Search NASA⌕ Search

SEARCH · Search NASA

Results for “SAFETY DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Advances in actinide thin films: synthesis, properties, and future directions

Actinide-based compounds exhibit unique physics due to the presence of 5f electrons, and serve in many cases as important technological materials. Targeted thin film synthesis of actinide materials has been successful in generating high-purity specimens in which to study individual physical phenomena. These films have enabled the study of the unique electron configuration, strong mass renormalization, and nuclear decay in actinide metals and compounds. The growth of these films, as well as their thermophysical, magnetic, and topological properties, have been studied in a range of chemistries, albeit far fewer than most classes of thin film systems. This relative scarcity is the result of limited source material availability and safety constraints associated with the handling of radioactive materials. Here, we review recent work on the synthesis and characterization of actinide-based thin films in detail, describing both synthesis methods and modeling techniques for these materials. Further, we review reports on pyrometallurgical, solution-based, and vapor deposition methods. We highlight the current state-of-the-art in order to construct a path forward to higher quality actinide thin films and heterostructure devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improved Stability and Cyclability of Ceramic Solid Electrolyte by Coating Polymer

Rechargeable all-solid-state lithium (Li) metal batteries show better safety and energy density compared to commercial Li-ion batteries using liquid electrolyte. As the key component of Li metal batteries, ceramic solid-state electrolyte has attracted great interest because of its high ion conductivity and great potential in interfacing with Li metal. Ceramic electrolyte has a more stable interface with Li metal than liquid electrolyte, but chemical reaction and Li dendrite growth at the electrolyte/Li interface are still significant, which causes device degradation and failure by cycling of Li plating and stripping. Unlike ceramic electrolyte, polymer electrolyte has a relatively stable interface with Li metal and better mechanical flexibility. Therefore, we introduced a polymer electrolyte coating to protect the ceramic electrolyte from direct contact with Li metal. The galvanotactic cycling Li plating/striping data on the devices with (without) the coating illustrates increased (decreased) overall conductivity and cyclability of the test cell by the cycling. Nanometer-scale ionic-transport imaging, based on atomic force microscopy, shows that cycling degrades the ceramic-only electrolyte by partially blocking ionic transport in areas; in contrast, cycling on the polymer-coated electrolyte improves ionic conductivity. Compared with the ceramic-only electrolyte, this novel polymer electrolyte coating on ceramic electrolyte shows less degradation when in contact with Li metal.

25 ENERGY STORAGE↗

Pressure safety approach for PIP-II cryogenic distribution system and cryomodules

The Proton Improvement Plan-II (PIP-II) is a superconducting linear accelerator being built at Fermilab that will provide 800 MeV proton beam for neutrino production. The linac consists of a total of twenty-three (23) cryomodules of five (5) different types. Cooling is required at 2K, 5K and 40K. The Cryogenic Distribution System (CDS) consists of a Distribution Valve Box, ~285 m of cryogenic transfer line, modular Bayonet Cans to interface with cryomodules, and a Turnaround Can. The cryogenic system must provide protection from over-pressure by sizing pressure relief devices for all volumes and process line circuits. The cryomodule cavity circuits have dual pressure ratings, 4.1 bara when cold and 2.05 bara when warm (T>80K). Worst case relieving cases will be identified. The methods for determining heat flux will be presented. For the relieving occurring in the linac tunnel, flow must vent to outside to avoid an oxygen deficiency hazard. Also, we will present vacuum vesse l relief sizing to protect the cryogenic distribution system vacuum shells from over pressure during an internal line rupture. The project is funded by US DOE Offices of Science, High Energy Physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pressure safety approach for PIP-II cryogenic distribution system and cryomodules

The Proton Improvement Plan-II (PIP-II) is a superconducting linear accelerator being built at Fermilab that will provide 800 MeV proton beam for neutrino production. The linac consists of a total of twenty-three (23) cryomodules of five (5) different types. Cooling is required at 2K, 5K and 40K. The Cryogenic Distribution System (CDS) consists of a Distribution Valve Box, ~285 m of cryogenic transfer line, modular Bayonet Cans to interface with cryomodules, and a Turnaround Can. The cryogenic system must provide protection from over-pressure by sizing pressure relief devices for all volumes and process line circuits. The cryomodule cavity circuits have dual pressure ratings, 4.1 bara when cold and 2.05 bara when warm (T>80K). Worst case relieving cases will be identified. The methods for determining heat flux will be presented. For the relieving occurring in the linac tunnel, flow must vent to outside to avoid an oxygen deficiency hazard. Also, we will present vacuum vessel relief sizing to protect the cryogenic distribution system vacuum shells from over pressure during an internal line rupture. The project is funded by US DOE Offices of Science, High Energy Physics.

43 PARTICLE ACCELERATORS↗

Heat Transfer Salts for Nuclear Reactor Systems - Chemistry Control, Corrosion Mitigation, and Modeling

The concept of a molten salt reactor has existed for nearly sixty years. Previously all work was done during a large collaborative effort at Oak Ridge National Laboratory, culminating in a research reactor which operated for 15,000 hours without major error. This technical success has garnished interest in modern, high temperature, reactor schemes. Research using molten fluoride salts for nuclear applications requires a steady supply of high grade molten salts. There is no bulk supplier of research grade fluoride salts in the world, so a facility which could provide all the salt needed for testing at the University of Wisconsin had to be produced. Two salt purification devices were made for this purpose, a large scale purifier, and a small scale purifier, each designed to clean the salts from impurities and reduce their corrosion potential. As of now, the small scale has performed with flibe salt, hydrogen, and hydrogen fluoride, yielding clean salt. This salt is currently being used in corrosion testing facilities at the Massachusetts Institute of Technology and the University of Wisconsin. Working with the beryllium based salts requires extensive safety measures and health monitoring to prevent the development of acute or chronic beryllium disease, two pulmonary diseases created by an allergic reaction to beryllium in the lungs. Extensive health monitoring, engineering controls, and environment monitoring had to be set up with the University of Wisconsin department of Environment, Health and Safety. The hydrogen fluoride required for purification was also an extreme health hazard requiring thoughtful planning and execution. These dangers have made research a slow and tedious process. Simple processes, such as chemical handling and clean-up, can take large amounts of ingenuity and time. Other work has complemented the experimental research at Wisconsin to advance high temperature reactor goals. Modeling work has been performed in house to re-evaluate thermophysical properties of flibe and flinak. Pacific Northwest National Laboratories has focused on evaluating the fluorinating gas nitrogen trifluoride as a potential salt purification agent. Work there was performed on removing hydroxides and oxides from flinak salt under controlled conditions. Lastly, the University of California Berkeley has spent considerable time designing and simulating reactor components with fluoride salts at high temperatures. Despite the hurdles presented by the innate chemical hazards, considerable progress has been made. The stage has been set to perform new research on salt chemical control which could advance the fluoride salt cooled reactor concept towards commercialization. What were previously thought of as chemical undesirable, but nuclear certified, alloys have been shown to be theoretically compatible with fluoride salts at high temperatures. This preliminary report has been prepared to communicate the construction of the basic infrastructure required for flibe, as well as suggest original research to performed at the University of Wisconsin. Simultaneously, the contents of this report can serve as a detailed, but introductory guide to allow anyone to learn the fundamentals of chemistry, engineering, and safety required to work with flibe salt.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Nuclear Power Plant Component Flooding Fragility Research

This report describes progress on Nuclear Power Plant component flooding fragility research conducted at the Component Flooding Evaluation Laboratory (CFEL). The progress includes additional steering committee membership and invitations, performance improvements to the Portal Evaluation Tank (PET), PET based experiments using industrial steel doors, pipe rupture spray pattern characterization, coupling the smoothed particle hydrodynamics (SPH) code Neutrino and the Idaho National Laboratory (INL) developed Risk Analysis Virtual Environment (RAVEN), continued development of component fragility mathematical models, and wave impact simulation device development, testing, and analysis.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design of a telemetry system based on wireless power transmission for physiological parameter monitoring

An implanted telemetry system for experimental animals with or without anaesthesia can be used to continuously monitor physiological parameters. This system is significant not only in the study of organisms but also in the evaluation of drug efficacy, artificial organs, and auxiliary devices. The system is composed of a miniature electronic capsule, a wireless power transmission module, a data-recording device, and a processing module. An electrocardiograph, a temperature sensor, and a pressure sensor are integrated in the miniature electronic capsule, in which the signals are transmitted in vitro by wireless communication after filtering, amplification, and A/D sampling. To overcome the power shortage of batteries, a wireless power transmission module based on electromagnetic induction was designed. The transmitting coil of a rectangular-section solenoid and a 3D receiving coil are proposed according to stability and safety constraints. Experiments show that at least 150 mW of power could pick up on the load in a volume of Φ10.5 mm × 11 mm, with a transmission efficiency of 2.56%. Vivisection experiments verified the feasibility of the integrated radio-telemetry system.

36 MATERIALS SCIENCE↗

Structure evolution and thermal stability of high-energy density Li-ion battery cathode Li 2 VO 2 F

Lithium-ion batteries (LIBs) provide high-energy-density electrochemical energy storage, which plays a central role in advancing technologies ranging from portable electronics to electric vehicles (EVs). However, a demand for lighter, more compact devices and for extended range EVs continues to fuel the need for higher energy density storage systems. Li 2 VO 2 F, which is synthesized in its lithiated state, allows two-electron transfer per formula during the electrochemical reaction providing a high theoretical capacity of 462 mAh/g. Herein, the synthesis and electrochemical performance of Li 2 VO 2 F are optimized. The thermal stability of Li 2 VO 2 F, which is related to the safety of a battery is studied by thermal gravimetric analysis. The structure and vanadium oxidation state evolution along Li cycling are studied by ex-situ X-ray diffraction and absorption techniques. It is shown that the rock-salt structure of pristine Li 2 VO 2 F is stable up to at least 250°C, and is preserved upon Li cycling, which proceeds by the solid-solution mechanism. However, not all Li can be removed from the structure upon charge to 4.5 V, limiting the experimentally obtained capacity.

25 ENERGY STORAGE↗

KM-IT Mobile Platform for D and D - 18300

Knowledge management (KM) is the practice or process responsible for gathering, analyzing, storing and sharing insights, experiences, knowledge, and information within an organization or community. The main focus of the Knowledge Management Information Tool (KM-IT) for the deactivation and decommissioning (D and D) community is to enhance safety through improved efficiencies (e.g., by reducing the need to rediscover the knowledge and experience gained over time and to promote the reuse of the existing knowledge). KM-IT serves as a centralized information repository and a common interface for D and D related activities. It facilitates the gathering, analysis, storage and sharing of knowledge and information within the D and D community. FIU has developed eight active modules as part of the web-based mobile application for the KM-IT, which can be accessed from m.dndkm.org: Vendor, Specialist Directory, Technology, Picture Library, Hotline, Lessons Learned, Best Practices and Fixatives. All of the mobile modules are scaled-down versions of the desktop module available at www.dndkm.org and publish data from the KM-IT database to the D and D community. FIU has recently developed a native mobile application for Android mobile devices for selecting D and D fixatives. This application runs natively on mobile devices and displays data through the fixative services which uses REST-based API for communication across mobile platforms. Xamarin Forms are used to develop the front-end application for the Android operating system (OS) and will be used for future platforms (iOS and Windows) as well. The native fixative application can be installed on mobile devices to search information related to fixatives, decontamination gels and strippable coatings applicable to D and D. The KM-IT platform includes a comprehensive database of commercially available fixatives and other contamination control products. Search functionality allows the user to filter and sort these products according to the search criteria or keyword. Three levels of refinement are available via a drill down menu for the criteria. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Automotive Li-Ion Batteries: Current Status and Future Perspectives

Lithium-ion batteries (LIBs) are currently the most suitable energy storage device for powering electric vehicles (EVs) owing to their attractive properties including high energy efficiency, lack of memory effect, long cycle life, high energy density and high power density. These advantages allow them to be smaller and lighter than other conventional rechargeable batteries such as lead–acid batteries, nickel–cadmium batteries (Ni–Cd) and nickel–metal hydride batteries (Ni–MH). Modern EVs, however, still suffer from performance barriers (range, charging rate, lifetime, etc.) and technological barriers (high cost, safety, reliability, etc.), limiting their widespread adoption. Given these facts, this review sets the extensive market penetration of LIB-powered EVs as an ultimate objective and then discusses recent advances and challenges of electric automobiles, mainly focusing on critical element resources, present and future EV markets, and the cost and performance of LIBs. Finally, novel battery chemistries and technologies including high-energy electrode materials and all-solid-state batteries are also evaluated for their potential capabilities in next-generation long-range EVs.

25 ENERGY STORAGE↗

Micro-inverter solar panel mounting

Processes, systems, devices, and articles of manufacture are provided. Each may include adapting micro-inverters initially configured for frame-mounting to mounting on a frameless solar panel. This securement may include using an adaptive clamp or several adaptive clamps secured to a micro-inverter or its components, and using compressive forces applied directly to the solar panel to secure the adaptive clamp and the components to the solar panel. The clamps can also include compressive spacers and safeties for managing the compressive forces exerted on the solar panels. Friction zones may also be used for managing slipping between the clamp and the solar panel during or after installation. Adjustments to the clamps may be carried out through various means and by changing the physical size of the clamps themselves.

14 SOLAR ENERGY↗

Patient Positioning Based on a Radioactive Tracer Implanted in Patients With Localized Prostate Cancer: A Performance and Safety Evaluation

Purpose: To evaluate the performance and safety of a radiation therapy positioning system (RealEye) based on tracking a radioactive marker (Tracer) implanted in patients with localized prostate cancer. Methods and Materials: We performed a single-arm multi-institutional trial in 20 patients. The iridium-192 ({sup 192}Ir)-containing Tracer was implanted in the patient together with 4 standard gold seed fiducials. Patient prostate-related symptoms were evaluated with the International Prostate Symptom Score (IPSS) questionnaire. Computed tomography (CT) was performed for treatment planning, during treatment, and after treatment to evaluate the migration stability of the Tracer. At 5 treatment sessions, cone beam CT was performed to test the positioning accuracy of the RealEye. Results: The Tracer was successfully implanted in all patients. No device or procedure-related adverse events occurred. Changes in IPSS scores were limited. The difference between the mean change in Tracer-fiducial distance and the mean change in fiducial-fiducial distance was -0.39 mm (95% confidence interval [CI] upper boundary, -0.22 mm). The adjusted mean difference between Tracer position according to RealEye and the Tracer position on the CBCT for all patients was 1.34 mm (95% CI upper boundary, 1.41 mm). Conclusions: Implantation of the Tracer is feasible and safe. Migration stability of the Tracer is good. Prostate patients can be positioned and monitored accurately by using RealEye.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

RIA Testing in TREAT

The Transient Reactor Test facility (TREAT) was constructed in the late 1950’s. The reactors flexible design and multi-mission nature provided thousands of transient irradiations for numerous reactor fuels and transient types before being placed in standby in 1994. The reactor resumed operations in 2017 to reclaim its crucial role in nuclear-heated safety research. A principal goal of restarting the reactor was to perform transient testing of Accident Tolerant Fuels (ATF), supporting their safe adoption by the commercial Light Water Reactor (LWR) fleet. In support of the Accident Tolerant Fuels mission, multiple capsules have been designed and are currently being designed to test fuel specimens under varying conditions. The Minimal Activation Retrievable Capsule Holder (MARCH) system was designed to support high throughput testing by using a modular approach where an outer containment structure will act as the primary safety containment. The MARCH system is designed to house various modules for testing different fuel systems in different environments. The near-term tests for the ATF concepts will use the Static Environment Rodlet Transient Test Apparatus (SERTTA), aka MARCH-SERTTA. MARCH-SERTTA is capable of testing a single ATF rodlet 10 cm in length in a static pool of water with initial conditions up to 200°C and 500 psi. The purpose of the MARCH-SERTTA device is to perform integral tests evaluating the Pellet Clad Mechanical Interaction (PCMI) performance of LWR fuel concepts in design basis Reactivity Initiated Accidents (RIA). This will be accomplished by testing a variety of ATF fuel concepts under varying initial thermal-hydraulic conditions and varying prompt energy pulses. The flexibility of TREAT and the MARCH-SERTTA capsule enables testing of a unique, non-fueled, rod specimen under similar conditions as the fueled specimens to perform separate-effect tests. This non-fueled rod will be used to study the thermal-hydraulic behavior (specifically determine the critical heat flux) during these fast prompt transients.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Mechanical Thrombectomy of Iliac Vein Thrombosis in a Pig Model Using the Rotarex and Aspirex Catheters

Purpose: To investigate the efficacy and safety of mechanical thrombectomy for iliac vein thrombosis using Rotarex and Aspirex catheters in a pig model. Materials and Methods: Iliac vein thrombosis was induced in six pigs by means of an occlusion-balloon catheter and thrombin injection. The presence of thrombi was verified by digital subtraction angiography (DSA) and computed tomography (CT). Thrombectomy was performed using 6F and 8F Rotarex and 6F, 8F, and 10F Aspirex catheters (Straub Medical AG, Wangs, Switzerland). After intervention, DSA and CT were repeated to evaluate the efficacy of mechanical thrombectomy and to exclude local complications. In addition, pulmonary CT was performed to rule out pulmonary embolism. Finally, all pigs were killed, and iliac veins were dissected to perform macroscopic and histological examination. Results: Thrombus induction was successfully achieved in all animals as verified by DSA and CT. Subsequent thrombectomy lead to incomplete recanalization of the iliac veins with residual thrombi in all cases. However, the use of the 6F and 8F Rotarex catheters caused vessel perforation and retroperitoneal hemorrhage in all cases. Application of the Aspirex device caused one small transmural perforation in a vessel treated with a 10F Aspirex catheter, and this was only seen microscopically. Pulmonary embolism was detected in one animal treated with the Rotarex catheters, whereas no pulmonary emboli were seen in animals treated with the Aspirex catheters. Conclusion: The Aspirex catheter allowed subtotal and safe recanalization of iliac vein thrombosis. In contrast, the use of the Rotarex catheter caused macroscopically obvious vessel perforations in all cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Frequencies of the geodesic acoustic mode and Alfvén gap modes in high-q{sup 2}β plasmas with non-circular cross section

This work generalizes recent results [O. P. Fesenyuk et al., Plasma Phys. Controlled Fusion 54, 085014 (2012)] to plasmas with elongated cross section. It suggests new expressions for the frequencies of the geodesic acoustic mode and Alfvén gap modes in tokamaks, with a large ratio of the plasma pressure to the magnetic field pressure and a large safety factor (q≫1, which takes place in discharges with reversed-shear configuration and, especially, in hollow-current discharges)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Single Stage Light Gas Gun Control System

The intermediate light gas gun at the STAR facility is used for shock wave physics testing with projectile speeds between 25 m/s and 1000 m/s. In order to operate the gun, there are several remote valves, pumps, and sensors that must be operated from the control room. In an effort to improve the engineered safety and efficiency of the gun's operation, a new gas plumbing and controls system must be implemented to simplify operator interaction with high pressure and lower the chance of human error. A new plumbing system has been designed which will allow the bottle farm system, where high pressure gas is stored, to be remotely operated during gun pressurization in addition to a new control system. This new system utilizes LabVIEW, which will communicate directly with a data acquisition and control device located in the gun bay to easily operate the gun pressurization and firing.

42 ENGINEERING↗

Estimating traffic volumes for signalized intersections using connected vehicle data

Recently connected vehicle (CV) technology has received significant attention thanks to active pilot deployments supported by the US Department of Transportation (USDOT). At signalized intersections, CVs may serve as mobile sensors, providing opportunities of reducing dependencies on conventional vehicle detectors for signal operation. However, most of the existing studies mainly focus on scenarios that penetration rates of CVs reach certain level, e.g., 25%, which may not be feasible in the near future. How to utilize data from a small number of CVs to improve traffic signal operation remains an open question. In this work, we develop an approach to estimate traffic volume, a key input to many signal optimization algorithms, using GPS trajectory data from CV or navigation devices under low market penetration rates. To estimate traffic volumes, we model in this paper vehicle arrivals at signalized intersections as a time-dependent Poisson process, which can account for signal coordination. The estimation problem is formulated as a maximum likelihood problem given multiple observed trajectories from CVs approaching to the intersection. An expectation maximization (EM) procedure is derived to solve the estimation problem. Two case studies were conducted to validate our estimation algorithm. One uses the CV data from the Safety Pilot Model Deployment (SPMD) project, in which around 2800 CVs were deployed in the City of Ann Arbor, MI. The other uses vehicle trajectory data from users of a commercial navigation service in China. Mean absolute percentage error (MAPE) of the estimation is found to be 9–12%, based on benchmark data manually collected and data from loop detectors. Finally, considering the existing scale of CV deployments, the proposed approach could be of significant help to traffic management agencies for evaluating and operating traffic signals, paving the way of using CVs for detector-free signal operation in the future.

97 MATHEMATICS AND COMPUTING↗