Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sampling device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Optimizing performance and yield of vertical GaN diodes using wafer scale optical techniques

Abstract To improve the manufacturing of vertical GaN devices for power electronics applications, the effects of defects in GaN substrates need to be better understood. Many non-destructive techniques including photoluminescence, Raman spectroscopy and optical profilometry, can be used to detect defects in the substrate and epitaxial layers. Raman spectroscopy was used to identify points of high crystal stress and non-uniform conductivity in a substrate, while optical profilometry was used to identify bumps and pits in a substrate which could cause catastrophic device failures. The effect of the defects was studied using vertical P-i-N diodes with a single zone junction termination extention (JTE) edge termination and isolation, which were formed via nitrogen implantation. Diodes were fabricated on and off of sample abnormalities to study their effects. From electrical measurements, it was discovered that the devices could consistently block voltages over 1000 V (near the theoretical value of the epitaxial layer design), and the forward bias behavior could consistently produce on-resistance below 2 mΩ cm 2 , which is an excellent value considering DC biasing was used and no substrate thinning was performed. It was found that high crystal stress increased the probability of device failure from 6 to 20%, while an inhomogeneous carrier concentration had little effect on reverse bias behavior, and slightly (~ 3%) increased the on-resistance (R on ). Optical profilometry was able to detect regions of high surface roughness, bumps, and pits; in which, the majority of the defects detected were benign. However a large bump in the termination region of the JTE or a deep pit can induce a low voltage catastrophic failure, and increased crystal stress detected by the Raman correlated to the optical profilometry with associated surface topography.

42 ENGINEERING↗

Filtering device

An electrical filter for removing noise from a voice communications signal is reported; seven sample values of the signal are obtained continuously, updated and subjected to filtering. Filtering is accomplished by adding balanced, with respect to a mid-point sample, spaced pairs of the sampled values, and then multiplying each pair by a selected filter constant. The signal products thus obtained are summed to provide a filtered version of the original signal.

Edwards, T. R.↗

Balanced mechanical resonator for powder handling device

A system incorporating a balanced mechanical resonator and a method for vibration of a sample composed of granular material to generate motion of a powder sample inside the sample holder for obtaining improved analysis statistics, without imparting vibration to the sample holder support.

Sarrazin, Philippe C.↗

Initial Benchmarks of UV LEDs and Comparisons with White LEDs

The primary goal of this report is to benchmark the initial level of performance of a selection of commercial UV LEDs across all three bands (i.e., UV-A, UV-B, UV-C). To provide the initial performance benchmarks, a test matrix containing 13 different UV LED products was created in association with the LED Systems Reliability Consortium (LSRC). The products in this test matrix were all commercially available as of June 2021, and at least 22 samples of each product were tested. In addition, two common, commercial white LEDs were tested to provide a benchmark against blue-pumped white LEDs. Testing of the samples included electrical performance testing (e.g., current-voltage measurements) and photometric testing in a calibrated integrating sphere capable of measuring devices in the UV-A, UV-B, and UV-C bands. The electrical testing provided insights into the performance of the semiconductor layers in the LEDs, allowing parameters such as the threshold voltage (V th ) and serial resistance (R serial ) of each sample to be determined. The photometric testing provided insights into emission wavelengths, peak shapes, and radiant efficiencies for each sample. Combined, the information from these tests permits the overall device efficiencies to be compared and provides insights into the electrical and optical performance of the technology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Addressing the Stability Gap in Photoelectrochemistry: Molybdenum Disulfide Protective Catalysts for Tandem III–V Unassisted Solar Water Splitting

While photoelectrochemical (PEC) solar-to-hydrogen efficiencies have greatly improved over the past few decades, advances in PEC durability have lagged behind. Corrosion of semiconductor photoabsorbers in the aqueous conditions needed for water splitting is a major challenge that limits device stability. In addition, a precious-metal catalyst is often required to efficiently promote water splitting. In this work, we demonstrate unassisted water splitting using a nonprecious metal molybdenum disulfide nanomaterial catalytic protection layer paired with a GaInAsP/GaAs tandem device. This device was able to achieve stable unassisted water splitting for nearly 12 h, while a sibling sample with a PtRu catalyst was only stable for 2 h, highlighting the advantage of the nonprecious metal catalyst. In situ optical imaging illustrates the progression of macroscopic degradation that causes device failure. Furthermore, this work compares unassisted water splitting devices across the field in terms of the efficiency and stability, illustrating the need for improved stability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Batch Gas-Sampling System

Sampler collects air or other gases in consistent way and stabilizes them for later chemical analysis. Device used for concentrations ranging from few parts per million to 100 percent. Also separates and collects particles in gas for analysis. Gas flows into vacuum sphere when solenoid valve opened. As it passes through conversion tube, constituent of gas forms stable compound that remains in conversion tube for analysis at later time. Sampler parts made of glass, polytetrafluoroethylene, and stainless steel so they do not react with sample.

Diaz, Vernon, Jr.↗

Layer-by-layer assembly of a [Fe-(pyrazine){Pd(CN) 4 }] spin crossover thin film

Abstract [Fe-(pyrazine){Pd(CN) 4 }] (pyrazine = pz) thin films were fabricated using a layer-by-layer assembly approach, a method known to be tunable, versatile, and scalable, since thin films are better-suited for industrial applications. In this study, [Fe-(pz){Pd(CN) 4 }] powder was synthesized, and the results obtained from a vibrating sample magnetometer verified the presence of an abrupt hysteresis loop with widths of 45 K centered around 300 K, indicating good cooperativity. Super conducting quantum interference device magnetometry results indicated a slow spin transition with temperature but with evidence of hysteresis for thin film samples. X-ray absorption analysis provided further support of the spin crossover behavior but differs from the magnetometry because the spin state transition at the surface differs from the bulk of the thin film. X-ray photoelectron spectroscopy provided some insight into issues with the film deposition process and multiplex fitting was used to further support the claim that the surface of the film is different than the bulk of the film.

McElveen, Kayleigh A. (ORCID:0000000210302913)↗

Lunar rock splitter/can sealer

A manually powered and operated force generating device fractures lunar material as received from the moon and seals cans containing lunar samples. The rock splitting and can sealing operations are carried out in a vacuum environment. Can sealing is a cold welding process that requires a pressure of 125,000 psi (generating 32,000 lb for the largest can used). The design and modification of the device and the operating experience are described.

Johnson, K. G.↗

Transport Powder and Liquid Samples by Surface Acoustic Waves

Sample transport is an important requirement for In-situ analysis of samples in NASA planetary exploration missions. Tests have shown that powders or liquid drops on a surface can be transported by surface acoustic waves (SAW) that are generated on the surface using interdigital transducers. The phenomena were investigated experimentally and to generate SAWs interdigital electrodes were deposited on wafers of 128 deg rotated Y-cut LiNbO?. Transporting capability of the SAW device was tested using particles of various sizes and drops of various viscosities liquids. Because of different interaction mechanisms with the SAWs, the powders and the liquid drops were observed to move in opposite directions. In the preliminary tests, a speed of 180 mm/s was achieved for powder transportation. The detailed experimental setup and results are presented in this paper. The transporting mechanism can potentially be applied to miniaturize sample analysis system or " lab-on-chip" devices.

Sample handling↗

Autonomous Measurement of Electrochemical Redox Couples for In-Situ Characterization of Enceladus Plume Samples

A 3D-printed microfluidic electrochemical cell with integrated electrodes was developed to demonstrate autonomous in-situ electrochemical characterization of terrestrial seawater samples. The system is designed to extend the capabilities of the 2008 Phoenix Lander’s Wet Chemistry Laboratory (WCL) that analyzed the soluble chemistry of the Martian soil, by miniaturizing its fluidic architecture for analysis of µL-volume samples as expected from an Enceladus fly-by mission. The microfluidic device has a total fluid volume of 48 µL and includes dual channels each populated with 7 electrodes. Measurement of pH was measured using an iridium oxide electrode. Cyclic voltammetry with Au, Pt, and glassy carbon working electrodes was used to measure redox couples in synthetic seawater that contained inorganic and bio-organic molecules. Glassy carbon was found to have minimal risk of interference from constituents of synthetic seawater when measuring molecular organic redox species; however, care must be used to prevent interference due to potential oxidation or dissolution in the case of Au working electrodes. A completely autonomous end-to-end run including sample delivery was performed, to demonstrate the feasibility of microfluidic-based cyclic voltammetry measurements for in-situ characterization of redox couples in Ocean World samples.

Planetary Instruments↗

In Situ Analysis of Organics with a Portable Mass Spectrometer

The search for extra-terrestrial life starts at home. In order to find life on other planets, we start by examining life processes we understand on the earth. Though it may not be possible to see the life in the form of macroscopic organisms, telltale signs of life can exist in the form of small organic molecules such as peptides and amino acids. Our overall goal is to test a portable mass spectrometer (MS) system, the Mini 10.5, for astrobiological applications including in situ hydrocarbon analysis and sediments analysis using an additional automated sample processing system (ASPS). The collaborative research focuses on two current projects in the field of astrobiology. Both projects are geared towards examining organics distributed in extreme environments. One portion of study attempts to qualitatively analyze the effect of volatile organic compounds (VOC) produced by diesel exhaust on lichens growing in the desert. This requires measurements to be taken by bringing the instrument to the Mojave Desert and monitoring atmospheric composition of VOCs in situ. The second project is to evaluate the miniature MS system as a detector for the ASPS extraction system. A major obstacle of any chemometric in situ analysis is the suppression of analyte signal by concomitant signal from the surrounding environment. The ASPS extraction device has been developed at JPL to extract amino acids from sediment samples and elute them in solution. The solution is eluted at a high pH and needs to be conditioned to a more neutral pH so that dissolved amino acids can be readily protonated and subsequently analyzed by electrospray MS.

astrobiology↗

Dean vortex-enhanced blood plasma separation in self-driven spiral microchannel flow with cross-flow microfilters

Point-of-care (POC) diagnostic devices have been developing rapidly in recent years, but they are mainly using saliva instead of blood as a test sample. A highly efficient self-separation during the self-driven flow without power systems is desired for expanding the point-of-care diagnostic devices. Microfiltration stands out as a promising technique for blood plasma separation but faces limitations due to blood cell clogging, resulting in reduced separation speed and efficiency. These limitations are mainly caused by the high viscosity and hematocrit in the blood flow. A small increment in the hematocrit of the blood significantly increases the pressure needed for the blood plasma separation in the micro-filters and decreases the separation speed and efficiency. Addressing this challenge, this study explores the feasibility of diluting whole blood within a microfluidic device without external power systems. This study implemented a spiral microchannel utilizing the inertial focusing and Dean vortex effects to focus the red blood cells and extract the blood with lower hematocrit. The inertial migration of the particles during the capillary flow was first investigated experimentally; a maximum of 88% of the particles migrated to the bottom and top equilibrium positions in the optimized 350 × 60 μm (cross-sectional area, 5.8 aspect ratio) microchannel. With the optimized dimension of the microchannel, the whole blood samples within the physiological hematocrit range were tested in the experiments, and more than 10% of the hematocrit reduction was compared between the outer branch outlet and inner branch outlet in the 350 × 60 μm microchannel.

Biochemistry & Molecular Biology↗

Microfluidics, Chromatography, and Atomic-Force Microscopy

A Raman-and-atomic-force microscope (RAFM) has been shown to be capable of performing several liquid-transfer and sensory functions essential for the operation of a microfluidic laboratory on a chip that would be used to perform rapid, sensitive chromatographic and spectro-chemical analyses of unprecedentedly small quantities of liquids. The most novel aspect of this development lies in the exploitation of capillary and shear effects at the atomic-force-microscope (AFM) tip to produce shear-driven flow of liquids along open microchannels of a microfluidic device. The RAFM can also be used to perform such functions as imaging liquids in microchannels; removing liquid samples from channels for very sensitive, tip-localized spectrochemical analyses; measuring a quantity of liquid adhering to the tip; and dip-pen deposition from a chromatographic device. A commercial Raman-spectroscopy system and a commercial AFM were integrated to make the RAFM so as to be able to perform simultaneous topographical AFM imaging and surface-enhanced Raman spectroscopy (SERS) at the AFM tip. The Raman-spectroscopy system includes a Raman microprobe attached to an optical microscope, the translation stage of which is modified to accommodate the AFM head. The Raman laser excitation beam, which is aimed at the AFM tip, has a wavelength of 785 nm and a diameter of about 5 m, and its power is adjustable up to 10 mW. The AFM is coated with gold to enable tip-localized SERS.

Anderson, Mark↗

Towards additive manufacturing of magnetocaloric working materials

The feasibility of three-dimensional printing via the Directed Energy Deposition (DED) technique is demonstrated for the ferromagnetic AlFe 2 B 2 (aka 1-2-2) compound, which shows promise as a working material for room-temperature magnetocaloric devices. Like many intermetallic materials, the 1-2-2 compound is brittle at room temperature; not only is it difficult to synthesize from the melt, it is challenging to form it into useful geometries necessary for effective heat transfer in magnetocaloric devices. Using Laser Engineered Net Shaping (LENS TM ) synthesis from two powder precursors, AlB 2 and Fe, samples of simple (rod) and complex (honeycomb) architectures were successfully synthesized. Furthermore, the phase constitution and distribution, magnetic transition temperature, and saturation magnetization determined for the LENS TM -synthesized rod sample are all similar to those obtained for 1-2-2 materials made by conventional casting. Further, the measured magnetic entropy change, as determined from Maxwell's Relations applied to magnetic data, indicates that the magnetocaloric response of the annealed LENS TM -printed rod samples are comparable to those of the 1-2-2 compounds made by conventional techniques. These results confirm that complex magnetofunctional shapes, which are needed for efficient energy conversion in magnetocaloric devices, can be rapidly fabricated from the AlFe 2 B 2 compound.

36 MATERIALS SCIENCE↗

CCD correlated quadruple sampling processor

A correlated quadruple sampling processor for improved signal-to-noise ratio in the output of a charge-coupled device (CCD) is comprised of: switching means for momentarily clamping a CCD signal line at a first reference level A before a CCD data pulse and then obtaining a first data sample B with respect to the reference A during a CCD data pulse, and storing the positive sample B-A; switching means for momentarily clamping the CCD signal line a second time at the level C during the presence of the CCD data pulse and then obtaining a second data sample D with respect to the reference level C after the CCD data pulse, and storing the negative sample D-C; and means for obtaining the difference between the stored samples +(B-A) and -(D-C), thus increasing the net signal amplitude by a factor of about 2 while the noise would be increased by only a factor of square root of 2 since there will be no correlation in the noise between the double samples +(B-A) and -(D-C) effectively added.

Gaalema, S. D.↗

Group-theoretic error mitigation enabled by classical shadows and symmetries

Abstract Estimating expectation values is a key subroutine in quantum algorithms. Near-term implementations face two major challenges: a limited number of samples required to learn a large collection of observables, and the accumulation of errors in devices without quantum error correction. To address these challenges simultaneously, we develop a quantum error-mitigation strategy called symmetry-adjusted classical shadows , by adjusting classical-shadow tomography according to how symmetries are corrupted by device errors. As a concrete example, we highlight global U(1) symmetry, which manifests in fermions as particle number and in spins as total magnetization, and illustrate their group-theoretic unification with respective classical-shadow protocols. We establish rigorous sampling bounds under readout errors obeying minimal assumptions, and perform numerical experiments with a more comprehensive model of gate-level errors derived from existing quantum processors. Our results reveal symmetry-adjusted classical shadows as a low-cost strategy to mitigate errors from noisy quantum experiments in the ubiquitous presence of symmetry.

Zhao, Andrew (ORCID:0000000202990277)↗

Field expedient stool collection methods for gut microbiome analysis in deployed military environments

ABSTRACT Field expedient devices and protocols for the collection, storage, and shipment of stool samples in deployed settings are needed for the advancement of microbiome research in military health. Relevant assessments include the evaluation of microbiome signatures associated with susceptibility to travelers’ diarrhea and recovery of gut function following infection. However, inherent biases in microbial measurements due to preservatives and sampling methods are unclear and should be assessed for an accurate evaluation of the microbiome. We performed shotgun metagenomic sequencing and compared the microbiome composition in paired fecal samples collected using Flinters Technology Associates (FTA) cards and OMNIgene (OG) Gut tubes, prior to and during international travel, from 49 adult participants, 39 of whom remained asymptomatic and 10 experienced travelers’ diarrhea. Higher concentrations of nucleic acid and sequencing libraries were observed in OG samples. A majority of genera (82.9%) were detected with both methods, and detections of genera limited to one collection method were not highly prevalent across samples and were present in extremely low relative abundances (<0.01%). Differences in beta diversity were largely explained by inter-individuality of microbiome composition, followed by the effect of collection method and timepoint-disease states. Differential abundance analysis indicated that Corynebacterium and Blautia were consistently higher in abundance across all groups with FTA and OG collection, respectively. The observed differences in microbiome composition between methods suggest the need for consistent and standardized protocols within a study. Overall, the data presented here could help guide the future design of fecal microbiome study protocols in field and military deployment settings. IMPORTANCE The assessment of field-deployable methods for fecal sample collection and storage is required to reliably capture samples collected in remote and austere locations. This study describes a comparative metagenomics analysis between samples collected by two different commercially available methods in a military-deployed setting. The results presented here are foundational for the future design of fecal microbiome study protocols in an operational context.

field study↗