Search NASA⌕ Search

SEARCH · Search NASA

Results for “analyzable function”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Application of several methods for determining transfer functions and frequency response of aircraft from flight data

In the process of analyzing the longitudinal frequency-response characteristics of aircraft, information on some of the methods of analysis has been obtained by the Langley Aeronautical Laboratory of the National Advisory Committee for Aeronautics. In the investigation of these methods, the practical applications and limitations were stressed. In general, the methods considered may be classed as: (1) analysis of sinusoidal response, (2) analysis of transient response as to harmonic content through determination of the Fourier integral by manual or machine methods, and (3) analysis of the transient through the use of least-squares solutions of the coefficients of an assumed equation for either the transient time response or frequency response (sometimes referred to as curve-fitting methods). (author)

Eggleston, John M↗

Thermal and Kinetic Properties of Motions in a Prominence Activation and Nearby Loop

We perform a quantitative analysis of the thermal properties of a prominence activation and motions in a nearby loop. In order to make measurements of the quickly moving features seen in prominences in the UV we use the SOHO/SUMER spectrograph to take a time series of exposures from a single pointing position, providing a measurement of spectral line properties as a function of time and position along the slit. The lines observed cover a broad range of temperatures from 80,000 - 1.6 million K. These measurements are combined with TRACE movies in transition region and coronal temperature bands to obtain more complete information concerning prominence structure and motions. The resulting observations allow us to analyze the thermal and kinetic energy of the moving sources as functions of time. The loop and prominence are most apparent in lines formed at temperatures below 250,000 K. We find that in most cases the temperature distribution of plasma in a moving feature changes relatively little over time periods of about 20 minutes.

Kucera, Therese↗

Simulated response of a multispectral scanner over wheat as a function of wavelength and view/illumination direction

The reflectance response with view angle of wheat, was analyzed. The analyses, which assumes there are no atmospheric effects, and otherwise simulates the response of a multispectral scanner, is based upon spectra taken continuously in wavelength from 0.45 to 2.4 micrometers at more than 1200 view/illumination directions using an Exotech model 20C spectra radiometer. Data were acquired six meters above four wheat canopies, each at a different growth stage. The analysis shows that the canopy reflective response is a pronounced function of illumination angle, scanner view angle and wavelength. The variation is greater at low solar elevations compared to high solar elevations.

Bauer, M. E.↗

ISS Technology Demonstrations for Future Spaceflight Medical Systems

Throughout the history of human spaceflight, crewmembers have experienced various in-flight medical conditions including illness and injury. Planned missions to the Moon and Mars will require capabilities to maintain the health of future space travelers. Mass, power, and volume available in the vehicles and habitats for these missions will be severely constrained; resupply of resources will be limited or non-existent, as will opportunities for evacuation to Earth. Furthermore, ground-based support will be hampered by communication latencies and blackouts. These vehicle and mission constraints will necessitate a medical system that has been efficiently planned, providing on-board procedural guidance in addition to a variety of medical devices and consumable resources. Medical capabilities required for the diagnosis and treatment of potential medical conditions during future spaceflight missions may include real-time health monitoring, medical imaging, and biomarker analyses ( e.g., blood or urine). Terrestrial medicine shares these needs, thus many of these medical capabilities could likely be satisfied by Commercial-Off-The-Shelf (COTS) devices and methodologies; however, in some cases the unique space environment and increased mission duration will drive the need to modify technologies and the way care is provided. NASA’s Human Research Program (HRP) Exploration Medical Capability (ExMC) Element and Mars Campaign Office’s Exploration Medical Integrated Product Team (XMIPT) are working together to decrease medical risk during exploration missions. Flight-tested medical diagnostic and treatment technologies are necessary to effectively manage medical conditions relevant to exploration missions while meeting vehicle constraints, integrating with medical decision-support tools, and enabling increasingly Earth-independent operations. Several projects have leveraged the ISS as a testbed for exploration, including 1) i n- situ blood analysis, 2) medical inventory, 3) intravenous fluid generation, and 4) autonomous medical procedure guidance. Management of several in-flight medical conditions, such as bacterial and viral infections and acute radiation syndrome, is dramatically improved with ability to assess blood cell populations, electrolytes, and metabolites. I n December 2020 and January 2021 ExMC performed an ISS technology demonstration (Tech Demo) of the HemoCue® WBC DIFF analyzer (HemoCue, Brea, CA), a COTS device that was modified to enable functionality in a spaceflight environment. This Tech Demo marked the first time that hematology measurements were successfully performed real-time in microgravity. Also modified and demonstrated was the reusable Handheld Electrolytes and Lab Technology for Humans (rHEALTH) ONE analyzer (rHEALTH, Bedford, MA), which uses flow cytometry and sheath-based hydrodynamic focusing methodologies. The rHEALTH ONE ISS Tech Demo in May 2022 demonstrated test results obtained in-flight matched those on the ground. NASA currently relies on crew self-reporting to manage and maintain medical inventory on ISS.The ability to maintain an accurate inventory becomes more critical during long duration missions since the crew will need to be increasingly autonomous in finding and utilizing medical items, including those scenarios when alternative treatments need to be considered due to limited or no resupply. HRP’s Medical Consumables Tracking (MCT) project was developed by ZIN Technologies, Inc. (Cleveland, OH), and demonstrated real-time tracking of medical supplies aboard the ISS between December 2016 and July 2018. The MCT system design utilized Radio Frequency Identification Device (RFID) technology to perform automated inventory and was installed in the Crew Health Care System (CHeCS) Resupply Stowage Rack (RSR). The challenge of limited shelf life, exacerbated by the lack of resupply opportunities, affects a plethora of medical system components including consumables, pharmaceuticals, and intravenous (IV) fluid. In 2010, ExMC funded ZIN Technologies, Inc. (Cleveland, OH), to develop the Intravenous Fluid Generation (IVGEN) system. IV fluids were successfully generated with IVGEN using the potable water supply on ISS during ISS Expedition 23. The XMIPT is in the process of developing a miniaturized version of the original IVGEN hardware for a future Tech Demo aboard the ISS. Current ISS medical operations rely heavily on preflight training and real-time remote guidance, both of which become impractical or impossible for exploration missions. The primary goal of the Autonomous Medical Officer Support (AMOS) Software Tech Demos on ISS was to confirm telemedical proof-of-concept for autonomous medical imaging in an operational setting. This novel software tool shifts emphasis from preflight training and real-time remote guidance to in-flight just-in-time instruction, a new and necessary paradigm for crew medical autonomy. AMOS introduces a novel, streamlined skill management concept for exploration missions featuring comprehensive training and guidance modules for ultrasound examinations using the ISS Ultrasound 2 (a modified GE Vivid-q™; General Electric HealthCare, Chicago, IL). With no prior crew training or remote guidance, two Tech Demos on the ISS (April 2020 and June 2022) resulted in high quality, clinically useful image sets. We will provide a review of historical, current, and planned medical devices and technologies considered for inclusion within future spaceflight medical systems and summarize hardware development activities and medical device tech demos conducted on the ISS.

Astronaut health and performance↗

Water vapor variance measurements using a Raman lidar

Because of the importance of atmospheric water vapor variance, we have analyzed data from the NASA/Goddard Raman lidar to obtain temporal scales of water vapor mixing ratio as a function of altitude over observation periods extending to 12 hours. The ground-based lidar measures water vapor mixing ration from near the earth's surface to an altitude of 9-10 km. Moisture profiles are acquired once every minute with 75 m vertical resolution. Data at each 75 meter altitude level can be displayed as a function of time from the beginning to the end of an observation period. These time sequences have been spectrally analyzed using a fast Fourier transform technique. An example of such a temporal spectrum obtained between 00:22 and 10:29 UT on December 6, 1991 is shown in the figure. The curve shown on the figure represents the spectral average of data from 11 height levels centered on an altitude of 1 km (1 plus or minus .375 km). The spectra shows a decrease in energy density with frequency which generally follows a -5/3 power law over the spectral interval 3x10 (exp -5) to 4x10 (exp -3) Hz. The flattening of the spectrum for frequencies greater than 6x10 (exp -3) Hz is most likely a measure of instrumental noise. Spectra like that shown in the figure are calculated for other altitudes and show changes in spectral features with height. Spectral analysis versus height have been performed for several observation periods which demonstrate changes in water vapor mixing ratio spectral character from one observation period to the next. The combination of these temporal spectra with independent measurements of winds aloft provide an opportunity to infer spatial scales of moisture variance.

Evans, K.↗

The effects of digitizing rate and phase distortion errors on the shock response spectrum

Some of the methods used for acquisition and digitization of high-frequency transients in the analysis of pyrotechnic events, such as explosive bolts for spacecraft separation, are discussed with respect to the reduction of errors in the computed shock response spectrum. Equations are given for maximum error as a function of the sampling rate, phase distortion, and slew rate, and the effects of the characteristics of the filter used are analyzed. A filter is noted to exhibit good passband amplitude, phase response, and response to a step function is a compromise between the flat passband of the elliptic filter and the phase response of the Bessel filter; it is suggested that it be used with a sampling rate of 10f (5 percent).

Wise, J. H.↗

Prominence Energetics Measured with SOHO/SUMER and TRACE

The mechanisms by which solar prominences are filled with plasma are still undetermined. In this study we perform a quantitative analysis of the thermal properties of moving features in prominences in order to put constraints on models of prominence formation and dynamics. In order to make such measurements of the quickly moving features seen in prominences in the W we use the SOHO/SUMER spectrograph to take a time series of exposures from a single pointing position, providing a measurement of spectral line properties as a function of time and position along the slit. temperatures from 80,000 - 1.6 million K. These measurements are combined with TRACE movies in transition region and coronal temperature bands to obtain more complete information concerning prominence structure and motions. The resulting observations allow us to analyze the thermal and kinetic energy of the moving prominence sources as functions of time.

Kucera, T.↗

Program for the analysis of time series

A digital computer program for the Fourier analysis of discrete time data is described. The program was designed to handle multiple channels of digitized data on general purpose computer systems. It is written, primarily, in a version of FORTRAN 2 currently in use on CDC 6000 series computers. Some small portions are written in CDC COMPASS, an assembler level code. However, functional descriptions of these portions are provided so that the program may be adapted for use on any facility possessing a FORTRAN compiler and random-access capability. Properly formatted digital data are windowed and analyzed by means of a fast Fourier transform algorithm to generate the following functions: (1) auto and/or cross power spectra, (2) autocorrelations and/or cross correlations, (3) Fourier coefficients, (4) coherence functions, (5) transfer functions, and (6) histograms.

Brown, T. J.↗

A Low Cost Thermal Control Method for Testing in a Mars Environment

Due to the unique thermal vacuum testing requirements for a Mars Rover instrument, NASA Goddard developed a low cost, high fidelity thermal control system utilizing Thermal Electric Coolers (TECs) combined with a heat rejection fluid loop to actively control 8 independent payload thermal boundary zones in a simulated Mars pressure vacuum chamber with a Carbon Dioxide atmosphere. These zones could control instrument components to a specific temperature as a function of time to simulate exact temporal flight boundary predictions.The Mars Organic Molecule Analyzer (MOMA) instrument is a dual source (pyrolysis gas chromatograph and laser desorption) mass spectrometer (MS) based package that detects and characterizes organic molecules, as part of ESA's 2020 ExoMars Rover mission to seek the signs of life on Mars.Due to the unique thermal vacuum testing requirements for a Mars Rover instrument, NASA Goddard developed a low cost, high fidelity thermal control system utilizing Thermal Electric Coolers (TECs) combined with a heat rejection fluid loop to actively control 8 independent payload thermal boundary zones in a simulated Mars pressure vacuum chamber with a Carbon Dioxide atmosphere. These zones could control instrument components to a specific temperature as a function of time to simulate exact temporal flight boundary predictions.The Mars Organic Molecule Analyzer (MOMA) instrument is a dual source (pyrolysis gas chromatograph and laser desorption) mass spectrometer (MS) based package that detects and characterizes organic molecules, as part of ESA's 2020 ExoMars Rover mission to seek the signs of life on Mars.

MOMA↗

The Bennett ion-mass spectrometer on Atmosphere Explorer-C and -E.

The Bennett spectrometer to be flown on Atmosphere Explorer-C and -E (AE-C and AE-E) is designed to measure, throughout the 120 to 4000-km orbit, the concentrations of all thermal positive ions in the mass range 1 to 72 amu and number density range 5 to 5,000,000 ions per cu cm. To reduce the buildup of ram pressure and facilitate measurements at low altitude, the analyzer is vented, and a multigrid ion-current collector is employed. An extensive command capability permits optimization of instrument parameters for particular measurement objectives; commandable functions include mass-scan range and period, the sensitivity-resolution characteristic of the analyzer, orifice potential, and in-flight calibration.

Brinton, H. C.↗

SIM spectral characteristics and accuracy analysis

The Space Interferometry Mission (SIM) will perform global astrometry (full sky), local wide-angle (15 degree) and narrow-angle (1 degree) observations to search extra-solar planets, and can calibrate stellar and galactic evolution theories. The astrometric accuracy of the SIM mission depends on spectral characteristics of the optics, detectors and targets. This paper will discuss the photometric throughput of the SIM instrument, and analyze effects of wavefront errors, optical mismatches and control biases as a function of wavelength. The color dependence models of the instrument optics including mirrors, lenses, field-stop and beam-splitter are presented. The performances of different detectors with a variety of coatings are compared. A model of the SIM fringe spectrometer is created. For early and late types of stars, brightness dependency errors are analyzed for different combinations of optics and detectors. Visibility loss due to imperfect optics is investigated in detail. Based on the models of instrument and estimated visibilities, the astrometric accuracies for various kinds of stars are evaluated. It is important to emphasize that not only light sources, mirrors, lenses, field stop and detectors are all wavelength dependent, but also fringe visibility loss, wavefront error, optics control error, etc. are all a function of wavelengths. For the first time the estimate of SIM performance is based on spectral analysis of all factors above, rather than monochromatic approximations of detected fringes, or simply adopted constants. This paper summarizes the astrometric accuracies for a wide range of stars and various combinations of optical design and detector configurations. It has been verified that SIM has astrometric accuracy of about 4 μas for targets with different spectra.

Shao, Michael↗

Internal photoemission in Ag-Al2O3-Al junctions

The magnitude of the photon-induced current in Ag-Al2O3-Al metal-oxide-metal junctions has been studied as a function of photon energy and angle of incident radiation. Photocurrents were theoretically analyzed on the basis of a modified vacuum photoemission model (Jain, 1975; Slayman et al., to be published). Optical constants previously reported in the literature (Irani et al., 1971; Ehnrereich et al., 1963) were used to calculate the true spatial generation rate in Ag and Al as a function of the angle, polarization of incident radiation, and film thickness. Results were found to be in very good agreement with experimentally determined values for a tunable dye laser with a KDP doubling crystal pumped by a Q-switched Nd:YAG laser with a LiIO3 doubling crystal. The system provided risetimes of 50 ns or less and peak powers of 10 W. Under short circuit conditions, the photoresponse to incident power was linear up to available power densities of 10 kW/sq cm. Quantum efficiencies of about 0.1% at zero-bias, near 3.8 eV under P polarization, were typically observed.

Guedes, J. M. P.↗

Use of the transect method in satellite survey missions with application to the infrared astronomical satellite /IRAS/

The coverage of the celestial sphere or the surface of the earth with a narrow-field instrument onboard a satellite can be described by a set of swaths on the sphere. A transect is a curve on this sphere constructed to sample the coverage. At each point on the transect the number of times that the field-of-view of the instrument has passed over the point is recorded. This information is conveniently displayed as an integer-valued histogram over the length of the transect. The effectiveness of the transect method for a particular observing plan and the best placement of the transects depends upon the structure of the set of observations. Survey missions are usually characterized by a somewhat parallel alignment of the instrument swaths. Using autocorrelation and cross-correlation functions among the histograms the structure of a survey has been analyzed into two components, and each is illustrated by a simple mathematical model. The complex, all-sky survey to be performed by the Infrared Astronomical Satellite (IRAS) is synthesized in some detail utilizing the objectives and constraints of that mission. It is seen that this survey possesses the components predicted by the simple models and this information is useful in characterizing the properties of the IRAS survey and the placement of the transects as a function of celestial latitude and certain structural properties of the coverage.

Mclaughlin, W. I.↗

Arctic Tundra Vegetation Functional Types Based on Photosynthetic Physiology and Optical Properties

Non-vascular plants (lichens and mosses) are significant components of tundra landscapes and may respond to climate change differently from vascular plants affecting ecosystem carbon balance. Remote sensing provides critical tools for monitoring plant cover types, as optical signals provide a way to scale from plot measurements to regional estimates of biophysical properties, for which spatial-temporal patterns may be analyzed. Gas exchange measurements were collected for pure patches of key vegetation functional types (lichens, mosses, and vascular plants) in sedge tundra at Barrow AK. These functional types were found to have three significantly different values of light use efficiency (LUE) with values of 0.013+/-0.001, 0.0018+/-0.0002, and 0.0012+/-0.0001 mol C/mol absorbed quanta for vascular plants, mosses and lichens, respectively. Discriminant analysis of the spectra reflectance of these patches identified five spectral bands that separated each of these vegetation functional types as well as nongreen material (bare soil, standing water, and dead leaves). These results were tested along a 100 m transect where midsummer spectral reflectance and vegetation coverage were measured at one meter intervals.

Huemmrich, Karl F.↗

Arctic Tundra Vegetation Functional Types Based on Photosynthetic Physiology and Optical Properties

Non-vascular plants (lichens and mosses) are significant components of tundra landscapes and may respond to climate change differently from vascular plants affecting ecosystem carbon balance. Remote sensing provides critical tools for monitoring plant cover types, as optical signals provide a way to scale from plot measurements to regional estimates of biophysical properties, for which spatial-temporal patterns may be analyzed. Gas exchange measurements were collected for pure patches of key vegetation functional types (lichens, mosses, and vascular plants) in sedge tundra at Barrow, AK. These functional types were found to have three significantly different values of light use efficiency (LUE) with values of 0.013 plus or minus 0.0002, 0.0018 plus or minus 0.0002, and 0.0012 plus or minus 0.0001 mol C mol (exp -1) absorbed quanta for vascular plants, mosses and lichens, respectively. Discriminant analysis of the spectra reflectance of these patches identified five spectral bands that separated each of these vegetation functional types as well as nongreen material (bare soil, standing water, and dead leaves). These results were tested along a 100 m transect where midsummer spectral reflectance and vegetation coverage were measured at one meter intervals. Along the transect, area-averaged canopy LUE estimated from coverage fractions of the three functional types varied widely, even over short distances. The patch-level statistical discriminant functions applied to in situ hyperspectral reflectance data collected along the transect successfully unmixed cover fractions of the vegetation functional types. The unmixing functions, developed from the transect data, were applied to 30 m spatial resolution Earth Observing-1 Hyperion imaging spectrometer data to examine variability in distribution of the vegetation functional types for an area near Barrow, AK. Spatial variability of LUE was derived from the observed functional type distributions. Across this landscape, a fivefold variation in tundra LUE was observed. LUE calculated from the functional type cover fractions was also correlated to a spectral vegetation index developed to detect vegetation chlorophyll content. The concurrence of these alternate methods suggest that hyperspectral remote sensing can distinguish functionally distinct vegetation types and can be used to develop regional estimates of photosynthetic LUE in tundra landscapes.

VEGETATION↗

Research study on stabilization and control: Modern sampled-data control theory. Continuous and discrete describing function analysis of the LST system

The dynamics of the Large Space Telescope (LST) control system were studied in order to arrive at a simplified model for computer simulation without loss of accuracy. The frictional nonlinearity of the Control Moment Gyroscope (CMG) Control Loop was analyzed in a model to obtain data for the following: (1) a continuous describing function for the gimbal friction nonlinearity; (2) a describing function of the CMG nonlinearity using an analytical torque equation; and (3) the discrete describing function and function plots for CMG functional linearity. Preliminary computer simulations are shown for the simplified LST system, first without, and then with analytical torque expressions. Transfer functions of the sampled-data LST system are also described. A final computer simulation is presented which uses elements of the simplified sampled-data LST system with analytical CMG frictional torque expressions.

Kuo, B. C.↗

Continuous Risk Management at NASA

NPG 7120.5A, "NASA Program and Project Management Processes and Requirements" enacted in April, 1998, requires that "The program or project manager shall apply risk management principles..." The Software Assurance Technology Center (SATC) at NASA GSFC has been tasked with the responsibility for developing and teaching a systems level course for risk management that provides information on how to comply with this edict. The course was developed in conjunction with the Software Engineering Institute at Carnegie Mellon University, then tailored to the NASA systems community. This presentation will briefly discuss the six functions for risk management: (1) Identify the risks in a specific format; (2) Analyze the risk probability, impact/severity, and timeframe; (3) Plan the approach; (4) Track the risk through data compilation and analysis; (5) Control and monitor the risk; (6) Communicate and document the process and decisions. This risk management structure of functions has been taught to projects at all NASA Centers and is being successfully implemented on many projects. This presentation will give project managers the information they need to understand if risk management is to be effectively implemented on their projects at a cost they can afford.

Hammer, Theodore F.↗

The deep luminosity function of the globular cluster M30

An effort is made to determine the mass function in low-metallicity, postcore-collapse globular cluster M30, as well as to analyze its radial trend, using new deep CCD photometry. It is confirmed that oxygen-enhanced isochrones yield a good representation of the color-magnitude diagrams. Luminosity functions are constructed and corrected for for field-object contamination and incompleteness. The data presented agree with the power-law trend ascertained by Pryor et al. (1986) for a multimass King-Michie model, yielding a global slope of 0.7.

Piotto, Giampaolo↗