Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sample”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Single-Use Destructive Assay for Uranium Hexafluoride Sampling

Sampling uranium hexafluoride (UF6) for the determination of enrichments by destructive analysis (DA) is a critical component in the International Atomic Energy Agency’s layered safeguards approach for uranium processing facilities. Typically, gram-quantity UF6 samples are collected during inspections and stored under tag-and-seal until transportation to an off-site analytical laboratory. The shipping times can be long, and evolving restrictions on radioactive/corrosive materials shipments may increasingly limit the IAEA’s ability to transport UF6 samples easily. Pacific Northwest National Laboratory has developed a low-cost UF6 sampling technology called Single-Use Destructive Assay (SUDA) that addresses these challenges, as well as provides DA sample geometries that can be tailored for different analytical methods, including potential on-site analyses. The SUDA samplers, along with a unique holder, are designed for direct attachment to existing taps at uranium processing facilities, allowing gaseous UF6 to come into direct contact with a zeolite film. The SUDA technology features the ability to capture uranium in a more easily shipped and handled form as the solid, more stable, and relatively less hazardous hydrated uranyl fluoride (UO2F2•nH2O), which is formed through the controlled hydrolysis of UF6. We have recently simulated uranium collection under enrichment plant sampling conditions to further improve our understanding of SUDA sampling. Presented here is our recent work on measuring the relationship between sampling conditions and uranium collection, which includes control of the uranium-mass-to-zeolite ratio and assessing variable UF6 gas and sampling parameters that can affect collection using the SUDA sampler.

Pope, Timothy R.↗

Data Report on Post-Irradiation Dimensional Change of AGC-1 Samples

This report documents the measured post irradiation dimensional change in the AGC-1 samples. The AGC-1 capsule is the first in six planned irradiation capsules comprising the Advanced Graphite Creep (AGC) test series. AGC-1 irradiation began September 5, 2009 in the Advanced Test Reactor (ATR) and was completed on January 8, 2011. The capsule was cooled for 3 months in the ATR Canal, and then shipped to MFC in April 2011 for disassembly and sample extraction. After extraction the samples were shipped to the INL Research Center (IRC) for initial post-irradiation examination (PIE) and storage in the irradiated graphite vault. The AGC-1 capsule design contained “matched pair” samples to ascertain the irradiation-induced dimensional changes and levels of creep experienced in different graphite types. The irradiation-induced dimensional changes and creep levels are determined by comparing the total dimensional change for stressed and unstressed samples of the same type of graphite exposed to the same dose levels and at similar temperatures. Under irradiation creep (i.e. permanent strain due to irradiation, stress, and temperature) the stressed samples should demonstrate more dimensional change than the unstressed samples. This additional dimensional change in the stressed samples is designated as “irradiation-induced creep” in graphite. The data are further presented using the parameters influencing dimensional change in graphite; levels of induced stress, temperature, graphite type, and dose. However, the AGC-1 post-irradiation examination is a significant endeavor and this data report serves to provide irradiation-induced dimensional change data for AGC capsule design refinement as well as a status on the progress of the PIE activities. The dimensional changes of both the samples and graphite body are very important to the design of the future AGC capsules (AGC-3 through AGC-6) and are provided as soon as the data are available in order to determine whether design changes to the next capsule are required. A complete evaluation of the irradiation-induced dimensional change data will be performed for a final AGC-1 PIE report that will include full analysis of pre- and post-irradiation data, with verified AGC-1 irradiation conditions of temperature and dose.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Per-instruction energy debugging using instruction sampling hardware

A processor utilizes instruction based sampling to generate sampling data sampled on a per instruction basis during execution of an instruction. The sampling data indicates what processor hardware was used due to the execution of the instruction. Software receives the sampling data and generates an estimate of energy used by the instruction based on the sampling data. The sampling data may include microarchitectural events and the energy estimate utilizes a base energy amount corresponding to the instruction executed along with energy amounts corresponding to the microarchitectural events in the sampling data. The sampling data may include switching events associated with hardware blocks that switched due to execution of the instruction and the energy estimate for the instruction is based on the switching events and capacitance estimates associated with the hardware blocks.

Wei, Shijia↗

Prompt Gamma Ray Analysis of Soil Samples

Neutron moderation effects were measured in bulk soil samples through prompt gamma ray measurements from water and benzene contaminated soil samples using 14 MeV neutron inelastic scattering. The prompt gamma rays were measured using a cylindrical 76 mm x 76 mm (diameter x height) LaBr{sub 3}:Ce detector. Since neutron moderation effects strongly depend upon hydrogen concentration of the sample, for comparison purposes, moderation effects were studied from samples containing different hydrogen concentrations. The soil samples with different hydrogen concentration were prepared by mixing soil with water as well as benzene in different weight proportions. Then, the effects of increasing water and benzene concentrations on the yields of hydrogen, carbon and silicon prompt gamma rays were measured. Moderation effects are more pronounced in soil samples mixed with water as compared to those from soil samples mixed with benzene. This is due to the fact that benzene contaminated soil samples have about 30% less hydrogen concentration by weight than the water contaminated soil samples. Results of the study will be presented. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SNS Sample Activation Calculator Experimental Validation - Paper 79

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) uses the Sample Activation Calculator (SAC) to calculate the activation of all samples after they have been exposed to the neutron beam in any of the neutron scattering instruments at the SNS beamlines. The SAC web page takes user inputs (choice of beamline, the mass, composition and area of the sample, irradiation time, decay time, etc.) and then calculates the activation for the sample. In recent years, the SAC has been incorporated into the user proposal and sample handling process, and beamline scientists and users have noticed discrepancies in the predicted activation of their samples. As a part of the Neutronics Analysis Group at SNS, we were tasked with validating the SAC tool and diagnosing the origin of the discrepancies seen by the beamline scientists and the users. In the process of performing these measurements, we additionally found that several aspects of realistic neutron scattering operations, and thus sample exposure, cannot be captured with current configuration of the SAC tool. Typical neutron scattering samples are irradiated for multiple periods with different neutron energy ranges; the realities of accelerator operation indicate that not all of those periods will be at the same accelerator power, and scattering samples are frequently not fully illuminated by the well-collimated neutron beam. Finally, we will explore whether neutron beams, as modified by neutron guide systems with energy-dependent intensity modifications and by precise energy-band defining mechanical choppers, are suitably analyzed with multigroup cross section libraries in which there are typically very few energy groups below one eV. (authors)

43 PARTICLE ACCELERATORS↗

WHOLESCALE Catalog of Rock Samples at San Emidio Nevada collected in January 2021

This submission contains information on thirty-six rock samples collected from San Emidio, Nevada during January, 2021 for Subtask 2.3 of the WHOLESCALE project. The following resources include a .zip of rock sample photos taken in the field, a .zip of rock sample photos taken in the laboratory at UW-Madison, and an excel catalog of rock samples with information on sample name, rock type, coordinates of sample location, structural measurements, field notes, observations for plug preparation (e.g., weathering, ability to be cut and cored), and rock descriptions. It should be noted that not every sample was photographed in the field. Names and descriptions of rock formation units are taken from Rhodes et al. (2011). The README.txt file is a description of this submission.

15 GEOTHERMAL ENERGY↗

Determining the Optimum Number of Increments in Composite Sampling

Composite sampling can be more cost effective than simple random sampling. This paper considers how to determine the optimum number of increments to use in composite sampling. Composite sampling can be more cost effective than simple random sampling. This paper considers how to determine the optimum number of increments to use in composite sampling. Composite sampling terminology and theory are outlined and a method is developed which accounts for different sources of variation in compositing and data analysis. This method is used to define and understand the process of determining the optimum number of increments that should be used in forming a composite. The blending variance is shown to have a smaller range of possible values than previously reported when estimating the number of increments in a composite sample. Accounting for differing levels of the blending variance significantly affects the estimated number of increments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated sample-handling and mounting system for fixed-target serial synchrotron crystallography

Serial synchrotron crystallography (SSX) is enabling the efficient use of small crystals for structure–function studies of biomolecules and for drug discovery. An integrated SSX system has been developed comprising ultralow background-scatter sample holders suitable for room and cryogenic temperature crystallographic data collection, a sample-loading station and a humid `gloveless' glovebox. The sample holders incorporate thin-film supports with a variety of designs optimized for different crystal-loading challenges. These holders facilitate the dispersion of crystals and the removal of excess liquid, can be cooled at extremely high rates, generate little background scatter, allow data collection over >90° of oscillation without obstruction or the risk of generating saturating Bragg peaks, are compatible with existing infrastructure for high-throughput cryocrystallography and are reusable. The sample-loading station allows sample preparation and loading onto the support film, the application of time-varying suction for optimal removal of excess liquid, crystal repositioning and cryoprotection, and the application of sealing films for room-temperature data collection, all in a controlled-humidity environment. The humid glovebox allows microscope observation of the sample-loading station and crystallization trays while maintaining near-saturating humidities that further minimize the risks of sample dehydration and damage, and maximize working times. This integrated system addresses common problems in obtaining properly dispersed, properly hydrated and isomorphous microcrystals for fixed-orientation and oscillation data collection. Its ease of use, flexibility and optimized performance make it attractive not just for SSX but also for single-crystal and few-crystal data collection. Fundamental concepts that are important in achieving desired crystal distributions on a sample holder via time-varying suction-induced liquid flows are also discussed.

47 OTHER INSTRUMENTATION↗

EMP Attachment 1: DOE-SC PNNL Site Sampling and Analysis Plan

This Sampling and Analysis Plan (SAP) is written for the radiological environmental air surveillance program for the DOE-SC PNNL Site, Richland Washington. It provides the requirements for planning sampling events, and the requirements imposed on the analytical laboratory analyzing the air samples. The actual air sampling process is in procedure EPRP-AIR-029. The rationale for analyte selection, media, and sampling site location has been vetted through the data quality objectives (DQO) process (Barnett et al. 2010). The results from the DQO process have been reviewed and approved by the Washington State Department of Health. The DQO process (Barnett et al. 2010) identified seven specific radionuclides for analysis along with the need for gross alpha and gross beta radiological analyses. The analytes are 241<\sup>Am, 243<\sup>Am, 244<\sup>Cm, 60<\sup>Co, 238<\sup>Pu, 239<\sup>Pu, and 233<\sup>U. The report also determined that air samples for particulates are the only sample matrix required for the monitoring program. These samples are collected on 47-mm glass-fiber filters.

54 ENVIRONMENTAL SCIENCES↗

Underground Test Area Calendar Year 2014 Annual Sampling Analysis Report Nevada National Security Site, Nevada, Revision 0

This report presents the analytical data for the 2014 fiscal year (FY) and calendar year (CY) (October 1, 2013, through December 31, 2014), and an evaluation of the data to ensure that the Sampling Plan’s objectives are met. In addition to samples collected and analyzed for the Sampling Plan, some NNSS wells are monitored by NNSA/NFO to demonstrate compliance with State-issued water discharge permits; with protection of groundwater from ongoing radiological waste disposal activities (compliance wells); and to demonstrate that the onsite drinking water supply is below SDWA maximum contaminant levels (MCLs) (public water system [PWS] wells). While not all sampled locations are required by the Sampling Plan, these samples are relevant to its objectives and are therefore presented herein for completeness purposes. Special investigations that took place in 2014 that are relevant to the Sampling Plan are also presented. This is the first annual report released to support Sampling Plan implementation.

54 ENVIRONMENTAL SCIENCES↗

Hanford Site Environmental Surveillance Master Sampling Schedule for Calendar Year 2010

Environmental surveillance of the Hanford Site and surrounding areas is conducted by Pacific Northwest National Laboratory for the U.S. Department of Energy (DOE). Sampling is conducted to evaluate levels of radioactive and nonradioactive pollutants in the Hanford Site environs per regulatory requirements. This document contains the calendar year 2010 schedule for the routine collection of samples for the Surface Environmental Surveillance Project and the Drinking Water Monitoring Project. Each section includes sampling locations, sampling frequencies, sample types, and analyses to be performed. In some cases, samples are scheduled on a rotating basis. If a sample will not be collected in 2010, the anticipated year for collection is provided. Maps showing approximate sampling locations are included for media scheduled for collection in 2010.

54 ENVIRONMENTAL SCIENCES↗

Adrenal Venous Sampling: Where Is the Aldosterone Disappearing to?

Adrenal venous sampling (AVS) is generally considered to be the gold standard in distinguishing unilateral and bilateral aldosterone hypersecretion in primary hyperaldosteronism. However, during AVS, we noticed a considerable variability in aldosterone concentrations among samples thought to have come from the right adrenal glands. Some aldosterone concentrations in these samples were even lower than in samples from the inferior vena cava. We hypothesized that the samples with low aldosterone levels were unintentionally taken not from the right adrenal gland, but from hepatic veins. Therefore, we sought to analyze the impact of unintentional cannulation of hepatic veins on AVS. Thirty consecutive patients referred for AVS were enrolled. Hepatic vein sampling was implemented in our standardized AVS protocol. The data were collected and analyzed prospectively. AVS was successful in 27 patients (90%), and hepatic vein cannulation was successful in all procedures performed. Cortisol concentrations were not significantly different between the hepatic vein and inferior vena cava samples, but aldosterone concentrations from hepatic venous blood (median, 17 pmol/l; range, 40-860 pmol/l) were markedly lower than in samples from the inferior vena cava (median, 860 pmol/l; range, 460-4510 pmol/l). The observed difference was statistically significant (P < 0.001). Aldosterone concentrations in the hepatic veins are significantly lower than in venous blood taken from the inferior vena cava. This finding is important for AVS because hepatic veins can easily be mistaken for adrenal veins as a result of their close anatomic proximity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

How to avoid multiple scattering in strongly scattering SANS and USANS samples

Small Angle Neutron Scattering (SANS) and Ultra Small Angle Neutron Scattering (USANS) are the only available experimental techniques to provide seamless non-destructive measurements of the geometry of the accessible and inaccessible pore structure of rocks from sub-nanopore size to the scale of macropores. They have therefore become the measurement of choice for tight reservoir rocks such as organic rich shales. A simplifying assumption in the analysis is, however, that during the path of neutrons through the sample each neutron is only scattered once. Shales are samples with a high scattering power and Multiple Scattering (MS) may occur which requires special modelling for deconvolution of the results. The approach to avoid MS is to simply reduce the sample thickness to <0.15–0.5 mm. Here, in this work, we present a systematic method on wavelength selection and preparation of samples to optimise extraction of microstructural data and minimise parasitic errors. Experimentally measured SAS transmission (TSAS) values are used as a practical criterion for estimation of the extent of MS. Generous beamtime allocations allowed robust testing revealing that sample thicknesses can be twice as thick as predicted using the standard protocol. Analysing thicker samples is particularly beneficial for statistically relevant characterisation of heterogeneous samples making the new protocol the method of choice for such samples.

(U)SANS↗

Hybrid nested sampling algorithm for Bayesian model selection applied to inverse subsurface flow problems

A Hybrid Nested Sampling (HNS) algorithm is proposed for efficient Bayesian model calibration and prior model selection. The proposed algorithm combines, Nested Sampling (NS) algorithm, Hybrid Monte Carlo (HMC) sampling and gradient estimation using Stochastic Ensemble Method (SEM). NS is an efficient sampling algorithm that can be used for Bayesian calibration and estimating the Bayesian evidence for prior model selection. Nested sampling has the advantage of computational feasibility. Within the nested sampling algorithm, a constrained sampling step is performed. For this step, we utilize HMC to reduce the correlation between successive sampled states. HMC relies on the gradient of the logarithm of the posterior distribution, which we estimate using a stochastic ensemble method based on an ensemble of directional derivatives. SEM only requires forward model runs and the simulator is then used as a black box and no adjoint code is needed. The developed HNS algorithm is successfully applied for Bayesian calibration and prior model selection of several nonlinear subsurface flow problems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Adversarial sampling of unknown and high-dimensional conditional distributions

Many engineering problems require the prediction of realization-to-realization variability or a refined description of modeled quantities. In that case, it is necessary to sample elements from unknown high-dimensional spaces with possibly millions of degrees of freedom. While there exist methods able to sample elements from probability density functions (PDF) with known shapes, several approximations need to be made when the distribution is unknown. In this paper the sampling method, as well as the inference of the underlying distribution, are both handled with a data-driven method known as generative adversarial networks (GAN), which trains two competing neural networks to produce a network that can effectively generate samples from the training set distribution. In practice, it is often necessary to draw samples from conditional distributions. When the conditional variables are continuous, only one (if any) data point corresponding to a particular value of a conditioning variable may be available, which is not sufficient to estimate the conditional distribution. This work handles this problem using an a priori estimation of the conditional moments of a PDF. Herein, two approaches, stochastic estimation, and an external neural network are compared for computing these moments; however, any preferred method can be used. The algorithm is demonstrated in the case of the deconvolution of a filtered turbulent flow field. It is shown that all the versions of the proposed algorithm effectively sample the target conditional distribution with minimal impact on the quality of the samples compared to state-of-the-art methods. Additionally, the procedure can be used as a metric for the diversity of samples generated by a conditional GAN (cGAN) conditioned with continuous variables.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Influence of sampling frequency and estimation method on phosphorus load uncertainty in the Western Lake Erie Basin, Ohio, USA

Accurate estimates of nutrient loads are necessary to identify critical source areas and quantify the impact of management practices on pollutant export. Previous studies have investigated nutrient load estimate uncertainty, but they often focus on nutrient loads estimated using an interpolation method for large-scale watersheds with short-term datasets. The study objective was to quantify uncertainty in soluble reactive phosphorus (SRP), total phosphorus (TP), and suspended solids (SS) load estimates from two small (<10 3 km 2 ) agricultural watersheds in the western Lake Erie Basin resulting from different sampling frequencies. Each watershed had high temporal resolution datasets of discharge (15 min) and nutrient concentration (1 to 3 samples per day) collected over a 30-year period (1990–2020). Firstly, SRP, TP, and SS loads were calculated using the high temporal resolution datasets, which was assumed as “true loads”. Secondly, the high temporal concentration data were decomposed to semiweekly, weekly, biweekly, and monthly sampling and annual loads were estimated using four common load estimation methods to assess the effect of sampling frequency and load estimation method on load estimate error. Across the four different methods, the composite method had the lowest relative root mean square and absolute bias, but the rectangular interpolation method was the most precise. Furthermore, even with semiweekly sampling, the composite method resulted in an unacceptable level of precision (average imprecision = 39 %), while the interpolation method resulted in an unacceptable bias (average absolute bias = 16 %). Because neither method could provide acceptable accuracy and precision at the lowest decrease in sampling (e.t. semiweekly sampling), continued daily sampling is recommended in these watersheds.

54 ENVIRONMENTAL SCIENCES↗

A multi-threshold sampling method for TOF PET signal processing

As an approach to realizing all-digital data acquisition for positron emission tomography (PET), we have previously proposed and studied a multithreshold sampling method to generate samples of a PET event waveform with respect to a few user-defined amplitudes. In this sampling scheme, one can extract both the energy and timing information for an event. In this paper, we report our prototype implementation of this sampling method and the performance results obtained with this prototype. The prototype consists of two multi-threshold discriminator boards and a time-to-digital converter (TDC) board. Each of the multi-threshold discriminator boards takes one input and provides up to 8 threshold levels, which can be defined by users, for sampling the input signal. The TDC board employs the CERN HPTDC chip that determines the digitized times of the leading and falling edges of the discriminator output pulses. We connect our prototype electronics to the outputs of two Hamamatsu R9800 photomultiplier tubes (PMTs) that are individually coupled to a 6.25 x 6.25 x 25mm{sup 3} LSO crystal. By analyzing waveform samples generated by using four thresholds, we obtain a coincidence timing resolution of about 340 ps and an {approx}18% energy resolution at 511 keV. We are also able to estimate the decay-time constant from the resulting samples and obtain a mean value of 44 ns with an {approx}9 ns FWHM. In comparison, using digitized waveforms obtained at a 20 GSps sampling rate for the same LSO/PMT modules we obtain {approx}300 ps coincidence timing resolution, {approx}14% energy resolution at 511 keV, and {approx}5 ns FWHM for the estimated decay-time constant. Details of the results on the timing and energy resolutions by using the multi-threshold method indicate that it is a promising approach for implementing digital PET data acquisition.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combining Laser Ablation/Liquid Phase Collection Surface Sampling and High-Performance Liquid Chromatography Electrospray Ionization Mass Spectrometry

This paper describes the coupling of ambient pressure transmission geometry laser ablation with a liquid phase sample collection method for surface sampling and ionization with subsequent mass spectral analysis. A commercially available autosampler was adapted to produce a liquid droplet at the end of the syringe injection needle while in close proximity to the surface to collect the sample plume produced by laser ablation. The sample collection was followed by either flow injection or a high performance liquid chromatography (HPLC) separation of the extracted components and detection with electrospray ionization mass spectrometry (ESI-MS). To illustrate the analytical utility of this coupling, thin films of a commercial ink sample containing rhodamine 6G and of mixed isobaric rhodamine B and 6G dyes on glass microscope slides were analyzed. The flow injection and HPLC/ESI-MS analysis revealed successful laser ablation, capture and, with HPLC, the separation of the two compounds. The ablated circular area was about 70 m in diameter for these experiments. The spatial sampling resolution afforded by the laser ablation, as well as the ability to use sample processing methods like HPLC between the sample collection and ionization steps, makes this combined surface sampling/ionization technique a highly versatile analytical tool.

Laser Ablation↗