Search NASA⌕ Search

SEARCH · Search NASA

Results for “Two Phase Flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Turbulence measurements of high shear flow fields in a turbomachine seal configuration

The mean velocity and Reynolds stress tensor throughout a whirling annular seal are presented. The data was collected with a three dimensional laser Doppler velocimeter using phase averaging. Two axial flow conditions (Re = 12,000 and 24,000) were studied at one shaft speed (Ta = 6,600). The eccentricity and whirl ratios were 50 and 100 percent, respectively. There is a region of high axial momentum in this region is higher in the low Reynolds number case due to an axial recirculation zone that occurs on the suction side of the rotor at the inlet. The recirculation zone does not occur in the high Reynolds number case. At both Reynolds numbers, there is a recirculation zone on the rotor surface in the pressure side of the inlet. This recirculation zone extends from 20 to 200 degrees rotor zenith in the tangential direction, and is one third of a clearance wide radially. The high Reynolds number recirculation zone is 1.5 mean clearances long, while the low Reynolds number zone extends 2 mean clearances downstream. When compared to previous studies, it is apparent that the tangential momentum is no greater for a seal with whirl than for one without if other parameters are constant. Areas of high tangential momentum occur in the clearance where the axial momentum is low. Average exit plane tangential velocities in the high Reynolds number case are 1.5 times greater than those in the other flow case. These results are in general agreement with predictions made by other investigators.

Morrison, Gerald L.↗

Numerical Modeling of the Chilldown of Cryogenic Transfer Lines Using a Sinda/GFSSP Integrated Solver

An important first step in cryogenic propellant loading is the chilldown of transfer lines. During the chilldown of the transfer line, the flow is two-phase and unsteady, with solid to fluid heat transfer and therefore a coupled thermo-fluid analysis is necessary to model the system. This paper describes a numerical model of pipe chilldown that utilizes the Sinda/GFSSP Conjugate Integrator (SGCI). SGCI is a new analysis tool developed at NASA's Marshall Space Flight Center (MSFC). SGCI facilitates the solution of thermofluid problems in interconnected solid-fluid systems. The solid component of the system is modeled in MSC Patran and translated into an MSC Sinda thermal network model. The fluid component is modeled in GFSSP, the Generalized Fluid System Simulation Program. GFSSP is a general network flow solver developed at NASA/MSFC. GFSSP uses a finite-volume approach to model fluid systems that can include phase change, multiple species, fluid transients, and heat transfer to simple solid networks. SGCI combines the GFSSP Fortran code with the Sinda input file and compiles the integrated model. Sinda solves for the temperatures of the solid network, while GFSSP simultaneously solves the fluid network for pressure, temperature, and flow rate. The two networks are coupled by convection heat transfer from the solid wall to the cryogenic fluid. The model presented here is based on a series of experiments conducted in 1966 by the National Bureau of Standards (NBS). A vacuum-jacketed, 200 ft copper transfer line was chilled by liquid nitrogen and liquid hydrogen. The predictions of transient temperature profiles and chilldown time of the integrated Sinda/GFSSP model will be compared to the experimental measurements.

LeClair, Andre↗

Low-speed inducers for cryogenic upper-stage engines

Two-phase, low-speed hydrogen and oxygen inducers driven by electric motors and applicable to the tug engine were designed and constructed. The oxygen inducer was tested in liquid and two-phase oxygen. Its head and flow performance were approximately as designed, and it was able to accelerate to full speed in 3 seconds and produce its design flow and head. The analysis of the two-phase data indicated that the inducer was able to pump with vapor volume fractions in excess of 60 percent. The pump met all of its requirements (duration of runs and number of starts) to demonstrate its mechanical integrity.

Bissell, W. R.↗

Fingering flow patterns of thermosolutal convection in rectangular enclosures

Convection in rectangular enclosures with combined horizontal temperature and concentration gradients is studied. An electrochemical system is employed to impose the concentration gradients. Due to a large difference between the thermal and solutal diffusion rates the flow possesses double-diffusive characteristics. Very complex fingering flow patterns are observed around the two-phase interfaces. The main objective of the present work is to obtain more information on the flows near the two vertical phase interfaces under various parametric conditions. The fingering flows near the crystal could be one of the most important factors to cause the crystal imperfections. The ranges of the parameters studied are Sc (Schmidt number)=2200 to 2400, Pr (Prandtl number)=4.0 to 7.0, Gr sub T (Grashof number)=2.50 x 10 to the 6th to 5.10 x 10 to the 7th power, Ar (aspect ratio)=0.61 to 3.0, and N (buoyancy ratio)=0.05 to 54.8.

Wang, L. W.↗

Fingering flow patterns of thermosolutal convection in rectangular enclosures

Convection in rectangular enclosures with combined horizontal temperature and concentration gradients is studied. An electrochemical system is employed to impose the concentration gradients. Due to a large difference between the thermal and solutal diffusion rates the flow possesses double-diffusive characteristics. Very complex fingering flow patterns are observed around the two-phase interfaces. The main objective of the present work is to obtain more information on the flows near the two vertical phase interfaces under various parametric conditions. The fingering flows near the crystal could be one of the most important factors to cause the crystal imperfections. The ranges of the parameters studied are Sc (Schmidt number) = 2200 to 2400, Pr (Prandtl number) = 4.0 to 7.0, Gr sub T (Grashof number) = 2.50 x 10 to the 6th to 5.10 x 10 to the 7th power, Ar (aspect ratio) = 0.61 to 3.0, and N (buoyancy ratio) = 0.05 to 54.8.

Wang, L. W.↗

Validation Assessment of Loci/GGFS Gas Granular Flow Solver Predictions of Ejecta from Physics Focused Ground Test

NASA is preparing to return humans to the Moon to establish a sustained Lunar presence through the Artemis program. One area of concern for Lunar landers is the plume surface interaction (PSI) environment that poses several risks during a propulsive landing. Understanding the PSI environment caused by the landers is therefore important to designing successful landing missions. Towards this end, a two-phase, gas granular flow solver, Loci/GGFS, has been developed to predict the cratering and ejecta physics expected during a Lunar landing. The focus of this paper is on a validation assessment of Loci/GGFS predictions of ejecta with monodisperse glass beads (MGB). The validation assessment is performed with respect to the Physics Focused Ground Test 1 (PFGT1) conducted at NASA Marshall Space Flight Center (MSFC) in 2021. It is found that Loci/GGFS predicts similar initial cratering and ejecta features, with predictions of average velocities that are within 25% of experimental values.

Plume Surface Interaction↗

Validation Assessment of Loci/GGFS Gas Granular Flow Solver Predictions of Ejecta From Physics Focused Ground Test

NASA is preparing to return humans to the Moon to establish a sustained Lunar presence through the Artemis program. One area of concern for Lunar landers is the plume surface interaction (PSI) environment that poses several risks during a propulsive landing. Understanding the PSI environment caused by the landers is therefore important to designing successful landing missions. Towards this end, a two-phase, gas granular flow solver, Loci/GGFS, has been developed to predict the cratering and ejecta physics expected during a Lunar landing. The focus of this paper is on a validation assessment of Loci/GGFS predictions of ejecta with monodisperse glass beads (MGB). The validation assessment is performed with respect to the Physics Focused Ground Test 1 (PFGT1) conducted at NASA Marshall Space Flight Center (MSFC) in 2021. It is found that Loci/GGFS predicts similar initial cratering and ejecta features, with predictions of average velocities that are within 25% of experimental values.

Plume Surface Interaction↗

Numerical simulation of a low-emission gas turbine combustor using KIVA-II

A modified version of the KIVA-II code was used to obtain a multidimensional numerical solution for the turbulent two-phase chemically reacting flows inside a staged turbine combustor (STC). The STC under consideration is equipped with an advanced airblast fuel nozzle and encompasses a fuel nozzle (FN), a rich-burn (RB) zone, a converging connecting pipe, a quick-quench (QQ) zone, a diverging connecting pipe, and a lean-combustion (LC) zone. The STC was divided into two subsystems, namely, FN/RB zone and QQ/LC zones, and the numerical solutions were obtained separately for each subsystem. Preliminary data characterize the major features of the flow and temperature fields inside the STC. Information on velocity, temperature, and some critical species in the FN/RB zone is presented. In the QQ/LC zones, formation of the co- and counter-rotating bulk flow and the sandwiched-ring-shaped temperature field can be clearly seen. The calculations of the mass-weighted standard deviation and the pattern factor of temperature indicated that the mixing performance of the STC is very promising.

Yang, S. L.↗

Buoyant thermocapillary flow with nonuniform supra-heating. I - Liquid-phase behavior. II - Two-phase behavior

The present computational study of transient heat transfer and fluid flow in a circular pool of n-decane which is undergoing central radiative heating from above gives attention to the volumetric absorption of the radiation incident on the pool surface. The first part of this study notes that buoyancy influences the number and recirculation rates of the subsurface vortices by stabilizing hot subsurface fluid above the colder core fluid; this affects the liquid surface temperature profile and in turn governs the velocity profile that is due to thermocapillarity. In the second part, the effects of gas-liquid phase coupling, variable density and thermophysical properties, and vaporization are considered.

Schiller, David N.↗

Gas-Tolerant Device Senses Electrical Conductivity of Liquid

The figure depicts a device for measuring the electrical conductivity of a flowing liquid. Unlike prior such devices, this one does not trap gas bubbles entrained in the liquid. Usually, the electrical conductivity of a liquid is measured by use of two electrodes immersed in the liquid. A typical prior device based on this concept contains large cavities that can trap gas. Any gas present between or near the electrodes causes a significant offset in the conductivity reading and, if the gas becomes trapped, then the offset persists. Extensive tests on two-phase (liquid/ gas) flow have shown that in the case of liquid flowing along a section of tubing, gas entrained in the liquid is not trapped in the section as long as the inner wall of the section is smooth and continuous, and the section is the narrowest tubing section along the flow path. The design of the device is based on the foregoing observation: The electrodes and the insulators separating the electrodes constitute adjacent parts of the walls of a tube. The bore of the tube is machined to make the wall smooth and to provide a straight flow path from the inlet to the outlet. The diameter of the electrode/insulator tube assembly is less than the diameter of the inlet or outlet tubing. An outer shell contains the electrodes and insulators and constitutes a leak and pressure barrier. Any gas bubble flowing through this device causes only a momentary conductivity offset that is filtered out by software used to process the conductivity readings.

O'Connor, Edward W.↗

Transverse injection of a particle-laden liquid jet in supersonic flow: A three-phase flow

The results of a two part study of the behavior of particle laden liquid jets injected into air are presented. Water was used as the liquid carrier and either 1-37 or 13-44 microns diam. spherical glass beads with a specific gravity of 2.8-3.0 as the particles. The observations were mainly photographic. The breakup of jets injected into still air was investigated as a function of particle loading, and the results were compared to the pure liquid jet case. The jets were found to be more stable with particles present. The length to breakup was increased, and the formation of satellite droplets was suppressed. The penetration and breakup of transverse jets in a Mach 3.0 air stream was studied. The general breakup mechanism of wave formation was found to be the same as for the all liquid case. Significant separation of the phases was observed, and the penetration of the liquid phase was reduced compared to all liquid cases at the same value of the jet to free stream momentum flux ratio.

Schetz, J. A.↗

Cryogenic fluid flow instabilities in heat exchangers

Analytical and experimental investigation determines the nature of oscillations and instabilities that occur in the flow of two-phase cryogenic fluids at both subcritical and supercritical pressures in heat exchangers. Test results with varying system parameters suggest certain design approaches with regard to heat exchanger geometry.

Fleming, R. B.↗

Test of sodium boiling in a single tube-in- shell heat exchanger over the range 1720 deg to 1980 deg F /1211 to 1355 K/

Sodium was boiled in a vertical, 1/2-inch (1.27-cm) inside diameter by 4-fOOt (1.22-m) long tube. The columbium alloy boiler operated at flow rates of 75 to 380 lbm/hr (9.4 to 48 g/sec) and up to 0.93 quality. Boiling performance depended on whether the inlet flow was two-phase or liquid. Two-phase momentum pressure drops were 1(1/2) times frictional drops. Qualities over 0.9 were obtained at some critical (burnout) boiling conditions. Liquid superheats up to 250° F (139 K) existed before initiation of boiling.

James P. Lewis↗

On the aerothermodynamic study of the SSME HPOTP ball bearing inside a vapor film

In order to predict ball bearing temperature in the Space Shuttle Main Engine (SSME) high-pressure oxidizer turbopump (HPOTP), knowledge of ball bearing heat transfer coefficients is important. To understand the heat transfer behavior of a ball bearing operating under a two-phase environment, a flow simulation model of a rotating sphere inside a vapor film has been developed to determine the effects of rotational speed and vapor film thickness on ball heat transfer. The calculated Nusselt number is compared with experimental data for a rotating ball in liquid nitrogen.

Shieh, C. Y.↗

Heavy rain effects on airplane performance

The objective is to determine if the aerodynamic characteristics of an airplane are altered while flying in the rain. Wind-tunnel tests conducted at the NASA Langley Research Center (LaRC) have shown losses in maximum lift, reduction in stall angle, and increases in drag when a wing is placed in a simulated rain spray. For these tests the water spray concentration used represented a very heavy rainfall. A lack of definition of the scaling laws for aerodynamic testing in a two-phase, two-component flow makes interpolation of the wind-tunnel test uncertain. Tests of a large-scale wing are to be conducted at the LaRC. The large-scale wing is mounted on top of the Aircraft Landing Dynamics Facility (ALDF) carriage. This carriage (which is 70-foot long, 30-foot wide, and 30-foot high) is propelled with the wing model attached down a 3000-foot long test track by a water jet at speeds of up to 170 knots. A simulated rain spray system has been installed along 500 feet of the test track and can simulate rain falls from 2 to 40 inches/hour. Operational checks are underway and the initial tests should be completed by the Fall of 1989.

Dunham, R. E., Jr.↗

Cryogenic foil bearing turbopumps

Cryogenic foil bearing turbopumps offer high reliability and low cost. The fundamental cryogenic foil bearing technology has been validated in both liquid hydrogen and liquid oxygen. High load capacity, excellent rotor dynamics, and negligible bearing wear after over 100 starts and stops, and over many hours of testing, were observed in both fluids. An experimental liquid hydrogen foil bearing turbopump was also successfully demonstrated. The results indicate excellent stability, high reliability, wide throttle-ability, low bearing cooling flow, and two-phase bearing operability. A liquid oxygen foil bearing turbopump has been built and is being tested at NASA MSFC.