Search NASA⌕ Search

SEARCH · Search NASA

Results for “Source Term Characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Characterization of a Pixelated Cadmium Telluride Detector System Using a Polychromatic X-Ray Source and Gold Nanoparticle-Loaded Phantoms for Benchtop X-Ray Fluorescence Imaging

In this paper, the imaging dose and scan time have been considered as the two major constraints for routine benchtop x-ray fluorescence computed tomography (XFCT) imaging. One way to address this issue is to acquire x-ray fluorescence (XRF) signals in parallel through a 2D array of single-crystal detectors or a pixelated detector along with the cone-beam x-ray source. To identify a detector system suitable for this purpose, a commercially available, fully spectroscopic cadmium telluride (CdTe) pixelated detector, HEXITEC (High-Energy X-ray Imaging Technology), was tested under the experimental conditions optimized for benchtop XFCT imaging of gold nanoparticles (GNPs). Specifically, two different parallel-hole stainless steel collimators were fabricated and coupled with the detector for seamless integration into our existing benchtop cone-beam XFCT system. After the detector deployment, this benchtop XFCT system was used to detect XRF photons from GNP-loaded phantoms. A pixel-merging algorithm was introduced to enhance the sensitivity of XRF photon detection thereby minimizing the scan time. The effect of pixel-level charge sharing correction algorithms was investigated within the context of benchtop XFCT imaging. The detector energy resolution, in terms of the full width at half maximum (FWHM) values at different gold K-shell XRF energies, was also determined. Of the two charge sharing correction algorithms examined, the charge sharing addition gave better sensitivity than the charge sharing discrimination (csd). On the other hand, under the current experimental conditions, the energy resolution of the HEXITEC detector was the best with the csd and estimated to be 1.56 keV FWHM at 66-69 keV photon energy. Overall, despite some degradation of the detector energy resolution (compared with typical single crystal CdTe detectors), the HEXITEC detector enabled parallel data acquisition under the experimental conditions typical of benchtop XFCT imaging and operated well within our benchtop XFCT setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SALSA3D: A Tomographic Model of Compressional Wave Slowness in the Earth’s Mantle for Improved Travel-Time Prediction and Travel-Time Prediction Uncertainty

The task of monitoring the Earth for nuclear explosions relies heavily on seismic data to detect, locate, and characterize suspected nuclear tests. In this study, motivated by the need to locate suspected explosions as accurately and precisely as possible, we developed a tomographic model of the compressional wave slowness in the Earth’s mantle with primary focus on the accuracy and precision of travel-time predictions for P and Pn ray paths through the model. Path-dependent travel-time prediction uncertainties are obtained by computing the full 3D model covariance matrix and then integrating slowness variance and covariance along ray paths from source to receiver. Path-dependent travel-time prediction uncertainties reflect the amount of seismic data that was used in tomography with very low values for paths represented by abundant data in the tomographic data set and very high values for paths through portions of the model that were poorly sampled by the tomography data set. The pattern of travel-time prediction uncertainty is a direct result of the off-diagonal terms of the model covariance matrix and underscores the importance of incorporating the full model covariance matrix in the determination of travel-time prediction uncertainty. In addition, the computed pattern of uncertainty differs significantly from that of 1D distance-dependent travel-time uncertainties computed using traditional methods, which are only appropriate for use with travel times computed through 1D velocity models.

58 GEOSCIENCES↗

Transportation Energy Data Book: Edition 38

The Transportation Energy Data Book: Edition 38 is a statistical compendium prepared and published by Oak Ridge National Laboratory (ORNL) under contract with the U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy, Vehicle Technologies Office. Designed for use as a desk-top reference, the Data Book represents an assembly and display of statistics and information that characterize transportation activity, and presents data on other factors that influence transportation energy use. The purpose of this document is to present relevant statistical data in the form of tables and graphs. The latest edition of the Data Book is available via the Internet. This edition of the Data Book has 13 chapters which focus on various aspects of the transportation industry. Chapter 1 - focuses on petroleum; Chapter 2 - energy; Chapter 3 - highway vehicles; Chapter 4 - light vehicles; Chapter 5 - heavy vehicles; Chapter 6 - alternative fuel vehicles; Chapter 7 - transit and shared mobility; Chapter 8 - fleet vehicles; Chapter 9 - household vehicles; Chapter 10 - nonhighway modes; Chapter 11 - transportation and the economy; Chapter 12 - greenhouse gas emissions; and Chapter 13 - criteria pollutant emissions. The sources used represent the latest available data. There are also three appendices which include detailed source information for some tables, measures of conversion, and energy tables and figures with electricity generation and distribution taken into account. A glossary of terms is also included for the reader’s convenience.

02 PETROLEUM↗

Performance of an RPM based on Gd-lined plastic scintillator for neutron and gamma detection [ANIMMA--2015-IO-372]

A Radiation Portal Monitor (RPM) was developed by the Istituto Nazionale di Fisica Nucleare (INFN) and Ansaldo Nucleare (ANN) within the FP7 SCINTILLA European project. The system was designed to detect both gamma and neutron radiation with a single technology. It is conceived to monitor vehicle and cargo containers in transits across borders or ports, to find radioactive elements and to avoid illegal trafficking of strategic nuclear materials. The system is based on a {sup 3}He-free neutron detection technology using plastic scintillators coupled to Gadolinium to detect and discriminate gamma from neutron signals. During the 3 years of the SCINTILLA project the construction and test of the first two prototypes drove the definition of the final layout of a full RPM system consisting of two twin pillars as a portal for vehicle and cargo container scan. A custom System Control Software (SCS) manages the electronics of the RPM, the ancillary devices and the data analysis. The combination of the detector layout and of the software functionalities enables both to distinguish neutrons and gammas and to identify the energy range of a detected gamma source. The system was initially characterized via static tests with gamma and neutron sources in the INFN laboratory. These measurements were used to calibrate the detector, evaluate the response of the single pillars as well as of the full system, and optimize the RPM configuration and discrimination algorithm. During this phase, specific tests were performed to study the stability over time of the system, monitoring the measured the neutron and gamma count rates over periods of several weeks. The results allow us to demonstrate the reliability and robustness of the RPM. In a second time the RPM performance was studied via dynamic tests performed during the SCINTILLA test and benchmark campaigns. These measurements took place in the JRC ITRAP+10 facility at Ispra (Varese-Italy). The laboratory is equipped with an experimental set-up for dynamic tests of multiple systems according to international standards. The performed measurements utilized radioactive sources with activities selected according to ANSI and IEC standards to test the detector alarm performances in terms of gamma and neutron response, sensitivity to high gamma fields, sensitivity to moderated neutron sources as well as false alarm rates (FAR). In addition, the RPM was tested in challenging configurations exceeding the requirements set by international standards to determine the real limits of the system. The results obtained during these campaigns demonstrated that the system detection efficiency is not only compliant to international standards for its category, but often exceeds them, demonstrating the validity of the chosen technology and of the implemented layout. The positive performance also showed the effectiveness of the SCS and of its functionalities. To further demonstrate the system capabilities, a test in a real-life environment of the RPM is planned to happen in a near future by installing the detectors in a seaport. In this presentation I will give an overview of the RPM characteristics, of its performances as determined in the test campaign mentioned above and of future plans, to demonstrate how this technology can be an effective choice for the realization of {sup 3}He-free RPM detectors. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Feasibility of Using Radar for Characterizing and Tracking Plumes

With the enhanced capabilities of NEXRAD radars has come an increased body of research focused on non-weather artifacts in the radar signal. Radar data has been collected and evaluated for a range of plume-generating events. Events such as wildfires, measuring and tracking ash from volcanic eruptions, and tracking plumes from events such as the SpaceX rocket explosion in 2016 have been investigated to determine the useful measurements available in radar data. For decision makers interested in radar use in nuclear forensics or during an emergency response, the usefulness of radar for attempting to provide some answers early in an event is clear. Currently emplaced operational radars provide high spatial and temporal resolution data within minutes of an event. This is not to say radar observations would replace current methods used by decision makers; however, supplementing decision making with radar data can only enhance and better inform the decision process. This report builds on two previous reports submitted in November 2016 and May 2017. This feasibility study demonstrates that radar can be used to improve decision making in the early phases of a plume-generating event by decreasing uncertainty as well as improving source-term inputs in F&T models. Radar coverage exists today in capabilities such as NOAA’s NEXRAD weather surveillance radars and Terminal Doppler Weather Radars. Improvement could be realized quickly by (1) improving awareness of existing radar products and incorporating them into decision making and modeling efforts, (2) evaluating and improving radar coverage around key urban areas and critical infrastructure, and (3) improving radar algorithms to optimize for non-meteorological events such as plumes.

47 OTHER INSTRUMENTATION↗

Characterization of the Neutron Fields in the Lawrence Livermore National Laboratory (LLNL) Radiation Calibration Laboratory Low Scatter Calibration Facility

In June 2007, the Department of Energy (DOE) revised its rule on Occupational Radiation Protection, Part 10 CFR 835. A significant aspect of the revision was the adoption of the recommendations outlined in International Commission on Radiological Protection (ICRP) Report 60 (ICRP-60), including new radiation weighting factors for neutrons, updated internal dosimetric models, and dose terms consistent with the newer ICRP recommendations. ICRP-60 uses the quantities defined by the International Commission on Radiation Units and Measurements (ICRU) for personnel and area monitoring including the ambient dose equivalent H*(d). A Joint Task Group of ICRU and ICRP has developed various fluence-to-dose conversion coefficients which are published in ICRP-74 for both protection and operational quantities. In February 2008, Lawrence Livermore National Laboratory (LLNL) replaced its old pneumatic transport neutron irradiation system in the Radiation Calibration Laboratory (RCL) Low Scatter Calibration Facility (B255, Room 183A) with a Hopewell Designs irradiator model N40. The exposure tube for the Hopewell system is located close to, but not in exactly the same position as the exposure tube for the pneumatic system. Additionally, the sources for the Hopewell system are stored in Room 183A where, prior to the change, they were stored in a separate room (Room 183C). The new source configuration and revision of the 10 CFR 835 radiation weighting factors necessitate a re-evaluation of the neutron dose rates in B255 Room 183A. This report deals only with the changes in the operational quantities ambient dose equivalent and ambient dose rate equivalent for neutrons as a result of the implementation of the revised 10 CFR 835. In the report, the terms 'neutron dose' and 'neutron dose rate' will be used for convenience for ambient neutron dose equivalent and ambient neutron dose rate equivalent unless otherwise stated.

61 RADIATION PROTECTION AND DOSIMETRY↗

Viewing spin structures with soft x-ray microscopy

The spin of the electron and its associated magnetic moment marks the basic unit for magnetic properties of matter. Magnetism, in particular ferromagnetism and antiferromagnetism is described by a collective order of these spins, where the interaction between individual spins reflects a competition between exchange, anisotropy and dipolar energy terms. As a result the energetically favored ground state of a ferromagnetic system is a rather complex spin configuration, the magnetic domain structure. Magnetism is one of the eldest scientific phenomena, yet it is one of the most powerful and versatile utilized physical effects in modern technologies, such as in magnetic storage and sensor devices. To achieve highest storage density, the relevant length scales, such as the bit size in disk drives is now approaching the nanoscale and as such further developments have to deal with nanoscience phenomena. Advanced characterization tools are required to fully understand the underlying physical principles. Magnetic microscopes using polarized soft X-rays offer a close-up view into magnetism with unique features, these include elemental sensitivity due to X-ray magnetic dichroism effects as contrast mechanism, high spatial resolution provided by state-of-the-art X-ray optics and fast time resolution limited by the inherent time structure of current X-ray sources, which will be overcome with the introduction of ultrafast and high brilliant X-ray sources.

36 MATERIALS SCIENCE↗

Rapid Response Radiation Sensors for Homeland Security Applications

The National Security Technologies, LLC, Remote Sensing Laboratory is developing a rapid response radiation detection system for homeland security field applications. The intelligence-driven system is deployed only when non-radiological information about the target is verifiable. The survey area is often limited, so the detection range is small; in most cases covering a distance of 10 meters or less suffices. Definitive response is required in no more than 3 seconds and should minimize false negative alarms, but can err on the side of positive false alarms. The detection system is rapidly reconfigurable in terms of size, shape, and outer appearance; it is a plug-and-play system. Multiple radiation detection components (viz., two or more sodium iodide scintillators) are used to independently “over-determine” the existence of the threat object. Rapid response electronic dose rate meters are also included in the equipment suite. Carefully studied threat signatures are the basis of the decision making. The use of Rad-Detect predictive modeling provides information on the nature of the threat object. Rad-Detect provides accurate dose rate from heavily shielded large sources; for example those lost in Mexico were Category 1 radiation sources (~3,000 Ci of 60Co), the most dangerous of five categories defined by the International Atomic Energy Agency. Taken out of their shielding containers, Category 1 sources can kill anyone who is exposed to them at close range for a few minutes to an hour. Whenever possible sub-second data acquisition will be attempted, and, when deployed, the system will be characterized for false alarm rates. Although the radiation detection materials selected are fast (viz., faster scintillators), their speed is secondary to sensitivity, which is of primary importance. Results from these efforts will be discussed and demonstrated.

gamma detector, false alarm rate, sub-second data ↗

Fluidized Bed Gasification For Conversion of Biomass and Waste Materials to Renewable Hydrogen

This project was undertaken in order to study the potential for hydrogen production, at low cost, from mixtures of biomass and municipal solid waste (MSW). This approach allows for the production of hydrogen with a very low fossil carbon burden, while taking advantage of tipping fees (associated with MSW) to improved process economics. The team sourced three primary feedstocks (wood, MSW, and waste plastics) and characterized them comprehensively using established techniques with a long track record in the field of gasification. All three primary feedstocks were highly reactive and lost most of their mass during initial devolatilization. The production of tars, including heavy tars, was quite high, and was most problematic in the case of the MSW and Waste Plastics feedstocks. Little practical difference was identified between the MSW and Waste Plastics materials, and the addition of bed-forming materials (dolomite and brown alumina) to the feedstocks was found to reduce production of tars during devolatilization under thermogravimetric analysis and/or Fischer Assay conditions. A series of four tests in a lab-scale bubbling-fluidized-bed gasifier, at 50 psig of pressure and about 825 C, confirmed these findings. Pellet feedstocks, broken into fragments, were used for these tests, and pellets comprised of 50% MSW and 50% biomass were found to be the best option in terms of fossil carbon burden, economic potential, and gasification characteristics. Tests were then undertaken in a pilot-scale gasifier facility based on the GTI U-Gas fluidized-bed gasification technology. The feedstock handling train of the 20 TPD U-Gas pilot-scale gasifier located in Des Plaines, IL, was operated under simulated gasification conditions, and the 50/50 pellets were found to be very robust and unproblematic. An improved design for the forward end of the feedstock injection screw of the gasifier was developed and installed. The design approach was based on improved passive cooling of the front-most shroud at the end of the screw, since this approach was found in comprehensive modeling studies to be more than sufficient to accomplish the project objectives associated with this phase of the work, while also avoiding thermal gradients that could have caused heat-stress-induced damage to the refractory around the feedstock inlet if an active cooling approach had been applied. Careful technoeconomic analysis (TEA) of two possible 1000 TPD facilities was carried out. The TEA of conversion of MSW with corn stover in one case, and MSW with woody feedstock in the other case, showed that both had the potential to provide hydrogen at about $1/kg (minimum selling price, 2018 dollar basis). Of the two TEA cases, the one that was based on the conversion of wood in the southeastern USA was found to have slightly better economic potential. The other TEA case was based on a real location in Nebraska and called for corn stover feedstock conversion along with MSW. An underserved communities outreach program plan was developed in cooperation with personnel from the Nebraska Public Power District.

08 HYDROGEN↗

Resonance ultrasound prediction of residual stress within a hybrid layer for additively manufactured samples

Hybrid additive manufacturing (AM) involves secondary processes or energy sources to alter specified locations within the build volume. Each hybrid step can refine the grain size, increase dislocation density, or modify residual stresses. Typically, the changes in mechanical properties are not confined within a single layer but have a compounding effect on preceding layers. Existing methods of measuring AM residual stress are limited in terms of their sensitivity, or they are destructive measurements. We propose using resonant ultrasound spectroscopy (RUS) to measure the residual stress in hybrid-AM components noninvasively, based on changes to the resonances, compared to a stress-free component. In this paper, we use finite element models to simulate residual stress in hybrid-AM components and to examine the sensitivity of RUS measurements in terms of frequency shifts and mode shapes with respect to single hybrid layers. Then, the RUS results are used to predict stress for a layer at a known location with unknown stress. Here, the approach highlights the capabilities of RUS to address an AM characterization challenge.

36 MATERIALS SCIENCE↗

SECARB Permits for Seismic and Other Site Preparation Plan

The Southeast Regional Carbon Sequestration Partnership’s (SECARB’s) Anthropogenic Test is a demonstration of the deployment of CO 2 capture, transport, geologic storage and monitoring technologies. This project is one of the first and the largest fully integrated commercial prototype coal-fired carbon capture and storage projects in the USA. Drilled in January 2011, a deep characterization well provided geologic data confirming that the test site represented an attractive location for safe, long-term storage of CO 2 . Two Class V Experimental Injection Well underground injection control (UIC) permits were issued in November 2011 and subsequently the project’s injection wells were installed. A robust monitoring, verification and accounting (MVA) plan has been developed to monitor and track the CO 2 plume and the associated pressure field. The CO 2 MVA effort for the Anthropogenic Test CO 2 (Test) injection demonstration includes two wellbore seismic methods, specifically time-lapse Croswell seismic and vertical seismic profiles (VSP). Due to the unique challenges presented by this Test (injection depth of 9,500+ ft. into thin, stacked reservoir sands and limited injection volumes) surface seismic was eliminated as a Monitoring, Verification, and Accounting (MVA) tool. However, the newly drilled project wells provided ample casing diameters (prior to running tubing) to accommodate wellbore seismic receivers (wireline and tubing deployed) and a Croswell source.

54 ENVIRONMENTAL SCIENCES↗

The Measurement of MTFs in X-ray Microscopy Using Diffractograms

A novel method to characterize the optical performance of a high-resolution transmission x-ray microscope is presented. It makes use of test patterns that consist of random arrays of sub-resolution holes in a thin metal film, and so approximate to white-noise input signals for the microscope. The test patterns have been fabricated by electron-beam lithography at length scales appropriate for the resolution available in x-ray microscopy, so that diffractograms produced from the image data can be directly interpreted in terms of the contrast transfer function of the optical system. Results of this method are shown for both brightfield and differential phase contrast imaging.

07 ISOTOPE AND RADIATION SOURCES↗

Long-term stabilization of a heterodyne metrology interferometer down to a noise level of 20 pm over an hour

A heterodyne metrology interferometer was stabilized down to a noise level of 20 picometers (pm) as a root-mean-square (RMS) value integrated between 0.3 mHz and 1 Hz. This noise level was achieved by employing active and passive interferometer stabilization techniques. The heterodyne interferometer was built on a 50 mm square ultralow expansion glass plate in order to reduce an optical path length change caused by temperature variation. An optical configuration of the interferometer is a Mach-Zehnder interferometer with a design as symmetric as possible so that a detection signal can be insensitive to homogeneous thermal expansion of the glass plate. The heterodyne frequency is actively controlled in order to suppress residual noises caused by optical path length changes outside of the glass plate as well as phase fluctuations of the heterodyne frequency source. Our stabilization scheme is considered useful in achieving the 20 pm noise level without a stable heterodyne frequency source, as well as temperature stabilization around a whole apparatus. This interferometer can be used in precise metrology applications, such as characterization of deformation for satellite optical components against thermal exposure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of Time Window and Spectral Measurement Options on Empirical Green’s Function Analysis Using DAS Array and Seismic Stations

The recorded seismic waveform is a convolution of event source term, path term, and station term. Removing high-frequency attenuation due to path effect is a challenging problem. Empirical Green’s function (EGF) method uses nearly collocated small earthquakes to correct the path and station terms for larger events recorded at the same station. However, this method is subject to variability due to many factors. Here, we focus on three events that were well recorded by the seismic network and a rapid response distributed acoustic sensing (DAS) array. Using a suite of high-quality EGF events, we assess the influence of time window, spectral measurement options, and types of data on the spectral ratio and relative source time function (RSTF) results. Increased number of tapers (from 2 to 16) tends to increase the measured corner frequency and reduce the source complexity. Extended long time window (e.g., 30 s) tends to produce larger variability of corner frequency. The multitaper algorithm that simultaneously optimizes both target and EGF spectra produces the most stable corner-frequency measurements. The stacked spectral ratio and RSTF from the DAS array are more stable than two nearby seismic stations, and are comparable to stacked results from the seismic network, suggesting that DAS array has strong potential in source characterization.

58 GEOSCIENCES↗

Sensor Networks for Detecting Toxic Releases in Buildings

Sudden releases of a toxic agent indoors can cause immediate and long-term harm to occupants. In order to protect building occupants from such threats, it is necessary to have a robust air monitoring system that can detect, locate, and characterize accidental or deliberate toxic gas releases. However, developing such a system is complicated by several requirements, in particular the need to operate in real-time. This task is further complicated when monitoring sensors are prone to false positive and false negative readings. We report on work towards developing an indoor monitoring system that is robust even in the presence of poor quality sensor data. The algorithm, named BASSET, combines deterministic modeling and Bayesian statistics to join prior knowledge of the contaminant transport in the building with real-time sensor information. We evaluate BASSET across several data sets, which vary in sensor characteristics such as accuracy, response time, and trigger level. Our results suggest that optimal designs are not always intuitive. For example, a network comprised of slower but more accurate sensors may locate the contaminant source more quickly than a network with faster but less accurate sensors.

54 ENVIRONMENTAL SCIENCES↗

An integrated systems-based approach to mercury research and technology development

A 3-year strategic planning process was undertaken in Oak Ridge, Tennessee, to develop a research and technology development approach that can help guide mercury remediation in East Fork Poplar Creek (EFPC). Mercury remediation is a high priority for the US Department of Energy s (DOE s) Oak Ridge Office of Environmental Management because of large historical losses of mercury to the environment at the Y-12 National Security Complex (Y-12). Because of the extent of mercury losses and the complexities of mercury transport and fate in the stream environment, the success of conventional options for mercury remediation in the downstream sections of EFPC is uncertain. The overall Oak Ridge mercury remediation strategy focuses on mercury treatment actions at Y-12 in the short-term and research and technology development to evaluate longer-term solutions in the downstream environment. The technology development strategy is consistent with a phased, adaptive management paradigm and DOE s Technology Readiness Level guidelines. That is, early evaluation includes literature review, site characterization, and small-scale studies of a broad number of potential technologies. As more information is gathered, technologies that may have the most promise and potential remediation benefit will be chosen for more extensive and larger-scale pilot testing before being considered for remedial implementation. Field and laboratory research in EFPC is providing an improved level of understanding of mercury transport and fate processes in EFPC that will inform the development of site-specific remedial technologies. Technology development has centered on developing strategies that can mitigate the primary factors affecting mercury risks in the stream: (1) the amount of inorganic mercury available to the stream system, (2) the conversion of inorganic mercury to methylmercury, and (3) the bioaccumulation of methylmercury through the food web. Given the downstream complexities and interdependencies between sources and processes in EFPC, no one task or approach is likely to solve the mercury problem in the creek, thus highlighting the importance of using an integrated, systems-based approach to develop remedial solutions.

Peterson, Mark J↗

Peptidome analysis of human skim milk in term and preterm milk

Highlights: •A method was developed for preparation of peptide extracts from human milk. •Analysis of the extracts by LC–MS/MS resulted in the detection of 1000–3000 peptide-like features. •419 Peptides were identified by LC–MS/MS from 34 proteins. •Isotope dimethyl labeling analysis revealed 41 peptides differentially expressed. -- Abstract: The abundant proteins in human milk have been well characterized and are known to provide nutritional, protective, and developmental advantages to both term and preterm infants. Due to the difficulties associated with detection technology of the peptides, the expression of the peptides present in human milk is not known widely. In recent years, peptidome analysis has received increasing attention. In this report, the analysis of endogenous peptides in human milk was done by mass spectrometry. A method was also developed by our researchers, which can be used in the extraction of peptide from human milk. Analysis of the extracts by LC–MS/MS resulted in the detection of 1000–3000 Da peptide-like features. Out of these, 419 peptides were identified by MS/MS. The identified peptides were found to originate from 34 proteins, of which several have been reported. Analysis of the peptides’ cleavage sites showed that the peptides are cleaved with regulations. This may reflect the protease activity and distribution in human body, and also represent the biological state of the tissue and provide a fresh source for biomarker discovery. Isotope dimethyl labeling analysis was also used to test the effects of premature delivery on milk protein composition in this study. Differences in peptides expression between breast milk in term milk (38–41 weeks gestation) and preterm milk (28–32 weeks gestation) were investigated in this study. 41 Peptides in these two groups were found expressed differently. 23 Peptides were present at higher levels in preterm milk, and 18 were present at higher levels in term milk.

60 APPLIED LIFE SCIENCES↗

Detecting new very light bosons by Cherenkov telescopes

A generic prediction of several extensions of the Standard Model of elementary-particle interactions is the existence of axion-like particles (ALPs), namely very light spin-zero bosons characterized by a two-photon coupling. While elusive in laboratory experiments, ALPs can give rise to observable astrophysical effects for their relevant parameters in experimentally allowed ranges. We show that the unexpectedly low opacity of the Universe inferred by the Imaging Atmospheric Cherenkov Telescopes since 2006 from blazar observations above 100 GeV can be explained naturally within the De Angelis, Roncadelli and Mansutti--hereafter DARMA--scenario, namely in terms of photon-ALP oscillations occurring in extragalactic magnetic fields. We work out the implications of the DARMA scenario for the VHE gamma-ray spectra of blazars by contemplating all of them at once, so that the emitted GAMMA{sub em} and observed GAMMA{sub obs} spectral indices can be correlated. We demonstrate that by assuming the same nominal value GAMMA{sub em}approx =2.4 for all VHE blazars, the predicted observed spectral index GAMMA{sub obs}{sup DARMA} actually fits all observations. Moreover, GAMMA{sub obs}{sup DARMA} becomes independent of redshift for sufficiently far-away sources. Our prediction can be tested with the satellite-borne Fermi/LAT detector as well as with the ground-based IACTs H.E.S.S., MAGIC, CANGAROO III, VERITAS and the Extensive Air Shower arrays ARGO-YBJ and MILAGRO.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗