Search NASA⌕ Search

SEARCH · Search NASA

Results for “Temperature Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Spin Seebeck effect in insulating SrFeO 3–δ films

In SrFeO 3–δ , noncollinear antiferromagnetic spin textures have led to the observation of the topological Hall effect and may give rise to novel magnetic excitations. Here, we measured the spin Seebeck effect in epitaxial, oxygen reduced SrFeO 3–δ films, which are nonferromagnetic and insulating at low temperatures. Here, we detected a spin Seebeck signal below 300K and the signal is enhanced below approximate to 100K, near the ordering temperature of incommensurate antiferromagnetism found in bulk single crystals of SrFeO 3–δ . The spin Seebeck signal increases in magnitude and develops a nonlinear dependence on the magnetic field at lower temperatures. Control experiments were used to verify that the measured signal arises from a spin current and to rule out magnetic proximity effects. Our work shows a detectable spin Seebeck signal in nonferromagnetic insulator SrFeO 3–δ .

36 MATERIALS SCIENCE↗

Tailoring low energy electron absorption via surface nano-engineering of cesiated chromium films

Here, we demonstrate that improved low energy electron absorption is achieved by suppressing the crystallinity of chromium thin-films grown on W[110], which points to a promising route for achieving highly efficient thermionic energy converters. Using low energy electron microscopy (LEEM) and in situ film growth, we show that substrate temperature control permits well-controlled fabrication of either epitaxial Cr[110] films or nanocrystalline Cr layers. We show that the work function of cesium saturated nanocrystalline Cr thin-films is ~0.20 eV lower than that of epitaxial Cr[110] films. Our LEEM measurements of absorbed and reflected currents as a function of electron energy demonstrate that nanocrystallinity of cesiated chromium films results in 96% electron absorption in the range up to 1 eV above the work function, compared to just 79% absorption in cesiated crystalline Cr[110] films. These results point to metal films with suppressed crystallinity as an economical and scalable means to synthesize nanoengineered surfaces with optimized properties for next generation anode materials in high performance thermionic energy converters.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effect of substrate temperature on sputter-deposited boron carbide films

Sputter deposition of B4C films with tailored physical properties remains a challenge. Here, we systematically study how substrate temperature influences the properties of B4C films deposited by direct current magnetron sputtering onto planar substrates held at temperatures in the range of 100-510°C. Results show that all films are amorphous stoichiometric B4C, with low O content of ~1 at. %. Films deposited onto substrates at 100°C exhibit high compressive residual stress and decreased mechanical properties. Therefore, for elevated substrate temperatures in the range of 180-510°C, film mass density, surface roughness, Young’s modulus, and hardness are weakly dependent on substrate temperature. However, in this temperature range, an increase in substrate temperature leads to larger residual compressive stress accompanied by a corresponding reduction in the concentration of nanoscale inhomogeneities. At least for the landing atom ballistics conditions studied here, a substrate temperature range of ~185-250°C is optimum for growing films with near-zero intrinsic residual stress. The overall weak substrate temperature dependence of film properties revealed in this work is favorable for the development of a robust deposition process, particularly for the case of deposition onto non-planar substrates where temperature control is often challenging.

36 MATERIALS SCIENCE↗

Demonstration of improved laser preheat with a cryogenically cooled magnetized liner inertial fusion platform

We report on progress implementing and testing cryogenically cooled platforms for Magnetized Liner Inertial Fusion (MagLIF) experiments. Two cryogenically cooled experimental platforms were developed: an integrated platform fielded on the Z pulsed power generator that combines magnetization, laser preheat, and pulsed-power-driven fuel compression and a laser-only platform in a separate chamber that enables measurements of the laser preheat energy using shadowgraphy measurements. The laser-only experiments suggest that ~89% ± 10% of the incident energy is coupled to the fuel in cooled targets across the energy range tested, significantly higher than previous warm experiments that achieved at most 67% coupling and in line with simulation predictions. The laser preheat configuration was applied to a cryogenically cooled integrated experiment that used a novel cryostat configuration that cooled the MagLIF liner from both ends. Furthermore, the integrated experiment, z3576, coupled 2.32 ± 0.25 kJ preheat energy to the fuel, the highest to-date, demonstrated excellent temperature control and nominal current delivery, and produced one of the highest pressure stagnations as determined by a Bayesian analysis of the data.

47 OTHER INSTRUMENTATION↗

A liquid metal dropper for experiments on the wettability of liquid metals on plasma facing components

A liquid metal dropper has been developed as a part of the Ion-Gas-Neutral Interactions with Surfaces 2 (IGNIS-2) facility at The Pennsylvania State University. The dropper has the capability of directly applying drops to candidate plasma facing materials for nuclear fusion reactors to enable measurements of their liquid metal wetting properties. The results presented here are specific to the use of lithium in the dropper. This paper discusses the design choices of the liquid metal dropper and its chamber, including the heating and temperature control and the dropper’s motorized operation. Lithium drops of masses ranging from 0.05 g up to 0.13 g, equivalent to drop diameters between 5.6 mm to 1 cm, have been consistently dispensed by the dropper. A new algorithm is developed and used to automate the analysis of the contact angle between the liquid drops and substrate material for efficient analysis of video data recorded to study the wetting properties of candidate plasma-facing components.

Instruments & Instrumentation↗

Design improvements for a recirculating reactor: Enhanced temperature measurement and sample-isolated reactivity in steady-state kinetic studies

Building upon a previous recirculating reactor design [S.A. Tenney, K. Xie, J.R. Monnier, A. Rodriguez, R.P. Galhenage, S. Audrey, D.A. Chen, Rev. Sci. Instrum. 84, 104101 (2013)], we present significant improvements that address key limitations in steady-state kinetic measurements for heterogeneous catalysis. The enhanced reactor design features direct sample heating with a focused IR lamp and temperature measurement in direct contact with the sample, enabling more accurate temperature control and improved kinetic analysis. A critical advancement is the isolation of sample reactivity from reactor wall contributions, ensuring that only the sample contributes to measured reaction rates. This was a limitation in earlier designs where the entire reactor contributed to the observed reactivity. The system incorporates a bypass flow cell for direct comparison with powder catalysts under identical conditions using a standard plug-flow reactor configuration. We demonstrate these capabilities through CO oxidation experiments on Pt(111) single crystals and graphene-passivated Pt(111), highlighting the system's ability to differentiate catalytic activity in model systems and directly compare them with high surface area powder catalysts. This reactor is particularly suited for thin films and low surface area catalysts that are not effectively evaluated in traditional flow reactors, especially for samples with low numbers of active sites or slow reaction rates.

36 MATERIALS SCIENCE↗

Tunable diode-pumped single-frequency travelling-wave Nd : YAG laser operating at 1319 nm

A single-frequency travelling-wave Nd:YAG laser with a wide wavelength tuning range achieved due to the use of a temperature-controlled intracavity KTP filter is studied. The output laser characteristics and the frequency tuning range are presented for different operation regimes. A tuning range of 90 GHz with a tuning rate of 12 GHz Degree-Sign C is for the first time achieved for Nd :YAG lasers operating at a wavelength of 1319 nm. The output power in the centre of the gain line was {approx} 240 mW. The laser can be used in spectroscopy and metrology.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cryogenic and Temperature-Dependent Photoelectron Spectroscopy of Metal Complexes

Negative ion photoelectron spectroscopy (NIPES) coupled with electrospray ionization (ESI) has been proved to be a powerful gas-phase spectroscopic tool for characterizing electronic structures and chemical bonding of a variety of cluster anions and corresponding neutral radicals involved in the condensed phase reactions and transformations. Since the acquisition of cryogenic and temperature-controlling capabilities, broader range of research scope has been covered. This review summarizes our recent investigations on metal complexes employing cryogenic ESI-NIPES that provide us essential information towards understanding complicated condensed phase reactions including hydrocarbon activations and electron transfer reactions, and afford us spectroscopic probe of highly reactive transient species and intimate redox pairs. Special attention has been drawn to connect gas phase photodetachment processes with solution phase redox reactions. Photodetachment of transition metal-EDTA complexes has been systematically investigated to model the sequential oxidation reactions of these species in solutions. The obtained gas phase electron affinity (EA) is compared with the solution redox potential (E1/2) and the metal ionization potential (IP) for several series of homologous metal complexes to emphasize their intrinsic correlations with deviations being largely modulated by different degrees of ligand participations.

Yuan, Qinqin↗

The Primordial Inflation Explorer (PIXIE): a nulling polarimeter for cosmic microwave background observations

The Primordial Inflation Explorer (PIXIE) is a concept for an Explorer-class mission to measure the gravity-wave signature of primordial inflation through its distinctive imprint on the linear polarization of the cosmic microwave background. The instrument consists of a polarizing Michelson interferometer configured as a nulling polarimeter to measure the difference spectrum between orthogonal linear polarizations from two co-aligned beams. Either input can view the sky or a temperature-controlled absolute reference blackbody calibrator. Rhe proposed instrument can map the absolute intensity and linear polarization (Stokes I, Q, and U parameters) over the full sky in 400 spectral channels spanning 2.5 decades in frequency from 30 GHz to 6 THz (1 cm to 50 μm wavelength). Multi-moded optics provide background-limited sensitivity using only 4 detectors, while the highly symmetric design and multiple signal modulations provide robust rejection of potential systematic errors. The principal science goal is the detection and characterization of linear polarization from an inflationary epoch in the early universe, with tensor-to-scalar ratio r < 10{sup −3} at 5 standard deviations. The rich PIXIE data set can also constrain physical processes ranging from Big Bang cosmology to the nature of the first stars to physical conditions within the interstellar medium of the Galaxy.

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental evaluation of the vapor box divertor concept with an open vapor box module in Magnum-PSI

A promising approach to handle the intense plasma heat flux in the divertor region of a tokamak is the Vapor Box Divertor (VBD). Here plasma-lithium interaction creates a dense lithium vapor cloud which interacts with the incoming plasma, effectively shielding the tungsten surface beneath, therefore preventing overheating and sputtering of the tungsten and increasing the component’s lifetime. Two key steps must be addressed to validate this concept: investigating plasma-Li interactions and the transport mechanism of the latter in the presence of plasma. To explore this, a Vapor Box Module (VBM) has been designed for use with the linear plasma generator Magnum-PSI. The VBM consists of a series of three cylindrical boxes, with Li being evaporated at a controlled temperature in the central box (CB). Divertor-like plasma enters the VBM from an upstream aperture, interacts with the Li vapor cloud and exits through a downstream aperture ultimately impacting a target equipped with a calorimetry system. Optical diagnostics Thomson scattering, Filtered fast camera Imaging and optical emission spectroscopy provided information on plasma parameters in terms of electron density n e , temperature T e and plasma composition before and after this interaction. A significant reduction in plasma power was observed upon the establishment of lithium vaporization determined via cooling water calorimetry and embedded thermocouples at the downstream target. This resulted in a drop of the target temperature from ∼800 °C to ∼350 °C (57%) at the highest applied power (11.1 MW m −2 ) and CB temperature (∼700 °C). Lithium condensation at the side boxes of the VBM in combination with strong plasma momentum transfer effectively prevented upstream migration of lithium, while enhancing Li transport toward the target. The achievement of the two main goals of reducing plasma power and confining the Li in the VBM, are consistent with earlier published preliminary SOLPS-ITER simulations. This study shows that the presence of lithium in a VBD-like configuration can result in a strong reduction of power to the target surface, while at the same time the lithium vapor is effectively confined by the VBM, aided by the incoming plasma, preventing its escape from the VBM geometry. This represents a valuable step toward validating the feasibility of the VBD configuration in future fusion reactors.

Magnum-PSI↗

MAGIS-100 environmental characterization and noise analysis

We investigate and analyze site specific systematics for the MAGIS-100 atomic interferometry experiment at Fermi National Accelerator Laboratory. As atom interferometers move out of the laboratory environment passive and active mitigation for noise sources must be implemented. To inform the research and development of the experiment design, we measure ambient temperature, humidity, and vibrations of the installation site. We find that temperature fluctuations will necessitate enclosures for critical subsystems and a temperature controlled laser room for the laser system. We also measure and analyze the vibration spectrum above and below ground for the installation site. The seismic vibration effect of gravity gradient noise is also modeled using input from a low-noise seismometer at multiple locations and a mitigation scheme is studied using a stochastic simulation and characterized by a suppression factor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Current developments in soil organic matter modeling and the expansion of model applications. A review

It is important to note that Soil organic matter (SOM) is a great natural resource. It is fundamental to soil and ecosystem functions across a wide range of scales, from site-specific soil fertility and water holding capacity to global biogeochemical cycling. It is also a highly complex material that is sensitive to direct and indirect human impacts. In our SOM research, simulation models play an important role by providing a mathematical framework to integrate, examine, and test the understanding of SOM dynamics. Simulation models of SOM are also increasingly used in more ‘applied’ settings to evaluate human impacts on ecosystem function, and to manage SOM for greenhouse gas mitigation, improved soil health, and sustainable use as a natural resource. Within this context, there is a need to maintain a robust connection between scientific developments in SOM modeling approaches and SOM model applications. This need forms the basis of this review. In this review we first provide an overview of SOM modeling, focusing on SOM theory, data-model integration, and model development as evidenced by a quantitative review of SOM literature. Second, we present the landscape of SOM model applications, focusing on examples in climate change policy. Finally, we conclude by discussing five areas of recent developments in SOM modeling including: (1) microbial roles in SOM stabilization; (2) modeling SOM saturation kinetics; (3) temperature controls on decomposition; (4)SOM dynamics in deep soil layers; and (5)SOM representation in earth system models. Our aim is to comprehensively connect SOM model development to its applications, revealing knowledge gaps in need of focused interdisciplinary attention and exposing pitfalls that, if avoided, can lead to best use of SOM models to support policy initiatives and sustainable land management solutions.

54 ENVIRONMENTAL SCIENCES↗

Design of the cryogenic moderator system for the second target station

The Second Target Station (STS) at Oak Ridge National Laboratory will be a 700 kW pulsed spallation neutron source designed to provide the world's highest brightness cold neutron beams. In order to produce the required neutron performance, two compact liquid hydrogen moderators are located adjacent to the tungsten spallation target and must be supplied with less than 20 K hydrogen and a para hydrogen fraction of 99.8% or greater. The Cryogenic Moderator System (CMS) will consist of a single hydrogen loop feeding the two moderators in series cooled by a helium refrigerator with a cooling capacity of 2.5 kW at 17 K. The hydrogen loop consists of a hydrogen circulator, hydrogen helium heat exchanger, ortho-para converter, accumulator, transfer lines and heater. The design of the hydrogen loop is based on the CMS design of the First Target Station at the Spallation Neutron Source and some of the component designs may be reused. General hydrogen temperature control is provided by controlling the flowrate of helium to the heat exchanger. The hydrogen loop will have a constant flowrate of 0.5 L/s and remove a nuclear heat load of about 850 W from the two moderators, which is deposited both directly in the hydrogen and the adjacent hydrogen containing structures. Because the nuclear heat load is accelerator driven, the hydrogen system must remain stable when the heat load is removed instantaneously during beam trips. System stability is maintained passively with the accumulator and actively with the heater. Ionizing radiation which interacts with the liquid hydrogen drives backconversion of the hydrogen from parahydrogen to orthohydrogen. The STS moderator performance is very sensitive to small fractions of orthohydrogen requiring an ortho-para converter to maintain the hydrogen supplied to the moderators at near equilibrium parahydrogen concentration. STS CMS is in the early stage of preliminary design and current focus is evaluating component sizing and system stability during beam transients.

Janney, Jim↗

Precision Lifetime Measurements of He{sup -} in a Cryogenic Electrostatic Ion-Beam Trap

We have developed a small purely electrostatic ion-beam trap which may be operated in thermal equilibrium at precisely controlled temperatures down to 10 K. Thus, we avoid magnetic field induced mixing of quantum states and may effectively eliminate any influence from absorption of photons from blackbody radiation. We report the first correction-free measurement of the lifetime of the 1s2s2p {sup 4}P{sub 5/2}{sup o} level of {sup 4}He{sup -} yielding the high-precision result 359.0+-0.7 mus. This result is an essential proof-of-principle for cryogenic electrostatic storage rings and traps for atomic and molecular physics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hidden variable in the electrocaloric effect of ferroics

Caloric effects allow for temperature control through adiabatic application of external fields and are actively explored for solid-state refrigeration. The common wisdom is that the application of ultrahigh fields enhances the effects, thus providing a route to their practical applications. Here, using the ferroelectric relaxor (Ba, Ca)(Ti, Zr)O 3 , we demonstrate that in ferroics, which are the prime candidates for such application, this is not true in general and that caloric effects can be enhanced through the reduction of the applied field. The explanation of such a counterintuitive response is in the dependence of the electrocaloric effect on the effective poling field that can be regarded as a “hidden” variable of the caloric effects.

36 MATERIALS SCIENCE↗

Experimental determination of precision, resolution, accuracy and trueness of time-of-flight neutron diffraction strain measurements

We discuss a simple statistical analysis which yields the precision, resolution, accuracy and trueness of diffraction-based lattice strain measurements. The procedure consists of measuring the thermal expansion induced in each component of an ideal, non-reacting, two-component, crystalline powder sample in situ. One component, with a high coefficient of thermal expansion (CTE), serves as an internal thermometer. The quantities of interest are obtained by determining the smallest, statistically significant, thermal lattice strain which can be detected through diffraction analysis in the second, low CTE, component in response to controlled temperature changes. This procedure also provides a robust check of the alignment of the diffraction system and is able to reveal the presence of systematic errors. The application of this technique to a time-of-flight engineering diffractometer/strain scanner is presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Collaborative Decision Approach for Electricity Pricing-demand Response Stackelberg Game

Demand response programs are considered as a valuable resource in smart grids that provide several advantages of load shifting, peak load reduction, mediating intermittency of renewable energy integration, etc. Flexible price-based incentives have been recognized as a critical strategy in motivating and compensating consumers' load adjustment actions for successful implementation of demand response. Game theoretical approaches, especially Stackelberg games are popularly adopted to model the relationship between electricity price and customers' demand response and solved by the classical centralized backward induction (BI) method. However, the BI method generally requires convexity of the follower's model for necessary optimality conditions, and the computational time of any centralized approach increases sharply with larger problem instances. In this paper, the Stackelberg game of electricity pricing-demand response between a distribution system operator (DSO) and load aggregators (LAs) is decomposed based on a collaborative optimization (CO) framework, where each LA is treated as a discipline with its own domain constraints (e.g. building temperature control), while the DSO at the system level tries to reduce the solution discrepancy and guide the searching towards optimality. Several groups of comparison experiments have demonstrated the effectiveness of the proposed collaborative decision approach in solving the demand response game.

Chen, Yang↗