Search NASA⌕ Search

SEARCH · Search NASA

Results for “Unity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

A Novel AC to AC Wireless Power Transfer System for EV Charging Applications

In this paper, a novel ac to ac wireless power transfer (WPT) system is introduced for electric vehicle (EV) charging applications to reduce cost and design complexity. The presented wireless power transfer concept achieves unity power factor (UPF) on the grid-side by using a hybrid frequency ac / ac converter without an additional converter stage and closed loop control compared to the conventional systems. Due to inherent merit of the proposed ac / ac converter, ac input with 60 Hz grid frequency can be directly transferred to the load by superimposing with high frequency switching signal through the wireless coils. To validate the theoretical analysis of the proposed WPT system, the experimental results of the proposed converter are provided for 650 W output power by using 6 inches air gap between the couplers with the input of 110 VRMS ac source. The system overall efficiency is measured 89 % achieving 0.99 power factor (PF) and 1.5 % current total harmonic distortion (THD).

Asa, Erdem↗

A Transformer Flux Balancing Scheme Based on Magnetizing Current Harmonic in Dual-Active-Bridge Converters

The Dual-Active-Bridge (DAB) converter transformer flux unbalance, or dc bias, could be a critical issue due to the mismatches of converter circuit parameters and control transients. In this paper, a steady-state flux balancing scheme, based on the second-order harmonic of magnetizing current has been proposed. The relationship between steady-state flux/magnetizing current unbalance and its harmonic contents has been analyzed, with which a new current sensing method and control strategy are introduced. The proposed magnetizing current sensing method can be implemented for both unity and complicated fractional turns ratios, without high sensitivity to dc offset from the analog circuitry. The proposed scheme has been validated with experimental results on 850-V/850-V DAB converters within a system, as well as in an 850-V/6700-V medium voltage DAB unit.

Gao, Zihan↗

A Novel Three-Phase Oak Ridge AC / AC Converter for Wireless Mobility Energy Storage System (WMESS) Connectivity

In this study, a novel three-phase Oak Ridge ac to ac converter is introduced for wireless mobility energy storage system (WMESS) applications for grid support or ancillary service applications. The proposed topology can be used in bidirectional operation between ac grid and ac terminals of energy storage (output of the ESS inverter) by accomplishing unity power factor. Inherent merit of the technology is that it can directly merge ac input 60 Hz grid frequency with the high frequency by superimposing them with the Oak Ridge Converter (ORC) and through the wireless coils. Theoretical and simulation results are provided for 10 kW output power. The functionality of the proposed three-phase system is demonstrated with the coupling coils separated by 6 inches of air gap with the input / output of 277 V AC,RMS . The system overall design is presented, and simulation results demonstrate achieving 3% current total harmonic distortion (THD) and 0.99 power factor (PF) at full load of 10 kW wireless power transfer.

Asa, Erdem↗

Optimal Modulation and DM Filter Design for a High Switching Frequency Single-Stage Microinverter

This paper presents an optimal modulation and systematic filter design approach for a single-stage dual-active-bridge (DAB) based dc-ac microinverter to achieve improved differential-mode (DM) noise performance for electromagnetic interference (EMI) tests. As DM filters contribute significantly to the overall converter volume, the main objective of this work is to leverage the degrees of freedom in the DAB converters to effectively attenuate the EMI noise. In addition, the DM filter design method needs to ensure near unity power factor converter operation. To achieve these targets, this paper analyzes three modulation strategies based on fixed or variable switching frequency operation where the different control modulation variables are varied to find the simulated DM noise spectrum. Based on the required DM attenuation, a constrained optimization problem is formulated to determine minimal DM filter parameters. Simulation results show that a spread spectrum approach with variable switching frequency is shown to minimize the DM EMI attenuation effort by spreading the noise profile. A fully GaN 400 W hardware prototype demonstrated the spread-sprectrum approach.

14 SOLAR ENERGY↗

Skipper-CCD Output Sensitivity Improvement with a Common Source Cascode Amplifier

A Skipper-CCD output has been traditionally readout in a source follower configuration, also known as common drain, mainly because in this configuration a good compromise between sensitivity, noise and speed is achieved. In this work a different approach is presented: the output transistor is connected in a common source configuration and an external cascode device is added in series, obtaining a voltage gain higher than unity without increasing significantly the parasitic capacitance due to Miller effect and thus increasing the obtained voltage per electron of charge. The proposed output stage improves the sensitivity 3.4 times when compared with the traditionally used stage while keeping almost the same equivalent noise charge.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Operation and Control of a Back to Back Modular Multilevel Converter System for Grid Forming Application with Advanced Grid Support Functionalities

The main focus of this paper is to investigate the possibility of using modular multilevel converter based back-to-back system for grid forming applications. A decentralized hierarchical control architecture with a modified local controller based on nonlinear techniques for grid forming application have been investigated. Grid functionalities based on IEEE 1547-2018 for grid forming converters have been utilized. The local controllers ensure distortion free balanced sinusoidal output voltage on the grid forming side with unbalanced or nonlinear loading condition. The grid following side ensures unity power factor currents under unbalanced grid voltage condition. The dc bus voltage control ensures oscillation free voltage under balanced conditions and control of the average voltage under unbalanced condition. Efficacy of the overall system is verified by modeling the system in MATLAB/Simulink and PLECS domain and the most important case studies are presented.

advanced grid support functionalities↗

Secondary Active Rectifier Control Scheme for a Wireless Power Transfer System with Double-Sided LCC Compensation Topology

This paper proposes a secondary control method using an active rectifier for a double-sided LCC tuned wireless power transfer system (WPT) to reduce the communication requirements of the system. As the active rectifier regulates the output power with a constant primary coil current, the secondary circulating time interval is adjusted while maintaining a unity power factor. First, circuit modelling and sensitivity analyses for the voltage gain, input impedance, coil current rating and power transfer are investigated with a design example of 20kW WPT. Subsequently, the control scheme is developed by considering the four operation modes with the phase difference as the control variable. To prove the effectiveness of the proposed control method, a simulation model is built, and the results demonstrate good dynamic performance with high accuracy for voltage regulation. Compared with the conventional secondary control, it improves the performance of the system along with a well-developed converter gain by maintaining the equivalent load resistive and reduced circulating time intervals, which further improves the system efficiency. The proposed system also eliminates the need for an additional de/de converter on the secondary side.

Zou, Shenli↗

Power Converter Topologies for Electrolyzer Applications to Enable Electric Grid Services

Hydrogen electrolyzers, with their operational flexibility, can be configured as smart dynamic loads which can provide grid services and facilitate the integration of more renewable energy sources into the electrical grid. However, to enable this ability, the electrolyzer system should be able to control both active and reactive power in coordination with the low-level controller of the electrolyzer via the power electronics system interface between the utility grid and electrolyzer. This paper discusses power converter topologies and the control scheme of this power electronics interface for electrolyzer applications to enable electricity grid services. For the sake of unity, in this paper, we consider the power converter system interfacing the utility grid at the line-to-line root mean square (RMS) value of 480 VAC-60 Hz and supplying to the 3500 A-750 kW PEM electrolyzer stack.

electrolyzer↗

A Novel Three Phase Oak Ridge DC / AC Converter for Wireless Grid Tied Applications

In this study, a novel three phase oak ridge dc to ac converter is introduced for wireless mobility energy storage (WMES) applications to support the grid demand during peak times. The proposed topology can be used in a bi-directional operation between ac grid and dc terminals of energy storage by accomplishing unity power factor. Inherent merit of the technology can directly merge dc input to the high frequency and 60 Hz grid frequency by superimposing through the wireless coils. Theoretical and simulation results are validated by the simulation analysis for 20 kW output power. The functionality of the proposed three phase system is established by using 6 inches air gap between the couplers with the input of 675 V DC and output of 277 V AC, RMS . The system overall design analysis is demonstrated for simulation analysis and simulation results are presented achieving 3% current total harmonic distortion (THD) and 0.99 power factor (PF) at full load 20 kW wireless power transfer.

Asa, Erdem↗

Uniform Mechanical Loading Can Test for Nonuniform Loading Durability

In this work, we present a method to evaluate the equivalency between any module mechanical loading conditions. The method is developed to address the specific failure mode of glass fracture and is based on Weibull analysis and weakest link theory. It considers the varying stress profile across the module to calculate the probability of glass fracture, which is used as the metric of equivalency. An idealized nonuniform loading scheme is employed to demonstrate the method and introduce the concept of the equivalent uniform load factor: a factor applied to the maximum pressure of the nonuniform load to obtain the equivalent uniform load value. It is demonstrated that this factor is less than unity for all nonuniform load cases considered, including snow and various characters of wind loading. These significant results suggest that uniform loading may be reliably, and practically, employed to evaluate photovoltaic module glass for nonuniform loading durability.

14 SOLAR ENERGY↗

Inverter Reliability Estimation for Advanced Inverter Functionality

In the near future, grid operators are expected to regularly use advanced distributed energy resource (DER) functions, defined in IEEE 1547-2018, to perform a range of grid-support operations. Many of these functions adjust the active and reactive power of the device through commanded or autonomous modes, which will produce new stresses on the grid-interfacing power electronics components, such as DC/AC inverters. In previous work, multiple DER devices were instrumented to evaluate additional component stress under multiple reactive power setpoints. We utilize quasi-static time-series simulations to determine voltage-reactive power mode (volt-var) mission profile of inverters in an active power system. Mission profiles and loss estimates are then combined to estimate the reduction of the useful life of inverters from different reactive power profiles. It was found that the average lifetime reduction was approximately 0.15% for an inverter between standard unity power factor operation and the IEEE 1547 default volt-var curve based on thermal damage due to switching in the power transistors. For an inverter with an expected 20-year lifetime, the 1547 volt-var curve would reduce the expected life of the device by 12 days. This framework for determining an inverter's useful life from experimental and modeling data can be applied to any failure mechanism and advanced inverter operation.

component degradation↗

Microinhomogeneities in Semi-Insulating Cd(Zn)Te

Here, we investigated the temperature dependences (TDs) in the range of 290-423 K for the Hall constant R H and the Hall carrier mobility μn (σ R H ) in semi-insulating Cd 0.9 Zn 0.1 Te:In (CZT) crystals. As-grown, CZT material has nonequilibrium distributions of native and impurity-related defects. Thus, before taking any measurements, the samples were kept inside the test chamber in the dark at 423 K to reach an equilibrium state at T <; 423 K. For all the tested samples, the R H TD could be described by two activation energies. At the transitional point, the TD of the carrier mobility also changes from “normal” at high temperatures to “exponential” at low temperatures. The latter is a result of the collective effect of drift barriers due to microinhomogeneity. Therefore, only the high-temperature activation energies can be assigned to the ionization energies of the compensated deep donors (ε D ). For different samples, the values for ε D 0 (at absolute zero) were found to be in the range of 0.50-0.78 eV, and the degree of donor compensation [D + ]/[D] is between 0.3 and 0.98. The low-temperature region, where there are strong effects of crystal microinhomogeneities, cannot be used to characterize the ionization energy of donors. Therefore, we describe the activation energy as ε 1 = ε D - αε b , where ε b is the drift barrier height found from the TD of the carrier mobility and α takes a value close to unity. Values of ε b for our studied samples lie within (0.05-0.35) eV.

36 MATERIALS SCIENCE↗

Analysis and Mitigation of Cascading Failures Using a Stochastic Interaction Graph with Eigen-analysis

In studies on complex network systems using graph theory, eigen-analysis is typically performed on an undirected graph model of the network. However, when analyzing cascading failures in a power system, the interactions among failures suggest the need for a directed graph beyond the topology of the power system to model directions of failure propagation. To accurately quantify failure interactions for effective mitigation strategies, this paper proposes a stochastic interaction graph model and associated eigen-analysis. Different types of modes on failure propagations are defined and characterized by the eigenvalues of a stochastic interaction matrix, whose absolute values are unity, zero, or in between. Finding and interpreting these modes helps identify the probable patterns of failure propagation, either local or widespread, and the participating components based on eigenvectors. Then, by lowering the failure probabilities of critical components highly participating in a mode of widespread failures, cascading can be mitigated. Here, the validity of the proposed stochastic interaction graph model, eigen-analysis and the resulting mitigation strategies is demonstrated using simulated cascading failure data on an NPCC 140-bus system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Hybrid Fuel Cell and Battery Storage Power Management for Grid-Interactive EV Charging Station

With the increasing adoption of renewable energy sources in grid-interactive Electric Vehicle (EV) charging stations, the role of energy storage systems has become critical. While large energy storage systems have mitigated the intermittency of renewable energy, integrating multi-source energy management with prioritized charging can further enhance the reliability of charging stations (CS). This paper presents a decentralized energy management (DEM) approach combining battery energy storage (BES) and fuel cell (FC) systems using a rule-based line resistance correction droop (LRCD) control technique. The proposed droop control dynamically adjusts the gain to balance the state-of-charge (SoC) of the BES, enhancing power support longevity and improving battery life under varying capacity conditions by reducing current stress. Additionally, the paper addresses the challenges of using fuel cells in linear regions to optimize efficiency and manage various charging scenarios. The CS integrates unity power factor grid interaction, and power support for auxiliary loads, maintaining harmonic distortion within 5% during grid islanding. The approach evaluates DC bus voltage regulation under various scenarios of PV array power fluctuations and dynamic load variations, in both grid-connected and standalone operations. In conclusion, the proposed control strategy is validated on a laboratory prototype through various dynamic load variation and grid islanding scenarios.

Khalid, Mohd [Oak Ridge National Laboratory (ORNL)↗

Otolith 87 Sr / 86 Sr identifies natal origin, movement and life history of Burbot Lota lota in the Kootenai River following 45 years of impoundment

Abstract Hydropower has long been an effective form of renewable energy, but the development of the resource has negatively impacted fishes throughout the world. Formulating recovery plans to mitigate these effects requires a firm understanding of species‐specific provenance, life history and life stage habitat requirements. However, the importance of this information is often only recognised after a substantial population decline, when obtaining it becomes demographically challenging. We provide a case study for this scenario and present a post hoc approach to gain insight into these critical data gaps for Burbot Lota lota in the upper Kootenai River in Montana and British Columbia. The population once supported a robust tribal and recreational harvest but declined following impoundment and these fisheries have remained closed or curtailed for nearly 20 years. The reasons for the decline are unknown and actions to assist recovery have been constrained by limited information regarding natal origin, life history and habitat use. We addressed this issue using strontium isotope ratios ( 87 Sr/ 86 Sr) in otoliths collected over four decades in Lake Koocanusa, the reservoir on the Kootenai River above Libby Dam. Due to the geologic heterogeneity of the basin and resulting variation in water 87 Sr/ 86 Sr, the assignment probability for Burbot to their region of natal origin approached unity. Otolith 87 Sr/ 86 Sr also indicated the population was comprised of mainstem‐ and tributary‐origin forms and their relative abundance changed over time. Mainstem Burbot was most abundant during the 1970s and 2000s, whereas tributary forms dominated between these periods. We suggest ecosystem changes following impoundment contributed to this shift in life history forms and the overall decline of the population. Our findings underscore the need for additional investigations of these impacts to guide restoration efforts.

Dunnigan, James L.↗

Sweeping Jet Film Cooling on a Turbine Vane

The cooling performance of sweeping jet film cooling was studied on a turbine vane suction surface in a low-speed linear cascade wind tunnel. The sweeping jet holes consist of fluidic oscillators with an aspect ratio (AR) of unity and a hole spacing of Pd/D = 6. Infrared (IR) thermography was used to estimate the adiabatic film effectiveness at several blowing ratios and two different freestream turbulence levels (Tu = 0.3% and 6.1%). Convective heat transfer coefficient was measured by a transient IR technique, and the net heat flux benefit was calculated. The total pressure loss due to sweeping jet film cooling was characterized by traversing a total pressure probe at the exit plane of the cascade. Tests were performed with a baseline shaped hole (SH) (777-shaped hole) for comparison. The sweeping jet hole showed higher adiabatic film effectiveness than the 777-shaped hole in the near hole region. Although the unsteady sweeping action of the jet augments heat transfer, the net positive cooling benefit is higher for sweeping jet holes compared to 777 hole at particular flow conditions. The total pressure loss measurement showed a 12% increase in total pressure loss at a blowing ratio of M = 1.5 for sweeping jet hole, while 777-shaped hole showed a 8% total pressure loss increase at the corresponding blowing ratio.

Engineering↗

A General Study of Counterflow Diffusion Flames for Supercritical CO2 Combustion

Abstract A counterflow diffusion flame for supercritical CO2 combustion is investigated at various CO2 dilution levels and pressures by accounting for real gas effects into both thermal and transport properties. The UCF 1.1 24-species mechanism is used to account the chemistry. The nature of important nonpremixed combustion characteristics such as Prandtl number, thermal diffusivity, Lewis number, stoichiometric scalar dissipation rate, flame thickness, and Damköhler number are investigated with respect to CO2 dilution and pressure. The results show that the aforementioned parameters are influenced by both dilution and pressure; the dilution effect is more dominant. Further, the result shows that Prandtl number increases with CO2 dilution and at 90% CO2 dilution, the difference between the Prandtl number of the inlet jets and the flame is minimal. Also, the common assumption of unity Lewis number in the theory and modeling of nonpremixed combustion does not hold reasonable for sCO2 applications due to large difference of Lewis number across the flame and the Lewis number on the flame drop significantly with an increase in the CO2 dilution. An interesting relation between Lewis number and CO2 dilution is observed. The Lewis number of species drops by 15% when increasing the CO2 dilution by 30%. Increasing the CO2 dilution increases both the flow and chemical timescales; however, chemical timescale increases faster than the flow timescales. The magnitudes of the Damköhler number signify the need to consider finite rate chemistry for sCO2 applications. Further, the Damköhler numbers at 90% sCO2 dilution are very small; hence, laminar flamelet assumptions in turbulent combustion simulations are not physically correct for this application. Also, it is observed that the Damköhler number drops nonlinearly with increasing CO2 dilution in the oxidizer stream. This is a very important observation for the operation of sCO2 combustors. Further, the flame thickness is found to increase with CO2 dilution and reduce with pressure.

Engineering↗

Multidimensional Numerical Modeling of Combustion Dynamics in a Non-Premixed Rotating Detonation Engine With Adaptive Mesh Refinement

In the present work, a novel computational fluid dynamics (CFD) methodology was developed to simulate full-scale non-premixed rotating detonation engines (RDEs). A unique feature of the modeling approach was the incorporation of adaptive mesh refinement (AMR) to achieve a good trade-off between model accuracy and computational expense. Here, unsteady Reynolds-averaged Navier–Stokes (RANS) simulations were performed for an Air Force Research Laboratory (AFRL) non-premixed RDE configuration with hydrogen as fuel and air as the oxidizer. The finite-rate chemistry model, along with a ten-species detailed kinetic mechanism, was employed to describe the H 2 -Air combustion chemistry. Three distinct operating conditions were simulated, corresponding to the same global equivalence ratio of unity but different fuel/air mass flowrates. For all conditions, the capability of the model to capture essential detonation wave dynamics was assessed. An exhaustive verification and validation study was performed against experimental data in terms of a number of waves, wave frequency, wave height, reactant fill height, oblique shock angle, axial pressure distribution in the channel, and fuel/air plenum pressure. The CFD model was demonstrated to accurately predict the sensitivity of these wave characteristics to the operating conditions, both qualitatively and quantitatively. A comprehensive heat release analysis was also conducted to quantify detonative versus deflagrative burning for the three simulated cases. The present CFD model offers a potential capability to perform rapid design space exploration and/or performance optimization studies for realistic full-scale RDE configurations.

42 ENGINEERING↗