Search NASA⌕ Search

SEARCH · Search NASA

Results for “SIMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Degradation of Victoria Crater, Mars

The $\sim$750 m diameter and $\sim$75 m deep Victoria crater in Meridiani Planum, Mars, presents evidence for significant degradation including a low, serrated, raised rim characterized by alternating alcoves and promontories, a surrounding low relief annulus, and a floor partially covered by dunes. The amount and processes of degradation responsible for the modified appearance of Victoria crater were evaluated using images obtained in situ by the Mars Exploration Rover Opportunity in concert with a digital elevation model created using orbital HiRISE images. Opportunity traversed along the north and northwest rim and annulus, but sufficiently characterized features visible in the DEM to enable detailed measurements of rim relief, ejecta thickness, and wall slopes around the entire degraded, primary impact structure. Victoria retains a 5 m raised rim consisting of 1-2 m of uplifted rocks overlain by 3 m of ejecta at the rim crest. The rim is $\sim$120 to 220 m wide and is surrounded by a dark annulus reaching an average of 590 m beyond the raised rim. Comparison between observed morphology and that expected for pristine craters 500 to 750 m across indicate the original, pristine crater was close to 600 m in diameter. Hence, the crater has been erosionally widened by approximately 150 m and infilled by about 50 m of sediments. Eolian processes are responsible for modification at Victoria, but lesser contributions from mass wasting or other processes cannot be ruled out. Erosion by prevailing winds is most significant along the exposed rim and upper walls and accounts for $\sim$50 m widening across a WNW-ESE diameter. The volume of material eroded from the crater walls and rim is $\sim$20% less than the volume of sediments partially filling the crater, indicating eolian infilling from sources outside the crater over time. The annulus formed when $\sim$1 m deflation of the ejecta created a lag of more resistant hematite spherules that trapped darker, regional basaltic sands.

Wilson, Sharon A.↗

Stroboscopic Image Modulation to Reduce the Visual Blur of an Object Being Viewed by an Observer Experiencing Vibration

A method and apparatus for reducing the visual blur of an object being viewed by an observer experiencing vibration. In various embodiments of the present invention, the visual blur is reduced through stroboscopic image modulation (SIM). A SIM device is operated in an alternating "on/off" temporal pattern according to a SIM drive signal (SDS) derived from the vibration being experienced by the observer. A SIM device (controlled by a SIM control system) operates according to the SDS serves to reduce visual blur by "freezing" (or reducing an image's motion to a slow drift) the visual image of the viewed object. In various embodiments, the SIM device is selected from the group consisting of illuminator(s), shutter(s), display control system(s), and combinations of the foregoing (including the use of multiple illuminators, shutters, and display control systems).

Kaiser, Mary K.↗

Developing a soil inversion model framework for regional permafrost monitoring

Currently, the community lacks capabilities to assess and monitor landscape scale permafrost active layer dynamics over large extents. To address this need, we developed a concept of a remote sensing based Soil Inversion Model for regional Permafrost (SIM-P) monitoring. The current SIM-P framework includes a satellite-based soil process model and a soil dielectric model. We are also working on incorporating a radar scattering model for Arctic tundra into the SIM-P framework. A unified soil parameterization scheme was developed to harmonize key soil thermal, hydraulic and dielectric parameters in the soil process and radar models that can be used in the joint soil-radar inversion framework. The soil parameter retrievals of the SIM-P framework include soil organic content (SOC) and active layer thickness (ALT). Initial tests of SIM-P using in-situ soil permittivity observations showed reasonable accuracy in predicting site-level SOC and soil temperature profiles at an Alaska tundra site and ALT in Arctic Alaska. SIM-P will be further tested using airborne P- and L-band radar data collected during NASA’s Arctic Boreal Vulnerability Experiment (ABoVE) to evaluate the sensitivity of longwave radar to active layer properties.

Miller, Charles E.↗

Charge Retention by Organometallic Dications on Self-Assembled Monolayer Surfaces

Charge retention by mass-selected ruthenium trisbipyridine dications, or Ru(bpy)32+, soft-landed onto self-assembled monolayer (SAM) surfaces of 1H, 1H, 2H, 2H-perfluorodecane-1-thiol (FSAM), 11-mercaptoundecanoic acid (COOH-SAM), and 11-amino-1-undecanethiol (HSAM) on gold was examined using in situ time-resolved secondary ion mass spectrometry in a Fourier transform ion cyclotron resonance apparatus (FT-ICR SIMS). FT-ICR SIMS analysis was performed during ion soft-landing and for 8–15 hours after the ion beam was switched off. Our results demonstrate efficient retention of the doubly charged precursor ion on the FSAM and COOH-SAM surfaces manifested by the abundant Ru(bpy)32+ ions in the SIMS spectra. In contrast, only the singly charged Ru(bpy)3+ and Ru(bpy)2+ ions were observed on HSAM, indicating rapid loss of at least one charge by the deposited dications. The signal of Ru(bpy)32+ on COOH-SAM remained almost constant for more than 8 hours after the end of ion soft-landing, while a relatively fast decay followed by a plateau region was observed on the FSAM surface. However, we found that SIMS analysis of Ru(bpy)32+ ions soft-landed onto FSAM is complicated by facile ion-molecule reactivity occurring either on the surface or in the SIMS plume, making it difficult to accurately measure the charge reduction kinetics. Efficient retention of the doubly charged Ru(bpy)32+ ions on COOH-SAM is remarkably different from facile neutralization of protonated peptides deposited onto this surface reported in previous studies. Our results indicate different mechanisms of charge reduction of protonated molecules and permanent ions, such as Ru(bpy)32+, on SAM surfaces. Thus, we propose that proton loss is the major charge reduction channel for the protonated species, while electron transfer through the insulating SAM is responsible for the charge loss by permanent ions. Fundamental understanding of charge reduction phenomena is essential for controlled preparation of catalytically active substrates using ion soft-landing.

charge reduction↗

Testing and Expertise for Marine Energy (TEAMER) Program Support - Numerical Modeling Assistance for iProTech's "PIP" WEC Device: Cooperative Research and Development Final Report, CRADA Number CRD-20-17303

Develop a time-domain, 3 degree of freedom numerical model of IProTech's PIP device, including power take-off (PTO), that can be used to develop control algorithms and establish a baseline technology performance level (TPL). This is important to IProTech because having a good numerical model allows IProTech to optimize design and control algorithms on an ongoing basis. A baseline TPL enables the PIP technology to be benchmarked against other wave energy converter (WEC) concepts, providing (i) justification (or not) for investment in wave tank model testing, (ii) identifying optimum design parameters and control algorithms for the test model, (iii) specifying test conditions and (iv) interpreting wave tank test results. An accredited WEC-Sim model of the PIP device is an essential tool for further development of the technology. 1) The development of numerical models of the PIP concept will enable iProTech to evaluate the potential performance of this concept, and to investigate how sensitive the device is to different variables within the system (e.g. hydraulic components, geometry dimensions, etc.) 2) The numerical models were developed with WEC-Sim and PTO-Sim -- the de-facto industry standard WEC numerical modeling tools. A detailed model of the system's hydraulic circuit was developed with PTO-Sim. However, WEC-Sim is based on linear hydrodynamics and has several limitations; validation against high fidelity models/physical scale models would help to build confidence in the results.

16 TIDAL AND WAVE POWER↗

Reducing the matrix effect in mass spectral imaging of biofilms using flow-cell culture

The interactions between soil microorganisms and soil minerals play a crucial role in the formation and evolution of minerals and the stability of soil aggregates. Due to the heterogeneity and diversity of the soil environment, the under-standing of the functions of bacterial biofilms in soil minerals at the microscale is limited. A soil mineral-bacterial biofilm system was used as a model in this study, and it was analyzed by time-of-flight secondary ion mass spectrometry (ToF-SIMS) to acquire molecular level information. Static culture in multi-wells and dynamic flow-cell culture in microfluidics of biofilms were investigated. Our results show that more characteristic molecules of biofilms can be observed in SIMS spectra of the flow-cell culture. In contrast, biofilm signature peaks are buried under the mineral components in SIMS spectra in the static culture case. Spectral overlay was used in peak selection prior to performing Principal component analysis (PCA). Comparisons of the PCA results between the static and flow-cell culture show more pronounced molecular features and higher loadings of organic peaks of the dynamic cultured specimens. For example, fatty acids secreted from bacterial biofilm extracellular polymeric substance are likely to be responsible for biofilm dispersal due to mineral treatment up to 48 h. Such findings suggest that the use of microfluidic cells to dynamically culture biofilms be a more suitable method for reducing the matrix effect arisen from the growth medium and minerals as a perturbation fac-tor for improved spectral and multivariate analysis of complex mass spectral data in ToF-SIMS. These results show that the interaction mechanism between biofilms and soil minerals at the molecular level can be better studied using the flow-cell culture and advanced mass spectral imaging techniques like ToF-SIMS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Molecular detection of per- and polyfluoroalkyl substances in water using time-of-flight secondary ion mass spectrometry

Detection of per- and polyfluoroalkyl substances (PFASs) is crucial in environmental mitigation and remediation of these persistent pollutants. We demonstrate that time-of-flight secondary ion mass spectrometry (ToF-SIMS) is a viable technique to analyze and identify these substances at parts per trillion (ppt) level in real field samples without complicated sample preparation due to its superior surface sensitivity. Several representative PFAS compounds, such as perfluorooctanesulfonic acid (PFOS), perfluorobutanoic acid (PFBA), perfluoropentanoic acid (PFPeA), perfluoheptanoic acid (PFHpA), and perfluorononanoic acid (PFNA), and real-world groundwater samples collected from monitoring wells installed around at a municipal wastewater treatment plant located in Southern California were analyzed in this work. ToF-SIMS spectral comparison depicts sensitive identification of pseudo-molecular ions, characteristic of reference PFASs. Additionally, principal component analysis (PCA) shows clear discrimination among real samples and reference compounds. Our results show that characteristic molecular ion and fragments peaks can be used to identify PFASs. Furthermore, SIMS two-dimensional (2D) images directly exhibit the distribution of perfluorocarboxylic acid (PFCA) and PFOS in simulated mixtures and real wastewater samples. Such findings indicate that ToF-SIMS is useable to determine PFAS compounds in complex environmental water samples. In conclusion, ToF-SIMS provides simple sample preparation and high sensitivity in mass spectral imaging, offering an alternative solution for environmental forensic analysis of PFASs in wastewater in the future.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Selected Ion Monitoring for Orbitrap-Based Metabolomics

Orbitrap mass spectrometry in full scan mode enables the simultaneous detection of hundreds of metabolites and their isotope-labeled forms. Yet, sensitivity remains limiting for many metabolites, including low-concentration species, poor ionizers, and low-fractional-abundance isotope-labeled forms in isotope-tracing studies. Here, we explore selected ion monitoring (SIM) as a means of sensitivity enhancement. The analytes of interest are enriched in the orbitrap analyzer by using the quadrupole as a mass filter to select particular ions. In tissue extracts, SIM significantly enhances the detection of ions of low intensity, as indicated by improved signal-to-noise (S/N) ratios and measurement precision. In addition, SIM improves the accuracy of isotope-ratio measurements. SIM, however, must be deployed with care, as excessive accumulation in the orbitrap of similar m/z ions can lead, via space-charge effects, to decreased performance (signal loss, mass shift, and ion coalescence). Ion accumulation can be controlled by adjusting settings including injection time and target ion quantity. Overall, we suggest using a full scan to ensure broad metabolic coverage, in tandem with SIM, for the accurate quantitation of targeted low-intensity ions, and provide methods deploying this approach to enhance metabolome coverage.

59 BASIC BIOLOGICAL SCIENCES↗

Observational Model for Precision Astrometry with the Space Interferometry Mission

The Space Interferometry Mission (SIM) is a space-based 10-m baseline Michelson optical interferometer operating in the visible waveband that is designed to achieve astrometric accuracy in the single digits of the microarcsecond domain. Over a narrow field of view SIM is expected to achieve a mission accuracy of 1 microarcsecond. In this mode SIM will search for planetary companions to nearby stars by detecting the astrometric "wobble" relative to a nearby reference star. In its wide-angle mode, SIM will provide 4 microarcsecond precision absolute position measurements of stars, with parallaxes to comparable accuracy, at the end of its 5-year mission. The expected proper motion accuracy is around 3 microarcsecond/year, corresponding to a transverse velocity of 10 m/ s at a distance of 1 kpc. The basic astrometric observable of the SIM instrument is the pathlength delay. This measurement is made by a combination of internal metrology measurements that determine the distance the starlight travels through the two arms of the interferometer, and a measurement of the white light stellar fringe to find the point of equal pathlength. Because this operation requires a non-negligible integration time, the interferometer baseline vector is not stationary over this time period, as its absolute length and orientation are time varying. This paper addresses how the time varying baseline can be "regularized" so that it may act as a single baseline vector for multiple stars, as required for the solution of the astrometric equations.

TILE OBSERVATIONS↗

Measurement of the Non-common Vertex Error of a Double Corner Cube

The Space Interferometry Mission (SIM) requires the control of the optical path of each interferometer with picometer accuracy. Laser metrology gauges are used to measure the path lengths to the fiiducial corner cubes at the siderostats. Due to the geometry of SIM a single corner cube does not have sufficient acceptance angle to work with all the gauges. Therefore SIM employs a double corner cube. Current fabrication methods are in fact not capable of producing such a double corner cube with vertices having sufficient commonality. The plan for SIM is to measure the non-commonalty of the vertices and correct for the error in orbit. SIM requires that the non-common vertex error (NCVE) of the double corner cube to be less than 6 (mu)m. The required accuracy for the knowledge of the NCVE is less than 1 (mu)m. This paper explains a method of measuring non-common vertices of a brassboard double corner cube with sub-micron accuracy. The results of such a measurement will be presented.

Space Interferometry Mission (SIM)↗

Astrophysics with Microarcsecond Accuracy Astrometry

Space-based astrometry promises to provide a powerful new tool for astrophysics. At a precision level of a few microarcsonds, a wide range of phenomena are opened up for study. In this paper we discuss the capabilities of the SIM Lite mission, the first space-based long-baseline optical interferometer, which will deliver parallaxes to 4 microarcsec. A companion paper in this volume will cover the development and operation of this instrument. At the level that SIM Lite will reach, better than 1 microarcsec in a single measurement, planets as small as one Earth can be detected around many dozen of the nearest stars. Not only can planet masses be definitely measured, but also the full orbital parameters determined, allowing study of system stability in multiple planet systems. This capability to survey our nearby stellar neighbors for terrestrial planets will be a unique contribution to our understanding of the local universe. SIM Lite will be able to tackle a wide range of interesting problems in stellar and Galactic astrophysics. By tracing the motions of stars in dwarf spheroidal galaxies orbiting our Milky Way, SIM Lite will probe the shape of the galactic potential history of the formation of the galaxy, and the nature of dark matter. Because it is flexibly scheduled, the instrument can dwell on faint targets, maintaining its full accuracy on objects as faint as V=19. This paper is a brief survey of the diverse problems in modern astrophysics that SIM Lite will be able to address.

SIM Science Team↗

Interlaboratory comparison of secondary ion mass spectrometry analysis results from the 7th international technical nuclear forensics working group collaborative material exercise

A review and interlaboratory comparison of secondary ion mass spectrometry (SIMS) data obtained by laboratories participating in the International Technical Nuclear Forensics Working Group (ITWG) 7th Collaborative Material Exercise (CMX-7) has been conducted. The analyzed materials were two uranium compounds in powder form and two pieces of uranium metal. The instruments used in this comparison were a small-geometry (SG) SIMS, CAMECA IMS 7f from the Research Centre Rez, and a large-geometry (LG) SIMS, CAMECA IMS 1280 from Los Alamos National Laboratory. Despite the differences in instruments and analytical procedures, e.g., sample preparation, SIMS setups, and data post-processing, there was good agreement for the 234 U/ 238 U, 235 U/ 238 U, and 236 U/ 238 U ratios in the analyzed materials. The main difference was in the precision, which was, as expected, higher for the LG-SIMS. In addition, a comparison between the laboratories was also made for the image processing algorithms applied to raw data acquired in automated particle measurement (APM) mode. In conclusion, the result of this comparison has led to identification of best practices for setting up parameters of the APM software.

and nuclear chemistry↗

A case study on the use of carbon sticky tabs for microbeam uranium isotope measurement with an emphasis on understanding the influence of subtle variations in substrate composition

In this paper we integrate laser induced breakdown spectroscopy (LIBS), large geometry secondary ion mass spectrometry (LG-SIMS), laser ablation—multi collector—inductively coupled plasma—mass spectrometry (LA-MC-ICP-MS), and trace elemental compositions obtained by bulk digestion from a suite of commercially available carbon sticky tabs to determine if subtle variations in the tab’s composition can be tied to shifts in the observed uranium isotopic composition of the IRMM-2020 standard relative to its ‘true’ value. The results suggest that, although clear differences exist in the relative abundances of carbon and hydrogen across the various carbon sticky tabs examined, as well as differences in their trace elemental and total uranium concentrations, these differences do not appear to influence the LG-SIMS or LA-MC-ICP-MS uranium isotope ratio measurements, or the appearance of the uranium mass spectrum scans. Instead, the quality (i.e., precision and accuracy) of the LG-SIMS and LA-MC-ICP-MS results are directly proportional to the observed signal intensity at the time of analysis. For the LG-SIMS measurements, there does appear to be a direct correlation between 235U1H hydride formation rates and vacuum conditions within the instrument’s analytical chamber. Furthermore, none of the carbon sticky tabs examined by LG-SIMS displayed evidence of elevated background uranium content. While a preliminary correlation was observed between the uranium isotope background signal during LA-MC-ICP-MS and the total uranium concentrations determined by isotope dilution, none of the tabs displayed a high enough analytical background to affect the isotope ratio measurements.

Zirakparvar, Alex [ORNL] (ORCID:0000000337797730)↗

Analysis of the Thermal Stability of Very Thin Surface Layers of Corrosion Inhibitors by Time-of-Flight Secondary Ion Mass Spectrometry

The powerful nature of the secondary ion mass spectrometry (SIMS) technique was explored in order to analyse very thin surface layers that were self-assembled on steel material from acidic solution. These surface layers are adsorbed corrosion inhibitors. The SIMS technique proved useful to characterise the molecular structure and homogeneity of thin surface layers in the nanometre range of specific analytes on the metallic substrate. Using SIMS, the thermal stability of these layers was further investigated and the desorption energy at a certain temperature was determined, where special attention was devoted to the method’s static limit. In order to compare, and for certain cases emphasise, the benefits gained by using SIMS in such surface analysis compared with the X-ray photoelectron spectroscopy (XPS) method, the same samples were also analysed by means of the latter. XPS is usually considered to be the most powerful analytical tool in surface analysis studies, but, as shown herein, it has certain limitations compared to SIMS. Finally, the surface topography was investigated by employing atomic force microscopy (AFM) in order to carry out a comprehensive surface analysis. .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Role of the SUMO-interacting motif in HIPK2 targeting to the PML nuclear bodies and regulation of p53

Homeodomain-interacting protein kinase 2 (HIPK2) is a key regulator of various transcription factors including p53 and CtBP in the DNA damage signaling pathway. PML-nuclear body (NB) is required for HIPK2-mediated p53 phosphorylation at Ser46 and induction of apoptosis. Although PML-NB targeting of HIPK2 has been shown, much is not clear about the molecular mechanism of HIPK2 recruitment to PML-NBs. Here we show that HIPK2 colocalizes specifically with PML-I and PML-IV. Mutational analysis showed that HIPK2 recruitment to PML-IV-NBs is mediated by the SUMO-interaction motifs (SIMs) of both PML-IV and HIPK2. Wild-type HIPK2 associated with SUMO-conjugated PML-IV at a higher affinity than with un-conjugated PML-IV, while the association of a HIPK2 SIM mutant with SUMO-modified PML-IV was impaired. In colony formation assays, HIPK2 strongly suppressed cell proliferation, but HIPK2 SIM mutants did not. In addition, activation and phosphorylation of p53 at the Ser46 residue were impaired by HIPK2 SIM mutants. These results suggest that SIM-mediated HIPK2 targeting to PML-NBs is crucial for HIPK2-mediated p53 activation and induction of apoptosis.

60 APPLIED LIFE SCIENCES↗

Three-Dimensional Mass Spectrometric Imaging of Biological Structures Using a Vacuum-Compatible Microfluidic Device

Three-dimensional (3D) molecular imaging of biological structures is important for a wide range of research. In recent decades, secondary ion mass spectrometry (SIMS) has been recognized as a powerful technique for both two-dimensional (2D) and 3D molecular imaging. Sample fixations (e. g., chemical fixation and cryogenic fixation methods) are necessary to adapt biological samples to the vacuum condition in the SIMS chamber, which has been demonstrated to be non-trivial and less controllable, thus limiting the wider application of SIMS on 3D molecular analysis of biological samples. Our group recently developed in situ liquid SIMS that offers great opportunities for the molecular study of various liquids and liquid interfaces. In this work, we demonstrate that a further development of the vacuum-compatible microfluidic device used in in situ liquid SIMS provides a convenient freeze-fixation of biological samples and leads to more controllable and convenient 3D molecular imaging. The special design of this new vacuum-compatible liquid chamber allows an easy determination of sputter rates of ice, which is critical for calibrating the depth scale of frozen biological samples. Sputter yield of a 20 keV Ar 1800 + ion on ice has been determined as 1500 (± 8%) water molecules per Ar 1800 + ion, consistent with our results from molecular dynamics simulations. Moreover, using the information of ice sputter yield, we successfully conduct 3D molecular imaging of frozen homogenized milk and observe network structures of interesting organic and inorganic species. Finally, taken together, our results will significantly benefit various research fields relying on 3D molecular imaging of biological structures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exploiting the Semidestructive Nature of Gas Cluster Ion Beam Time-of-Flight Secondary Ion Mass Spectrometry Imaging for Simultaneous Localization and Confident Lipid Annotations

Lipids have been considered as key players in cell signaling and disease. Information on their location and distribution within a biological system, under varying conditions, is necessary to understand the contributions of different lipid species to an altered phenotype. Imaging mass spectrometry techniques, such as time-of-flight secondary ion mass spectrometry (ToF-SIMS) and matrix-assisted laser desorption/ionization (MALDI), are capable of revealing global lipid distributions in tissues in an untargeted fashion. Yet, to confidently identify the species present in a sample, orthogonal analyses like tandem MS (MS/MS) are often required. This can be accomplished by bulk sample analysis with liquid chromatography (LC)-MS/MS, which can provide confident lipid identifications, at the expense of losing location-specific information. Here, using planarian flatworms as a model system, we demonstrate that imaging gas cluster ion beam (GCIB)-ToF-SIMS has the unique capability to simultaneously detect, identify, and image lipid species with subcellular resolution in tissue sections. The parallel detection of both, intact lipids and their respective fragments, allows for unique identification of some species without the need of performing an additional orthogonal MS/MS analysis. This was accomplished by correlating intact lipid and associated fragment SIMS images. The lipid assignments, respective fragment identities, and locations gathered from ToF-SIMS data were confirmed via LC-MS/MS on lipid extracts and ultrahigh mass resolution MALDI-MS imaging. Together, these data show that the semidestructive nature of ToF-SIMS can be utilized advantageously to enable both confident molecular annotations and to determine the locations of species within a biological sample.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measuring Compositions in Organic Depth Profiling: Results from a VAMAS Interlaboratory Study

We report the results of a VAMAS (Versailles Project on Advanced Materials and Standards) interlaboratory study on the measurement of composition in organic depth profiling. Layered samples with known binary compositions of Irganox 1010 and either Irganox 1098 or Fmoc-pentafluoro-L-phenylalanine in each layer were manufactured in a single batch and distributed to more than 20 participating laboratories. The samples were analyzed using argon cluster ion sputtering and either X-ray Photoelectron Spectroscopy (XPS) or Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) to generate depth profiles. Participants were asked to estimate the volume fractions in two of the layers and were provided with the compositions of all other layers. Participants using XPS provided volume fractions within 0.03 of the nominal values. Participants using ToF-SIMS either made no attempt, or used various methods that gave results ranging in error from 0.02 to over 0.10 in volume fraction, the latter representing a 50% relative error for a nominal volume fraction of 0.2. Error was predominantly caused by inadequacy in the ability to compensate for primary ion intensity variations and the matrix effect in SIMS. Matrix effects in these materials appear to be more pronounced as the number of atoms in both the primary analytical ion and the secondary ion increase. Using the participants’ data we show that organic SIMS matrix effects can be measured and are remarkably consistent between instruments. We provide recommendations for identifying and compensating for matrix effects. Finally we demonstrate, using a simple normalization method, that virtually all ToF-SIMS participants could have obtained estimates of volume fraction that were at least as accurate and consistent as XPS.

Environmental Molecular Sciences Laboratory↗