Search NASA⌕ Search

SEARCH · Search NASA

Results for “Software testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Wholesale Electricity Analysis via Simulation & Learning Experiments (WEASLE): Platform Development and Pilot Competition

This document reports the development of the Wholesale Electricity Analysis via Simulation and Learning Experiments (WEASLE) platform and the pilot competition that was conducted to test the platform. Due to the increasing reliance on variable renewable energy resources for bulk power, the pilot competition, called the Energy Storage Participation Algorithm Competition (ESPA-Comp), was used to test the effect of various market designs on storage utilization and market efficiency. Basic details of the platform are provided, including an overview of the market clearing engine, the battery dispatch and degradation models, electric grid topology and resource mix, and software architecture. Two market designs were tested: a two-settlement market analogous to typical ISO design today, and a multi-settlement market that allows additional forward-trading periods during the real-time market. Results from the pilot competition show that the storage bidding problem is nontrivial and is well suited for future challenges. We find that: 1) all four teams utilized different approaches to the bidding problem, 2) different methodological approaches led to substantially different offer behaviors, 3) resource profits are clustered by team and methodological approach, 4) simulated offers reduced market surplus by about 0.5%, 5) substantially different prices between two-settlement and multi-settlement markets albeit minimal difference in overall market surplus.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SU-E-T-33: An EPID-Based Method for Testing Absolute Leaf Position for MLC Without Backup Jaws

Purpose: Methods in common use for MLC leaf position QA are limited to measurements relative to an arbitrary reference position. The authors previously presented an EPID-based method for efficiently testing accuracy of leaf position relative to the mechanical isocenter for MLC with backup jaws. The purpose of this work is to extend that method to the general case of MLC without backup jaws. Methods: A pair of collimator walkout images is used to determine the location of the mechanical isocenter relative to the center of one field using a parameter called X-offset. The method allows for shift of the imager panel to cover subsets of MLC leaves within the limited field of view of the imager. For a shifted panel position, an image of three beam strips defined by a subset of MLC leaves allows determination of the position of each leaf relative to the isocenter. The location of the isocenter is determined by applying X-offset to an image of a single rectangular field obtained at that panel position. The method can also be used to test backup jaws instead of MLC leaves. A software tool was developed to efficiently analyze the images. Results: The software tool reports leaf position and deviation from nominal position, and provides visual displays to facilitate rapid qualitative interpretation. Test results using this method agree well with results using the previous method requiring backup jaws. Test results have been successfully used to recalibrate one model MLC (Elekta MLCi2™). Work in progress includes extension of the software tool to other MLC models, and quantification of reproducibility of the measurements. Conclusion: This work successfully demonstrates a method to efficiently and accurately measure MLC leaf position, or backup jaw position, relative to the mechanical isocenter of the collimator.

60 APPLIED LIFE SCIENCES↗

hypredrive: high-level interface for solving linear systems with hypre

This software introduces a high-level interface designed to simplify solving linear systems using hypre, a renowned library for such computational challenges. It is crafted to be accessible and user-friendly, making the powerful capabilities of hypre available to a broader audience without requiring in-depth technical knowledge. The interface is characterized by its use of YAML for input, a format celebrated for its structured yet straightforward readability. This choice ensures that users can easily configure the software to meet their specific needs. Additionally, the software boasts an intuitive API that encapsulates hypre's functionalities, making it easier for users to interact with the process of solving linear systems. It is particularly beneficial for prototyping, offering a quick and efficient means to test various solver and preconditioner configurations. Furthermore, the software allows for the creation of an offline testing framework in which predefined linear systems are read from files and benchmarked with user-defined solution strategies. This makes it an invaluable tool for developers and researchers exploring and validating their computational models. Overall, the software serves as a bridge, bringing the advanced computational capabilities of hypre closer to users who may need more specialized technical expertise, thereby facilitating innovation and exploration in the field of numerical linear algebra.

Paludetto Magri, Victor↗

Advancing Reactive Tracer Methods for Measurement of Thermal Evolution in Geothermal Reservoirs (Final Report)

The injection of cold fluids into engineered geothermal system (EGS) and conventional geothermal reservoirs may be done to help extract heat from the subsurface or to maintain pressures within the reservoir (e.g., Rose et al., 2001). As these injected fluids move along fractures, they acquire heat from the rock matrix and remove it from the reservoir as they are extracted to the surface. A consequence of such injection is the migration of a cold-fluid front through the reservoir (Figure 1) that could eventually reach the production well and result in the lowering of the temperature of the produced fluids (thermal breakthrough). Efficient operation of an EGS as well as conventional geothermal systems involving cold-fluid injection requires accurate and timely information about thermal depletion of the reservoir in response to operation. In particular, accurate predictions of the time to thermal breakthrough and subsequent rate of thermal drawdown are necessary for reservoir management, design of fracture stimulation and well drilling programs, and forecasting of economic return. A potential method for estimating migration of a cold front between an injection well and a production well is through application of reactive tracer tests, using chemical whose rate of degradation is dependent on the reservoir temperature between the two wells (e.g., Robinson 1985). With repeated tests, the rate of migration of the thermal front can be determined, and the time to thermal breakthrough calculated. While the basic theory behind the concept of thermal tracers has been understood for some time, effective application of the method has yet to be demonstrated. This report describes results of a study that used several methods to investigate application of reactive tracers to monitoring the thermal evolution of a geothermal reservoir. These methods included (1) mathematical investigation of the sensitivity of known and hypothetical reactive tracers, (2) laboratory testing of novel tracers that would improve method sensitivity, (3) development of a software tool for design and interpretation of reactive tracer tests and (4) field testing of the reactive tracer temperature monitoring concept.

15 GEOTHERMAL ENERGY↗

TU-C-BRE-02: A Novel, Highly Efficient and Automated Quality Assurance Tool for Modern Linear Accelerators

Purpose: Quality assurance (QA) of complex linear accelerators is critical and highly time consuming. Varian’s Machine Performance Check (MPC) uses IsoCal phantom to test geometric and dosimetric aspects of the TrueBeam systems in <5min. In this study we independently tested the accuracy and robustness of the MPC tools. Methods: MPC is automated for simultaneous image-acquisition, using kV-and-MV onboard-imagers (EPIDs), while delivering kV-and-MV beams in a set routine of varying gantry, collimator and couch angles. MPC software-tools analyze the images to test: i) beam-output and uniformity, ii) positional accuracy of isocenter, EPIDs, collimating jaws (CJs), MLC leaves and couch and iii) rotational accuracy of gantry, collimator and couch. 6MV-beam dose-output and uniformity were tested using ionization-chamber (IC) and ICarray. Winston-Lutz-Tests (WLT) were performed to measure isocenter-offsets caused by gantry, collimator and couch rotations. Positional accuracy of EPIDs was evaluated using radio-opaque markers of the IsoCal phantom. Furthermore, to test the robustness of the MPC tools we purposefully miscalibrated a non-clinical TrueBeam by introducing errors in beam-output, energy, symmetry, gantry angle, couch translations, CJs and MLC leaves positions. Results: 6MV-output and uniformity were within ±0.6% for most measurements with a maximum deviation of ±1.0%. Average isocenter-offset caused by gantry and collimator rotations was 0.316±0.011mm agreeing with IsoLock (0.274mm) and WLT (0.41mm). Average rotation-induced couch-shift from MPC was 0.378±0.032mm agreeing with WLT (0.35mm). MV-and-kV imager-offsets measured by MPC were within ±0.15mm. MPC predicted all machine miscalibrations within acceptable clinical tolerance. MPC detected the output miscalibrations within ±0.61% while the MLC and couch positions were within ±0.06mm and ±0.14mm, respectively. Gantry angle miscalibrations were detected within ±0.1°. Conclusions: MPC is a useful tool for QA of TrueBeam systems and its automation makes it highly efficient for testing both geometric and dosimetric aspects of the machine. This is very important for hypo-fractionated SBRT treatments. Received support from Varian Medical Systems, Palo Alto, CA 94304-1038.

07 ISOTOPE AND RADIATION SOURCES↗

OSIRIS Validation and Verification Report

The On-Site Inspection RadioIsotopic Spectroscopy (OSIRIS) system is a gamma-ray spectroscopy instrument for on-site inspections conducted under the Comprehensive Nuclear-Test-Ban Treaty (CTBT). The OSIRIS software filters spectral analysis data, revealing information to users on only 17 CTBT-relevant fission-product isotopes. In this report, we review the CTBT requirements for on-site inspection radionuclide identifiers, plus additional requirements imposed by the design team. Then a series of validation tests conducted during OSIRIS development are described. The validation tests were designed to gauge if the nascent OSIRIS system met those requirements. We conclude with a set of recommended verification tests to ensure that newly-manufactured OSIRIS systems also will meet the requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Report for Development of a Census Array and Evaluation of the Array to Detect Biothreat Agents and Environmental Samples for DHS

The objective of this project is to provide DHS a comprehensive evaluation of the current genomic technologies including genotyping, Taqman PCR, multiple locus variable tandem repeat analysis (MLVA), microarray and high-throughput DNA sequencing in the analysis of biothreat agents from complex environmental samples. This report focuses on the design, testing and results of samples on the Census Array. We designed a Census/Detection Array to detect all sequenced viruses (including phage), bacteria (eubacteria), and plasmids. Family-specific probes were selected for all sequenced viral and bacterial complete genomes, segments, and plasmids. Probes were designed to tolerate some sequence variation to enable detection of divergent species with homology to sequenced organisms, and to be unique relative to the human genome. A combination of 'detection' probes with high levels of conservation within a family plus 'census' probes targeting strain/isolate specific regions enabled detection and taxonomic classification from the level of family down to the strain. The array has wider coverage of bacterial and viral targets based on more recent sequence data and more probes per target than other microbial detection/discovery arrays in the literature. We tested the array with purified bacterial and viral DNA/RNA samples, artificial mixes of known bacterial/viral samples, spiked DNA against complex background including BW aerosol samples and soil samples, and environmental samples to evaluate the array's sensitivity and forensic capability. The data were analyzed using our novel maximum likelihood software. For most of the organisms tested, we have achieved at least species level discrimination.

59 BASIC BIOLOGICAL SCIENCES↗

Continuous Integration, In-Code Documentation, and Automation for Nuclear Quality Assurance Conformance

The Multiphysics Object Oriented Simulation Environment (MOOSE) is an open-source, finite element framework for solving highly coupled sets of nonlinear equations. The development of the framework and applications occurs concurrently using an agile, continuous-integration software package. Included in the framework is an in-code, extensible documentation system. Using these two tools in union with the repository management tools GitHub and GitLab, a software quality plan was created and followed such that MOOSE and a MOOSE-based application (BISON) have been shown to meet the American Society of Mechanical Engineers’ Nuclear Quality Assurance-1 standard. The approach relies heavily on automation for both testing and documentation. The resulting effort demonstrates that a rigorous software quality plan may be implemented that incurs a minimal impact on day-to-day development of the software, satisfying the stringent guidelines necessary to operate the software in a safety function within a nuclear facility.

97 MATHEMATICS AND COMPUTING↗

RELAP5-3D Developer Guidelines and Programming Practices

Our ultimate goal is to create and maintain RELAP5-3D as the best software tool available to analyze nuclear power plants. This begins with writing excellent programming and requires thorough testing. This document covers development of RELAP5-3D software, the behavior of the RELAP5-3D program that must be maintained, and code testing.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Performance Assessment of a New Gamma Spectroscopy Toolkit: Peak Doctor and the Spectral Nondestructive Assay Platform (SNAP) - 17397

High resolution gamma spectroscopy (HRGS) is a widely used technique for non-destructive characterization of nuclear materials, and assay of radioactive waste. The ability to accurately evaluate raw spectral data is an important step in producing high-quality results. A spectral analysis application known as Peak Doctor has been developed under a Cooperative Research and Development Agreement (CRADA) between LANL and Pajarito Scientific Corporation (PSC). The software has undergone several years of testing and validation by the Radioactive Waste Characterization Team of the LANL Waste Management Services Group (WM-SVS). PeakDoctor is designed to work with the Spectral Nondestructive Assay Platform (SNAP{sup TM}) to provide a complete HRGS analysis engine. SNAP{sup TM} performs model specific corrections for attenuation and geometry. These applications are the major components of a new toolkit designed primarily for portable far-field non-destructive assay. Peak Doctor performs a very accurate peak fit analysis with the goal of improving upon the capabilities of existing commercially available routines. It is designed to be user-configurable and can be customized to any given type of detector and any given type of spectrum. Peak Doctor was developed to resolve many of the inherent complexities in gamma ray spectra including overlapping peaks, complex multiplet regions, large step peaks, backscatter regions and Compton edges. Unlike most spectral analysis platforms, Peak Doctor does not rely on the energy calibration and detector resolution parameters that are saved by the operator in the spectrum file. Instead, key parameters are pre-defined for individual detectors. The software fits a continuum using a series of splines between a series of junctions or 'knots'. Fitting techniques are used to join the splines together to create a near-continuous multi-element curve. Optimizing the location of the knots is one of Peak Doctor's most powerful features. The knots are initially configured using a pre-defined list and are removed or added automatically during the fitting process. Knots are also created when new features are identified such as Step Peaks and Compton Edges. The user can also manually specify knots in order to improve the continuum fit. The initial fit is improved on by removing any outlier regions (which are converted to peaks) and the continuum fitting process is repeated. At this stage, an experienced user can work interactively with the fit by manually converting peak regions to continuum or vice versa. The final step is to fit a series of peaks above the continuum based on detector parameters. Single and multiplet peaks are then processed by either the tailing (piecewise) or non-tailing (Gaussian) Levenberg Marquardt non-linear peak fitting routine depending on the user defined selection. Only a rough knowledge of the detector characteristics (energy calibration and resolution) is required for the fitting process to proceed with good accuracy. Any peaks that are missed can be manually added by the user and will also be fitted. Discontinuities in the peak / continuum fit can be rapidly identified by reviewing the 'residuals scale' plot. For waste streams that are well characterized, it is often the case that routinely encountered spectra will have similar peaks and continuum features. For these cases a handy 'One Step' method is available that proceeds in an automated fashion without user interaction. Peak Doctor has been configured with a set of default spectrum types including plutonium / transuranic waste (including Weapons Grade Pu, Heat Source Pu, Am-241, Am-243 and Np-237), depleted or enriched uranium, nuclear power plant / intermediate level waste (with fission and activation products such as Cs-137 and Co-60) as well as Naturally Occurring Radioactive Materials (NORM). The user can easily add new spectrum types for specific waste streams or other types of radiological / special nuclear materials. The output from PeakDoctor (including net peak area, centroid energy and a list of minimum detectable activity levels at pre-defined regions) is used by SNAP{sup TM} to complete the data analysis process. Isotope activities are calculated using configurable template-driven geometry and attenuation correction methods. The software accounts for matrix and container wall effects, collimator / angular corrections, detector efficiency (based on calibration curves) and stand-off distance. SNAP{sup TM} uses published algorithms incorporating a series of decision points during its operation to allow the analyst to provide logical input to guide the software during the analysis of each unique spectrum. The Peak Doctor / SNAP{sup TM} toolkit has been extensively tested and validated under a variety of conditions using 'benchmark' reference spectra. Test scenarios reported include HPGe-based measurements of well characterized uranium and plutonium standards and radioactive sources with a variety of different geometries and matrix materials including surrogate drums and boxes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-F-T-218: Validation of An In-Vivo Proton Range Verification Method for Reducing the Risk of Permanent Alopecia in the Treatment of Pediatric Medulloblastoma

Purpose: The clinical commissioning of a workflow for pre-treatment range verification/adjustment for the head treatment of pediatric medulloblastoma patients, including dose monitoring during treatment. Methods: An array of Si-diodes (DIODES Incorporated) is placed on the patient skin on the opposite side to the beam entrance. A “scout” SOBP beam, with a longer beam range to cover the diodes in its plateau, is delivered; the measured signal is analyzed and the extracted water equivalent path lengths (WEPL) are compared to the expected values, revealing if a range correction is needed. Diodes stay in place during treatment to measure dose. The workflow was tested in solid water and head phantoms and validated against independent WEPL measurements. Both measured WEPL and skin doses were compared to computed values from the TPS (XiO); a Markus chamber was used for reference dose measurements. Results: The WEPL accuracy of the method was verified by comparing it with the dose extinction method. It resulted, for both solid water and head phantom, in the sub-millimeter range, with a deviation less than 1% to the value extracted from the TPS. The accuracy of dose measurements in the fall-off part of the dose profile was validated against the Markus chamber. The entire range verification workflow was successfully tested for the mock-treatment of head phantom with the standard delivery of 90 cGy per field per fraction. The WEPL measurement revealed no need for range correction. The dose measurements agreed to better than 4% with the prescription dose. The robustness of the method and workflow, including detector array, hardware set and software functions, was successfully stress-tested with multiple repetitions. Conclusion: The performance of the in-vivo range verification system and related workflow meet the clinical requirements in terms of the needed WEPL accuracy for pretreatment range verification with acceptable dose to the patient.

60 APPLIED LIFE SCIENCES↗

High Accuracy U-235 Enrichment Verification Station for Low Enriched Uranium Alloys

The Y-12 National Security Complex is playing a role in the U.S. High Performance Research Reactor (USHPRR) Conversion program sponsored by the U.S. National Nuclear Security Administration&#x27;s Office of Global Threat Reduction. The USHPRR program has a goal of converting remaining U.S. reactors that continue to use highly enriched uranium (HEU) fuel to low enriched uranium (LEU) fuel. The USHPRR program is currently developing a LEU Uranium-Molybdenum (U-Mo) monolithic fuel for use in the U.S. high performance research reactors.Y-12 is supporting both the fuel development and fuel fabrication efforts by fabricating low enriched U-Mo foils from its own source material for irradiation experiments and for optimizing the fabrication process in support of scaling up the process to a commercial production scale. Once the new fuel is qualified, Y-12 will produce and ship U-Mo coupons with verified 19.75% +0.2% - 0.3% U-235 enrichment to be fabricated into fuel elements for the USHPRRs. Considering this small enrichment tolerance and the transition into HEU being set strictly at 20% U-235, a characterization system with a measurement uncertainty of less than or equal to 0.1% in enrichment is desired to support customer requirements and minimize production costs. Typical uncertainty for most available characterization systems today is approximately 1-5%; therefore, a specialized system must be developed which results in a reduced measurement uncertainty. A potential system using a High-Purity Germanium (HPGe) detector has been procured, and tests have been conducted to verify its capabilities with regards to the requirements. Using four U-Mo enrichment standards fabricated with complete isotopic and chemical characterization, infinite thickness and peak-ratio enrichment measurement methods have been considered for use. As a result of inhomogeneity within the U-Mo samples, FRAM, an isotopic analysis software, has been selected for initial testing. A systematic approach towards observing effects on FRAM&#x27;s enrichment analysis has been conducted with regards to count and dead time.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fortran Compiler Test Suite v0.1.0

There is no currently available, open-source, easily adapted test suite for checking a compiler's conformance to the Fortran Standard. The main innovation of this software is in the framework to make the test suite apply to a new compiler. Making it open-source will enable community contributions of the test cases. Single organization construction of a comprehensive test suite is something that would be financially infeasible.

Richardson, Bradley↗

Cybersecurity Certification Requirements for Distributed Energy Resources: A Survey of SunSpec Alliance Standards

This survey paper explores the cybersecurity certification requirements defined by the SunSpec Alliance for Distributed Energy Resource (DER) devices, focusing on aspects such as software updates, device communications, authentication mechanisms, device security, logging, and test procedures. The SunSpec cybersecurity standards mandate support for remote and automated software updates, secure communication protocols, stringent authentication practices, and robust logging mechanisms to ensure operational integrity. Furthermore, the paper discusses the implementation of the SAE J3072 standard using the IEEE 2030.5 protocol, emphasizing the secure interactions between electric vehicle supply equipment (EVSE) and plug-in electric vehicles (PEVs) for functionalities like vehicle-to-grid (V2G) capabilities. This research also examines the SunSpec Modbus standard, which enhances the interoperability among DER system components, facilitating compliance with grid interconnection standards. This paper also analyzes the existing SunSpec Device Information Models, which standardize data exchange formats for DER systems across communication interfaces. Finally, this paper concludes with a detailed discussion of the energy storage cybersecurity specification and the blockchain cybersecurity requirements as proposed by SunSpec Alliance.

Tsikteris, Sean (ORCID:0009000524202250)↗

NII Simulator 1.0

The software listed here is a simulator for SAIC P7500 VACIS non intrusive inspection system. The simulator provides messages similar to those provided by this piece of equipment.To facilitate testing of the Second Line of Defense systems and similar software products from commercial software vendors, this software simulation application has been developed to simulate the P7500 that the Second Line of Defense communications software system must interface with. The primary use of this simulator is for testing of both Sandia developed and DOE contractor developed software.

Jorgensen, Craig↗

Uncertainty Analysis and Software Verification

Uncertainty analyses are an important part of calibrations and testing. They allow researchers insight on how to reduce and mitigate errors in testing. Each device used in testing introduces error in a system, as well as other sources such as environmental conditions, electronics, analog to digital, and random errors. Each source is carefully examined to identify how much error it introduces to a system. These sources are then combined using various methods of uncertainty calculations. To verify and validate software, a manual calculation is required to ensure the software is performing as intended. Using Excel to verify the calculations, we can identify discrepancies within the software. The root of the sum of the squares uncertainty (RSS) is used to find the combined uncertainty of a device at one and two standard deviations of the mean. Calibrations on accelerometers are performed using a vibration system along with a back-toback reference accelerometer. The vibration system takes a reference point at 100Hz frequency at 10g amplitude. The sensitivities are collected at each dialed in frequency. The sensitivity of the device represents the electrical output of the UUT (mV, pC, etc.) per unit of acceleration (g). The full history of sensitivities of selected accelerometers are used to find the averaged, standard deviation, and uncertainty of the device at each frequency tested. The uncertainty calculations from excel and the software are then compared.

97 MATHEMATICS AND COMPUTING↗

RAPIDS2: A SciDAC Institute for Computer Science, Data, and Artificial Intelligence (University of Delaware)

This report summarizes the activities, technical accomplishments, and outcomes of the RAPIDS2 Institute project at the University of Delaware (UD). The RAPIDS2 Institute was a large multi-institution project with the objective of assisting SciDAC and Office of Science application teams in the use of DOE supercomputing resources to achieve scientific breakthroughs. The UD team contributed to this effort through work on formal software verification. This thrust aims to reduce software developer time and effort, especially regarding debugging and testing, and to increase confidence in the correctness of the results computed by the software.

97 MATHEMATICS AND COMPUTING↗

SU-E-T-80: Comparison of Fluence-Based RapidArc QAs Using EPID and MapCHECK 2

Purpose: To compare the Varian aS-1000 EPID imager to the isocentrically mounted MapCHECK 2 diode array for RapidArc QAs as a function of photon beam energy. Methods: A Varian TrueBeam STx with an aS-1000 digital imaging panel was used to acquire RapidArc QA images for 13 patient plans; each plan QA was performed at 6, 8, 10 and 15MV energies. The Portal Dose Image Prediction algorithm in the Varian Eclipse treatment planning system (TPS) was used to create the comparison image for the EPID acquisition. A Sun Nuclear MapCHECK 2 diode array on an isocentric mounting fixture with 5 cm water-equivalent buildup was also used for the RapidArc QAs. A composite dose plane was taken from the Eclipse TPS for comparison to the MapCHECK 2 measurements. A gamma test was implemented in the Sun Nuclear Patient software with 10% threshold and absolute comparison for both QA methods. The two-tailed paired t-test was employed to analyze the statistical significance between two methods at the 95% confidence level. Results: The average gamma passing rates were greater than 95% at 3%/3mm using both methods for all four energies. The average passing rates were within 2.5% and 1.1% of each other when analyzed at 2%/2mm and 3%/3mm conditions, respectively. The EPID passing rates were somewhat better than the MapCHECK 2 when analyzed at 1%/1mm condition; this difference decreased with increasing energy (9.1% at 6MV to 2.7% at 15MV). The differences were not statistically significant for all criteria and energies (p-value ã 0.05). Conclusion: EPID-based RapidArc QA results are comparable to MapCHECK 2 when using 3%/3mm criteria at all four energies. EPID-based QA shows potential for being the superior device under strict gamma criteria.

60 APPLIED LIFE SCIENCES↗