Critical Source. IER 498 proposes a two-burst method to determine the performance of shielding samples, comparing the transmission of the source radiation to detectors with and without a shielding sample present. This eliminates the need for an absolute calibration and allows many uncertainties to cancel. However, the source term variability must be low compared to other sources of experimental uncertainty to ensure the overall uncertainty meets acceptable levels to provide useful measurements. The primary goal of this experiment is to quantify the source term variability, or reproducibility, of Godiva bursts, focusing on the 70 °C bursts planned for IER 498 measurements. Discussions during IER 498 noted that a number of bursts (on the order of six to ten) as identical as possible would be performed and that a 5-7% standard deviation in source intensity would be acceptable.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗